Performance and reliability. Just because humidity products are offered on all products except HCH Series, Honeywell S&C
typically standardized and platform-based, they can still deliver humidity sensors offer interchangeability of ±3 % accuracy for
superior performance right out of the box. At Honeywell Sensing potential applications as diverse as heating, ventilation and air
and Control (S&C), each sensor is designed to provide enhanced conditioning equipment (HVAC), refrigeration, office automation,
sensitivity, response time, stability and reliability. Configured and medical equipment.
with integrated circuitry to provide on-chip signal conditioning

FEATURES
hUMIDITY sENSORS Benefits: Slotted can design allows for component. Factory calibration data
HIH-4000 Series. quick response while still maintaining designed to provide individually matched
Features: Voltage output • Near linear robustness of enclosed components. downstream electronics and accuracy,
voltage output vs % RH • Laser-trimmed Factory calibration data designed to standard. Laser trimmed for stable, low
• Accurate, fast response • Molded provide individually matched downstream drift performance in potential applications
thermoset plastic housing • Chemically electronics and accuracy, optional. such as HVAC, refrigeration, medical,
resistant • Accuracy of ±3.5 % RH Laser trimmed for stable, low drift office automation, telecommunications
• Voltage supply of 4 Vdc to 5.8 Vdc performance in potential applications and meterology equipment.
such as refrigeration, drying, meterology
Benefits: Instrumentation-quality RH
equipment, battery-powered systems, and HCH-1000 Series.
sensing performance in a competitively
OEM (Original Equipment Manufacturer) Features: Capacitance output • Polyimide
priced, solderable SIP. Multilayer
assemblies. sensing material • Semiconductor
construction designed to provide excellent
fabrication technology • Glass wafer
resistance to wetting, dust, dirt, oils and
HIH-4602 A & C Series. substrate • Low hysteresis, long-term
common environmental chemicals. Laser
Features: Humidity and temperature stability • Enhanced and accurate
trimmed for stable, low drift performance
sensing in one package • Near linear response time
(optional). Factory calibration data
voltage output vs %RH • Laser-trimmed
provides individually matched downstream Benefits: Polyimide sensing material
• Accurate, fast response • Designed to
electronics and accuracy. designed to reduce temperature
be chemically resistant • Built-in static
dependence and enhances resistance
protection • Accuracy of ±3.5 % RH
HIH-4602-L Series. against contamination. Top grid electrode/
• Voltage supply of 4 Vdc to 5.8 Vdc
Features: Voltage output • Near linear polyimide layer, bottom electrode structure
• Stable, low drift performance • TO-5 can
voltage output vs %RH • Laser-trimmed more sensitive than standard structure.
• Accurate, fast response • Designed to Benefits: Combine both relative humidity Cased version designed to protect
be chemically resistant • Built-in static and temperature sensing for measuring against dust. Cost-effective performance
protection • Accuracy of ±3.5 % RH dew point and other absolute moisture in potential applications such as
• Voltage supply of 4 Vdc to 5.8 Vdc terms. Can-type housing designed refrigeration, drying, meteorology, battery-
• Stable, low drift performance • Slotted to provide quick response while still powered systems, and OEM assemblies.
TO-5 can maintaining robustness of enclosed

continued on page 4
Humidity Sensors Line Guide

Highly viable humidity


sensing solutions.
And every Honeywell S&C
Humidity Sensors
sensor contains something
HIH-4000 Series HIH-4602-L Series
no other supplier can offer:
Honeywell engineering and
expertise. This means an Description integrated circuit integrated circuit
unparalleled feature and Output analog voltage analog voltage
benefit set: A capacitive SIP (2,54 mm [0.100 in] or 1,27 mm
Package type slotted TO-5 can
sensing die set in thermoset [0.050 in] lead pitch)
polymers interacts with Response time 5 s 1/e in slow moving air 30 s 1/e in slow moving air
platinum electrodes. Laser- Operating temperature range -40 °C to 85 °C [-40 °F to 185 °F] -40 °C to 85 °C [-40 °F to 185 °F]
trimmed sensors designed Operating humidity range 0 % RH to 100 % RH 0 % RH to 100 % RH
to offer stable, low-drift Moisture/dust filter no no
performance and enhanced
Cover/case no yes
accuracy with calibration.
Calibration and data printout yes (some listings) yes (some listings)
Absorption-based humidity
Accuracy ±3.5 % RH ±3.5 % RH
sensors provide both
temperature and % RH. Voltage supply 4 Vdc to 5.8 Vdc 4 Vdc to 5.8 Vdc
Packages are chemically
resistant and operate in
ranges of -40 °C to 85 °C
[-40 °F to 185 °F] —
performing in most harsh
environments.

Most importantly, Honeywell


Humidity Sensors
S&C’s legendary engineering
expertise, proven product HIH-4602 A & C HCH-1000 Series
dependability, global reach
and support and superior monolithic IC with integral thermistor or
Description cased or uncased capacitive polymer
precision RTD
technical support deliver the
most critical advantage of all: analog voltage (for humidity),
Output capacitance value
resistance (for temperature)
reliable quality products for a
Package type TO-5 can SIP (2,54 mm [0.100 in] lead pitch)
lower total cost of ownership.
Response time 50 s 1/e in slow moving air 15 s at 30 % RH to 90 % RH
Operating temperature range -40 °C to 85 °C [-40 °F to 185 °F] -40 °C to 120 °C [-40 °F to 248 °F]
Operating humidity range 0 % RH to 100 % RH 0 % RH to 100 % RH
Moisture/dust filter yes (some listings) no
Cover/case yes yes (some listings)
Calibration and data printout yes (some listings) no
Accuracy ±3.5 % RH -
Voltage supply 4 Vdc to 5.8 Vdc -

2 www.honeywell.com/sensing
Humidity Sensors
HIH-4010/4020/4021 Series HIH-4030/4031 Series HIH-5030/5031 Series

covered or uncovered, filtered or covered, filtered or unfiltered integrated covered, filtered or unfiltered integrated
Description
unfiltered integrated circuit circuit circuit
Output analog voltage analog voltage analog voltage
SIP (2,54 mm [0.100 in] or 1,27 mm
Package type surface mount surface mount
[0.050 in] lead pitch)
Response time 5 s 1/e in slow moving air 5 s 1/e in slow moving air 5 s 1/e in slow moving air
Operating temperature range -40 °C to 85 °C [-40 °F to 185 °F] -40 °C to 85 °C [-40 °F to 185 °F] -40 °C to 85 °C [-40 °F to 185 °F]
Operating humidity range 0 % RH to 100 % RH 0 % RH to 100 % RH 0 % RH to 100 % RH
Moisture/dust filter yes (some listings) yes (some listings) yes (some listings)
Cover/case yes (some listings) yes yes
Calibration and data printout yes (some listings) yes (some listings) no
Accuracy ±3.5 % RH ±3.5 % RH ±3 % RH
Voltage supply 4 Vdc to 5.8 Vdc 4 Vdc to 5.8 Vdc 2.7 Vdc to 5.5 Vdc

www.honeywell.com/sensing 3
HIH-4010/4020/4021 Series. HIH-4030/4031 Series. HIH-5030/5031 Series.
Features: Voltage output • Near linear Features: Surface mount package Features: Surface mount package
voltage output vs % RH • Laser-trimmed • Voltage output • Near linear voltage • Voltage output • Operates at 2.7 Vdc
• Accurate, fast response • Molded output vs % RH • Laser-trimmed to 5.5 Vdc • Laser-trimmed • Accurate,
thermoset plastic housing • Designed to • Accurate, fast response • Molded fast response • Molded thermoset plastic
be chemically resistant • Accuracy of thermoset plastic housing • Designed to housing • Designed to be chemically
±3.5 % RH • Voltage supply of 4 Vdc to be chemically resistant • Tape and reel resistant • Tape and reel • Accuracy of
5.8 Vdc • Accuracy of ±3.5 % RH • Voltage supply ±3 % RH
of 4 Vdc to 5.8 Vdc
Benefits: Instrumentation-quality RH Benefits: Instrumentation-quality sensing
sensing performance in a competitively Benefits: Instrumentation-quality sensing performance in a competitively priced,
priced, solderable packages. Multilayer performance in a competitively priced, solderable surface mount device.
construction provides enhanced solderable surface mount device. Multilayer construction designed to
resistance to wetting, dust, dirt, oils and Multilayer construction designed to provide enhanced resistance to wetting,
common environmental chemicals. Laser provide enhanced resistance to wetting, dust, dirt, oils, and common environmental
trimmed for stable, low drift performance. dust, dirt, oils, and common environmental chemicals. Low current draw often ideal
Factory calibration data designed to chemicals. Low current draw often ideal in in most low drain, battery operated
provide individually matched downstream most low drain, battery operated systems. systems. Tight sensor interchangeability
electronics and accuracy (available on all Tight sensor interchangeability reduces reduces or eliminates OEM production
voltage output models). Available covered/ or eliminates OEM production calibration calibration costs. Tape and reel for high
uncovered and filtered/unfiltered for costs. Tape and reel for high volume volume applications (optional). Available
application flexibility in high volume OEM applications (optional). Factory calibration covered, filtered/unfiltered for application
condensing environments such as HVAC, data designed to provide individually flexibility in high volume OEM condensing
refrigeration, medical, office automation, matched downstream electronics and environments such as battery-powered
and telecommunications equipment. accuracy. Available covered, filtered/ systems, air compressors, HVAC,
unfiltered for application flexibility in high refrigeration, medical, office automation,
volume OEM condensing environments telecommunications equipment, and
such as HVAC, refrigeration, medical, weather meteorology equipment.
office automation, and telecommunications
equipment.

4 www.honeywell.com/sensing
Warranty. Honeywell warrants goods of While we provide application assistance
its manufacture as being free of defective personally, through our literature and WARNING
materials and faulty workmanship. the Honeywell web site, it is up to the PERSONAL INJURY
Honeywell’s standard product warranty customer to determine the suitability of the • DO NOT USE these products as
applies unless agreed to otherwise by product in the application. safety or emergency stop devices
Honeywell in writing; please refer to your or in any other application where
order acknowledgement or consult your Specifications may change without notice. failure of the product could result in
local sales office for specific warranty The information we supply is believed to personal injury.
details. If warranted goods are returned to be accurate and reliable as of this printing. Failure to comply with these
Honeywell during the period of coverage, However, we assume no responsibility for instructions could result in death or
Honeywell will repair or replace, at its its use. serious injury.
option, without charge those items it finds
defective. The foregoing is buyer’s sole For more information about Sensing and WARNING
remedy and is in lieu of all warranties, Control products, visit www.honeywell. MISUSE OF DOCUMENTATION
expressed or implied, including those com/sensing or call +1-815-235-6847 • The information presented in this
of merchantability and fitness for a Email inquiries to info.sc@honeywell.com catalogue is for reference only. DO
particular purpose. In no event shall NOT USE this document as product
Honeywell be liable for consequential, installation information.
special, or indirect damages. • Complete installation, operation and
maintenance information is provided
in the instructions supplied with each
product.
Failure to comply with these
instructions could result in death or
serious injury.

Sensing and Control


Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847 009034-2-EN IL50 GLO 