Sunteți pe pagina 1din 1

Instruction Sheet P/N 1029718A

ProBluet Melter Main Circuit Board Service Kit - P/N 1028322


Use this service kit to replace the main circuit board in ProBlue melters, WARNING: Risk of personal injury or equipment damage! Refer to Tools:
models P4 and P7. the safety information provided in the melter manual before servicing Phillips-head screw driver
the melter. Failure to comply with the safety information provided
can result in personal injury, including death.

WARNING: Risk of electrocution! The control switch does not


remove high-voltage power from the melter. Before opening the
electrical compartment door, ensure that the local power
disconnect switch is in the off position and locked. Failure to
properly disconnect power from the melter can result in personal
injury, including death.

1. Disconnect power to the melter at the local 5. Remove the Phillips-head screw and
power disconnect switch. washers that secure the main circuit board to
the chassis.

2. Switch the melter off.


Main Circuit Board
3. Remove or partially disengage the hose gun
modules from the main circuit board.

CAUTION: Before removing the new circuit


board from its anti-static bag, ground yourself by
touching the chassis of the melter or another
grounded structure. Failure to properly ground
yourself can cause electrostatic discharge
resulting in damage to the board.

6. Slide the main circuit board out and replace it


with the new board. Replace the Phillips-head
screw and washers.

4. Open the electrical enclosure door and


disconnect the voltage plug (J1/J2) and all cables
from the main circuit board (TB1, TB2, J6, J7, and
J8).

J7

J8
7. Connect the voltage plug and all cables
to the new circuit board and then close the
electrical enclosure door.

J6 J1
J2 8. Restore power to the melter and then
TB2 switch the melter on. Verify that the melter starts
normally.
TB1