GE

Power Conversion

MV Induction Motors
For industrial pump, fan, compressor
and other industrial applications.

NEMA Frames 5800-8000


500-7500 HP
IEC Frames 400-PV900
400-5600 kW
Experience Matters
For over 100 years, GE has produced countless medium voltage induction
machines for the petrochemical, power generation, mining and minerals, water
and wastewater industries. These motors are commonly used for centrifugal
compressors, blowers, boiler feed pumps, crushers and grinders, multi-stage high
pressure pumps such as water injection or pipeline applications.

Standards
GE motors are designed for, but are not limited
to these critical industry standards:
NEMA MG1
IEC 60034-1
ANSI C50.41
IEEE 112
API 541 & 547
Applicable ISO, AFBMA, ANSI, ASME, and ASTM requirements

Quality
Our world-class testing facility has the capability of meeting a wide range of NEMA,
IEC and API motor requirements. GE is dedicated to manufacturing excellence.
Our facilities are ISO 9001 Certified with over 20 years of Six Sigma process
enhancements and best practice implementations. Our commitment is to deliver
the highest quality design to fit your system requirements with service to exceed
your expectations.
Superior Design
Meets or exceeds API 541 Reduction of Resonances
requirements for Petroleum GE supplies both flexible and rigid rotor technology. All
& Chemical Applications machines 1800 rpm and below have rigid rotors as defined
GE provides machines that are fully compliant to API 541 by API. Use of the latest engineering simulation tools and
standards, globally recognized among the most stringent. modern modal testing equipment makes it possible for GE
You can be assured that you are getting a well-designed and to assure shaft resonances do not impede operation of the
reliable product, optimized for your specific application. machine in the specified speed range.

Inverter Duty
The insulation system meets the requirements of NEMA MG-1,
part 31. If required, a shaft grounding device is installed to
reduce shaft voltage. Both bearings are insulated and the
drive end bearing is grounded. Our cage induction motors are
certified for use with the GE MV4, MV6 and MV7000 range of
variable frequency drives.

Improved ventilation
and cooling has been
achieved with a new
internal fan design.

Stator frames are designed using powerful


FEA tools. The design tools confirm safety
margins, and assure resonances are well
outside the operating region.
Built for Durability
Stator Construction Rotor Construction
Laminations are precision punched from high quality, low loss The magnetic circuit consists of punched thin steel disks
electrical sheet steel with a temperature stable insulating film. assembled to form a laminated core mounted on the shaft. The
The magnetic core consists of ring laminations compressed laminations are coated with a temperature stable insulating
and completely wound before the core package is inserted film to reduce magnetic losses yet maintain dimensional
into the frame. stability in the face of severe thermal and mechanical stresses.
The rotor winding consists of a number of uninsulated metal
The stator assembly
bars in the outer surface of the magnetic core parallel to the
is configured for
increased air flow shaft and short circuited by metal rings at both ends.
which improves
heat transfer and
Copper bars are brazed
provides a more
to their endrings, and
compact design.
aluminum bars are
welded to their endrings.

Insulation System
GE uses an epoxy solventless resin vacuum-pressure-im-
pregnation (VPI) process assuring long life. For line voltages
of 5000 Volts and above, a semi-conducting armor is applied
to the slot portion and beyond the core to provide corona
protection. The binding agent is GE’s third generation epoxy
resin, selected and tested to IEEE-1776. The coils receive a
protective armor of heavy glass tape for protection against
®
Bearings
mechanical shock and abrasion. Custom Polyseal is a sealed GE uses self-aligning spherical seat sleeve bearings per DIN
winding insulation system that meets the requirements of 31693/4. Seal additions are also available to meet IP-56
NEMA MG1 20.18.. requirements. Anti-friction bearings are available with
Ground Wall
It is available upon Insulation grease in a sealed housing to avoid contamination meeting
request to operate in IP56 protection.
Turn
severe environments Insulation

containing moisture,
Strand
oil, chemicals and Insulation

salt water. Copper


Conductor

Self-aligning spherical seat sleeve bearings have features designed


to keep the oil in and the dirt out.
Vertical Wound Rotor
Accurate Frequency Response Design Energy Recovery System
System resonance can shorten the life of your equipment. GE wound rotor induction motors are designed to operate
GE invested in the development and calibration of a new with Slip Energy Recovery drives within a standard range of
Reed Critical Frequency (RCF) prediction tool. It arms our 80% to 110% of the rated speed. Every design is optimized
engineers with the accurate data they need to create custom to suit each application and to provide maximum energy
designs for specific application challenges. savings, effective speed control, and high reliability.

Frame Design - Benefits Rotor Construction


Large inspection windows on both ends of the frame ensure The rotor has a three-phase insulated winding. Rotor winding
easy maintenance and inspection access. The modular frame terminals are brought out through rotating slip rings and
design accommodates multiple cooling, bearing loading and stationery brushes. These terminals are used to connect
protection options without changing an external resistor in series with the rotor winding
the motor stator frame. in order to control the motor accelerating torque and
associated current.
Rotor Design
Shaft FEA modeling (including Torsional, Radial and Axial
loads) help ensure rotor designs meet specifed application
requirements.

Bearing Design
API compliant options are available for the rolling
element and sleeve bearing

Bearing
Upper Endshield Brush Lifting Device
In a traditional application as the motor achieves nominal
Stator
Chamber speed, the starting resistor is shorted out through the brushes
(Enclosed or Open Types) between the slip rings. This shortens the life of the brushes
and adds extra wear in the motor. An optional solution from
GE, called a Brush Lifting Device, is an integrated mechanism,
which shorts the slip rings and lifts the brushes at nominal
speed to avoid this wear.

Frame
Shaft

Rotor Lamination

Lower Endshield
Product Offering
Vertical MV Induction Motors
HP kW A* B* A B A B A B A B A B A B A B
500 370 8200 8200 8200 8200
1000 750 4 Poles 6 Poles 82008 Poles
8200 10 Poles
8200 8200 12
8200 Poles
8200 14
8200 Poles
8200 830016 Poles
8300 18 Poles
1500 1100 1800 RPM
8200 1200 RPM
8200 8200 900 RPM
8200 8200 720 RPM
8200 8200 600 RPM
8300 8300 514 RPM
8300 8300 450 RPM
8300 400 RPM
2000 1500 8200 8200 8200 8200 8200 8200 8300 8300 8300 8300 8300 8300
2500 1900 8200 8200 8200 8200 8300 8300 8300 8300 8300 8300 8500
3000 2200 8200 8200 8200 8300 8300 8300 8300 8300 8300 8500 8500
3500 2600 8200 8300 8300 8300 8300 8300 8300 8500 8500 8500 8500
4000 3000 8200 8300 8300 8300 8300 8500 8500 8500
4500 3400 8300 8300 8300 8300 8500 8500
5000 3700 8300 8300 8300 8300 8500 8500 8500
5500 4100 8300 8300 8300 8500 8500 8500
6000 4500 8300 8300 8500
6500 4900 8300
7000 5200 PV500
7500 5600 PV630
8000 6000 PV800
8500 6300 PV900

Horizontal Wound Rotor MV Induction Motors


HP kW A B A B A B A B
1000 750 8200 8200 8200 8200 8200 8200 8200 8200
1500 1100 6
8200 Poles
8200 8
8200 Poles
8200 6
8200 Poles
8200 8
8200 Poles
8200
2000 1500 82006600V
8200 82006600V
8200 82004000V
8200 82004000V
8200
2500 1900 8200 8200 8200 8200 8200 8200 8200 8200
3000 2200 8200 8200 8200 8300 8200 8200 8200 8300
3500 2600 8200 8300 8300 8300 8200 8300 8300 8400
4000 3000 8300 8300 8300 8400 8300 8300 8300 8400
4500 3400 8300 8400 8400 8400 8300 8400 8400 8400
5000 3700 8300 8400 8400 8300 8400 8400 8400
5500 4100 8400 8400 8400 8500 8400 8400 8400
6000 4500 8400 8500 8500 8500 8400 8400 8400
6500 4900 8400 8500 8500 8500 8400
7000 5200 8400 8500 8500 8500 8400 Weather Protected (WPI) - IP23
7500 5600 8500 8500 8500 8400
8000 6000 8500 8500 8500 (WPII) - IP24W and IP44W
8500 6300 8500 8500
9000 6700 8500 500
9500 7000 8500 560
10000 7500 8500 630
10500 7800 8500 710

Horizontal MV Induction Motors


HP kW A B A B A B
500 400 8200 8200 8200 8200 8200 8200
600 450 2
8200 Poles
8200 4
8200 Poles
8200 6
8200 Poles
8200
700 500 8200 8200 8200 8200 8200 8200
800 600 8200 8200 8200 8200 8200 8200
900 650 8200 8200 8200 8200 8200 8200
1000 750 8200 8200 8200 8200 8200 8300
1250 950 8200 8200 8200 8200 8300 8300
1500 1100 8200 8200 8200 8200 8300 8300
1750 1300 8200 8200 8200 8300 8300 8300
2000 1500 8200 8200 8300 8300 8300 8400
2250 1700 8200 8300 8300 8300 8300 8400
2500 1850 8300 8300 8300 8300 8300 8400
3000 2250 8300 8300 8300 8400 8400 8400 Weather Protected (WPI) - IP23 Totally Enclosed Water-to-Air Cooled
3500 2600 8300 8300 8300 8400 8400 8400 (WPII) - IP24W and IP44W (TEWAC) - IP54 or IP56
4000 3000 8300 8400 8400 8400 8400 8400
4500 3350
5000 3750 8400 8400 8400 8400 8400 8500
5500 4100 8400 8400 8400 8500 8500 8500
6000 4450 8400 8400 8400 8500 8500 8500
7000 5200 8400 8500 8500 8500 8500 8500
7500 5600 8500 8500 8500 8500 8500 8500

400
450
500
630

Ratings
60Hz. shown, 50Hz. Available. These ratings are based on
4.1 kV. Enclosures for other voltages may be sized differently.
Contact your GE representative for more information.

* Enclosures
A = WPI / WPII / TEWAC; IP23 / IP44W / IP54 / IP56
B = TEAAC; IP54 / IP56

Totally Enclosed Air-to-Air Cooled


(TEAAC) - IP54 or IP56
Global Expertise

Rotating Machine Factories


Converter Factories
Business Centers

Few manufacturers can claim the depth and


breadth of experience that GE has in building
and delivering electrical and mechanical
Proven Complete solutions for customers.
Experience Product
Offering

GE offers a complete portfolio


of rotating machines.
The GE
Advantage
GE has the global resources and capabilities
to maximize the performance and reliability
of your machines.
Innovative World-Class
Technology Service

GE is constantly innovating product


technologies to meet and exceed
customer expectations.
MAIN OFFICES

Australia, Botany Japan, Tokyo


Tel: +61 (0) 2 8313 9980 Tel: +81 3 5544 3852

Brazil, São Paulo Russia, Moscow


Tel: +55 11 3614 1930 Tel: +7 495 981 13 13

Canada, Mississauga Singapore


Tel: + 1 905 858 5100 Tel: +65 6332 0940

Chile, Santiago South Africa, Midrand


Tel: + 56 2 271 92200 Tel: +2711237 0000

China, Shanghai South Korea, Busan


Tel: +86 21 6498 2600 Tel: +82 51 710 9015

France, Massy UAE, Dubai


Tel: +33 1 77 31 20 00 Tel: +971 44296161

Germany, Berlin UK, Rugby


Tel: +49 30 7622 0 Tel: +44 1788 563 563

India, Chennai USA, Pittsburgh


Tel: +91 44 4968 0000 Tel: +1 412 967 0765

Additional Options
Monitoring/Protection/Accessories

Vibration displacement, velocity or acceleration


Temperature winding, cooling air, cooling water, bearing and bearing oil
Enclosure anti-condensation heaters, water leakage, differential pressure
Electrical current transformers, surge capacitors, surge arresters, partial discharge couplers
Mechanical soleplates, coupling guard supports, speed sensing

www.gepowerconversion.com