Sunteți pe pagina 1din 4

T.

2 Viewing the de ection diagram


1. Select the Displacement page in Postprocessing page control bar.

Tip: This page is the default page when you open the Postprocessing work ow.

Note: You can display the De ection diagram on most results pages by selecting the De ection tool . The tool
remains depressed when the displacement is displayed.

The displacement diagram is drawn on the structure. The Node Displacements table and Beam Relative Displacement
Detail table open. See T.2 The Node Displacements Table for details on these tables.

2. (Optional) If the de ection is not exaggerated enough to clearly identify, you can change the scale:
a. On the Results ribbon tab, select the Scale tool in the Con guration group.

The Diagrams dialog opens displaying the Scales tab.

Tip: You can also open the Diagrams dialog by selecting the Structure tool or by right-clicking in the View area
and then selecting Structure Diagrams from the pop-up menu.

b. Change the Displacement value.

Tip: Smaller numbers exaggerate the de ected shape.

Type a value of 5 (mm per m) to clearly see the de ection due to load case 5.

c. Click Apply.

Tip: You can set the Apply Immediately option on this tab to view the scale change as you use the up/down
arrows in the Displacement eld.

d. Click OK.

3. To change the load case being displayed, select from the current Load list in the window status bar.

Tip: Alternatively, select the Structure tool in the Con guration group on the Results toolbar. The active load
case can be selected on the Load and Results tab in the Diagrams dialog.

The results displayed are for the selected load case only.

Select 5: DEAD + WIND for this tutorial.


/
4. Annotate the de ection at speci c nodes:
a. On the Results ribbon tab, select the Annotate tool in the Con guration group.

The Annotation dialog opens.


b. On the Ranges tab, select the Ranges option and then type 2 3 6 (spaced node number list) in the Nodes eld.

c. Select the Node tab and then check the Resultant option.

Resultant stands for the square root of sum of squares of values of X, Y and Z displacements.

d. Click Annotate and then click Close.


/
The structure de ection diagram is annotated for load case 5, as in the following gure.

5. Change the display units for displacement: The units in which displacement values are displayed in the post-
processing mode are referred to as the display units.
a. On the File ribbon tab, select Display Options on the Settings tab.

The Options dialog opens.

b. Select the Structure Units tab.

c. Change Displacement selection from mm (millimeter) to cm (centimeter).

/
d. Click OK.

The diagram will be updated to re ect the new units.