HEAT EXCHANGER SPECIFICATION SHEET Page 1

US Units

Job No.
Customer Reference No.
Address Proposal No.
Plant Location Date 15/08/2012 Rev
Service of Unit Item No.
Size 41,0000 x 360,000 inch Type AES Horz. Connected In 1 Parallel 1 Series
Surf/Unit (Gross/Eff) 7422,01 / 7339,54 ft2 Shell/Unit 1 Surf/Shell (Gross/Eff) 7422,01 / 7339,54 ft2
PERFORMANCE OF ONE UNIT
Fluid Allocation Shell Side Tube Side
Fluid Name Crudo 20% BSW Crudo 0.5% BSW
Fluid Quantity, Total lb/hr 278833 224574
Vapor (In/Out)
Liquid 278833 278833 224574 224574
Steam
Water
Noncondensables
Temperature (In/Out) F 169,00 186,55 235,00 210,16
Specific Gravity 0,9484 0,9484 0,9159 0,9159
Viscosity cP 250,00 250,00 28,600 28,600
Molecular Weight, Vapor
Molecular Weight, Noncondensables
Specific Heat Btu/lb-F 0,5700 0,5700 0,5000 0,5000
Thermal Conductivity Btu/hr-ft-F 0,1200 0,1200 0,0940 0,0940
Latent Heat Btu/lb
Inlet Pressure psia 90,000 60,000
Velocity ft/sec 0,37 0,47
Pressure Drop, Allow/Calc psi 10,000 3,905 10,000 1,473
Fouling Resistance (min) ft2-hr-F/Btu
Heat Exchanged Btu/hr 2789045 MTD (Corrected) 44,5 F
Transfer Rate, Service 8,54 Btu/ft2-hr-F Clean 8,57 Btu/ft2-hr-F Actual 8,57 Btu/ft2-hr-F
CONSTRUCTION OF ONE SHELL Sketch (Bundle/Nozzle Orientation)
Shell Side Tube Side
Design/Test Pressure psig 150,000 / 150,000 /
41,0000 inch
Design Temperature F
30,000 ft
No Passes per Shell 1 1
Corrosion Allowance inch
Connections In inch 1 @ 10,1920 1 @ 5,0470
Size & Out inch 1 @ 10,1920 1 @ 5,0470
Rating Intermediate @ @
Tube No. 1260 OD 0,7500 inch Thk(Avg) 0,0830 inch Length 30,000 ft Pitch 1,0000 inch Layout 30
Tube Type Plain Material CARBON-MOLY STEEL (0.1 C, 0.5 MO)
Shell ID 41,0000 inch OD inch Shell Cover
Channel or Bonnet Channel Cover
Tubesheet-Stationary Tubesheet-Floating
Floating Head Cover Impingement Plate None
Baffles-Cross Type SINGLE-SEG. %Cut (Diam) 45,0 Spacing(c/c) 40,0000 Inlet 38,0000 inch
Baffles-Long Seal Type
Supports-Tube U-Bend Type
Bypass Seal Arrangement Tube-Tubesheet Joint
Expansion Joint Type
Rho-V2-Inlet Nozzle 315,80 lb/ft-sec2 Bundle Entrance 72,42 Bundle Exit 72,42 lb/ft-sec2
Gaskets-Shell Side Tube Side
-Floating Head
Code Requirements TEMA Class
Weight/Shell 38434,0 Filled with Water 54768,7 Bundle 24381,3 lb
Remarks:

Reprinted with Permission (v5 )


C:\Users\DISEÑADOR\Dropbox\Flamingo\Intercambiador Crudo-Crudo Bater