Interface manual
Thermal Transfer Printer
Solo type
Table of contents
3. Format of data.....................................................................................................................................5
4. Mask statement...................................................................................................................................6
4.1. Mask statement text ...................................................................................................................6
4.2. Mask statement Vectorfonts / proportional text..........................................................................7
4.3. Mask statement Vectorfonts / autoscale ....................................................................................8
4.4. Mask statement code .................................................................................................................9
4.5. Mask statement line graphics...................................................................................................10
4.6. Mask statement for internal stored graphics ............................................................................11
4.7. Mask statement for exact positioning (pixel) ............................................................................12
6. Code statement.................................................................................................................................15
I
Table of contents
II
Interface manual
The XON / XOFF-report is used in "memory"-mode. The XON-code (HEX 11) indicates that the printer
is ready to receive data. When XOFF-code (HEX 13) is shown the transmission of data has to be
interrupted. To avoid possible data loss some information will be stored into the data-memory.
When receiving, that the memory is empty the XON-code (HEX 11) will be shown again.
4 DTR HW-handshake
5 GND GND-signal
1
Interface manual
PIN 5 CTS
PIN 6 DSR
PIN 7 RTS
PIN 8 CTS
PIN 6 DSR
Hardware handshake:
1. printer (DSUB 9-plug) PC (DSUB 25-socket)
PIN 6 DSR
PIN 7 RTS
PIN 6 DSR
2
Interface manual
PIN 10 ACKNLG
PIN 11 In regular condition this signal is "LOW".
With decreasing amplitude of STROBE- signals,
BUSY will change onto "HIGH" - level.
This level will stay as long as the printer is busy
with the already received data byte.
3
Interface manual
2 DATA 0 (input) The signals are data bits sent to the printer. A HIGH
3 DATA 1 (input) level corresponds to logical 1 and a LOW level to
4 DATA 2 (input) logical 0.
5 DATA 3 (input)
6 DATA 4 (input)
7 DATA 5 (input)
8 DATA 6 (input)
9 DATA 7 (input)
10 ACKNLG (output) An impulse of approx. 12 µs confirms data input for
a LOW level and signalises the further listening
watch of the printer.
11 BUSY (output) A HIGH level indicates that the printer cannot
receive any data.
On the following conditions the signal HIGH is
possible:
1) for data input (impulse for each sign)
2) during a printing process
3) in Offline status
4) for printer failures
12 PE (output) A HIGH level indicates that paper is used up.
4
Interface manual
3. Format of data
The format of data consists of 4 parts, the mask part, the text, the code (if necessary) and the
command part.
Examples:
label with 3 lines text: 3 mask statements
3 text statements
1 command statement
label with 3 lines text and 1 code: 4 mask statements
4 text statements
1 code statement
1 command statement
All other data statements ASCII format, but they will be transmitted as hexadecimal characters.
5
Interface manual
4. Mask statement
SOH A n n y y y - x x x - r t t f f ey ey ex ex s s ETB
min. max.
A identification for mask statement
n number of field '01' '99'
y y-coordinate in mm
- dummy-byte
x x-coordinate in mm
- dummy-byte
r rotation of mask:
0= 0 degrees
1= 90 degrees
2= 180 degrees
3= 270 degrees
t type:
01 = regular font
02 = regular font inverse
f regular fonts
01 = FONT 01 (matrix 7 x 9 - w/o GEM)
02 = FONT 02 (matrix 10 x 14 - with GEM)
03 = FONT 03 (matrix 15 x 21 - with GEM)
04 = FONT 04 (matrix 32 x 45 - w/o GEM)
05 = FONT 05 (matrix 15 x 26 descender - with GEM)
06 = FONT 06 (matrix 14 x 23 OCR-A - w/o GEM)
07 = FONT 07 (matrix 10 x 18 descender - with GEM)
"Turbo fonts"
51 = FONT 1 (matrix 7 x 9)
52 = FONT 2 (matrix 10 x 14)
53 = FONT 3 (matrix 15 x 21)
54 = FONT 4 (matrix 32 x 45)
55 = FONT 5 (matrix 15 x 26 descender)
56 = FONT 6 (matrix 14 x 23 OCR-A)
57 = FONT 7 (matrix 10 x 28 descender)
ey extension of font in y-direction '01' '99'
ex extension of font in x-direction '01' '99'
s number of spaces between 2 characters '01' '99'
1 pixel = 0,125 mm
6
Interface manual
SOH A n n y y y - x x x - r t t f f ey ey ex ex s s ETB
min. max.
A identification for mask statement
n number of field '01' '99'
y y-coordinate in mm '001' '250'
- dummy-byte
x x-coordinate in mm '001' '105'
- dummy-byte
r rotation of mask:
0= 0 degrees
1= 90 degrees
2= 180 degrees
3= 270 degrees
t type:
04 = Vectorfonts proportional
06 = Vectorfonts proportional inverse
f font
01 = Helvetica Bold 02 = Helvetica Bold italics
03 = Helvetica Roman 04 = Helvetica Roman italics
05 = Swiss Light 06 = Swiss light italics
07 = Baskerville 08 = Baskerville italics
09 = Brush Script 10 = Brush Script italics
ey height of font in y-direction in mm (e.g. 20) '01' '99'
ex width of font in x-direction in mm (e.g. 20) '01' '99'
(It is recommended to use the same height and width)
s number of spaces between 2 characters '01' '99'
1 pixel = 0,125 mm
7
Interface manual
SOH A n n y y y - x x x - r t t f f ey ey ex ex - - ETB
min. max.
A identification for mask statement
n number of field '01' '99'
y y-coordinate in mm '001' '250'
- dummy-byte
x x-coordinate in mm '001' '105'
- dummy-byte
r rotation of mask:
0= 0 degrees
1= 90 degrees
2= 180 degrees
3= 270 degrees
t type:
05 = Vectorfonts autoscale
07 = Vectorfonts autoscale inverse
f font
01 = Helvetica Bold 02 = Helvetica Bold italics
03 = Helvetica Roman 04 = Helvetica Roman italics
05 = Swiss Light 06 = Swiss light italics
07 = Baskerville 08 = Baskerville italics
09 = Brush Script 10 = Brush Script italics
ey height of font in y-direction '01' '99'
ex field width in mm '01' '99'
- dummy-byte
8
Interface manual
SOH A n n y y y - x x x - r t t h h - - - - - - ETB
min. max.
A identification for mask statement
n number of field '01' '99'
y y-coordinate in mm '001' '250'
- dummy-byte
x x-coordinate in mm '001' '105'
- dummy-byte
r rotation of mask:
0= 0 degrees
1= 90 degrees
2= 180 degrees
3= 270 degrees
t type:
30 = Code 39
31 = 2/5 Interleaved
32 = EAN 8
33 = EAN 13
34 = UPC A
35 = UPC E
36 = CODABAR
37 = Code 128
38 = EAN ADD ON (2- and 5-digit)
39 = EAN 128
40 = Code 93
41 = PZN-Code
42 = Industry-Code 2/5
46 = Code 39 extended
h height of code in mm
- dummy-byte
9
Interface manual
SOH A n n y y y - x x x - r t t f f ey ey ex ex s s ETB
min. max.
A identification for mask statement
n number of field '01' '99'
y y-coordinate in mm '001' '250'
- dummy-byte
x x-coordinate in mm '001' '105'
- dummy-byte
r rotation of mask:
0 = horizontal line (if "type" = 11)
1 = vertical line (if "type" = 11)
when "type" = 10 (rectangle) not relevant
t type:
10 = rectangle
11 = line (difference see rotation)
f multiplication factor for extension '11' '99'
1. position multiply with ey
2. position multiply with ex
ey extension in y-direction '01' '99'
(with lines directly in mm)
ex extension in x-direction '01' '99'
(with lines directly in mm)
s line width in steps (1 step = 0,125 mm) '01' '99'
10
Interface manual
Graphics, which has been stored in a Memory-Card, will be tied up in a label. Per stored graphics one
mask statement res. one line is necessary. The storing of graphics either results via function key
MEMO (see operating manual) or via parameter res. remote statements (see chapter "10.3.6. To load
graphics onto MC").
SOH A n n y y y - x x x - r t t k k ey ey ex ex s s ETB
min. max.
A identification for mask statement
n number of field '01' '99'
y y-coordinate in mm '001' '250'
- dummy-byte
x x-coordinate in mm '001' '105'
- dummy-byte
r rotation
0= 0 degrees
1= 90 degrees
2= 180 degrees
3= 270 degrees
t type:
03 = internal graphics in Memory-Card
k identification for graphics (type of graphics name) '01' '99'
numerical graphics name: entry of "number" 1-99
alphanumerical graphics name: entry not significant;
transmission of the corresponding text statement
ey extension in y-direction '01' '99'
ex extension in x-direction '01' '99'
s numerical graphics name '02' '99'
alphanumerical graphics name: entry of '01'
11
Interface manual
text:
1 2 3 3 4 4 4 4 5 6 6 6 6 7 8 9 9 10 10 11 11 11 12 12 12 13 13
SOH A B n n y y y y - x x x x - r t t f f ey ey ey ex ex ex s s ETB
code:
1 2 3 3 4 4 4 4 5 6 6 6 6 7 8 9 9 10 10 11 11 11 12 12 12 13 13
SOH A B n n y y y y - x x x x - r t t h h - - - - - - - - ETB
line graphics:
1 2 3 3 4 4 4 4 5 6 6 6 6 7 8 9 9 10 10 11 11 11 12 12 12 13 13
SOH A B n n y y y y - x x x x - r t t f f ey ey ey ex ex ex s s ETB
stored graphics:
1 2 3 3 4 4 4 4 5 6 6 6 6 7 8 9 9 10 10 11 11 11 12 12 12 13 13
SOH A B n n y y y y - x x x x - r t t k k ey ey ey ex ex ex g g ETB
5. - = dummy-byte (1-digit)
7. - = dummy-byte (1-digit)
1 - 9 is the same in all mask statements (text, code, stored graphics, line graphics),
the rest 10 - 13 can be different from statement to statement (see following page).
12
Interface manual
12. ex : extension x-direction - with Vectorfonts in pixel (3-digit; value x 0,125 mm)
- with Matrix fonts as factor (3-digit)
code:
line graphics:
10. f : multiplication factor for extension (2-digit; 1. position for ey; 2. position for ex)
stored graphics:
13
Interface manual
5. Text statement
max. 99 statements
min. max.
B identification for text
statement
n number of field '01' '99'
s text bytes variable
at least 1 text byte
max. 70 text bytes
14
Interface manual
6. Code statement
SOH C n n s v1 v1 v2 v2 c ETB
min. max.
C identification for code statement
n number of code statement '01' '99'
s 0 = code without text
1 = code with text
v1 module width "THICK" '01' '64'
shows the width of the thick bars
e.g. 20 x 0,125 mm = 2,50 mm
v2 module width "THIN" '01' '21'
shows the width of the thin bars
e.g. 10 x 0,125 mm = 1,25 mm
c 0 = without check digit
1 = with check digit 2 = check digit control
4 = code inverse w/o check digit
5 = code inverse with check digit
In case a wrong SC-factor is entered, the printer automatically prints in the next possible SC-factor,
e.g. entry SC 3, print in SC 4
With EAN-Codes:
Basically it is possible, to vary the EAN symbol to be printed continuously between 80 % and 200 % of
the nominal value (1 module = 0,33 mm).
15
Interface manual
Type of code C=
1 with check digit (HIBC-code modulo 43; check digit will not be shown
in the display, but coded and printed underneath the code)
Code 39 / 2 check digit control
Code 39 ext.
3 CIP-code (only 6-digit; 7th digit is automatically the check digit)
(Code 39 only)
0 without check digit;
odd number of digits: 0 will be set automatically to the first position
1 with check digit:
odd number of digits: check digit will be added behind the last position
Code 2/5 even number of digits: the last digit will be overwritten by the check digit
check digit control
2 check digit control
3 special software (certain form and size of the text underneath the code)
1 corresponds to the entry of code 2/5 with calculation of check digit.
Minimal ratio: 21:7; entry of 13 res. 14 digits
Code ITF 14 (13 digits: a 14th digit will be added as check digit;
14 digits: the last digit will be overwritten by the check digit)
1 corresponds to the entry of code 2/5 with calculation of check digit.
Minimal ratio: 21:7; entry of 15 res. 16 digits
Code ITF 16 (15 digits: a 16th digit will be added as check digit;
16 digits: the last digit will be overwritten by the check digit)
Code 128 / 1 with check digit (modulo 103; check digit will not be shown in the
EAN 128 display and underneath the code, but only coded)
0 bbn-memory with check digit (cursor stands at the 8th digit)
1 with check digit (modulo 10, check digit will be shown in the display,
coded and printed underneath the code)
EAN 13
2 check digit control
3 additional PLU check digit at 7th digit
EAN 8 UPC A / E / X In this case the entry is irrelevant since the calculation of check digit is
EAN ADD ON always done; except P=2 check digit control
0, 1 with check digit (modulo 47; check digit will not be shown in the display
Code 93 and underneath the code, but only coded)
2 check digit control
0, 1 with check digit (modulo 11); 7th digit will be overwritten as check digit
PZN-Code
2 check digit control
0 no check digit
1 with check digit (modulo 10); the check digit will be added at the last
Industrial Code 2/5
position; however it won't be shown in the display, but only coded
2 check digit control
16
Interface manual
7. Command statement
7.1. To print
SOH E f f f s s s s ETB
min. max.
E = identification for command statement
f = function
A = print number of pieces
B = print number of pieces with cut after every label
K = print number of pieces w/o deleting of print buffer
f = number of lines to be printed '01' '99'
s = number of pieces '0001' '9999'
7.2. Offset
SOH E f - v - n n n ETB
min. max.
E = identification for command statement
f = function
F= OFFSET 1 (dispenser / cutter)
G= OFFSET 2 (Y-displacement)
I = OFFSET 3 ( X-displacement)
N= OFFSET 4 (tear off)
- = dummy-byte
v = prefix:
OFFSET 1 = '+'
OFFSET 2 = '+' and '-
OFFSET 3 = '+' and '-'
OFFSET 4 = '+'
- = dummy-byte
n = Offset in mm with F (dispenser / cutter) '00' '25'
with G (Y-displacement) gap label length
with I (X-displacement) '00' '99'
with N (tear off) '00' '25'
17
Interface manual
SOH E f 0 0 0 0 0 0 ETB
min. max.
E = identification for command statement
f = function
C= single cut
D= feed function
H= switch to continuous labels
J = switch from continuous labels to adhesive labels
(transfer label length or start "measure label"
manually at the printer)
SOH E E gl gl ll ll ll ll ETB
min. max.
E = identification for command statement
E = E = label length
gl = gap length '00' '99'
0 = gap length will not be transmitted separately
1-99 = gap length in mm
ll = label length '0007' '0250'
gap length = 0 i.e. label length with gap
gap length > 0 i.e. label length without gap
(measurements in mm)
18
Interface manual
SOH E L f f 0 0 l l ETB
min. max.
E = identification for command statement
L = L = to delete print buffer
f = number of lines to be deleted (with entry 0 the complete '00' '99'
label will be deleted)
l = line, from which it should be deleted (with entry 0 the '00' '99'
complete label will be deleted)
Interval cuts can only be performed in the mode with forth and back feed.
With interval cut it is possible to cut during the print order after a certain number of labels.
So the transferring of the normal command statement is not necessary.
SOH E M f f s s s s i i i e ETB
min. max.
E = identification for command statement
M = M = Interval cut (after the indicated interval of the number of
labels to be printed, the labels will be cut;
e.g. interval 3 = cut results after the print of 3 labels
f = number of lines to be printed '01' '99'
s = complete number of prints '0001' '9999'
i = number of labels, after which a cut results '000' '999'
e = 0= no cut after the end of the print order
1= cut after the end of the print order
2-9= cutter switched off
19
Interface manual
8. Graphics statement
min. max.
D = identification for graphics statement
p = pixel line from above '0000' '1900'
lb = 1. byte from left '000' '100'
s = number of bytes '1' '100'
gb = graphics bytes
graphics byte:
20
Interface manual
Via the serial interface the printer can be stopped and restarted again.
SOH s ETB
s = sequence:
'J' = stop sequence
'K' = start sequence
'L' = cancel sequence
9.2. Status
Via serial interface HOST-computers can receive status information of the printer.
The status request has the following data format:
SOH S ETB
S = ASCII 'S'
Status answer:
After receiving the status request the printer transfers the corresponding status answer.
21
Interface manual
8. bit = free
7. bit = always set
6. bit = free
5. bit = 1 - print order runs
0 - no. of pieces = 0 (no print order)
4. bit = 1 - stop key activated
0 - stop key not activated
3. bit = cutter error
0 - no error
1 - error
2. bit = labels
0 - no error
1 - error
1. bit = ribbon
0 - no error
1 - error
2. byte = 2. status byte
8. bit = free
7. bit = free
6. bit = free
5. bit = free
4. bit = free
3. bit = Memory-Card
2. bit = mask statement
1. bit = printhead temperature
5.-1. position = no. of pieces 5-digit as ASCII-character
min. '00000' / max. '65535'
22
Interface manual
The auto status will be served, i.e. in certain operating modes the printer actively sends the
corresponding status.
To activate the auto status, the PC has to send the following command to the printer:
Each of the messages shown below, which are observed and sent by the printer, has to be transmitted
to the printer by the auto status with one bit set (see below "1. byte" and "2. byte"). The printer sends
after each performed condition the corresponding message (answer) to the PC.
1- Start of generation
2- End of generation
In regular mode the printer sends this status in case the data of a complete label has been
generated. The test print is not being considered.
In case of consecutive numbering / RTC the printer send for each label a status cycle (start,
end).
3- Start of printing
4- End of printing
This status exists only in dispensing mode. The start of the print will be send when the
GENERATED data will be printed. The end of the print will be send when the print of the label
is finished, the motor is stopped.
5- Start of cutting
6- End odd cutting
This status describes the cutting. Here it is possible to check the end of the cutting at
TIMEOUT --> error
23
Interface manual
1. byte:
1= always 0
2= start feeding (7) since V 1.04
3= end cutting (6) since V 1.04
4= start cutting (5) since V 1.04
5= end printing (4) since V 1.04
6= start printing (3)
7= end generation (2)
8= start generation (1)
2. byte:
1= always 0
2= -
3= -
4= -
5= error (11)
6= end print order (10)
7= start print order (9)
8= end feeding (8) since V 1.04
Attention: In byte 1 and byte 2, the 1 bit always has o be '0', otherwise the printer possibly could
recognise SOH or ETB.
The auto status will not be stored in the printer, i.e. the printer is set to '0' after turning OFF/ON. The
printer always has to be initialised after turning on the printer.
Example:
After performed condition (= start of print order) the printer sends the following answer to the PC:
The answer corresponds always to the format statement in regard to the contents.
24
Interface manual
With the remote and parameter statement the printer will be controlled remote. The structure of these
statement is very similar, yet they will be treated separately.
Remote statement:
The remote statement is the actual remote statement. This statement will be treated immediately in
contrast to the parameter statement, i.e. during a running print order too. Thereby the printer reacts
immediately to commands which are sent via the remote statement. The structure of the remote
statement is shown on the following pages.
Parameter statement:
The parameter-statement is used for adjusting the various parameters of the corresponding label. This
statement will be loaded into the receiving buffer like the mask, command and code statement. A new
parameter statement will only be treated after the end of a print order. Thereby it is possible to keep
several labels within the receiving buffer, whereby one parameter-statement is necessary for each
label. So each label can be printed with a different print speed, print intensity, etc. The PC does not
have to send any data until the receiving buffer is empty.
Attention: The remote statement can be sent only via serial interface. The parameter statement
can be sent via serial interface as well as via parallel interface.
SOH 1 2 3 4 5 6 7 8 8 8 8 8 8 8 8 ETB
Parameter
25
Interface manual
The remote and parameter statements are, like all other statements, enclosed by SOH and ETB.
After SOH first 7 identification bytes and then 8 parameter bytes are following.
Column 1: This byte is the identification, whether a remote statement (R; 52Hex) or a parameter
statement (F; 46Hex) is following.
Column 2: Identification of "field-area"; the structure corresponds to the control entry. This
identification of "field-area" can be executed via the foil keyboard (memo, quant,..)
Column 3: identification 2
Column 4: identification 3
Column 7: Flag, whether the transferred parameter should be read or if the printer has to send the
required parameter to the PC.
'r' (72Hex) ''r' (72 Hex) - printer should take over the parameter res. execute the
command already sent.
'w' (77Hex) 'w' (77 Hex) - printer should send back the required parameter to the PC.
Column 8: Parameter. Here 8 bytes are reserved. This parameter area serves for handing over data
to the printer, res. for sending an answer identification, which send the printer back to the
PC via answer statement. These 8 bytes always have to be transferred to the printer.
The content will only be evaluated if an 'r' is transferred in column 7.
Column 9: Here the number of bytes / characters is shown, which the printer considers res. treats in
the answer statement. The bytes will be counted from the left to the right. Column 9
serves only for explanations and is not necessary for the data transmission.
26
Interface manual
1 2 3 4 5 6 7 8 9
R/F A: MEMO A: Save X X X r parameter 8 ASCII
B: Load X X X r parameter 8 ASCII
C: Delete X X X r parameter 8 ASCII
D: Format X X X r parameter ----
E: Copy * X X X r parameter ----
F: Load graphics A: cancel * X X r parameter ----
B: activate * X X r parameter 8 ASCII
C: take over * X X r parameter ----
G: Print contents X X X r parameter ----
H: Available memory X X X w parameter 7 ASCII
B: Quant A: Number of lines * X X X r/w parameter 2 ASCII
B: Number of pieces A: Order * X X r/w parameter 5 ASCII
B: Nominal value X X w parameter 5 ASCII
C: Actual value X X w parameter 5 ASCII
D: Interval * X X r/w parameter 4 ASCII
C: Print * X X X r parameter ----
C: F A: Print parameter A: Speed X r/w parameter 3 ASCII
B: Contrast X X r/w parameter 3 ASCII
B: Measuring of label * X X X r/w parameter ----
C: Printer initialisation A: Measuring X X r/w parameter 1 ASCII
B: Keyboard click X X r/w parameter 1 ASCII
C: Offset 1 * X X r/w parameter 3 ASCII
D: Offset 2 * X X r/w parameter 3 ASCII
E: Offset 3 * X X r/w parameter 3 ASCII
F: Dispenser level LS * X X r/w parameter 2 ASCII
G: Offset 4 * X X r/w parameter 3 ASCII
H: Print of several columns * A: Columns X r/w parameter 1 ASCII
B: Width X r/w parameter 3 ASCII
I: Label length / gap width * X X r/w parameter 2 ASCII
J: Print initialisation X X r parameter 2 ASCII
D: Printing mode A: Continuous labels * X X r/w parameter 1 ASCII
B: Ribbon control X X r/w parameter 2 ASCII
C: Dispensing mode * X X r/w parameter 1 ASCII
D: Cutting mode X X r/w parameter 1 ASCII
E: Type of label photocell * X X r/w parameter 1 ASCII
F: Stacking mode X X r/w parameter 1 ASCII
G: Print stop after 1 label X X r/w parameter 1 ASCII
H: Label inverse X X r/w parameter 4 ASCII
E: Sensitivity label photocell X X X r/w parameter 3 ASCII
F: Serial interface A: Baud * X X r/w parameter 5 ASCII
* All statements marked with (*) as remote statements in reading cycle (dolumn 7 "r") no reaction results during a running
print order
27
Interface manual
1 2 3 4 5 6 7 8 9
D: Start-Stop X X X X r parameter 1 ASCII
cancel
E: Feeding * X X X X r parameter ----
F: Test print * X X X X r parameter ----
G: Delete print / X X X X r parameter 2 ASCII
receiving buffer
X: CFG_Save X X X X r parameter ----
* All statements marked with (*) as remote statements in reading cycle (column 7 "r") no reaction results during a
running print order
28
Interface manual
Following, the statements will be described, which can be sent via a parameter res. remote statement
('-' = entry 0).
The bytes are separated by commas. For explanation purposes are shown as an example. For a
parameter statement only the first column has to be changed (RF).
SOH,F,A,A,-,-,-,r,E,X,A,M,P,L,E,S,ETB
The label with the name EXAMPLES will be saved onto the Memory-Card. The number of lines set in
the printer at the moment will be saved; i.e. to save a label from a Host-computer onto the MC, you
have to follow the instructions:
SOH,F,A,B,-,-,-r,E,X,A,M,P,L,E,S,ETB
Here the label with the name EXAMPLES will be loaded from the Memory-Card into the printer. The
number of lines will be set automatically to the correct value. In case no label with the name
EXAMPLES is saved onto the MC, an error message results.
All names will be transferred 8-digit, i.e. if necessary with gaps.
SOH,F,A,C,-,-,-,r,E,X,A,M,P,L,E,S,ETB
The label with the name EXAMPLES will be deleted from the Memory-Card. In case no label with the
name EXAMPLES is saved onto the MC, an error message results.
29
Interface manual
10.3.4. To format a MC
SOH,F,A,D,-,-,-,r,-,-,-,-,-,-,-,-,ETB
A new Memory-Card has to be formatted before the first use. All data on the MC will be deleted. With
this command no parameters have to be transferred.
10.3.5. To copy a MC
SOH,F,A,E,-,-,-,r,-,-,-,-,-,-,-,-,ETB
With this command the copying of a MC can be started. It is absolutely necessary that a user has to
be at the printer. On the display of the printer the message: "Insert source MC + Enter" appears. The
user has to insert the source MC into the printer and has to activate key "E" or "start/stop". Now the
contents of the MC will be loaded into the printer and the message: "Insert target MC + Enter"
appears. The user has to insert the target MC into the printer and has to activate key "E" again. Now
the contents of the source MC will be loaded from the printer onto the target MC. The complete
contents of the target MC will be overwritten. Therefore the target MC does not have to be formatted.
This function enables to load graphics onto the Memory-Card. The graphic data will be transferred via
the standard graphic statements to the printer. Receiving the command statement "print number of
pieces", the graphic transfer is considered as finished; the received graphics will be saved under the
transferred name onto the Memory-Card.
take over function; save graphic from print buffer onto Memory-Card
SOH,F,A,F,C,-,-,r,-,-,-,-,-,-,-,-,ETB
transfer graphics statements (see chapter "8. Graphics statement").
SOH,F,A,G,-,-,-,r,-,-,-,-,-,-,-,-,ETB
This function enables the printout of the table of contents res. all label names of the Memory-Card in
the format of the mask set before (as text with a certain font or as code).
30
Interface manual
SOH,R,A,H,-,-,-,w,-,-,-,-,-,-,-,-,ETB
After this command the printer sends with the answer statement the available memory of the Memory-
Card to the printer. In the answer statement the first three bytes are valid. The value will be indicated
in kbyte (at least 0 kbyte until max. 127 kbyte).
answer: SOH,A,N,N,N,-,-,-,-,-,p,p,p,p,p,p,p,p,ETB
answer: SOH,A,N,N,-,-,-,-,-,-,p,p,p,p,p,p,p,p,ETB
With this command the host computer can request the following numbers of pieces:
answer: SOH,A,N,N,N,N,-,-,-,-,p,p,p,p,p,p,p,p,ETB
31
Interface manual
Also with this statement it is possible to transfer the number of pieces of the print order and the interval
at the printer in cutting mode.
SOH,F,B,C,-,-,-,r,-,-,-,-,-,-,-,-,ETB
This command starts the actual print order of the printer. The actual parameter like print mode, speed,
initialisation, etc. are used. Thereby this command enables e.g. to print 5-digit number of pieces, by
transferring the corresponding number of pieces with statement 10 before.
With this command the print parameter speed and print intensity can be changed res. read.
set speed
SOH,F,C,A,A,-,-,r,N,N,N,-,-,-,-,-,ETB
request speed answer:
SOH,R,C,A,A,-,-,w,p,p,p,p,p,p,p,p,ETB SOH,A,N,N,N,-,-,-,-,-,p,p,p,p,p,p,p,p,ETB
32
Interface manual
In case a new label roll is in the printer, the measuring of the label can be activated via this command.
SOH,F,C,B,-,-,-,r,-,-,-,-,-,-,-,-,ETB
The actual label length and gap length in the printer can be sent to a host computer, too.
SOH,R,C,B,-,-,-,w,p,p,p,p,p,p,p,p,ETB
After this command the printer sends the following answer statement:
answer: SOH,A,E,E,E,E,S,S,S,S,p,p,p,p,p,p,p,p,ETB
EEEE indicates the label length in mm (ASCII)
SSSS indicates the gap length in mm (ASCII)
Within the printer initialisation the following values can be changed res. read:
33
Interface manual
34
Interface manual
Under print mode the following parameters of the printer can be set res. requested:
35
Interface manual
set print stop after 1 label N = '0' - print stop after 1 label OFF
SOH,F,C,D,G,-,-,r,N,-,-,-,-,-,-,-,ETB N = '1' - print stop after 1 label ON
request print stop after 1 label answer:
SOH,R,C,D,F,-,-,w,p,p,p,p,p,p,p,p,ETB SOH,A,N,-,-,-,-,-,-,-,p,p,p,p,p,p,p,p,ETB
set label inverse N = '0' - label inverse OFF
SOH,F,C,D,H,-,-,r,N,-,M,M,M,-,-,-,ETB N = '1' - label inverse ON
MMM = MMM = set of width to be inverse, 3-digit
ASCII-figure in mm [0..80]
With this command the sensitivity of the label photocell can be set res. requested.
set sensitivity
SOH,F,C,E,-,-,-,r,N,N,N,-,-,-,-,-,ETB NNN indicates the sensitivity in % (010...118)
36
Interface manual
The parameter of the serial interface can be set via the following commands. Hereby you have to
notice, that after sending one of these commands, the host computer also changes the corresponding
parameter of its interface, to enable a further communication between host computer - printer.
There are two different interface protocols available. Usually SOH = 01HEX and
ETB = 17HEX. However there are host computers (IBM), which can't work with these characters.
Therefore you can switch to SOH = 5EHEX and ETB = 5FHEX. As described earlier under chapter
"10.3.17. Parameter serial interface", the host computer has to change the corresponding parameter
as well.
37
Interface manual
The odometer of the printer only can be read but it can't be set to 0.
The Real-Time-Clock, which can be ordered as option, can be set res. read with the following
commands.
set date DD: day of month MO: month YY: year ('92)
SOH,F,C,I,A,-,-,r,D,D,M,O,Y,Y,D,W,ETB DW: day of week ('00'---Sunday)
request date answer:
SOH,R,C,I,A,-,-,w,p,p,p,p,p,p,p,p,ETB SOH,A,D,D,M,O,Y,Y,D,W,p,p,p,p,p,p,p,p,ETB
set time HH: hours, MI: minutes, SS: seconds
SOH,F,C,I,B,-,-,r,H,H,M,I,S,S,A,M,ETB
AM: mode - 'am' = 12 hour mode AM
'pm' = 12 hour mode PM
'--' = 24 hour mode
request time answer:
SOH,R,C,I,B,-,-,w,p,p,p,p,p,p,p,p,ETB SOH,A,H,H,M,I,S,S,A,M,p,p,p,p,p,p,p,p,ETB
10.3.21. CV_NET
38
Interface manual
10.3.22. Password
With these commands several function groups can be blocked via password at the printer.
set password
SOH,F,C,K,A,-,-,r,N,N,N,N,-,-,-,-,ETB NNNN indicates the 4-digit password (0000...9999)
Attention:
As soon as printer emulation is switched "ON" the
SOH will change from value 0 x 01 to 0 x 16, i.e. the
following sets have to be sent with SOH = 0 x16.
39
Interface manual
Additionally to the start / stop command it is possible to interrupt a print order via parameter / remote
statement.
10.3.25. Feeding
SOH,F,E,-,-,-,-,r,-,-,-,-,-,-,-,-,ETB
SOH,F,F,-,-,-,-,r,-,-,-,-,-,-,-,-,ETB
With this command a test print results.
With this command the print buffer and the receiving buffer can be deleted. This is also possible during
a current print order, i.e. print orders that already exist in the printer as well as the current print order
can be deleted.
10.3.28. CFG_Save
SOH,F,X,-,-,-,-,r,-,-,-,-,-,-,-,-,ETB
CFG_Save saves the actual initialisation of the printer in the serial EEPROM, thereby even
parameters adjusted via interface keep remaining after switching off the printer.
40
Interface manual
The printer send back the answer statement to the PC, when a REMOTE / PARAMETER
STATEMENT with identification 'w' of column 7 has been received.
parameter 2 can be used to coordinate the answer statement in the PC to the previous request.
They correspond to the parameters sent with the remote / parameter statement; they
won't be processed but always sent back.
10.5. Interfaces
The remote statement only can be sent to the printer via serial interface. The parallel interface only
can receive data, i.e. it is not possible to transfer data from the printer to the PC. Because of that
reason the remote statement cannot be used via the parallel interface. The parameter statement also
can be sent via the parallel interface, but no data can be transferred back from the printer as described
earlier.
41
Interface manual
initial point of
printhead (x = 0)
position 2
= rotation by 180 degrees
= no rotation
= rotation by 90 degrees
position 1
position 0
42
Interface manual
If consecutive numbering of labels is desired, this can be entered in text and code lines.
A maximum of 99 lines per label is possible. Each line can be numbered. The entry of mask should be
defined that the lines with numbering are the last ones.
The consecutive numbering has to be defined by 9 control characters in the text line, whereby the
value can be changed between 1 and 99.
Up to version 2.04 it could be counted from 0 to 9 (decimal) res. from A to Z only. Since version 3.01
this counting mode can be effected with the radix values 00 res. 01.
text input:
1 2 3 4 .................. 62 63 64 65 66 67 68 69 70
1 0 0 0 .................. rv rv nv nv np np il +/- #
43
Interface manual
The radix value is transferred to the printer via the following statement:
SOH H A z z z N r r ETB
min. max.
H = identification for variable statement
A = identification for printer
z = number of lines '001' '099'
N = type of variable consecutive numbering
r = radix value for consecutive numbering function '00' '36'
44
Interface manual
Since version 1.04 the user has the possibility to define an own special user's guiding.
The special user's guiding enables the print of label with variables in stand alone mode (see also
corresponding operating manual).
Therefore one or several variables will be defined when creating the label. They will be shown in the
display and entered directly at the printer. The user does not have to search the line with the variable
in the entry menu, but he will be led directly from one variable the next. After entering all variables the
print can be started immediately.
The user's guiding has to be switched on in function menu in the menu item "Password".
The activation results via 13 control characters in the text line.
While creating a variable text or barcode line the following has to be defined:
a help text ("prompt") for the variable
the variable itself
13 control characters, by which the activation results
Since version 3.01 it is possible to define a user guided variable with consecutive numbering.
Position 65 is the identification for the user's guiding with consecutive numbering.
If the value '1' is entered, the positions 58 to 63 are the identification bits for consecutive
numbering.
The entry of mask of a variable line corresponds to the one of text or barcodes. The variable itself
will be defined in the entry of text line.
1 - 24 25 - 48 .... 58 59 60 61 62 63 64 65 66 67 68 69 70
help text start text nv nv np np il +/- N N jf ac sp sp !
position 1 - 24: help text for the variable, e.g. "enter price"
position 25 - 48: start text, e.g. 200,50 DM
position 58, 59: value of consecutive numbering (value of change per label)
position 60, 61: position of numbering (where consecutive numbering is active)
position 62: number of labels with identical number
position 63: '+' = adding numbering
'-' = subtracting numbering
position 64: is not being used for the moment, but you have to enter "0".
position 65: 0 = user guided variable 1 = user guided variable with consecutive numbering
position 66: function to jump over special characters: . , ; : - /
0 = deactivated 1 = activated
position 67: allowable characters:
0 numerical characters (0...9) + spaces
1 alphanumerical characters
position 68, 69: start position (<= 24)
position 70: activate variable
Attention: Don't forget to save the label including variables, which have been created at the printer
onto the Memory-Card, because after switching on the user's guiding just reading only
functions of the Memory-Card are allowed and the variables exist in such a manner in
the internal printer buffer, as long as the user's guiding is switched on. Otherwise the
variable will be changed into a normal text line, i.e. the start text and the 13 control
characters will be deleted.
45
Interface manual
A check digit is being calculated. The Code 39 only has a small density of information and a small
tolerance. The spaces within a character carry an information.
The start / stop character will be realised with the special character '*'.
The Code 39 can be printed in any ratio not smaller than 3:1.
CIP-Code
By entering '3' as check digit the CIP-Code can be selected. This code has 6 digits, the 7th
automatically represents the check digit.
46
Interface manual
The Code 2/5 interleaved is a numerical code without check digit. The code must have an even
number of digits. In case of an odd number of digits a leading '0' automatically will be put in front. The
Code 2/5 interleaved has a high density of information and a small tolerance. All spaces carry a
information.
47
Interface manual
The EAN 8 / 13 is a numerical code with 1 check digit. The code always has a fix number of 8 res. 13
digits. The EAN 8/13 has fixed, very small tolerances. Besides the 10 possible digits 1 additional
separation and 1 border character is available.
With this code the width and height are fixed. The following schedule shows the proportions of the
code between the corner points. The enlargement factor changes the height of the font.
EAN 13: size of code / font module width in mm Norm module width in mm
SC0 0,270 0,25
SC4 0,396 0,375
SC7 0,544 0,5
SC9 0,660 0,625
The Code UPC A / UPC E is a numerical code with 1 check digit. The code always has a fix number of
12 res. 8 digits. The code has a high density of information and fixed, very small tolerances.
For UPC A 10 digits, 1 separation and 1 border character are available, for UPC E 10 digits and 2
border characters can be used.
With this code the width and height are fixed. The following schedule shows the proportions of the
code between the corner points. The enlargement factor changes the height of the font.
With this code the width is fixed by the single characters. The same enlargement factors as for UPC A
are possible.
48
Interface manual
The only difference between Code EAN 128 and Code 128 is the second start character (FNC1);
that's why they won't be described separately.
The Code 128 consists of the ASCII font. The code has 1 check digit, 3 start characters and 1 stop
character, a high density of information and is suitable for all print techniques.
The ASCII font can' be displayed completely just with one font.
The supply of characters consists of: 128 ASCII- characters, 4 special characters, 4 control
characters, 3 start characters, 1 Stop character
The check digit of code 128 is being calculated with modulo 103. Reference numbers are assigned to
the characters of Code 128, as well as 3 start characters. The factor of importance begins with 1 at the
first useful character (left to right) and increases by 1 after each useful character.
For encoding and decoding the code schedule Code 128 has to be used.
49
Interface manual
Code A Code B Code C Decimal ASCII Code A Code B Code C Decimal ASCII
SP SP 00 32 SP V V 54 86 V
! ! 01 33 ! W W 55 87 W
" " 02 34 " X X 56 88 X
# # 03 35 # Y Y 57 89 Y
$ $ 04 36 $ Z Z 58 90 Z
% % 05 37 % [ [ 59 91 [
& & 06 38 & \ \ 60 92 \
( ( 08 40 ( ] ] 61 93 ]
) ) 09 41 ) ^ ^ 62 94 ^
* * 10 42 * ´ ´ 07 39 ´
+ + 11 43 + _ _ 63 95 _
, , 12 44 , NUL ` 64 96 `
- - 13 45 - SOH t 65 97 t
. . 14 46 . STX s 66 98 s
/ / 15 47 / ETX c 67 99 c
0 0 16 48 0 EOT r 68 100 r
1 1 17 49 1 ENQ e 69 101 e
2 2 18 50 2 ACK f 70 102 f
3 3 19 51 3 BEL g 71 103 g
4 4 20 52 4 BS h 72 104 h
5 5 21 53 5 HT i 73 105 i
6 6 22 54 6 LF j 74 106 j
7 7 23 55 7 VT k 75 107 k
8 8 24 56 8 FF l 76 108 l
9 9 25 57 9 CR m 77 109 m
: : 26 58 : SO n 78 110 n
; ; 27 59 ; SI o 79 111 o
< < 28 60 < DLE p 80 112 p
= = 29 61 = DC1 q 81 113 q
> > 30 62 > DC2 r 82 114 r
? ? 31 63 ? DC3 s 83 115 s
@ @ 32 64 @ DC4 t 84 116 t
A A 33 65 A NAK u 85 117 u
B B 34 66 B SYN v 86 118 v
C C 35 67 C ETB w 87 119 w
D D 36 68 D CAN x 88 120 x
E E 37 69 E EM y 89 121 y
F F 38 70 F SUB f 90 122 f
G G 39 71 G ESC { 91 123 {
H H 40 72 H FS | 92 124 |
I I 41 73 I GS } 93 125 }
J J 42 74 J RS ~ 94 126 ~
K K 43 75 K US DEL 95 127 DEL
L L 44 76 L FNC3 FNC3 96 128
M M 45 77 M FNC2 FNC2 97 129
N N 46 78 N SHIFT SHIFT 98 130
O O 47 79 O CODE C CODE C 99 131
P P 48 80 P CODE B FNC4 CODE B 132
Q Q 49 81 Q FNC4 CODE A CODE A 133
R R 50 82 R FNC1 FNC1 FNC1 134
S S 51 83 S Start 135
T T 52 84 T Start 136
U U 53 85 U Start 137
50
Interface manual
14.6. Code 93
The code 93 is an alphanumerical code with special and control characters. The following characters
are available:
capital letters from A-Z
digits from 0 - 9
special characters : '-', '.', 'SPACE', '$', '/', '+', '%'
4 control characters
1 start / stop character
Two check digits are being calculated. The Code 93 has the highest density of information of all
alphanumerical codes and a small tolerance. The spaces within a characters carry an information. The
complete ASCII font can be produced.
51
Interface manual
The Industrial Code 2/5 is a numerical code without check digit. The code has a small density of
information and a high tolerance. Only the bars are coded, the spaces don't contain information and its
width can vary. In addition to the 10 possible digits 1 start character and 1 stop character is available.
52
Interface manual
To activate thesefonts the PC and the printer have to be set to 8 bit / no parity.
ASCII-font english GEM-font
ASCII Dec. HEX ASCII Dec. HEX type Dec. HEX type Dec. HEX type Dec. HEX
SP 32 20 Q 81 51 Ç 128 80 õ 177 B1 226 E2
! 33 21 R 82 52 ü 129 81 ¥ 178 B2 227 E3
" 34 22 S 83 53 é 130 82 ¢ 179 B3 € 228 E4
# 35 23 T 84 54 â 131 83 œ 180 B4
$ 36 24 U 85 55 ä 132 84 Œ 181 B5
% 37 25 V 86 56 à 133 85 À 182 B6
& 38 26 W 87 57 å 134 86 Ã 183 B7
´ 39 27 X 88 58 ç 135 87 Õ 184 B8
( 40 28 Y 89 59 ê 136 88 § 185 B9
) 41 29 Z 90 5A ë 137 89 ? 186 BA
* 42 2A [ 91 5B è 138 8A † 187 BB
+ 43 2B \ 92 5C ï 139 8B ¶ 188 BC
, 44 2C ] 93 5D î 140 8C © 189 BD
- 45 2D ^ 94 5E ì 141 8D ® 190 BE
. 46 2E - 95 5F Ä 142 8E TM 191 BF
/ 47 2F 96 60 Å 143 8F 192 C0
0 48 30 a 97 61 É 144 90 … 193 C1
1 49 31 b 98 62 æ 145 91 ‰ 194 C2
2 50 32 c 99 63 Æ 146 92 . 195 C3
3 51 33 d 100 64 ô 147 93 – 196 C4
4 52 34 e 101 65 ö 148 94 — 197 C5
5 53 35 f 102 66 ò 149 95 ° 198 C6
6 54 36 g 103 67 û 150 96 Á 199 C7
7 55 37 h 104 68 ù 151 97 Â 200 C8
8 56 38 i 105 69 ÿ 152 98 È 201 C9
9 57 39 j 106 6A Ö 153 99 Ê 202 CA
: 58 3A k 107 6B Ü 154 9A Ë 203 CB
; 59 3B l 108 6C ø 155 9B ì 204 CC
< 60 3C m 109 6D £ 156 9C Í 205 CD
= 61 3D n 110 6E Ø 157 9D Î 206 CE
> 62 3E o 111 6F ~ 158 9E Ï 207 CF
? 63 3F p 112 70 _ 159 9F Ò 208 D0
@ 64 40 q 113 71 á 160 A0 Ó 209 D1
A 65 41 r 114 72 í 161 A1 Ô 210 D2
B 66 42 s 115 73 ó 162 A2 211 D3
C 67 43 t 116 74 ú 163 A3 212 D4
D 68 44 u 117 75 ñ 164 A4 Ù 213 D5
E 69 45 v 118 76 Ñ 165 A5 Ú 214 D6
F 70 46 w 119 77 ¼ 166 A6 Û 215 D7
G 71 47 x 120 78 ½ 167 A7 Ÿ 216 D8
H 72 48 y 121 79 ¾ 168 A8 217 D9
I 73 49 z 122 7A " 169 A9 218 DA
J 74 4A { 123 7B " 170 AA 219 DB
K 75 4B | 124 7C ‹ 171 AB 220 DC
L 76 4C } 125 7D › 172 AC 221 DD
M 77 4D ~ 126 7E 173 AD 222 DE
N 78 4E £ 127 7F « 174 AE µ 223 DF
O 79 4F » 175 AF 224 E0
P 80 50 ã 176 B0 ß 225 E1
53
Interface manual
Thermal-Transfer-Printer solo 80
Print
Label width 85 mm
Print width 80 mm
max. label height 190 mm
Print area w x h 80 x 144 mm
Option
max. label height 390 mm
Print area w x h 80 x 348 mm
Label material max. 220 g/m² (stronger material on demand)
Resolution 8 dots/mm
Print speed 60 – 100 mm/s
Text various fonts
Character height min. 1,1 mm
Text lines per label max. 99
Characters per line 70
7 x 9 / 10 x 14 / 15 x 21 / 32 x 45 /
Matrix fonts (matrix h x w) 10 x 18 descender / 15 x 26 descender
14 x 23 OCR-A / normal, inverse
Helvetica Bold, Helvetica Roman, Swiss Light,
Baskerville, Brush Script
Vector fonts: italics + inverse, autoscale + proportional
GEM-font with foreign type font
incl. special characters
Special fonts on demand
Print memory approx. 80 KB
Label memory Memory-Card 128KB (Option)
2/5 Interleaved, Ind.-Code 2/5, ITF 14/16,
EAN 8, EAN 13, EAN 128, EAN ADD-ON, UPCA,
Barcode UPCE, Code 39, Code 93, Code 128,
Code 39 extended, PZN-Code
in all four directions
Print ratio: variable
Label formation variable
Interface RS232 / Centronics XON-XOFF
or DTR-protocol / RS 485 (Option)
Baudrate (Baud) 2400 - 9600
Label roll dimensions
Diameter outside / inside 160 / 40 mm
max. width 85 mm
Dimensions
height x width x depth 205 x 230 x 330 mm
Weight ~ 7,5 kg
Ambient temperature 5 - 45°C
Relative humidity range max. 80 %
54
Interface manual
OK
LIST
90 REM THIS IS THE MASK STATEMENT
100 LPRINT CHR$ (1);
110 LPRINT "A";
130 LPRINT "01";
140 LPRINT "0350090000103040405";
150 LPRINT CHR$ (23);
155 REM THIS IS THE TEXT STATEMENT
160 LPRINT CHR$ (1);
170 LPRINT "B";
180 LPRINT "01";
190 LPRINT "SOLO 80";
200 LPRINT CHR$ (23);
205 REM THIS IS THE COMMAND STATEMENT;
210 LPRINT CHR$ (1);
220 LPRINT "E";
230 LPRINT "A";
40 LPRINT "010002";
250 LPRINT CHR$ (23);
260 END
OK
Explanation
A01036-046-03315------ Mask statement for barcode
C01100041 Code statement
B01444444444444 The corresponding text statement
A02006-047-00401030203
A03006-031-00401040303
A04011-047-00401040303
A05018-047-00401030203
A06019-037-00401060403
} The five mask statements Vectorfont /
proportional text
B02Art.Nr.
B0344444
B04Artikelbezeichnung
B05DM
B0699,--
} The five corresponding text statements
55
Interface manual
Contrast
Measure label
Print initialisation
Measure label (when turning on the printer) ON/OFF
OFF
Printing mode Continuous labels ON/OFF
I/O static
Ribbon control ON/OFF I/O dynamic
weak / strong sensibility
Photocell
Dispensing mode I/O continuous static
I/O continuous dynamic
Photocell continuous
56
Interface manual
Serielle
Interface
Schnittstelle
protocol 2 COM of header SOH
Start
Baudof header ETB
End
Paper counter
(printer)
Inerface test
RTC
Set time / date
(actual time / date)
Password Password
Password protection
F (Function menu)
MC (Memory-Card)
E (Entry)
D (Print function)
B (User's guiding)
57
Interface manual
In the following all menus of the function menu are catalogued with its menu items. The tabulated view
shows exactly which keys have to be pressed in order to reach a certain menu item to alter values /
parameters.
Alterations in the function menu can be done either by the numeric foil keyboard at the printer or by
the corresponding keys of an external keyboard. The adjusted parameters will be stored in an
EEPROM and after switching on the printer again these parameters will be available.
View of function menu:
back to
start function menu
to switch to
next menu
to change
values
to store
values
basic menu
(w/o storing)
1. Print parameters
to 2.
Measure label
Speed (60-100 mm/s)
Contrast
Transfer print: 10-350 %
Thermal print: 210 %
back to: "Speed"
2. Measure label
to 3.
release
Printer
initialisation
Values are shown and stored;
label will be measured
3. Printer initialisation
to 4.
Printing mode
58
Interface manual
back to
start function menu
to switch to
next menu
to change
values
to store
values
basic menu
(w/o storing)
Print initialisation
Measure label ON/OFF
(when turning on the printer)
back to: "label length / gap width"
59
Interface manual
back to
start function menu
to switch to
next menu
to change
values
to store
values
basic menu
(w/o storing)
4. Printing mode
Continuous label ON/OFF
to 5.
Sensitivity
Ribbon control
(ON/OFF / weak/strong)
(weak – control rarely
strong – prompt reaction)
Dispensing mode
(OFF / I/O static / I/O dynamic / photocell /
I/O continuous static /
I/O continuous dynamic /
photocell continuous)
when in dispensing mode automatically with
back feed
Cutting mode
(OFF / with res. w/o back feed /
interval with res. w/o back feed /
end cut only)
Stacking mode
Scanner mode (ON/OFF)
Type of label photocell
(Transmission normal res. inverse,
reflexion normal res. inverse)
Print stop after 1 label ON/OFF
Label inverse
(ON, entry of width / OFF)
back to "Continuous label"
60
Interface manual
back to
start function menu
5. Sensitivity label photocell
to switch to
next menu
to change
values
to store
values
basic menu
(w/o storing)
to 6.
Interface
Sensitivity in % (2-118 %)
release
Values will be stored. It is recommended to
measure the label anew.
6. Interface
to 7.
Interface protocol
61
Interface manual
back to
start function menu
to switch to
next menu
to change
values
to store
values
basic menu
(w/o storing)
7. Interface protocol
to 8.
Paper counter
8. Paper counter
release
to 9.
Parameter of
photocell
Values shown in m *
* Setting of default values:
By pressing key C and entering the password 1003 all printer parameters will be set to default values.
The loaded labels will be automatically measured.
62
Interface manual
back to
start function menu
to switch to
next menu
to change
values
to store
values
basic menu
(w/o storing)
9. Parameter of photocell
to 10.
Interface test
Parameter:
A:
B:
C:
absolute minimum
smallest maximum
upper switching level
D: lower switching level
absolute maximum
values of 0 – 5 V
E:
Transmission photocell (Voltage)
Reflexion photocell (Voltage)
Dispensing photocell (Voltage)
Printhead temperature
Transfer ribbon photocell (hi / lo)
back to "A: absolute minimum ... "
63
Interface manual
back to
start function menu
to switch to
next menu
to change
values
to store
values
basic menu
(w/o storing)
11. Actual time / date
to 12.
Password
12. CV-Net
to 13.
Password
Define password
switch to next position with
Activate password protection
F: Function menu (0 = open / 1 = locked)
MC: Memory-Card
(0 = open / 1 = reading only /
2 = locked
E: Entry
(0 = open / 1 = only mask locked /
2 = locked)
D: Print function
(0= open / 1= entry of number of
pieces possible
2= no manual print release
64
Interface manual
back to
start function menu
to switch to
next menu
to change
values
to store
values
basic menu
(w/o storing)
B: User's guiding
(0 =
1=
OFF
ON, thereby automatically
MC = 1 / E = 2 / D = 1
2= same as 1, additionally the first
mask of the MC will be loaded)
65
Interface manual
19. Explanations
Turbo The advantage of using the "fast fonts" is the short generation time.
(fast) Fonts
width x height matrix position 0/2 position 1/3
51 = FONT 1 0,89 x 1,13 7x 9 w/o GEM w/o GEM
52 = FONT 2 1,25 x 1,75 10 x 14 with GEM w/o GEM
53 = FONT 3 1,89 x 2,63 15 x 21 with GEM w/o GEM
54 = FONT 4 4,00 x 5,63 32 x 45 w/o GEM w/o GEM
55 = FONT 5 1,89 x 3,25 15 x 26 descender with GEM w/o GEM
56 = FONT 6 1,75 x 2,87 14 x 23 OCR-A w/o GEM w/o GEM
57 = FONT 7 1,25 x 2,25 10 x 18 descender with GEM w/o GEM
Please note that the spaces have to be entered in mm and not in number of pixel.
The extension of these fonts always have to be y=1 and x=1.
If this is not observed, the regular fonts (incl. number of pixel as spaces) are being
generated. No error message is being displayed.
Vectorfonts When in mode "proportional text", the height and width of text have to be entered in
proportional: mm. These values refer to the capital "M", i.e. the values of other characters are
changing proportional.
Vectorfonts When in mode "autoscale" the height and width of the text has to be entered in
autoscale: mm. The height of the text refers to all capital letters. When using small characters
and descenders the height is changing proportional. When entering the width, the
complete file has to be considered. The text will be adjusted automatically, which
means that the width of the characters is changing.
66