Sunteți pe pagina 1din 3

COMBINED LOAD (ASD & LRFD Method)

Steel Section
Space at center
Dead Load to be supported
Live Load to be supported
Roof live, snow, or rain load
Wind Load
Eathquake
D
L
Lr or S or R
W
E

LRFD METHOD
Combination
1
2
3
4
5
6

Therefore, factored load governs for design is

D
L
Lr or S or R
W
E

ASD METHOD
Combination
1
2
3
4
5
6

7
8

Therefore, factored load governs for design is


COMBINED LOAD (ASD & LRFD Method)
W24 x 55
9 ft
40 psf
0 psf
30 psf
± 32 psf
0 psf
400 lb/ft
0 lb/ft
270 lb/ft
288 lb/ft
0 lb/ft

LRFD METHOD
Wu Result Unit
1.4D 560 lb/ft
1.2D + 1.6L + 0.5(Lr or S or R) 615 lb/ft
1.2D + 1.6(Lr or S or R) + (L or 0.5W) 1056 lb/ft
1.2D + 1.0W + L + 0.5(Lr or S or R) 903 lb/ft
1.2D + 1.0E + L + 0.2S 534 lb/ft
0.9D + 1.0(W) 648 lb/ft
0.9D + 1.0(-W) 72 lb/ft
0.9D + 1.0E 360 lb/ft

Therefore, factored load governs for design is 1056 lb/ft

400 lb/ft
0 lb/ft
270 lb/ft
300 lb/ft
0 lb/ft

ASD METHOD
Wa Result Unit
D 400 lb/ft
D+L 400 lb/ft
D + (Lr or S or R) 670 lb/ft
D + 0.75L + 0.75(Lr or S or R) 602.5 lb/ft
D + (0.6W or 0.7E) 580 lb/ft
D + 0.75L + 0.75(0.6W) + 0.75(Lr or S or R) 737.5 lb/ft
D + 0.75L + 0.75(0.75E) + 0.75(S) 602.5 lb/ft
0.6D + 0.6W 60 lb/ft
0.6D + 0.7E 240 lb/ft

Therefore, factored load governs for design is 737.5 lb/ft


LEGEND:
INPUT
OUTPUT
FINAL RESULT