x CSA, FM, ATEX & PED (Optional) x 24 VDC, 120 VAC and 230 VAC
x RTD Temperature Measurement x Density Correction Available
x Configurable Current Loop & Alarm x New Family of Electronics Provides
Outputs Data Logging & Touch Screen
x True Net Oil and Net Water (With Capabilities Including Graphics
Flow Input) x Enhanced Electronics Can Replace
x Modbus RTU, HART Available Flow Computers In Fiscal Systems
This family of Water Cut Analyzers Phase Dynamics’ Full and Low All functions of the analyzers can
was developed specifically for use Range Analyzers offer the most be accessed through the front panel
in the oil industry. The Low Range accurate measurement possible. by four push button switches. The
Analyzer is typically used for The Low Range Analyzer has been LCD display indicates the
custody transfer or pipelines. The used on custody transfer pipeline measurement value as well as
Full Range analyzer is used for installations by all major oil temperature, net oil, net water, and
emulsion control in tanks, for companies. Phase Dynamics utilizes phase of the emulsion (full range
control of high water cut situations, the unique, patented, “Oscillator only). Full digital Modbus RTU
and for interface control. Flexibility Load Pull” microwave technology access to the information is
for the user is provided for through which provides for this outstanding standard. Electronics are available
various configurations including an capability. No other technology can i n N E M A 4 or explosion proof
insertion unit. compete with its benefits. enclosures
* All percentages are expressed as absolute water content percentages within a 2 Sigma deviation (95% Confidence).
Inputs: Outputs:
Frequency: Voltage or Magnetic Pickup Pulse (3mV to 15V Analog: Five (5) 4-20mA, 16 bit D-to-A Conversion
max.) with Field Selectable Definition Digital: Four RS-485 Modbus RTU, HART
Analog: 0-20 or 4-20 mA with Field Selectable Definition Inputs:
Frequency: Voltage or Magnetic Pickup Pulse (3mV to 15V
max.) with Field Selectable Definition
Analog: Five (5) 4-20mA 16 bit A-to-D Conversion Field
Selectable Definition
Insertion Analyzer
Group Line Testing
Pipelines
Well Testing
Emulsion Interface Control
Flow-Through
Group Line Testing
Pipelines
Well Testing
Emulsion Interface Control
Flow-Through
Group Line Testing
Pipelines
Well Testing
Emulsion Interface Control
© Phase Dynamics, Inc.
Analyzer Family 0306 Page 5
The Water Measurement Experts
NEMA4X is Only A
10.5
CSA Approved
C D
D
16.3
MENU SELECT VALUE ENTER
PHASEDYNAMICS
B
18
RECOMMENDED MINIMUM 0.75-14 NPT
CLEARANCE FOR ACCESS REDUCING BUSHING
.6 13.4
Figure 2
6.7
17.4
VALUE
SELECT
PHASE DYNAMICS
MENU ENTER
A B