Sunteți pe pagina 1din 2

CATALOGO 2002 INGLESE 22-04-2002 17:12 Pagina 98

POWER SUPPLIES - AMPLIFIERS ALNC - ALN2


SPECIFICATIONS
These instruments are made up of a transformer an
amplifier and a transistor, a rectifying circuit and
one or two output relays with changeover con-
tacts, respectively in the ALNC and ALN2 types.
They are used to supply with a stabilized and level
12 Vdc voltage inductive and capacitive sensors
and photocells. The electronic unit of the two
models is assembled in a plastic container with 11
Pin socket.
The ALNC model is very versatile as it permits the
use of a sensor with NPN, PNP or NAMUR logic.
The ALN2 type allows for the use of two NAMUR
sensor.

IDENTIFICATION REFERENCES

AL N C

TECHNICAL CHARACTERISTICS

Power supply 24VDC/AC AL N 2


Power supply ± 15% 110/220VAC 50-60Hz
Output current 12 VDC ALNC: Power supply - amplifier for n. 1 NAMUR
Absorption 3VA sensor or n. 1 amplified sensor.
Max output current 50 mA Specify the power supply: 24 Vac/dc or
Temperature range -20 ÷ + 60°C 110/220 Vac.
IP rating IP 40 ALN2: Power supply - amplifier for n. 2 NAMUR
LED incorporated sensors.
Type ALNC relay ouyput 1 changeover 5A 220VAC Specify the power supply: 24 Vac/dc or
Type ALN2 2 relays ouyput 1 changeover 5A 220VAC 110 Vac or 220 Vac.

WIRING DIAGRAMS ALNC DIMENSIONS (mm)


BROWN BROWN
BLACK
BLUE BLUE

N
P + P
N N
P 6
7 5
10
8 4

9 3
220
® ®
24 110 10 2

0 11 1
0 RELAY 1

PIN 5 = NPN PIN 8 = PNP


RELAY 2
76

WIRING DIAGRAMS ALN2


BROWN BROWN ALNC ALN2
POWER SUPPLY POWER SUPPLY AMPLIFIER
FOR PROXIMITY SENSORS 2 NAMUR SENSORS

1 BLUE BLUE
2
38 38 13 70

11 1
10 2
ALNC ALN2
9 3
RELAY 2
8 4
RELAY 1
7 5
6

24V-110V-220V
POWER SUPPLY

For a correct fixing of the AECO units it is recommended to use socket B8 an B11 with fixing spring MF. (page 102)
®
98
CATALOGO 2002 INGLESE 22-04-2002 17:12 Pagina 99

PROGRAMMABLE POWER SUPPLY - AMPLIFIER ALTP


SPECIFICATIONS
These units are very versatile as they can be used with all NAMUR, NPN
and PNP sensors, functioning with relay ON or OFF load with a timing
function in both states.
Furthermore they have a programmable time scale from 0,03 seconds to
12 minutes.

PROGRAMMABLE FUNCTIONS

1) DELAY
The range of delay is from 0,03 seconds and 512 seconds (see table A) dis-
tribuited on 9 selectable scales via a dip switch mounted on the front. The
selected scale can be adjusted by means of a potentiometer on a graduated
scale from 0,05 to 1. It is possible by summing the two scales to obtain full
scale values which are different to the standard. This is obtained by placing the
switch with the chosen values in the ON position (e.g. pos. 1 an 2 switch ON
corresponds to a full scale of 640 seconds).
2) TYPE OF FUNCTION AND SENSOR
For this function it is necessary to simultaneously programme the dip switch-
es of position 10 - 11 - 12. Following table B it is possible to programme the
instrument with an on delay (TE) or off delay (TD) depending on the sensor
NAMUR, NPN or PNP.
Furthermore it is possible to programme these functions with relay on load
(ON) and off load (OFF).

TABLE A TECHNICAL CHARACTERISTICS

SWITCH RANGE OF DELAY Power supply 24VDC/AC


POSITION (in seconds)
Power supply ± 15% 110/220VAC 50-60Hz
1 25,6 - 512
2 6,4 - 128 Output current 12 VDC
3 1,6 - 32 Absorption 3VA
4 0,8 - 16 Max output current 50mA
5 0,4 - 8 Output relay 1 changeover 5A 220VAC
6 0,2 - 4 Temperature range -20 ÷ + 60°C
7 0,1 - 2
IP rating IP 40
8 0,05 - 1
Range of delay 0.03 sec ÷ 12 min
9 0,03 - 0,5

TABLE B DIMENSIONS (mm)

RELAY FUNCTION DIP 10 DIP 11 DIP 12


PNP TE OFF OFF ON
PNP TD ON OFF OFF
NPN TE ON ON ON
OFF NPN TD OFF ON OFF
NAMUR TE ON OFF ON
NAMUR TD OFF OFF OFF 10

PNP TE OFF OFF OFF


PNP TD ON OFF ON
®

ON NPN TE OFF ON ON
1
NPN TD ON ON OFF 2
3
4

NAMUR TE OFF OFF ON 5


6
7

NAMUR TD ON OFF OFF 8


9
10
SEC.
76

11
12
ON OFF

WIRING DIAGRAM
POWER SUPPLIES

ALTP
DELAYED PROGRAMMABLE
POWER SUPPLY AMPLIFIER

1 2 3 7 4 5 6 8 9 10 11
÷12V
-OV

INPUT

0
38 13 70

RELAY
24
5A-220V

110

220

NAMUR AMPLIFIED
SENSOR SENSOR

For a correct fixing of the AECO units it is recommended to use socket B8 an B11 with fixing spring MF. (page 102)

99

S-ar putea să vă placă și