SIPROTEC 5

Configuration
Aug 28, 2020 7:18 AM

Device: 7KE85 Fault Recorder


40 voltage / current transf.

Product code
Short: P1N160144
Long: 7KE85-DAAA-AA0-0AAAA0-AA8111-51113A-ABA000-000AC1-CB1BA1-CH1CP1-CB1CB1-BC1EA0

Firmware: Current version


Housing width: 1 x 19'' + 1/3 x 19''
Housing type: Flush mounting
Binary inputs: 81
Binary outputs: 37 Relays (6 Standard, 31 Fast, 0 High-Speed, 0 Power)
Current transformers: 20 for protection
Voltage transformers: 20 standard
Measuring-transducer inputs: 0 (20 mA or 10 V, fast)
0 (20 mA, standard)
CPU: CP300.
Modules in 19" row 1: IO202 , PS201 , IO208 , IO214 , IO202 , IO202
Modules in 19" row 2: PS203 , IO230
LEDs/Push-buttons: 80 LEDs
Operation Panel: Integrated
Key switch: Without
Display type: No display
SIPROTEC 5
Configuration
Aug 28, 2020 7:18 AM

Front Design: Standard


Power Supply: DC 60 V-250 V, AC 100 V-230 V
Redundant Power Supply: No

Communication/Plug-in modules:
Communications encryption: Normal
Integrated Ethernet port J: DIGSI 5 and IEC 61850/Goose
Plug-in module position E: Port is available but not assembled
Plug-in module position F: ETH-BA-2EL: 2x electric Ethernet 100 Mbit/s, RJ45 Communication Protocols:
applicable for DIGSI 5, IEC 61850-8-1 MMS and GOOSE, IEC 60870-5-104,
DNP3 TCP, Modbus TCP, Synchrophasor (IEEE C37.118 - IP), Profinet IO, SUP,
DHCP, SNTP, SNMP, etc. Redundancy protocols: Line Mode, RSTP, HSR, PRP

Functions:
Function points class: Base

Note on function-points class


The function-points class results from the sum of the function points of the selected functions. You can apply these
functions as selected. The device allows also each other selection of functions as long as the sum of the required
function points is within the selected function-points class. With the maximum function-points class of 1400 it is
possible to activate all the functions in the device. The function-points exceeding 1400 are free of charge. In the
engineering phase DIGSI 5 checks that the selected configuration is suitable (capable of running in the device) before
loading it to the device.

Miscellaneous:
Warranty: 5 years
Firmware: Current version
SIPROTEC 5
Configuration
Aug 28, 2020 7:18 AM

Functional scope 7KE85 Fault Recorder:


Always Add selected Result
ANSI Function Abbr. included Qty. x Value = Points Qty.
Hardware quantity structure expandable I/O

Process Bus Client Protocol (Note: This PB client x 100 =


function requires at least one dedicated
ETH-BD-2FO plug-in module, with
V8.0)
IEC61850-9-2 Merging Unit stream MU x 200 =
(Note: This function requires a
dedicated ETH-BD-2FO per stream,
with V8.0)
PMU Synchrophasor measurement PMU x 40 =
Measured values, standard

Measured values, extended: Min, Max,


Avg
Circuit-breaker wear monitoring Ix, I²t, 2P x 10 =
CFC (Standard, control)

CFC arithmetic x 40 =
Circuit-breaker 4x x 3 = 4x
Fault recording of analog and binary
signals
Monitoring and supervision

FSR Fast-scan recorder FSR

SSR Slow-scan recorder SSR 1x x 40 = 1x


CR Continuous recorder CR 1x x 25 = 1x
TR Trend recorder TR 1x x 25 = 1x
PQR Power Quality recordings PQR x 150 =
(functionalities)
Splitter for harmonics and x 10 =
interharmonics (from V8.01)
Sequence of events recorder SOE

ExTrFct Extended trigger functions ExTrFct

Frequency-tracking groups (from V7.8)

Temperature acquisition via


communication protocol
SIPROTEC 5
Configuration
Aug 28, 2020 7:18 AM

Functional scope 7KE85 Fault Recorder:


Always Add selected Result
ANSI Function Abbr. included Qty. x Value = Points Qty.
Cyber Security: Role-Based Access x 25 =
Control (from V7.8)
Sum: 0