Sunteți pe pagina 1din 24

Inspection chambers

Standard inspection chambers with monolithic structure


e Warra
len Komfort-inspection chambers with modular structure
nt
Polyethy

rs y

2 0 Y ea

Control wastewater
Standard inspection chambers and
Standard inspection chambers GT ... 160/161
Standard inspection chambers with monolithic structure

Ø 1000

Monolith one-piece Standard inspection chambers ........ 162/163


chamber - saves time with integrated upper section
Ø 1000
and money
Vario inspection chambers and
Vario inspection chambers GT ................ 164
Ø 1000

Pump inspection chambers and


Pump inspection chambers GT ............... 165
Ø 1000

Standard inspection chambers and


Standard inspection chambers GT .......... 166
Ø 1000, with closed base

Standard inspection chambers ............... 167


Ø 600

Polymer manhole extension rings ........... 169

Street gullies Ø 400 ................................ 170


Komfort-inspection chambers with modular structure

Sectional chamber -
for quick and easy
on-site assembly
Clean out Controlfix ® ........................ 172/173
in Komfort inspection chamber system
Ø 800 and Ø 1000

Modular System Ø 1000 ................... 174/175

Komfort inspection chambers .......... 176/177


Ø 400

Modular System Ø 400 .................... 178/179

158 Catalogue 2.2


Polyeth

y l ene Warra

2 0 Y ear
s n ty

Catalogue 2.2
159
with monolithic structure
Standard inspection chambers

Komfort-inspection chambers with modular structure Standard inspection chambers with monolithic structure
Variable upper section
as accessories:
Standard inspection chambers and
inclinable
standard inspection chambers GT Ø 1000 height adjustable

Illustration and dimensioned drawing Article description


Standard inspection chambers with monolithic structure

Standard inspection chamber and


Standard cover on-site standard inspection chamber GT Ø 1000
polyethylene inspection chamber
with open channel passage Ø .....

Installation depths D from 1245 to 3510 mm possible


Accessories: Art. # 860 125/860 116 with/without ..... lateral inlet(s) Ø ..... (.....°) in flow direction
For underground installation
Installation depth D ....... mm,

50 to 550 mm
Inspection chamber height H ....... mm,
with monolithic structure, water-tight, resistant against
Inspection chamber aggressive wastewater, with integrated access steps,
includes temporary with polyethylene temporary construction debris cover
construction (can be used as a cover in green areas if there is sufficient
debris cover protection against unauthorised opening).

Chamber height H 1 to H 5
Inlet/outlet with spigot end for connection for
PVC pipe Ø .../... according to DIN 19534 and
PE-HD pipe Ø .../... according to DIN 19537.

Handles groundwater depths up to 1000 mm


Accessories
Page 168
ca. 1600 333
Certification no. Z-42.1-333

Chamber Standard inspection chamber Chamber Standard inspection chamber GT


height Ø 110/125 Ø 160/200 Ø 250/315 Ø 400 height Ø 160/200 Ø 250/315 Ø 400
H1 1040 mm 1070 mm 1250 mm 1250 mm H1 1245 mm 1425 mm 1425 mm
H2 1540 mm 1570 mm 1750 mm 1750 mm H2 1745 mm 1925 mm 1925 mm
H3 2040 mm 2070 mm 2250 mm 2250 mm H3 2245 mm 2425 mm 2425 mm
H4 2540 mm 2570 mm 2750 mm 2750 mm H4 2745 mm 2925 mm 2925 mm
H5 3040 mm 3070 mm - - H5 3245 mm - -

Wear coating approx. 3 cm


Installation suggestion Class D
Asphalt base layer
approx. 8-12 cm Standard inspection chamber GT Ø 1000,
Binding layer inspection chamber height H 1 to H 5
KESSEL Upper section in synthetic material:
Frost blanket of gravel adjustable in height from 50 to max. 550 mm
approx. 25 - 30 cm
Standard concrete rings for height-
compensation
Komfort-inspection chambers with modular structure

min. 50 cm ballast 0/32


Standard manhole cover

Ground
Ordering overview, upper sections,
covers and gaskets see page 168

Chippings

Upper section Upper section


with cover plate for manhole cover

Inspection chamber version GT - for durability when installed in groundwater 2.5 m above the base !

Additional buoyancy protection Advanced safety


The standard inspection A completely new feature: safe access
chamber GT is provided steps in the standard inspection chamber
in the lower region with GT. The safe access steps in corrosion-
an additional buoyancy resistant PE-HD in yellow marker paint
protection ring (with con- prevent slipping and can be gripped for a
tact surfaces for water safer hold when accessing the inspection
level). chamber.
Entering and exiting is now even safer - GT chamber offers an additional
access step in upper portion of chamber.

160 Catalogue 2.2


Standard inspection chambers and
standard inspection chambers GT Ø 1000
Ordering overview Art. # Standard inspection chamber Art. # Standard inspection chamber GT

Standard inspection chambers with monolithic structure


Channel passage
Chamber
Flow direction height Ø 160/200 Ø 250/315 Ø 400 Ø 160/200 Ø 250/315 Ø 400
H 1 88 10 10 88 10 11 88 10 12 88 010 10 88 010 11 88 010 12
H 2 88 15 10 88 15 11 88 15 12 88 015 10 88 015 11 88 015 12
H 3 88 20 10 88 20 11 88 20 12 88 020 10 88 020 11 88 020 12
H 4 88 25 10 88 25 11 88 25 12 88 025 10 88 025 11 88 025 12
H 5 88 30 10 - - 88 030 10 - -
Channel passage with two lateral inlets (45°)
Chamber
height Ø 110/125 Ø 160/200 Ø 250/315 Ø 160/200 Ø 250/315
H 1 88 10 02 88 10 00 88 10 01 88 010 00 88 010 01
H 2 88 15 02 88 15 00 88 15 01 88 015 00 88 015 01
H 3 88 20 02 88 20 00 88 20 01 88 020 00 88 020 01
H 4 88 25 02 88 25 00 88 25 01 88 025 00 88 025 01
H 5 88 30 02 88 30 00 - 88 030 00 -
Channel passage with one lateral inlet (45°) on the right or left
Chamber
height Ø 160/200 right Ø 160/200 left Ø 160/200 right Ø 160/200 left
H 1 88 10 20 88 10 30 88 010 20 88 010 30
H 2 88 15 20 88 15 30 88 015 20 88 015 30
H 3 88 20 20 88 20 30 88 020 20 88 020 30
H 4 88 25 20 88 25 30 88 025 20 88 025 30
H 5 88 30 20 88 30 30 88 030 20 88 030 30
Channel passage (Ø 200) with one lateral inlet (90°) in Ø 160 right or left; inlet Ø 200 available on request
Chamber
height Ø 160/200 right Ø 160/200 left Ø 160/200 right Ø 160/200 left
H 1 88 10 40 88 10 50 88 010 40 88 010 50
H 2 88 15 40 88 15 50 88 015 40 88 015 50
H 3 88 20 40 88 20 50 88 020 40 88 020 50
H 4 88 25 40 88 25 50 88 025 40 88 025 50
H 5 88 30 40 88 30 50 88 030 40 88 030 50
Curved channel (90°) bent to the right or left

Komfort-inspection chambers with modular structure


Chamber
height Ø 200 right Ø 200 left Ø 200 right Ø 200 left
H 1 88 10 70 88 10 60 88 010 70 88 010 60
H 2 88 15 70 88 15 60 88 015 70 88 015 60
H 3 88 20 70 88 20 60 88 020 70 88 020 60
H 4 88 25 70 88 25 60 88 025 70 88 025 60
H 5 88 30 70 88 30 60 88 030 70 88 030 60

Open channel passage, can be retrofitted with backwater valves


Chamber
height Ø 160/200 Art. # Ø 160/200 Art. #
H 1 1100 mm 88 10 04 1275 mm 88 010 04
H 2 1600 mm 88 15 04 1775 mm 88 015 04
H 3 2100 mm 88 20 04 2275 mm 88 020 04
H 4 2600 mm 88 25 04 2775 mm 88 025 04
H 5 3100 mm 88 30 04 3275 mm 88 030 04

Catalogue 2.2 161


Standard inspection chambers with integrated upper section Ø 1000
Illustration and dimensioned drawing Article description
Standard inspection chambers with monolithic structure

Standard inspection chamber


with integrated upper section Ø 1000
On-site sourced cover
polyethylene inspection chamber
with open channel passage Ø .....
with/without ..... lateral inlet(s) Ø ..... (.....°) in flow direction
Inspection chamber For underground installation
includes upper Installation depth D ....... mm,

500
section which Inspection chamber height H ....... mm,

of 1195 to 3405 mm possible


with monolithic structure, water-tight, resistant against

Chamber height H 1 to H 4
can be sawn
off to length aggressive wastewater, with integrated access steps,

Installation depths D
with polyethylene temporary construction debris cover (can be
used as a cover in green areas if there is sufficient protection
against unauthorised opening).
Inlet/outlet with spigot end for connection for
PVC pipe Ø .../... according to DIN 19534 and
PE-HD pipe Ø .../... according to DIN 19537.
Other dimensions on demand
Handles groundwater depths up to 1000 mm
783 780 Accessories
Page 168
Upper section can be sawn off
by up to 500 mm 333
Certification no. Z-42.1-333

With open channel passages... (Article overview page 163) Inspection chamber with closed base
Chamber Standard inspection chamber * Standard inspection chamber
height Ø 110/125 Ø 160/200 Ø 250/315 Ø 400 Chamber height Volumes Art. #
H1 1040 - 1540 1070 - 1570 1250 - 1750 1250 - 1750 H1 1050 - 1550 700 l 88 310 08
H2 1540- 2040 1570 - 2070 1750 - 2250 1750 - 2250 H2 1550- 2050 1200 l 88 315 08
H3 2040- 2540 2070 - 2570 2250 - 2750 2250 - 2750 H3 2050- 2550 1650 l 88 320 08
H4 2540- 3040 2570 - 3070 2750 - 3250 2750 - 3250 H4 2550- 3050 2100 l 88 325 08
* Other dimensions on demand

Vario inspection chamber with freely selectable inlets Pump inspection chamber for one or two pumps
Channel type: Chamber Vario inspection chamber ** Pump chamber Art. # for
Flow direction height Ø 160/200 Art. # Chamber height 1 Pump 2 Pumps
H1 1200 - 1700 88 310 90 H1 1100 - 1600 87 310 10 87 310 20
Komfort-inspection chambers with modular structure

H2 1700 - 2200 88 315 90 H2 1600- 2100 87 315 10 87 315 20


H3 2200 - 2700 88 320 90 H3 2100- 2600 87 320 10 87 320 20
H4 2700 - 3200 88 325 90 H4 2600- 3100 87 325 10 87 325 20
** Outlet also Ø 250 and Ø 300 available on request
Version for Version for
one pump two pumps
Dual inspection chamber with open channel passage
Channel type: Chamber Dual inspection chamber ***
Flow direction height Ø 160/200 Ø 250/315 Ø 400
H1 1070 - 1570 1250 - 1750 1250 - 1750
H2 1570 - 2070 1750 - 2250 1750 - 2250
H3 2070 - 2570 2250 - 2750 2250 - 2750
H4 2570 - 3070 2750 - 3250 2750 - 3250
*** Object-related closed pipe design

162 Catalogue 2.2


Standard inspection chambers with integrated upper section Ø 1000
Ordering overview Art. # Standard inspection chamber

Standard inspection chambers with monolithic structure


Channel passage
Chamber
Flow direction height Ø 160/200 Ø 250/315 Ø 400
H1 88 310 10 88 310 11 88 310 12
H2 88 315 10 88 315 11 88 315 12
H3 88 320 10 88 320 11 88 320 12
H4 88 325 10 - -

Channel passage with two lateral inlets (45°)


Chamber
height Ø 110/125 Ø 160/200 Ø 250/315
H1 88 310 02 88 310 00 88 310 01
H2 88 315 02 88 315 00 88 315 01
H3 88 320 02 88 320 00 88 320 01
H4 88 325 02 88 325 00 -

Channel passage with one lateral inlet (45°) on the right or left
Chamber
height Ø 160/200 right Ø 160/200 left
H1 88 310 20 88 310 30
H2 88 315 20 88 315 30
H3 88 320 20 88 320 30
H4 88 325 20 88 325 30

Channel passage (Ø 200) with one lateral inlet (90°) in Ø 160 right or left; inlet Ø 200 available on request
Chamber
height Ø 160/200 right Ø 160/200 left
H1 88 310 40 88 310 50
H2 88 315 40 88 315 50
H3 88 320 40 88 320 50
H4 88 325 40 88 325 50

Curved channel (90°) bent to the right or left

Komfort-inspection chambers with modular structure


Chamber
height Ø 200 right Ø 200 left
H1 88 310 70 88 310 60
H2 88 315 70 88 315 60
H3 88 320 70 88 320 60
H4 88 325 70 88 325 60

Open channel passage, can be retrofitted with backwater valves


Chamber Backwater inspection chamber
height Ø 160/200 Art. #
H1 1100 mm 88 310 04
H2 1600 mm 88 315 04
H3 2100 mm 88 320 04
H4 2600 mm 88 325 04

Catalogue 2.2 163


Variable upper section
as accessories:
inclinable
Vario inspection chambers and Vario inspection chambers GT Ø 1000 height adjustable

Illustration and dimensioned drawing Article description


Standard inspection chambers with monolithic structure

Vario inspection chamber and

Installation depths D for Vario inspection chamber GT +175 mm


Standard cover on-site
Vario inspection chamber GT Ø 1000
polyethylene inspection chamber
with freely selectable inlets (Ø 110 - Ø 250)

Installation depths D from 1375 to 3140 mm possible


Accessories: Art. # 860 125/860 116
For underground installation
Installation depth D ....... mm,

50 to 550 mm
Inspection chamber height H ....... mm,
with monolithic structure, water-tight, resistant against
Inspection chamber aggressive wastewater, with integrated access steps, with
includes temporary telescopically height adjustable protective cover for use
construction during construction, in synthetic material (can be used as a
debris cover cover in green areas if there is sufficient portection against
unauthorised opening).

Chamber height H 1 to H 4
Inlets can be drilled on-site in any manner in flow direction
left and right up to 90°.
Outlet Ø 160/200 (Ø 250 and Ø 315 available on request).
Inlet/outlet with spigot end to the connection for
PVC pipe Ø 160/200 according to DIN 19534 and
PE-HD pipe Ø 160/200 according to DIN 19537.

Handles groundwater depths up to 1000 mm

550 634
Accessories
Page 168

Channel type: Chamber Vario chamber * Chamber Vario chamber GT * Ordering overview, upper sections,
height Ø 160/200 Art. # height Ø 160/200 Art. # covers and gaskets see page 168
H1 1200 mm 88 10 90 H1 1375 mm 88 010 90
H2 1700 mm 88 15 90 H2 1875 mm 88 015 90
H3 2200 mm 88 20 90 H3 2375 mm 88 020 90
H4 2700 mm 88 25 90 H4 2875 mm 88 025 90
Flow direction *Outlet also Ø 250 and Ø 300 available on request Upper section Upper section
with cover plate for manhole cover

Pipe sealing gasket Hole saws


Delivery without inlet:
Inlets can be drilled on-site in
any manner in flow direction Ø 110 Art. # 850 117 Ø 50 - 160 Art. # 50 100
Komfort-inspection chambers with modular structure

left and right up to 90°. Ø 125 Art. # 850 118 Ø 200* Art. # 50 102
Hole saws and gaskets for pipe Ø 160 Art. # 850 119 Ø 250* Art. # 50 103
conduit see table.
Ø 200 Art. # 182-875 *Recommended for drills
Ø 250 Art. # 182-879 with minimum 1000 W.

Inspection chamber version GT - for durability when installed in groundwater 2.5 m above the base !

Additional buoyancy protection Advanced safety


The standard inspection A completely new feature: safe access
chamber GT is provided steps in the standard inspection chamber
in the lower region with GT. The safe access steps in corrosion-
an additional buoyancy resistant PE-HD in yellow marker paint
protection ring (with con- prevent slipping and can be gripped for a
tact surfaces for spirit safer hold when accessing the inspection
levels). chamber.
Entering and exiting is now even safer - GT chamber offers an additional
access step in upper portion of chamber.

164 Catalogue 2.2


Variable upper section
as accessories:
inclinable
Pump inspection chambers and Pump inspection chambers GT Ø 1000 height adjustable

Illustration and dimensioned drawing Article description

Standard inspection chambers with monolithic structure


Pump inspection chamber and
Standard cover on-site Pump inspection chamber GT Ø 1000
in polyethylene,
for on-site installation of up to two pumping systems.
For underground installation

Installation depths D from 1225 to 3490 mm possible


Accessories: Art. # 860 125/860 116
Installation depth D ....... mm,
Inspection chamber height H ....... mm,
with monolithic structure, water-tight, resistant against

from 50 to 550 mm
aggressive wastewater, with telescopically height adjustable
protective cover for use during construction, in synthetic
material (can be used as a cover in green areas if there is
Inspection chamber sufficient protection against unauthorised opening).
includes temporary
construction Handles groundwater depths up to 500 mm
debris cover

Chamber height H 1to H 5


Accessories
Page 168

1100
333
Certification no. Z-42.1-333

Pump chamber for Pump chamber GT for


Chamber height 1 Pump 2 Pumps Chamber height 1 Pump 2 Pumps
Art. # Art. # Art. # Art. #
H 1 1100 mm 87 10 10 87 10 20 H 1 1275 mm 87 010 10 87 010 20
H 2 1600 mm 87 15 10 87 15 20 H 2 1775 mm 87 015 10 87 015 20
H 3 2100 mm 87 20 10 87 20 20 H 3 2275 mm 87 020 10 87 020 20
H 4 2600 mm 87 25 10 87 25 20 H 4 2775 mm 87 025 10 87 025 20
H 5 3100 mm 87 30 10 87 30 20 H 5 3275 mm 87 030 10 87 030 20

Version for one pump Version for two pumps Ordering overview, upper sections,
covers and gaskets see page 168

Komfort-inspection chambers with modular structure


Upper Upper
section with section for
cover plate manhole cover

Additional buoyancy protection Advanced safety


The pump chamber GT A completely new feature: safe access
has an additional buoy- steps in the pump chamber GT. The safe
ancy prevention ring in access steps in corrosion-resistant PE-HD
the lower region (with in yellow marker paint prevent slipping and
contact surfaces for can be gripped for a safer hold when
water level). accessing the inspection chamber.

Entering and exiting is now even safer - GT chamber offers an additional


access step in upper portion of chamber.

Catalogue 2.2 165


Standard inspection chambers and Variable upper section
as accessories:
Standard inspection chambers GT Ø 1000
inclinable
with closed base height adjustable

Illustration and dimensioned drawing Article description


Standard inspection chambers with monolithic structure

Standard inspection chamber and


Standard cover on-site Standard inspection chamber GT Ø 1000
in polyethylene,
with closed base
For underground installation

Installation depths D from 1225 to 3490 mm possible


Accessories: Art. # 860125/860116
Installation depth D ....... mm,
Inspection chamber height H ....... mm, with monolithic
structure, water-tight, resistant against aggressive wastewa-

from 50 to 550 mm
ter, with integrated access steps, with telescopically height
adjustable protective cover for use during construction, in
synthetic material (can be used as a cover in green areas if
Inspection chamber there is sufficient protection against unauthorised opening).
includes temporary Art. # ...............
construction
debris cover Handles groundwater depths up to 500 mm

Chamber height H 1 to H 4
Accessories
Page 168

1100

Chamber height Standard chamber Chamber height Standard chamber GT Ordering overview, upper
Art. # Volumes Art. # Volumes sections see page 168
H 1 1050 mm 88 10 08 700 l H 1 1225 mm 88 010 08 800 l
H 2 1550 mm 88 15 08 1200 l H 2 1725 mm 88 015 08 1300 l
H 3 2050 mm 88 20 08 1650 l H 3 2225 mm 88 020 08 1700 l
H 4 2550 mm 88 25 08 2100 l H 4 2725 mm 88 025 08 2200 l
with for
H 5 3050 mm 88 30 08 2550 l H 5 3225 mm 88 030 08 2600 l cover plate manhole cover

Additional buoyancy protection Advanced safety


Komfort-inspection chambers with modular structure

The standard inspection A completely new feature: safe access


chamber GT has an addi- steps in the standard inspection chamber
tional buoyancy preventi- GT. The safe access steps in corrosion-
on ring in the lower regi- resistant PE-HD in yellow marker paint
on (with contact surfaces prevent slipping and can be gripped for a
for water level). safer hold when accessing the inspection
chamber.
Entering and exiting is now even safer - GT chamber offers an additional
access step in upper portion of chamber.

166 Catalogue 2.2


Variable upper section
as accessories:
inclinable
Standard inspection chambers Ø 600 height adjustable

Illustration and dimensioned drawing Article description

Standard inspection chambers with monolithic structure


Standard cover on-site Standard inspection chamber Ø 600
in polyethylene,
with open channel passage in PP Ø .....

Installation depths D from 1275 to 3540 mm possible


Accessories: Art. # 860 125/860 116 For underground installation
Installation depth D ....... mm,
Inspection chamber height H ....... mm,

50 to 550 mm
in monolithic structure, water-tight, resistant to aggressive
wastewater, with outlet Ø ...... with/without two lateral inlets
Inspection chamber left and right 45° in flow direction.
includes temporary Connection of PVC pipe according to DIN 19534
construction and PE-HD pipe according to DIN 19537.

Chamber height H 1 to H 5
debris cover Vario-Version on demand

Handles groundwater depths up to 1000 mm

Accessories
Page 168
L * (see page 179)
L*

Channel type: Channel type:

Flow direction Flow direction

Chamber Channel passage Chamber Channel with 3 inlets


height Ø 160 Ø 200 Ø 250 height Ø 160/160 Ø 160/200 Ø 200/200 Ø 200/250
H 1 950 mm 1000 mm 1040 mm H1 950 mm 950 mm 1000 mm 1000 mm
H 2 1450 mm 1500 mm 1540 mm H2 1450 mm 1450 mm 1500 mm 1500 mm
H 3 1950 mm 2000 mm 2040 mm H3 1950 mm 1950 mm 2000 mm 2000 mm
H 4 2450 mm 2500 mm 2540 mm H4 2450 mm 2450 mm 2500 mm 2500 mm
H 5 2950 mm 3000 mm 3040 mm H5 2950 mm 2950 mm 3000 mm 3000 mm

Art. # Channel passage Art. # Channel with 3 inlets

Chamber Chamber
height Ø 160 Ø 200 Ø 250 height Ø 160/160 Ø 160/200 Ø 200/200 Ø 200/250

Komfort-inspection chambers with modular structure


H 1 82 10 15 82 10 20 82 10 25 H 1 82 10 16 82 10 17 82 10 21 82 10 22
H 2 82 15 15 82 15 20 82 15 25 H 2 82 15 16 82 15 17 82 15 21 82 15 22
H 3 82 20 15 82 20 20 82 20 25 H 3 82 20 16 82 20 17 82 20 21 82 20 22
H 4 82 25 15 82 25 20 82 25 25 H 4 82 25 16 82 25 17 82 25 21 82 25 22
H 5 82 30 15 82 30 20 82 30 25 H 5 82 30 16 82 30 17 82 30 21 82 30 22

Ø 1000 Ø 600 Ø 600 Ø 600

Catalogue 2.2 167


Accessories
KESSEL polymer extension section Complete KESSEL polymer extension section
for standard concrete rings/manhole covers for load classes B/D
for load classes B/D
Standard inspection chambers with monolithic structure

Article Art. #
Cover plate in cast iron
Standard manhole cover with ventilation,
in cast iron Class A 860 134
Further assembly possible using Class B 860 135
additional concrete rings Class D, locked 860 137
Class B: H = 125 mm
Cover plate in cast iron
Class D: H = 160 mm
Class A, locked 860 132
Standard bearing ring Class B, locked 860 133
(anti-slip; AR-V) Class D, locked 860 136
H = 30, 50, 100, 120 ...... mm
Cover plate
Polymer manhole extension rings in cast iron
see page 169 Class A 860 130
Class B 860 131
Sludge bucket
Class A/B 860 115
Class D 860 115-D
Article Art. #
Article Art. #
Polymer extension section
Polymer extension section 860 120
for standard bearing ring/
with clamping ring, telescopic
manhole covers
height adjustable from 100 to
can be assembled using
550 mm, for cover Class B/D,
standard concrete rings;
with cut-outs for
telescopic height adjustable
sludge bucket
from 50 to 280 mm
860 122 Polymer extension section 860 121
with clamping ring, telescopic
telescopic height adjustable height adjustable from 100 to
from 50 to 550 mm 860 125 550 mm, for cover Class B,
locked, without holders for
sludge bucket

Article Art. # Article Art. #


Lip gasket Ø 600 860 116 Lip gasket Ø 600 860 116
Komfort-inspection chambers with modular structure

Calculation for installation depth D Calculation for installation depth D

Inspection chamber height H 1 to H 5


Height of extension section Inspection chamber height H 1 to H 5
from 50 - 280 mm (50 - 550 mm) Height of extension section
Height of concrete ring/ from 100 to 550 mm
manhole cover Cover plate

168 Catalogue 2.2


Polymer manhole extension rings
Illustration and dimensioned drawing Article description Art. #

Standard inspection chambers with monolithic structure


KESSEL manhole extension 860 145
ring H 10 *

13
Height: 10 mm, weight: 1.9 kg 50 pcs/pal.
쏗786
쏗612

KESSEL manhole extension 860 146


ring H 20 *

20
Height: 20 mm, weight: 2.0 kg 50 pcs/pal.
쏗792
쏗612

KESSEL manhole extension 860 147


ring H 50 *
쏗625
Height: 50 mm, weight: 5.3 kg 20 pcs/pal.
쏗865
50

KESSEL manhole extension 860 148


쏗625 ring H 80 *
Height: 80 mm, weight: 7.3 kg 12 pcs/pal.
쏗865
80

KESSEL manhole extension 860 149


쏗625
ring H 100 *
Height: 100 mm, weight: 8.7 kg 10 pcs/pal.
쏗865
100

Komfort-inspection chambers with modular structure


Standard commercial
manhole cover

KESSEL H 10 extension ring *


KESSEL H 20 extension ring *
KESSEL H 50 extension ring *
KESSEL H 80 extension ring * Concrete manhole rings often show up on the job site
already damaged or destroyed. The real expense comes
KESSEL H 100 extension ring * when the chambers fail the final inspection and rings
need to be repaired or replaced. This could result in
removing the asphalt surface, reparing or replacing the
damaged concrete ring and then re-asphalting the sur-
Concrete manhole
face – an additional cost of at least 300 Euro.

The difficult installation and risk of replacing damaged


concrete rings can all be prevented by the use of the
new KESSEL polymer ring. The shatter proof and long
* extension rings can be combined
lasting KESSEL polymer rings prevent damage during
up to max.height of 250 mm storage, transport and installation.

Catalogue 2.2 169


Street gullies Ø 400
Illustration Article description
Standard inspection chambers with monolithic structure

Standard
Street gullies Ø 400
manhole cover in polyethylene
햲 on-site For underground installation
Installation depth (D) 573 mm to 785 mm
(Height without manhole upper section),
Upper section

Installation depths from 573 to 825 mm possible


with monolithic structure, resistant against aggressive

Chamber height 573-785 mm 10 - 100 mm


wastewater, frost and de-icing salts,
Lip seal with outlet Ø 160 suitable for connection of PVC pipe
according to DIN 19534 and PE-HD pipe according to
Inspection DIN 19537
chamber
햲 with lateral outlet couplings Ø 160; 10°
Accessories: With upper section 50 x 50 cm: Art. #: 81 10 10
Rodent protecti-
on flap With upper section 30 x 50 cm: Art. #: 81 10 11
with lateral outlet couplings Ø 160; 0°
With upper section 50 x 50 cm: Art. #: 81 10 40
With upper section 30 x 50 cm: Art. #: 81 10 41
햳 with lateral outlet couplings Ø 160 / 200 / 250; 2°
햳 With upper section 50 x 50 cm: Art. #: 81 10 30
With upper section 30 x 50 cm: Art. #: 81 10 31

Standard
Street gullies
manhole cover with wet sludge trap Ø 400
on-site in polyethylene,
with lateral outlet couplings Ø 160
For underground installation
Upper section Installation depth (D) 1085 mm to 1296 mm
10 - 100 mm

(Height without manhole upper section),


Installation depths from 1085 to 1336 mm possible

Lip seal with monolithic structure, resistant against aggressive


wastewater, frost and de-icing salts,
Inspection with outlet Ø 160 suitable for connection of
chamber PVC pipe according to DIN 19534 and
PE-HD pipe according to DIN 19537
Chamber height 1085 - 1296 mm

Accessories:
Rodent protecti- with lateral outlet couplings Ø 160; 10°
on flap
With upper section 50 x 50 cm: Art. #: 81 10 20
With upper section 30 x 50 cm: Art. #: 81 10 21
with lateral outlet couplings Ø 160; 0°
Komfort-inspection chambers with modular structure

With upper section 50 x 50 cm: Art. #: 81 10 60


With upper section 30 x 50 cm: Art. #: 81 10 61

Illustration shows Art. # 81 10 20

Accessories

Illustration Article description Art. #

Lip seal
suitable for street gullies 81 10 51

Rodent protection flap


suitable for street gullies 81 10 50

170 Catalogue 2.2


Polyeth

y l ene Warra

2 0 Y ear
s n ty

Catalogue 2.2
171
with modular structure
Komfort-inspection chamber

Komfort-inspection chambers with modular structure Standard inspection chambers with monolithic structure
Clean out Controlfix ® Variable upper section:
in the Komfort-Inspection chamber System Ø 800 and Ø 1000 inclinable
height adjustable
according to EN 752 for underground installation vehicle traffic proof
Illustration Article description
Standard inspection chambers with monolithic structure

Clean out Controlfix ®


in the Komfort inspection chamber Ø...
Polyethylene construction,
for underground installation
Installation depth (D) from ..... mm to ..... mm
Inclusive integrated access steps (with Ø 1000), water-tight,
resistant to aggressive wastewater. Extension section
made of polymer for continuous height and level adjustment.
Optional cover plate class ..... in cast iron according
to EN 124, surface water tight, incl. cover removal tool.
Continuous pipe Ø .....
with cleaning pipe according to EN 13564.
Inlets with flange, outlet with spigot end for PVC pipe
according to DIN 19534 and PE-HD pipe according
to DIN 19537.
Conversion center inlet pipe to bottom inlet pipe:
Ø 110: Installation depth D + 55 mm
Ø 125: Installation depth D + 62.5 mm
Ø 160: Installation depth D + 80 mm
Delivery:
Inspection chamber in components (bottom parts stackable)
for on-site assembly incl. assembly system.

Handles groundwater depths up to 500 mm

Installation depth D: Cover-upper edge to Easy conversion:


outlet-pipe center Conversion kit
Pumpfix ® F Komfort / Standard

Conversion kit
Staufix ® FKA Komfort / Standard
D

Conversion kit
Staufix ® SWA

Accessories

Illustration Article description Outer diameter Art. #


Ø (mm)
Komfort-inspection chambers with modular structure

Conversion kit Pumpfix ® F


For conversion to the Komfort inspection chamber
with backwater pumping station Pumpfix ® F,
for wastewater with or without sewage With 5 m cable length:
Pumpfix ® F Komfort incl. Komfort control unit Ø 110 - Ø 200 80 097
Pumpfix ® F Standard incl. Standard control unit Ø 110 - Ø 200 80 096
Cable extension set for pump, motor and probe
see page 22
Conversion kit Staufix ® FKA
For conversion to the Komfort inspection chamber
with backwater valve Staufix ® FKA,
for wastewater with or without sewage With 5 m cable length:
Staufix ® FKA Komfort incl. Komfort control unit Ø 110 - Ø 200 80 093
Staufix ® FKA Standard incl. Standard control unit Ø 110 - Ø 200 80 092
Cable extension set for motor and probe see page 22
Conversion kit Staufix ® SWA Ø 110 - Ø 200 80 091
For conversion to the Komfort inspection chamber
with backwater valve Staufix ® SWA,
for wastewater without sewage

Cable piping gasket set Ø 110 85 410


Further installation depths (Ø 1000) up to a max. installation depth of 5 m can be individually created via the accessory parts, on request.
Cable piping is to be provided to enable subsequent retrofitting (Set Art. # 85 410).

172 Catalogue 2.2


Clean out Controlfix ®
in the Komfort-Inspection chamber System Ø 800 and Ø 1000
according to EN 752 for underground installation
Ø 800 Ø 1000
Channel

Standard inspection chambers with monolithic structure


type Installation depth Art. # Installation depth Art. #
Ø* Ø*
D in mm Class A/B Class D D in mm Class A/B Class D
1 Continuous pipe: 1 Continuous pipe (Ø 200 available on request):
D 1: Ø 110 84 21 01 B 84 21 01 D D 1: Ø 110 86 21 01 B 86 21 01 D
Ø 125 84 21 02 B 84 21 02 D Ø 125 86 21 02 B 86 21 02 D
770 - 1270 mm Ø 160 84 21 03 B 84 21 03 D 950 - 1450 mm Ø 160 86 21 03 B 86 21 03 D
D 2: Ø 110 84 21 11 B 84 21 11 D D 2: Ø 110 86 21 11 B 86 21 11 D
Ø 125 84 21 12 B 84 21 12 D Ø 125 86 21 12 B 86 21 12 D
1270 - 1770 mm Ø 160 84 21 13 B 84 21 13 D 1450 - 1950 mm Ø 160 86 21 13 B 86 21 13 D
Channel
example
D 3: Ø 110 84 21 21 B 84 21 21 D D 3: Ø 110 86 21 21 B 86 21 21 D
Ø 1000 Ø 125 84 21 22 B 84 21 22 D Ø 125 86 21 22 B 86 21 22 D
1770 - 2270 mm Ø 160 84 21 23 B 84 21 23 D 1950 - 2450 mm Ø 160 86 21 23 B 86 21 23 D
D 4: Ø 110 84 21 31 B 84 21 31 D D 4: Ø 110 86 21 31 B 86 21 31 D
Ø 125 84 21 32 B 84 21 32 D Ø 125 86 21 32 B 86 21 32 D
2270 - 2770 mm Ø 160 84 21 33 B 84 21 33 D 2450 - 2950 mm Ø 160 86 21 33 B 86 21 33 D
D 5: Ø 110 84 21 41 B 84 21 41 D D 5: Ø 110 86 21 41 B 86 21 41 D
Ø 125 84 21 42 B 84 21 42 D Ø 125 86 21 42 B 86 21 42 D
2770 - 3270 mm Ø 160 84 21 43 B 84 21 43 D 2950 - 3450 mm Ø 160 86 21 43 B 86 21 43 D
2 An inlet in flow direction right 90°:
D 1: Ø 110 86 22 01 B 86 22 01 D
Ø 125 86 22 02 B 86 22 02 D
950 - 1450 mm Ø 160 86 22 03 B 86 22 03 D
D 2: Ø 110 86 22 11 B 86 22 11 D
Ø 125 86 22 12 B 86 22 12 D
1450 - 1950 mm Ø 160 86 22 13 B 86 22 13 D
Channel Ø 110 86 22 21 B 86 22 21 D
example D 3:
Ø 125 86 22 22 B 86 22 22 D
Ø 1000 1950 - 2450 mm Ø 160 86 22 23 B 86 22 23 D
D 4: Ø 110 86 22 31 B 86 22 31 D
Ø 125 86 22 32 B 86 22 32 D
2450 - 2950 mm Ø 160 86 22 33 B 86 22 33 D
D 5: Ø 110 86 22 41 B 86 22 41 D
Ø 125 86 22 42 B 86 22 42 D
2950 - 3450 mm Ø 160 86 22 43 B 86 22 43 D
3 An inlet in flow direction left 90°:
D 1: Ø 110 86 23 01 B 86 23 01 D
Ø 125 86 23 02 B 86 23 02 D
950 - 1450 mm Ø 160 86 23 03 B 86 23 03 D
842311 B D 2: Ø 110 86 23 11 B 86 23 11 D
842312 B Ø 125 86 23 12 B 86 23 12 D
1450 - 1950 mm Ø 160 86 23 13 B 86 23 13 D

Komfort-inspection chambers with modular structure


Channel Ø 110 86 23 21 B 86 23 21 D
example D 3:
Ø 125 86 23 22 B 86 23 22 D
Ø 1000 1950 - 2450 mm Ø 160 86 23 23 B 86 23 23 D
D 4: Ø 110 86 23 31 B 86 23 31 D
Ø 125 86 23 32 B 86 23 32 D
2450 - 2950 mm Ø 160 86 23 33 B 86 23 33 D
D 5: Ø 110 86 23 41 B 86 23 41 D
Ø 125 86 23 42 B 86 23 42 D
2950 - 3450 mm Ø 160 86 23 43 B 86 23 43 D
4 Two inlets in flow direction left + right 90°:
D 1: Ø 110 86 24 01 B 86 24 01 D
Ø 125 86 24 02 B 86 24 02 D
950 - 1450 mm Ø 160 86 24 03 B 86 24 03 D
D 2: Ø 110 86 24 11 B 86 24 11 D
Ø 125 86 24 12 B 86 24 12 D
1450 - 1950 mm Ø 160 86 24 13 B 86 24 13 D
D 3: Ø 110 86 24 21 B 86 24 21 D
Channel Ø 125 86 24 22 B 86 24 22 D
example 1950 - 2450 mm Ø 160 86 24 23 B 86 24 23 D
Ø 1000
D 4: Ø 110 86 24 31 B 86 24 31 D
Ø 125 86 24 32 B 86 24 32 D
2450 - 2950 mm Ø 160 86 24 33 B 86 24 33 D
D 5: Ø 110 86 24 41 B 86 24 41 D
Ø 125 86 24 42 B 86 24 42 D
2950 - 3450 mm Ø 160 86 24 43 B 86 24 43 D

* Ø = Outer Diameter

Catalogue 2.2 173


Accessories

Modular design KESSEL Komfort-inspection chambers Ø 1000


Standard inspection chambers with monolithic structure

System illustration of the installation depths

Cover plate

Upper section
Cover plate in cast iron
max. installation depth up to 5 m

Profiled lip seal


Cover plate in cast iron surface water-tight,
Transition piece
and concrete with gasket and screws
Installation depth D 4 not screwed Class A Art. # 860 132
also: Class A Art. # 860 130 Class B Art. # 860 133
Upper section and Class B Art. # 860 131 Class D Art. # 860 136
cover plate with
transition section 1070 Profiled gasket 1070

610 610
Connecting wedges

637

637
Extension section

Installation depth D 3 Upper section Upper section


with clamping ring with clamping ring
also:
Class A, B, not screwed Class A, B, D, screwed
Upper section and
cover plate with Art. # 860 120 Art. # 860 121
transition section 1200 Profiled gasket 1200

44
Connecting wedges
63,5
Extension section 10
171
68

Installation depth D 2
36

also:
Upper section and 166.5
Komfort-inspection chambers with modular structure

cover plate with


transition section 1070 Profiled gasket 1070 Set of connecting wedges Access steps
12 pieces with fastening bolts
Connecting wedges Art. # 860 111 Art. # 860 110

Extension section

Installation depth D 1

also: 1070
Upper section and
cover plate with
500

transition section 1200 Profiled gasket 1200

Connecting wedges 1200

Base part

Extension section
Art. # 860 101

174 Catalogue 2.2


Accessories

Modular design KESSEL Komfort-inspection chambers Ø 1000

Standard inspection chambers with monolithic structure


Cover plate in cast iron Clamping ring
with ventilation Cover plate in cast iron Lifting and for upper section
not screwed with ventilation locking mechanism Inspection chamber system
Class A Art. # 860 134 screwed, including screws for inspection chamber cover Ø 800/1000
Class B Art. # 860 135 Class D Art. # 860 137 Art. # 915 595 Art. # 860 129

120

24
645 645

590
290

290

613
1070 1200

Transition section 1070 Transition section 1200 Profiled lip seal Sludge trap made of polymer
Art. # 860 103 Art. # 860 102 Art. # 860 114 Art. # 860 115

For Ø 200 and Ø 250 drilling machine


with min. 1000 W to be used!
30
30

22


Hole saw
1094 1236 Gasket for pipe conduit for drilling the openings
Ø 110 Art. # 850 117 for the gasket for pipe conduit

Komfort-inspection chambers with modular structure


Ø 125 Art. # 850 118 Ø 50 - 160 Art. # 50 100
Ø 160 Art. # 850 119 Ø 50 - 110 Art. # 50 101
Profiled gasket 1070 Profiled gasket 1200 Ø 200 Art. # 182-875 Ø 200 Art. # 50 102
Art. # 860 112 Art. # 860 113 Ø 250 Art. # 182-879 Ø 250 Art. # 50 103

1200
765

Closed base
Art. # 860 008

Catalogue 2.2 175


Variable upper section:
Komfort-inspection chambers Ø 400 rotatable
with open channel passage inclinable
height adjustable
Illustration Article description
Standard inspection chambers with monolithic structure

Komfort-inspection chamber Ø 400 mm


in PE-HD polyethylene
with open channel passage in PP
Installation depth D from ...... mm to ...... mm,
water-tight, resistant to aggressive wastewater.
Upper section in synthetic material for continuous height and
level adjustment.
Optional cover plate/slotted cover
Class A made of polymer,
Class B/D in cast iron according to EN 124,
without/with sludge trap.
Open channel passage Ø ...., with/without lateral inlets
Ø ....., 45° in flow direction left+right, outlet Ø ....
for connection for PVC pipe according to DIN 19534
and PE-HD pipe according to DIN 19537, Art. # ......

Accessories
Page 178-179

224
Certification no. Z-42.1-224

Channel types: Delivery:


Inspection chambers in components (stacked) for on-site
assembly, incl. assembly system
Flow direction

Installation depths:
Ø 160 Ø 200 Ø 250 Ordering overview, upper sections,
D 1 700-1050 mm 745-1095 mm 785-1135 mm covers and gaskets see page 178 - 179
D 2 1050-1400 mm 1095-1445 mm 1135-1485 mm
D 3 1400-1750 mm 1445-1795 mm 1485-1835 mm Upper section Upper section
D 4 1750-2100 mm 1795-2145 mm 1835-2185 mm with cover plate with slotted cover
D 5 2100-2450 mm 2145-2495 mm 2185-2535 mm and sludge trap
Komfort-inspection chambers with modular structure

Installation depth D: Cover - Upper edge to outlet - Lower edge


D5

D4

D3

D2

D1

Flow direction

Installation depths of up to 5 m available


Assembled from a modular system, see page 178 - 179

176 Catalogue 2.2


Komfort-inspection chambers Ø 400
with open channel passage
Width / Art. # cover plate
Channel Installation depth D in mm Art. # with cover plate with slotted cover and sludge trap

Standard inspection chambers with monolithic structure


Channel passage
Inlet/Outlet Ø 160 Class A Class B Class D Class A Class B Class D
D1 700 to 1050 85 11 03 A 85 11 03 B 85 11 03 D 85 11 03 AS 85 11 03 BS 85 11 03 DS
D2 1050 to 1400 85 11 13 A 85 11 13 B 85 11 13 D 85 11 13 AS 85 11 13 BS 85 11 13 DS
D3 1400 to 1750 85 11 23 A 85 11 23 B 85 11 23 D 85 11 23 AS 85 11 23 BS 85 11 23 DS
D4 1750 to 2100 85 11 33 A 85 11 33 B 85 11 33 D 85 11 33 AS 85 11 33 BS 85 11 33 DS
D5 2100 to 2450 85 11 43 A 85 11 43 B 85 11 43 D 85 11 43 AS 85 11 43 BS 85 11 43 DS
Inlet/Outlet Ø 200 Class A Class B Class D Class A Class B Class D
D1 745 to 1095 85 11 04 A 85 11 04 B 85 11 04 D 85 11 04 AS 85 11 04 BS 85 11 04 DS
D2 1095 to 1445 85 11 14 A 85 11 14 B 85 11 14 D 85 11 14 AS 85 11 14 BS 85 11 14 DS
D3 1445 to 1795 85 11 24 A 85 11 24 B 85 11 24 D 85 11 24 AS 85 11 24 BS 85 11 24 DS
D4 1795 to 2145 85 11 34 A 85 11 34 B 85 11 34 D 85 11 34 AS 85 11 34 BS 85 11 34 DS
D5 2145 to 2495 85 11 44 A 85 11 44 B 85 11 44 D 85 11 44 AS 85 11 44 BS 85 11 44 DS
Inlet/Outlet Ø 250 Class A Class B Class D Class A Class B Class D
D1 785 to 1135 85 11 05 A 85 11 05 B 85 11 05 D 85 11 05 AS 85 11 05 BS 85 11 05 DS
D2 1135 to 1485 85 11 15 A 85 11 15 B 85 11 15 D 85 11 15 AS 85 11 15 BS 85 11 15 DS
D3 1485 to 1835 85 11 25 A 85 11 25 B 85 11 25 D 85 11 25 AS 85 11 25 BS 85 11 25 DS
D4 1835 to 2185 85 11 35 A 85 11 35 B 85 11 35 D 85 11 35 AS 85 11 35 BS 85 11 35 DS
D5 2185 to 2535 85 11 45 A 85 11 45 B 85 11 45 D 85 11 45 AS 85 11 45 BS 85 11 45 DS

Channel passage with two lateral inlets 45°


Inlets/Outlet Ø 160 Class A Class B Class D Class A Class B Class D
D1 700 to 1050 85 14 03 A 85 14 03 B 85 14 03 D 85 14 03 AS 85 14 03 BS 85 14 03 DS
D2 1050 to 1400 85 14 13 A 85 14 13 B 85 14 13 D 85 14 13 AS 85 14 13 BS 85 14 13 DS
D3 1400 to 1750 85 14 23 A 85 14 23 B 85 14 23 D 85 14 23 AS 85 14 23 BS 85 14 23 DS
D4 1750 to 2100 85 14 33 A 85 14 33 B 85 14 33 D 85 14 33 AS 85 14 33 BS 85 14 33 DS
D5 2100 to 2450 85 14 43 A 85 14 43 B 85 14 43 D 85 14 43 AS 85 14 43 BS 85 14 43 DS
Inlets Ø 160/Outlet Ø 200 Class A Class B Class D Class A Class B Class D
D1 700 to 1050 85 14 07 A 85 14 07 B 85 14 07 D 85 14 07 AS 85 14 07 BS 85 14 07 DS
D2 1050 to 1400 85 14 17 A 85 14 17 B 85 14 17 D 85 14 17 AS 85 14 17 BS 85 14 17 DS
D3 1400 to 1750 85 14 27 A 85 14 27 B 85 14 27 D 85 14 27 AS 85 14 27 BS 85 14 27 DS
D4 1750 to 2100 85 14 37 A 85 14 37 B 85 14 37 D 85 14 37 AS 85 14 37 BS 85 14 37 DS
D5 2100 to 2450 85 14 47 A 85 14 47 B 85 14 47 D 85 14 47 AS 85 14 47 BS 85 14 47 DS

Komfort-inspection chambers with modular structure


Inlets/Outlet Ø 200 Class A Class B Class D Class A Class B Class D
D1 745 to 1095 85 14 04 A 85 14 04 B 85 14 04 D 85 14 04 AS 85 14 04 BS 85 14 04 DS
D2 1095 to 1445 85 14 14 A 85 14 14 B 85 14 14 D 85 14 14 AS 85 14 14 BS 85 14 14 DS
D3 1445 to 1795 85 14 24 A 85 14 24 B 85 14 24 D 85 14 24 AS 85 14 24 BS 85 14 24 DS
D4 1795 to 2145 85 14 34 A 85 14 34 B 85 14 34 D 85 14 34 AS 85 14 34 BS 85 14 34 DS
D5 2145 to 2495 85 14 44 A 85 14 44 B 85 14 44 D 85 14 44 AS 85 14 44 BS 85 14 44 DS
Inlets Ø 200 /Outlet Ø 250 Class A Class B Class D Class A Class B Class D
D1 745 to 1095 85 14 08 A 85 14 08 B 85 14 08 D 85 14 08 AS 85 14 08 BS 85 14 08 DS
D2 1095 to 1445 85 14 18 A 85 14 18 B 85 14 18 D 85 14 18 AS 85 14 18 BS 85 14 18 DS
D3 1445 to 1795 85 14 28 A 85 14 28 B 85 14 28 D 85 14 28 AS 85 14 28 BS 85 14 28 DS
D4 1795 to 2145 85 14 38 A 85 14 38 B 85 14 38 D 85 14 38 AS 85 14 38 BS 85 14 38 DS
D5 2145 to 2495 85 14 48 A 85 14 48 B 85 14 48 D 85 14 48 AS 85 14 48 BS 85 14 48 DS

Catalogue 2.2 177


Accessories

Modular design KESSEL Komfort-inspection chambers Ø 400


Standard inspection chambers with monolithic structure

System illustration of the installation depths 46 52


20 30

362

395
Cover plate made of polymer
max. installation depth up to 5 m

Class A
Art. # 850 132
Installation depth D 5
Cover plate in cast iron Cover plate in cast iron
also: Profiled gasket 360 Class B Class D
Upper section and Art. # 850 131 Art. # 850 136
cover plate with Connecting wedges
transition section 360 450
400
Extension section

450
440
Installation depth D 4

also: Profiled gasket 450


Upper section and
cover plate with Connecting wedges 330 330
transition section 450 Upper section Upper section
with clamping ring with clamping ring
Extension section Class A, B Class D
Art. # 850 120 Art. # 850 121
Installation depth D 3

also: Profiled gasket 360


Upper section and
cover plate with Connecting wedges 63,5
360
transition section 360

Extension section

350
68
36

Installation depth D 2

also: 450
Profiled gasket 450
Komfort-inspection chambers with modular structure

Upper section and


cover plate with Connecting wedges
transition section 450 Set of connecting wedges
4 pieces Extension section
Extension section Art. # 850 111 Art. # 850 101
Installation depth D 1

also: Profiled gasket 360


Upper section and
cover plate with Connecting wedges
transition section 360
450
Extension section
308

Profiled gasket 450


Connecting wedges

Base part

Closed base
Art. # 850 008

178 Catalogue 2.2


Accessories

Modular design KESSEL Komfort-inspection chambers Ø 400

Standard inspection chambers with monolithic structure


395
362

15 20 25 20 25 30
45 46 50

Slotted cover made of polymer Slotted cover in cast iron Slotted cover in cast iron
Class A Class B Class D
Art. # 850 134 Art. # 850 135 Art. # 850 137

320
36
36

328 328

270
358 450 Clamping ring
for upper section
Inspection chamber system
Transition section 360 Transition section 450 Sludge trap made of polymer Ø 400
Art. # 850 103 Art. # 850 102 Art. # 850 115 Art. # 850 129

For Ø 200 and Ø 250 drilling machine


with min. 1000 W to be used!
22

368 458

Hole saw
for drilling the openings
for the gasket for pipe conduit

Komfort-inspection chambers with modular structure


Gasket for pipe conduit Ø 50 - 160 Art. # 50 100
Ø 110 Art. # 850 117 Ø 50 - 110 Art. # 50 101
Profiled gasket 360 Profiled gasket 450 Ø 125 Art. # 850 118 Ø 200 Art. # 50 102
Art. # 850 112 Art. # 850 113 Ø 160 Art. # 850 119 Ø 250 Art. # 50 103

L
L

450 450



Open channel passage


Inlet/Outlet Ø 160, L=726 mm, H=259 mm, Art. # 850 001 Open channel passage
Inlet Ø 160/Outlet Ø 200, L=746 mm, H=259 mm, Art. # 850 002 Inlet/Outlet Ø 160, L=726 mm, H=259 mm, Art. # 850 005
Inlet/Outlet Ø 200, L=756 mm, H=304 mm, Art. # 850 003 Inlet/Outlet Ø 200, L=756 mm, H=306 mm, Art. # 850 006
Inlet Ø 200/Outlet Ø 250, L=771 mm, H=304 mm, Art. # 850 004 Inlet/Outlet Ø 250, L=790 mm, H=344 mm, Art. # 850 007

Catalogue 2.2 179


180 Catalogue 2.2

S-ar putea să vă placă și