Sunteți pe pagina 1din 4

Air Handling Systems

Spiracoustic Plus™
Round Duct Liner System

Specification Compliance
Spiracoustic Plus
Spiracoustic Plus System*... For All Your Round Duct Liner Needs
Specification or Standard Round Duct Liner Description
ASTM G 21 and G 22 X The Spiracoustic Plus System from Johns Manville is a comprehensive
group of duct lining products specifically engineered to provide very high
State of Washington Building Services
acoustical and thermal performance in round air ducts of virtually any size.
Department requirements for emissions
of Total Volatile Organic Compounds Based on high-density fiber glass board technology, Spiracoustic Plus has
(TVOC) and formaldehyde (CHOH) in factory-made, evenly-spaced kerfs to allow the material to conform to the
accordance with ASTM D 5116 X inside diameter of round air ducts. The airstream surface and transverse
edges are coated with Johns Manville’s proprietary black Permacote®
NFPA Standards 90A and 90B X acrylic polymer. The coating is treated with an immobilized protective
ASHRAE 62 X agent, specifically registered with the EPA for HVAC duct applications,
UL 181/ASTM C 1071 Air Erosion Test X to protect the coating against potential microbial growth.
ULC S102-M88; FHC 25/50 X Spiracoustic Plus eliminates the need for costly double-wall insulation practice in round air duct,
ASTM E 84; FHC 25/50 X and provides consistent thermal and acoustical performance throughout.
The bottom line: comfort with peace of mind.
ISO 9000 Certification Uncomplicated Installation
Johns Manville mechanical insulation products are designed, manufactured and tested in our own Spiracoustic Plus is easy to install, and can be fabricated in the shop or field to meet individual job
facilities, which are certified and registered to stringent ISO 9000 (ANSI/ASQC 90) series quality requirements. Simply cut each liner section to the proper circumference “stretch-out”, form it into
standards. This certification, along with regular, independent third-party auditing for compliance, a round configuration, and close the seam with tape. The liner is now ready for either “snap-in” or
is your assurance that Johns Manville products deliver consistent high quality. “slip-fit” installation, depending upon duct diameter. Spiracoustic Plus is self-supporting in most
round applications, with adhesives and pins typically required only in fitting applications and very
Availability large diameter or unusual duct configurations.
Please contact your Regional Sales Office for price and availability of Spiracoustic Plus System Johns Manville provides the finishing touches to Spiracoustic Plus round duct insulation with a com-
products. plete line of SuperSeal® coating products. These unique acrylic coatings are air-drying versions of the
factory-applied airstream coating designed for fabrication and repair use. SuperSeal products help
retain all the performance characteristics engineered into Spiracoustic Plus.
For additional information on fabrication and installation of Spiracoustic Plus, refer to the “Spiracoustic
Plus Installation Guide”, AHS-306.

VSD for Very SD for Small LD for Large Diameters


Small Diameter Diameters “Snap-in” Installation
Metal Ducts “Snap-in”
“Slip-fit” Installation
Installation

The physical and chemical properties of the Spiracoustic Plus™


Round Duct Liner System represent typical, average values
North American Sales Offices, obtained in accordance with accepted test methods and are
Insulation Systems subject to normal manufacturing variations. They are supplied
as a technical service and are subject to change without notice. 32" & up
Eastern Region Numerical flame spread and smoke developed ratings are not
P.O. Box 158 intended to reflect hazards presented by these or any other
Defiance, OH 43512 18"-58"
materials under actual fire conditions. Check with the Regional
(800) 334-2399 8"-22"
Sales Office nearest you to assure current information. All
Fax: (419) 784-7866
Johns Manville products are sold subject to Johns Manville’s
Western Region & Canada standard Terms and Conditions including Limited Warranty
717 17th St. P.O. Box 5108 and Limitation of Remedy. For a copy of the Johns Manville
Denver, CO 80202 Denver, CO 80217 standard Terms and Conditions, Limited Warranty and Limitation Minimum to maximum metal duct inside diameter ranges vary by insulation thickness. Please refer to the tables in
(800) 654-3103 (800) 368-4431 of Remedy, and information on other Johns Manville thermal AHS-361, AHS-362 and AHS-363 for specific applications for 1", 11/2" and 2" thick insulations, respectively.
specJM.com Fax: (303) 978-4661 insulations and systems, call (800) 654-3103.
* Covered by one or more of the following U.S. patents: 5,379,806 • 5,487,412 • 5,697,282 • 5,762,109 • 5,855,154 • 5,953,818
AHS-360 10-08 (Replaces 2-07) Printed on recycled paper. Copyright © 2008 Johns Manville
Other U.S. and foreign patents pending.
Printed in USA
System Advantages Spiracoustic Plus Delivers Performance
Double-Wall Performance with Single-Wall Simplicity. Did you ever stop to think about the thermal With Spiracoustic Plus, all of these questions are
Spiracoustic Plus allows single-wall ducts to equal or exceed the and acoustical performance of a double-wall answered in one easy sentence: The acoustical
acoustical and thermal performance of double-wall insulated insulated round air duct? What kind of and thermal performance of the air ducts are
round ducts. The self-supporting insulation eliminates the need to insulation is really going into that system? assured by the high density and controlled
connect both an internal core and external duct shell, and can be Is the density, fiber diameter, and thermal thickness of the material. With Spiracoustic Plus,
easily cut in the field if changes are required. (k-value) performance of the insulation material you can be sure you’ll get the performance you
Superior Temperature Control. The high density and specified? Is the insulation actually installed asked for.
manufactured thickness of Spiracoustic Plus means the thermal at the design thickness?
performance needed is always there. Ever wonder what the
performance of the low density insulation typically used in Additional Information
double-wall ducts really is? Spiracoustic Plus helps eliminate For additional information on Johns Manville's key Spiracoustic Plus System Products, request the
concerns about condensation, and maximizes comfort. following product literature by the form numbers below by calling (800) 654-3103, or visit us
Quieter Operation. With a dense insulation core and high online at specJM.com.
surface area, Spiracoustic Plus gives dramatic acoustical results. Literature
In well-designed systems, it virtually eliminates air rush noises, fan Product Information Form No.
noise, and crosstalk. No wonder it’s used in sports arenas and performance halls across the country! • Spiracoustic Plus™ Pocket Folder AHS-300
Airstream Surface Protected Against Microbial Growth. The airstream surface and trans- • Spiracoustic Plus™ System Brochure AHS-360
verse edges are coated with Johns Manville’s proprietary black Permacote acrylic polymer. The • Spiracoustic Plus™ 1” Product Information AHS-361
coating is formulated with an immobilized protective agent, specifically registered with the EPA for • Spiracoustic Plus™ 11⁄2” Product Information AHS-362
HVAC duct applications, to protect the coating from potential growth of fungus and bacteria. • Spiracoustic Plus™ 2” Product Information AHS-363

Tough Airstream Surface. The black acrylic polymer surface of Spiracoustic Plus offers minimal • Spiracoustic Plus VSD for Very Small Diameter AHS-347
resistance to airflow, but stands up to fabrication and installation handling. Use of available • Spiracoustic Plus™ System Guide Specifications AHS-320
SuperSeal coating products allows the system to retain all engineered performance characteristics • Spiracoustic Plus™ Installation Guide AHS-306
when fabrication cuts or repairs are needed.
• SuperSeal® Coating Products AHS-202

• Spiracoustic Plus Air Friction Chart AHS-182
Physical Properties Project Reports
I-P Units SI Units For information on specific Spiracoustic Plus installations, request
Thickness 1", 11⁄ 2", 2" 25 mm, 38 mm, 51 mm the following project reports by the form number below:
Nominal Density 4.0 pcf 64 kgs/m3 • Bank One Ballpark AHS-304
Air Velocity (max.) 6000 fpm 30.5 m/sec.
• Heart of Texas Coliseum AHS-309
Service Temperature (max.) 250°F 121°C
• Pepsi Center (Denver) AHS-310
• Busch Stadium AHS-389
Product Samples
Available Sizes For samples of Spiracoustic Plus System products, request the following
Spiracoustic Plus comes in cartons and on pallets in by the sample numbers below:
4' (1.22 m) x 10' (3.05 m) boards and is available in
• Spiracoustic Plus™ System L-10314
1" (25 mm), 11/2" (38 mm) and 2" (51 mm) thicknesses with butt edges to fit very small diameter
• Spiracoustic Plus™ VSD for Very Small Diameters S-0191
(VSD), small diameter (SD) and large diameter (LD) metal ducts. Boards are cut to the proper
circumference in the shop or field prior to installation. • SuperSeal® Duct Butter (16 oz. aerosol can) L-10273
• SuperSeal® HV™ (10.5 oz. tube) L-10272-S
• SuperSeal® Edge Treatment (16 oz. jar) L-10062-S
System Advantages Spiracoustic Plus Delivers Performance
Double-Wall Performance with Single-Wall Simplicity. Did you ever stop to think about the thermal With Spiracoustic Plus, all of these questions are
Spiracoustic Plus allows single-wall ducts to equal or exceed the and acoustical performance of a double-wall answered in one easy sentence: The acoustical
acoustical and thermal performance of double-wall insulated insulated round air duct? What kind of and thermal performance of the air ducts are
round ducts. The self-supporting insulation eliminates the need to insulation is really going into that system? assured by the high density and controlled
connect both an internal core and external duct shell, and can be Is the density, fiber diameter, and thermal thickness of the material. With Spiracoustic Plus,
easily cut in the field if changes are required. (k-value) performance of the insulation material you can be sure you’ll get the performance you
Superior Temperature Control. The high density and specified? Is the insulation actually installed asked for.
manufactured thickness of Spiracoustic Plus means the thermal at the design thickness?
performance needed is always there. Ever wonder what the
performance of the low density insulation typically used in Additional Information
double-wall ducts really is? Spiracoustic Plus helps eliminate For additional information on Johns Manville's key Spiracoustic Plus System Products, request the
concerns about condensation, and maximizes comfort. following product literature by the form numbers below by calling (800) 654-3103, or visit us
Quieter Operation. With a dense insulation core and high online at specJM.com.
surface area, Spiracoustic Plus gives dramatic acoustical results. Literature
In well-designed systems, it virtually eliminates air rush noises, fan Product Information Form No.
noise, and crosstalk. No wonder it’s used in sports arenas and performance halls across the country! • Spiracoustic Plus™ Pocket Folder AHS-300
Airstream Surface Protected Against Microbial Growth. The airstream surface and trans- • Spiracoustic Plus™ System Brochure AHS-360
verse edges are coated with Johns Manville’s proprietary black Permacote acrylic polymer. The • Spiracoustic Plus™ 1” Product Information AHS-361
coating is formulated with an immobilized protective agent, specifically registered with the EPA for • Spiracoustic Plus™ 11⁄2” Product Information AHS-362
HVAC duct applications, to protect the coating from potential growth of fungus and bacteria. • Spiracoustic Plus™ 2” Product Information AHS-363

Tough Airstream Surface. The black acrylic polymer surface of Spiracoustic Plus offers minimal • Spiracoustic Plus VSD for Very Small Diameter AHS-347
resistance to airflow, but stands up to fabrication and installation handling. Use of available • Spiracoustic Plus™ System Guide Specifications AHS-320
SuperSeal coating products allows the system to retain all engineered performance characteristics • Spiracoustic Plus™ Installation Guide AHS-306
when fabrication cuts or repairs are needed.
• SuperSeal® Coating Products AHS-202

• Spiracoustic Plus Air Friction Chart AHS-182
Physical Properties Project Reports
I-P Units SI Units For information on specific Spiracoustic Plus installations, request
Thickness 1", 11⁄ 2", 2" 25 mm, 38 mm, 51 mm the following project reports by the form number below:
Nominal Density 4.0 pcf 64 kgs/m3 • Bank One Ballpark AHS-304
Air Velocity (max.) 6000 fpm 30.5 m/sec.
• Heart of Texas Coliseum AHS-309
Service Temperature (max.) 250°F 121°C
• Pepsi Center (Denver) AHS-310
• Busch Stadium AHS-389
Product Samples
Available Sizes For samples of Spiracoustic Plus System products, request the following
Spiracoustic Plus comes in cartons and on pallets in by the sample numbers below:
4' (1.22 m) x 10' (3.05 m) boards and is available in
• Spiracoustic Plus™ System L-10314
1" (25 mm), 11/2" (38 mm) and 2" (51 mm) thicknesses with butt edges to fit very small diameter
• Spiracoustic Plus™ VSD for Very Small Diameters S-0191
(VSD), small diameter (SD) and large diameter (LD) metal ducts. Boards are cut to the proper
circumference in the shop or field prior to installation. • SuperSeal® Duct Butter (16 oz. aerosol can) L-10273
• SuperSeal® HV™ (10.5 oz. tube) L-10272-S
• SuperSeal® Edge Treatment (16 oz. jar) L-10062-S
Air Handling Systems

Spiracoustic Plus™
Round Duct Liner System

Specification Compliance
Spiracoustic Plus
Spiracoustic Plus System*... For All Your Round Duct Liner Needs
Specification or Standard Round Duct Liner Description
ASTM G 21 and G 22 X The Spiracoustic Plus System from Johns Manville is a comprehensive
group of duct lining products specifically engineered to provide very high
State of Washington Building Services
acoustical and thermal performance in round air ducts of virtually any size.
Department requirements for emissions
of Total Volatile Organic Compounds Based on high-density fiber glass board technology, Spiracoustic Plus has
(TVOC) and formaldehyde (CHOH) in factory-made, evenly-spaced kerfs to allow the material to conform to the
accordance with ASTM D 5116 X inside diameter of round air ducts. The airstream surface and transverse
edges are coated with Johns Manville’s proprietary black Permacote®
NFPA Standards 90A and 90B X acrylic polymer. The coating is treated with an immobilized protective
ASHRAE 62 X agent, specifically registered with the EPA for HVAC duct applications,
UL 181/ASTM C 1071 Air Erosion Test X to protect the coating against potential microbial growth.
ULC S102-M88; FHC 25/50 X Spiracoustic Plus eliminates the need for costly double-wall insulation practice in round air duct,
ASTM E 84; FHC 25/50 X and provides consistent thermal and acoustical performance throughout.
The bottom line: comfort with peace of mind.
ISO 9000 Certification Uncomplicated Installation
Johns Manville mechanical insulation products are designed, manufactured and tested in our own Spiracoustic Plus is easy to install, and can be fabricated in the shop or field to meet individual job
facilities, which are certified and registered to stringent ISO 9000 (ANSI/ASQC 90) series quality requirements. Simply cut each liner section to the proper circumference “stretch-out”, form it into
standards. This certification, along with regular, independent third-party auditing for compliance, a round configuration, and close the seam with tape. The liner is now ready for either “snap-in” or
is your assurance that Johns Manville products deliver consistent high quality. “slip-fit” installation, depending upon duct diameter. Spiracoustic Plus is self-supporting in most
round applications, with adhesives and pins typically required only in fitting applications and very
Availability large diameter or unusual duct configurations.
Please contact your Regional Sales Office for price and availability of Spiracoustic Plus System Johns Manville provides the finishing touches to Spiracoustic Plus round duct insulation with a com-
products. plete line of SuperSeal® coating products. These unique acrylic coatings are air-drying versions of the
factory-applied airstream coating designed for fabrication and repair use. SuperSeal products help
retain all the performance characteristics engineered into Spiracoustic Plus.
For additional information on fabrication and installation of Spiracoustic Plus, refer to the “Spiracoustic
Plus Installation Guide”, AHS-306.

VSD for Very SD for Small LD for Large Diameters


Small Diameter Diameters “Snap-in” Installation
Metal Ducts “Snap-in”
“Slip-fit” Installation
Installation

The physical and chemical properties of the Spiracoustic Plus™


Round Duct Liner System represent typical, average values
North American Sales Offices, obtained in accordance with accepted test methods and are
Insulation Systems subject to normal manufacturing variations. They are supplied
as a technical service and are subject to change without notice. 32" & up
Eastern Region Numerical flame spread and smoke developed ratings are not
P.O. Box 158 intended to reflect hazards presented by these or any other
Defiance, OH 43512 18"-58"
materials under actual fire conditions. Check with the Regional
(800) 334-2399 8"-22"
Sales Office nearest you to assure current information. All
Fax: (419) 784-7866
Johns Manville products are sold subject to Johns Manville’s
Western Region & Canada standard Terms and Conditions including Limited Warranty
717 17th St. P.O. Box 5108 and Limitation of Remedy. For a copy of the Johns Manville
Denver, CO 80202 Denver, CO 80217 standard Terms and Conditions, Limited Warranty and Limitation Minimum to maximum metal duct inside diameter ranges vary by insulation thickness. Please refer to the tables in
(800) 654-3103 (800) 368-4431 of Remedy, and information on other Johns Manville thermal AHS-361, AHS-362 and AHS-363 for specific applications for 1", 11/2" and 2" thick insulations, respectively.
specJM.com Fax: (303) 978-4661 insulations and systems, call (800) 654-3103.
* Covered by one or more of the following U.S. patents: 5,379,806 • 5,487,412 • 5,697,282 • 5,762,109 • 5,855,154 • 5,953,818
AHS-360 10-08 (Replaces 2-07) Printed on recycled paper. Copyright © 2008 Johns Manville
Other U.S. and foreign patents pending.
Printed in USA

S-ar putea să vă placă și