PRESSURE CONTROLS

Date:18/07/2017
EI.V4-0217
■ Hydro-Electric Pressure Switch

Spring loaded sealed piston construction. Encapsulated design


for protection against dirt.
Plug-in connector conforming to DIN 43650 / ISO 4400 for
electrical connection.

■ Pressure Setting Ranges


Max. Operating Pressure Pressure Setting Range
Kgf/cm² Kgf/cm²
A : 40 5 to 40
B : 100 12 to 100
C : 200 20 to 200
D : 350 30 to 350

Graphic Symbol
■ Model Number Designation
P
NC
1
NO
2
C
3
F YS G -A -20
Series Type of Working Pressure Design
Special Seals *1
Number Mounting Kgf/cm² Number
*2
F:
Special Seals YS: G: A: 5~40
For Phosphate YIL Sub plate B: 12~100
Ester Type 20
Pressure Mounting C: 20~200
Fluids. Switch
(Omit if not D : 30~350
required)
*1
Design numbers subjected to change . But installation dimensions remains as shown.
*2
. Consult YUKEN for ‘F’ type models

■ Instructions
Pressure Adjustment
Loosen the locknut, then turn the pressure adjustment screw slowly clockwise for higher pressures or
anti-clockwise for lower pressures. Retighten the locknut after getting required setting.

■ Mounting Blots
Model Number Socket Head Cap Screw Qty. Bolt Kit Ordering Code
YSG -※-20 M5 x 50Lg. 2 BK-YSG-01-20

■ Spare Parts List


List of Seals
SL.No. Part Name Name of Part Qty.
1 SO-NB-P14 O-Ring 1
2 SO-NB-P9 O-Ring 1
3 OD006005200171A Step Seal 1
Note : When ordering the seals, please specify the seal kit number KS-YSG-20.

DIN Connector
When ordering the DIN Connector as a spare part, please specify HD-309/S.

Hydro-Electric Pressure Switch


1/3
PRESSURE CONTROLS
■ Connection Diagram ■ Pressure and Micro-Switch Contacts
Micro Switch Contact
Pressure Solenoid
Point
C 3

1 4 2
Under the Setting
ENERGIZED
Pressure
CO NO NC NC NO
1 2

C 3

Above the Setting


ENERGIZED
Pressure
NC NO
1 2

Hydro-Electric Pressure

Switch
Switching Pressure Differential
YSG-A-20 YSG-B-20
Kgf/cm²
8
Kgf/cm²
7
Switching pres.

6 6
Switching pres.

differential

5 5
differential

4 4
3 3
2 2
1 1
0 10 20 30 40 Kgf/cm² 0 10 20 30 40 50 60 70 80 90 100 Kgf/cm²
Set switching pressure Set switching pressure

YSG-C-20 YSG-C-20
Kgf/cm²
Kgf/cm² 25

16 20
14
Switching pres.

Switching pres.

12 15
differential

differential

10
8 10
6
4 5
2
0 20 40 60 80 100 120 140 160 180 200 Kgf/cm² 0 50 100 150 200 250 300 350 Kgf/cm²
Set switching pressure Set switching pressure

Hydro-Electric Pressure Switch


2/3
PRESSURE CONTROLS

YSG -※-20 DIMENSIONS IN


MILLIMETRES

Outside-8-10mm
Conductor Area- Not Exceding 1.5mm

45.5
(94.4 max)

M8 Locknut (A/F-13mm)

5
Use12-13 spanner
Pressure Adj. screw
(Use 6mm allen key)

41
Mounting Interface

5
42.5 max

15
30

33
M5x0.8 Thd.

40
30
15

11 Deep
6 Dia. x Thru.
7
136(Max)
7.5
15

■ Sub-Plate
Model Number Sub-Plate Piping Size Mass Kg.
YSG -※-20 YSGM-01-10 1/4” BSP.F 0.24

Sub-plate: YSGM-01-10 DIMENSIONS IN


5 Dia. x Thru. MILLIMETRES

M5 Thd. x 11 Deep
25
1
4 BSP.F
21 Dia. Spotface
30
40

4
15
5

11.5 16.5
33

Note: Sub-Plate to be ordered separately Ordering code for sub plate is YSGM-01-10.

Hydro-Electric Pressure Switch


3/3

S-ar putea să vă placă și