OxiPro
In-Situ Flue Gas Oxygen Analyser

Control
your
boiler's
diet

lHigh Reliability lMaintenance Free lSimple Operation lEasy Installation lFactory Calibrated l24 month Warranty
Technical Description: Unique gold brazing technology ensures a gas-tight sensor
The OxiPro oxygen analyser package comprises a probe, combined with cell large surface area contributes to the
interconnecting cable and the microprocessor electronic increased O2 measuring accuracy and fast response from
unit for Boilers, Thermic fluid heaters, Furnaces, Kiln and the OxiPro oxygen analyser package.
Incinerator applications.
The microprocessor electronics is contained in a rugged
sheet metal housing for direct mounting in the boiler house.
OxiPro uses well-proven Zirconia oxide sensor technology The back-lit 16 digit LCD display has clear text with key pad
to measure O2% a direct indication of excess air % in flue selectable language options, providing easy operation for
gas. Zirconia sensor generates signal out put proportional end-users in other countries. Installation time is reduced to
to O2% as per Nernst equation a minimum with electrical cable connections simplified by
use of quick disconnect plug & socket.
The filter head assembly uses sintered stainless steel filter
element for standard applications and specially designed
filter for trouble free operation in high dust applications. The
built in calibration gas connection enables dynamic Technical Data Electronic Unit:
calibration under the process conditions.
Model: SME5
Construction: Sheet steel housing with window
W x H xD: 300 x 400x 210 (mm)
Technical Data Oxygen Measuring Probe: Protection: IP 65(Ex proof optional)
Model: KES 1000 Weight: 5 kg approx
Measuring principle: Zirconia oxide sensor Supply Voltage: 115V / 230V, 50/60Hz
Max. Flue gas temp.: 7600C (14000C Option) Power consumption: 100-200 VA (350 VA during start-up)
Immersion Length: 300mm, 500mm, 800 mm* Ambient temperature: -20 to + 550C
(7600C version) Measuring range: (0-100ppm) to (0-99)% O2, keypad
500mm* & 1000 mm* selectable
(14000C version) Output: 0/4 to 20mA, potential free, 500 ohms
*indicates use with a bypass max load
extension shield Overall
Cell Accuracy: less than 1ppm system accuracy: +/- 0.2% of measured value
Material: SS316Ti/ ss304 (1.4571/1.4301) Status signal: System fault relays, potential free
Probe Flange: Equal to DN 65 Pn6 Display: Back-lit 16 digit LCD clear text,
Probe Filter: Sintered / Ceramic Filter keypad selectable
Pressure: -50 to + 50 mbar Language Options: English, German, French & Spanish
Response Time: 0.5 secs @ 10 m/s flue gas Interconnecting cable: 6 m standard, other lengths on request
velocity
Electrical connection: Quick disconnect plug & socket Options
Protection: IP 65(Ex proof optional) Serial interface: RS232/RS485
Interconnecting cable: 6 m standard, other lengths on O2 Alarm: 3 separate outputs 230V/1A; each
request Programmable for high or low O2
values.

As per Probe length

Subject to change without notice XXXX/XX/XX/XXXX DOC.# PP/SPX/FGA/004/TI/01

Forbes Marshall Pvt. Ltd.


Mumbai-Pune Road, Kasarwadi, Pune 411 034. India.
Tel: 91(0)20 - 27145595lFax: 91(0)20 - 27147413lE - mail: environ@forbesmarshall.com
Branches: Ahmedabad, Alibag, Bangalore, Calcutta, Chennai, Coimbatore, Delhi,
Hyderabad, Jamshedpur, Mumbai, Nagpur, Navi Mumbai, Pune, Vadodara, Vishakhapatnam.
Area Reps: Bharuch,Bhopal, Chandigarh, Kolhapur, Lucknow, Mahad, Meerut, Pondicherry, Surat, Vadkhal.
URL: http://www.forbesmarshall.com

S-ar putea să vă placă și