Sunteți pe pagina 1din 56

IndigoVision

8000 / 9000 Box


Hardware Guide
THIS MANUAL WAS CREATED ON JUNE 7, 2010
LEGAL CONSIDERATIONS
LAWS THAT CAN VARY FROM COUNTRY TO COUNTRY MAY PROHIBIT CAMERA SURVEILLANCE. PLE
ASE ENSURE THAT
THE RELEVANT LAWS ARE FULLY UNDERSTOOD FOR THE PARTICULAR COUNTRY OR REGION IN W
HICH YOU WILL BE
OPERATING THIS EQUIPMENT. INDIGOVISION LTD. ACCEPTS NO LIABILITY FOR IMPROPER OR
ILLEGAL USE OF THIS
PRODUCT.
COPYRIGHT
COPYRIGHT © 2010 INDIGOVISION LIMITED. ALL RIGHTS RESERVED.
THIS MANUAL IS PROTECTED BY NATIONAL AND INTERNATIONAL COPYRIGHT AND OTHER LAWS.
UNAUTHORIZED
STORAGE, REPRODUCTION, TRANSMISSION AND/OR DISTRIBUTION OF THIS MANUAL, OR ANY P
ART OF IT, MAY RESULT
IN CIVIL AND/OR CRIMINAL PROCEEDINGS.
INDIGOVISION IS A TRADEMARK OF INDIGOVISION LIMITED AND IS REGISTERED IN CERTAIN
COUNTRIES. ALL OTHER
PRODUCT NAMES REFERRED TO IN THIS MANUAL ARE TRADEMARKS OF THEIR RESPECTIVE OWNE
RS.
SAVE AS OTHERWISE AGREED WITH INDIGOVISION LIMITED AND/OR INDIGOVISION, INC., TH
IS MANUAL IS PROVIDED
WITHOUT EXPRESS REPRESENTATION AND/OR WARRANTY OF ANY KIND. TO THE FULLEST EXTEN
T PERMITTED BY
APPLICABLE LAWS, INDIGOVISION LIMITED AND INDIGOVISION, INC. DISCLAIM ALL IMPLIE
D REPRESENTATIONS,
WARRANTIES, CONDITIONS AND/OR OBLIGATIONS OF EVERY KIND IN RESPECT OF THIS MANUA
L. ACCORDINGLY, SAVE
AS OTHERWISE AGREED WITH INDIGOVISION LIMITED AND/OR INDIGOVISION, INC., THIS MA
NUAL IS PROVIDED ON AN
AS IS , WITH ALL FAULTS AND AS AVAILABLE BASIS. PLEASE CONTACT INDIGOVISION LIMITED (E
THER BY POST OR
BY E-MAIL AT PARTNER.SUPPORT@INDIGOVISION.COM) WITH ANY SUGGESTED CORRECTIONS AN
D/OR IMPROVEMENTS
TO THIS MANUAL.
SAVE AS OTHERWISE AGREED WITH INDIGOVISION LIMITED AND/OR INDIGOVISION, INC., TH
E LIABILITY OF
INDIGOVISION LIMITED AND INDIGOVISION, INC. FOR ANY LOSS (OTHER THAN DEATH OR PE
RSONAL INJURY) ARISING
AS A RESULT OF ANY NEGLIGENT ACT OR OMISSION BY INDIGOVISION LIMITED AND/OR INDI
GOVISION, INC. IN
CONNECTION WITH THIS MANUAL AND/OR AS A RESULT OF ANY USE OF OR RELIANCE ON THIS
MANUAL IS EXCLUDED
TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAWS.
TABLE OF CONTENTS

ABOUT THIS GUIDE................................................5


Safety Notices .................................................................
......6

1 GETTING STARTED.............................................. 7
Overview .......................................................................
........7
Powering the Unit ..............................................................
....7
Standard Temperature Range Units ...................................8
Extended Temperature Units ............................................10

2 CONFIGURATION ............................................... 13
Initial IP Properties ..........................................................
....13
Using the Web Configuration Pages ...................................13
Step 1 Preparing an Isolated Network...........................14
Step 2 Preparing PC for Initial Device Configuration....15
Step 3 Configuring your Transmitters/Receiver............17
Using the Serial Port Connection ........................................21
Attaching the Devices to the Network .................................24

3 HARDWARE DESCRIPTION .................................25


Connector Specification Front View ...............................25
IndigoVision 9000 Transmitter/Receiver Unit....................25
IndigoVision 9000 Transmitter Only Unit...........................26
IndigoVision 8000 Unit Transmitter Unit with Audio..........26
IndigoVision 8000 Transmitter Only Unit...........................27
IndigoVision 8000/9000 Extended Temperature Units......27
Composite Video Input/Output..........................................28
S-Video Input...................................................................
..28
Mic In..........................................................................
.......28
Line Input......................................................................
.....28
Line Output.....................................................................
...28
Indicator LEDs..................................................................
.29
Connector Specification Rear View ................................30
IndigoVision Standard Units ..............................................30
IndigoVision 9000 Extended Temperature Unit:
Option A........................................................................
.....30
IndigoVision 9000 Extended Temperature Unit:
Option B........................................................................
.....31
IndigoVision 8000 Extended Temperature Unit:
Option A........................................................................
.....31
IndigoVision 8000 Extended Temperature Unit:
Option B........................................................................
.....32
Network ........................................................................
.....32
Serial Ports ...................................................................
.....32
S-Video Connector Pinout .................................................34
Binary I/O Voltages Less Than 24 Volts............................34
Binary I/O Input Voltages Greater Than 24 Volts ..............36
Binary Output ..................................................................
..38
Power Supply ...................................................................
.38

4 HARDWARE SPECIFICATION...............................39
Video ..........................................................................
.........39
Audio ..........................................................................
.........40
Line Input/Output ..............................................................
...40
Mic Input ......................................................................
........40
Data Input/Output ..............................................................
..41
Network Connections ..........................................................41
Binary Input ...................................................................
......41
Binary Output ..................................................................
.....41
Metrics ........................................................................
.........42
Environment ....................................................................
....42
Regulatory .....................................................................
......43

APPENDIX A GENERAL PUBLIC LICENCE ........... 45

INDEX ................................................................. 47
ABOUT THIS GUIDE

This guide is written for users of the IndigoVision 8000 and 9000
units, and details the following product variants:

IndigoVision 9000 (H.264)


Transmitter-only unit
Transmitter/receiver unit with audio
As a receiver, this is a dual standard, 8000 and 9000 compatible unit.

IndigoVision 8000 (MPEG-4)


Transmitter-only unit
Transmitter with audio
Extended temperature
IndigoVision 8000 transmitter/receiver unit with audio
(options A and B)
IndigoVision 9000 transmitter/receiver unit with audio
(options A and B)
The information about each variant is identical unless otherwise stated.
This guide provides introductory information about the product,
and a description of the hardware and specifications.
For information on how to use the Web Configuration pages to
configure the unit, see the IndigoVision Web Configuration
Guide.
Safety Notices
This guide uses the following formats for safety notices:

Indicates a hazardous situation which, if not avoided, could result in


death or serious injury.
WARNING

Indicates a hazardous situation which, if not avoided, could result in


moderate injury, damage the product, or lead to loss of data.
CAUTION
NOTICE Indicates a hazardous situation which, if not avoided, may seriously
impair operations.

Additional information relating to the current section.


GETTING STARTED
Overview
IndigoVision s 1 Input transmitter/receiver 8000 and 9000 units
are a single source solution for transmitting, receiving, encoding
and decoding video, audio and binary events over IP networks.
They have the following key features:

As a transmitter, they digitize, encode and transmit video over


the network from a PAL or NTSC video source.
As a receiver, they receive the encoded video data from the
network, decompress the video signal and output either
NTSC or PAL composite video to an analog monitor.
They can be located at a camera location or remote
monitoring site.
IndigoVision s modular software products such as Control Center
and the Network Video Recorder (NVR) can be added at any
stage during the system s lifetime.
Powering the Unit
The standard temperature IndigoVision 8000 and 9000 units are
Power Over Ethernet (PoE) powered devices compliant with the
IEEE802.3af standard.
There are two extended temperature options: Option A units
operate from 0°C to +65°C. Option B units operate from -30°C to
+65°C and require an additional power supply to power an
internal heater.
Standard Temperature Range Units
There are four methods of powering the standard units:
Power over Ethernet (PoE) switch
PoE injector
PoE midspan
Auxiliary power
24V AC
14V-35V DC
Power over Ethernet (PoE) Switch
To power up the unit using a PoE-compliant switch, attach a
CAT5 cable between the unit and a PoE switch.
PoE Injector or Midspan
If a PoE switch is not available, the unit can be powered using a
PoE injector, such as Phihong PSA1GU-480, or midspan.
Cat5 cable Cat5 cable
Network switch
Network
PoE injector/
midspan
Mains Power
Mains Power
Figure 1 Using a PoE injector or midspan
Auxiliary Power
If power from a PoE Ethernet switch, PoE midspan or PoE
injector is not available, the unit can be powered using the
auxiliary power input. These are the two AUX pins of the 16-way
I/O connector on the rear of the unit.
Auxiliary power requirements are 24V AC or 14-35V DC
(7W max power). Figure 2 shows the signals on the I/O
connector.
D1.A D1.K
D2.A D2.K Ra.1 Ra.2 AUX +5V
D3.A D3.K
D4.A D4.K Rb.1 Rb.2 AUX GND
Figure 2
Binary I/O connector
Use 18AWG (1mm2) figure of eight or twisted pair cable to
connect an auxiliary power supply to the camera.
The auxiliary power input to the camera is not polarity sensitive;
therefore a DC power supply can be connected in either polarity
to the auxiliary pins.
NOTICE
The auxiliary power must be connected to the AUX pins only. The +5V
and GND pins must not be used for auxiliary power as this will
irrevocably damage the unit.
A 24V DC, 500mA PSU with mains power lead can be ordered
from IndigoVision. The order codes are 110004-1 (UK), 110004-2
(US), 110004-3 (EU).
For information on auxiliary power for extended temperature
units, see Auxiliary Power Supply on page 11
Extended Temperature Units
The extended temperature Option B units require additional 24V
AC or DC power input for heater power to ensure operation down
to -30°C.
The IndigoVision 8000 extended temperature units have a 5V DC
input for unit power.
For more information, see Connector Specification Rear
View on page 30

The power supply units provided with the unit are extended temperature
rated, however, they are not weather proof. You may need to mount the
power supply unit in a suitably IP rated enclosure.
CAUTION
5V DC Power Supply
The 5V DC power input with a current of up to 1.5A is provided
via a 2.1mm center-positive cylindrical connector, as shown in
Figure 3.
5V DC @ 1.5A
-+
Figure 3 Center-positive cylindrical connector
A locking power plug is available from:
Company: Switchcraft
Website: http://www.switchcraft.com
Part No: S761K
Description: Miniature power plug with securing screw
A power supply is provided with the IndigoVision 8000 extended
temperature units; part number 110009-1 (Uk), 110009-2 (US),
110009-3 (EU).
Auxiliary Power Supply
The auxiliary power (max power 8W) is provided via the two AUX
pins of the 16-way I/O connector on the rear of the unit (see
Figure 2).
For more information, see Auxiliary Power on page 8
Extended temperature units are supplied with 24V DC, 500mA
PSU with mains power lead: part number 110062-1 (UK),
110062-2 (US), 110062-3 (EU).
24V AC/DC Heater Power Supply
The 24V AC/DC power input with a current of up to 3.33A is
provided via a 2.5mm center-positive cylindrical connector, as
shown in Figure 4.
24V DC @ 3.33A
-+
Figure 4 Center-positive cylindrical connector
A locking power plug is available from:
Company: Switchcraft
Website: http://www.switchcraft.com
Part No: 761K
Description: Miniature power plug with securing screw
A heater power supply is provided with the 8000 and 9000
extended temperature Option B units; part number 110060-1
(UK), 110060-2 (US), 110060-3 (EU).
12
CONFIGURATION
You can configure your transmitter/receiver using the Web
Configuration pages, or a serial connection.
Initial IP Properties
By default, the devices are programmed with IP properties shown
in Table 1.
Table 1 Default IP Properties
Initial Configuration
IP Address 10.5.1.10
Subnet Mask 255.0.0.0
Default Gateway 10.0.0.1
Using the Web Configuration Pages
This section takes you through the steps required to configure
your IndigoVision transmitter/receiver unit using the Web
Configuration pages. These are as follows:
1
Prepare an isolated network.
2
Prepare your PC for initial device configuration.
3
Configure your transmitters and receivers. This includes
specifying their IP address and subnet mask.
Step 1 Preparing an Isolated Network
Connect the unit and the PC you are using to configure it on their
own isolated network by connecting them to the same PoE
switch (see Figure 5).
PC
PoE switch
Cat5 cable
Network
Network
Figure 5 Connecting the unit using a PoE switch
Alternatively, connect the unit to the PC via a PoE injector or
midspan (see Figure 6).
IN OUT
Cat5 crossover
cable
Cat5 cable
Network
PC
Mains Power Supply
PoE injector/
midspan
Figure 6 Connecting the unit using a PoE injector or midspan

When using 8000 series extended temperature units or if a PoE option


is not available, you will need to power the unit using an external power
supply. See Powering the Unit on page 7
Step 2 Preparing PC for Initial Device Configuration
All devices are supplied with their IP address and subnet mask
set to 10.5.1.10 and 255.0.0.0 respectively.

You cannot connect the devices to your network until you have changed
the IP settings to suit your network.
To change the factory defaults of your transmitter or receiver, you
must first (temporarily) modify your PC s network settings.

Record the original value of all settings that are to be changed so that
you can re-enter them when you have completed the initial device
configuration.
To change your PC s IP settings:
Use the Windows XP Network Settings configuration application
to set the PC s IP address and subnet mask, as follows:
1 In Windows Explorer, right-click Network Neighborhood and
select Properties.
2 Right-click Local Area Network and select Properties.

Figure 7 LAN Properties


3 Right-click Internet Protocol (TCP/IP) and select Properties.

Figure 8 IP Properties
4
Set the IP address to a unique address close to the factory IP
address, for example, 10.5.1.2 and change the PC s subnet
mask to 255.0.0.0 (the same as the factory default).
5
Click OK, then OK again.
Step 3 Configuring your Transmitters/Receiver
Once you have changed your PC s network settings, you can
change the IP values of your transmitter and receiver from the
factory defaults.
To configure a device using the Web Configuration pages:
1
Open Windows XP s Internet Explorer application. From the
File menu, select Open, and enter 10.5.1.10 (the factory
default IP address), then click OK.
2
The Web Configuration home page opens.

Figure 9 Web Configuration Home web page (9000 unit)


3 Click Network in the menu on the left of the page. The
Network web configuration page opens.

Figure 10 Network web configuration page (9000 unit)


The fields are as follows:

Use DHCP Select this check box if you wish to assign the
following Network parameters via a DHCP Server:
Host Name
IP Address
Subnet Mask
Gateway
Network Time Server
If the unit does not receive any response from the DHCP server it
will default to using the network parameters supplied by the last
completed DHCP request.

IndigoVision recommends that if you are using DHCP, you should


configure the DHCP server to assign a given IP address based on the
unit s MAC address.
NOTICE
Control Center requires that the IP address for a unit in a site remains
fixed. If the DHCP Server has been configured to lease addresses from
an address pool, rather than based on MAC address, the device will notwork corre
ctly with Control Center.

Host Name Enter a name for the transmitter or receiver to


identify the device.
Location Enter a location to identify the device.
IP Address Enter the IP address of the unit.
Subnet Mask Enter the IP network subnet mask.
NOTICE
Ensure that you enter the correct values. Once you change from the
defaults, the device is no longer configurable by the PC with its current
network settings.

Gateway Appropriate default gateway for remote network


access: this is only required if the devices are to be accessed
from a different subnet.
Broadcast Address Broadcast addresses are calculated
automatically using your IP address and subnet mask to
locate and access IndigoVision devices within a given range
of network IP addresses. This value is read-only.
NTP Server Address The IP address of a Network Time
Server, if used. If this is not automatically assigned using
DHCP, you can configure it manually on the Date/Time web
page.
Ethernet Interface Enter a link type. The options are as
follows:
10Mbps Half-Duplex
10Mbps Full-Duplex
100Mbps Half-Duplex
100Mbps Full-Duplex
Auto-negotiate
You may need to change the Ethernet link type default value
from Auto-negotiate for some network devices. If you have
problems maintaining a network link, contact your system
administrator to determine the appropriate setting.
When you have configured the device as required, click
Submit to apply the changes to the device.
4
To configure another device, disconnect the network cable
from the device. Leave the network cable connected to the
PC.

You may want to make a note of the device s new IP address and
subnet mask, or label the device with its new details.
5
Connect the network cable to the next device you want to
configure.
Before you can access the next unit for configuration, you
must type the following command from a Command Window:
C:> arp -d 10.5.1.10
6
Repeat these steps for each device, using different IP
addresses for each device.
NOTICE Ensure that no two devices share the same IP address (or that of the
PC).
7
When you have configured all your devices, return the PC to
its original settings, or change them as appropriate for your
network.
8
You are now ready to take your device(s) off the isolated
network and connect them to the main network. See
Attaching the Devices to the Network on page 24.
Using the Serial Port Connection
To configure the unit using the serial port, you require an RS232
null modem serial cable.
1
Power up the unit using the appropriate method, for example
Power over Ethernet (PoE).
See Powering the Unit on page 7
2
Connect the serial cable between the unit and the PC as
shown in Figure 11.
Serial cable
PC
Network
PC with serial
configuration software

Figure 11 Serial port connection


3
On the PC, use a Terminal Emulation program such as
Windows HyperTerminal and set the serial port parameters
as follows:

115200 baud
8 bits
No parity
1 stop bit
Flow Control: None
4
The console port defaults to being a serial data port. To revert
it back to a console port to configure the unit via this serial
port, connect to the unit and power on the device. You should
see similar output to the following:
Consider yourself BLOBed!
blob version 2.0.5-pre3-iv15 for IndigoVision VP887
Copyright (C) 1999 2000 2001 2002 Jan-Derk Bakker and Erik
Mouw
blob comes with ABSOLUTELY NO WARRANTY read the GNU GPL for
details.
This is free software, and you are welcome to redistribute
it under certain conditions; read the GNU GPL for details.
Memory map:
0x02000000 @ 0x00000000 (32 MB)
Loading blob from flash . done
Loading kernel from flash ... done
Loading fpga from flash ....... done
Autoboot (3 seconds) in progress, press <ESC> three times
to stop ...
To stop the normal boot procedure, press <ESC> three times
within the 3 seconds. To see the following prompt:
Autoboot aborted
Type "help" to get a list of commands
blob>

If you fail to do this in time power cycle the unit and repeat the
procedure.
At the blob prompt type the command "boot" to start the unit
and provide a serial console port.
blob> boot
5
Connect to the unit and press <Enter>. You should see a
prompt similar to the following:
VB9000 Vp-xxx Version vX-X-X
Device Type: Transmitter
Location: Unknown
Network Settings [10.5.1.10/255.0.0.0/10.0.0.1]
VB9000 login:

6
Log in to the unit using the username "config" and password
"config". The unit prompts you to enter the new configuration
values. At each prompt, press <Enter> to accept the current
value.
Use DHCP (y/n) Enter y to use DHCP for IP configuration,
or n for manual IP configuration.
IP Address Enter the IP address of the unit.
Subnet Mask Enter the IP network subnet mask.
Default Gateway Enter the appropriate default gateway
for remote network access: this is only required if the devices
are to be accessed from a different subnet.
Link type Enter a link type. The values are as follows:
0 - 10Mbps Half-Duplex
1 - 10Mbps Full-Duplex
2 - 100Mbps Half-Duplex
3 - 100Mbps Full-Duplex
4 - Auto-negotiate
You may need to change the Ethernet link type default value
from Auto-negotiate for some network devices. If you have
problems maintaining a network link, contact your system
administrator to determine the appropriate setting.

Host name Enter a name to describe the unit.


Location Enter a name to describe the location of the
unit.
Device type Choose to operate the unit as either a
transmitter or a receiver.
This option is not available on Transmitter only products.

Reset Network Security to factory defaults (y/n) ?


Enter "y" to reset the unit's password and network security
settings. This will enable unrestricted access to the
configuration web pages, and is the only way to reset the
password on the unit. Enter n if you do not want to make
changes to the unit's network security.
If you have more than one device, repeat these steps for each
device.
You are now ready to attach the device(s) to the network.
Attaching the Devices to the Network
After configuring the devices IP settings, you must attach the
transmitters and receivers directly to your network using an
available network port, as follows:
1
Reconnect your PC to the network.
2
Use a standard RJ45 connector and CAT5 cable to connect
to the network socket on the rear of the devices, as shown in
Figure 12.
PC
PoE switch
Cat5 cable
Network
Network
Figure 12 Connecting the unit using a PoE switch
Alternatively, you can connect the unit to the PC via a PoE
Injector or midspan (see Figure 13).
IN OUT
Network
PoE injector/
midspan
Cat5 cable
Cat5 crossover
cable
Mains power
supply
NetworkPC
Figure 13 Connecting the unit using a PoE injector or midspan

When using 8000 series extended temperature units or if a PoE option


is not available, you will need to power the unit using an external power
supply. See Powering the Unit on page 7
HARDWARE DESCRIPTION
This chapter describes the hardware for the IndigoVision 8000
and 9000 units.
Connector Specification Front View
IndigoVision 9000 Transmitter/Receiver Unit
Video In Video Out
S Video In
Figure 14 IndigoVision 9000 unit - transmitter/receiver
At the front of the unit, there are connector ports for the following:

Composite Video in
Composite Video out
S-Video in
Mic in
Line in
Line out
For an LED description, see Indicator LEDs on page 29.
IndigoVision 9000 Transmitter Only Unit
Video In
S Video In
Figure 15 IndigoVision 9000 unit - transmitter only
At the front of the unit, there are connector ports for the following:

Composite Video in
S-Video in
For an LED description, see Indicator LEDs on page 29
IndigoVision 8000 Unit Transmitter Unit with Audio
Video In Video Out
S Video In
Figure 16 IndigoVision 8000 unit - transmitter/receiver
At the front of the unit, there are connector ports for the following:

Video in
Video out not used (fitted with a blanking cap)
S-Video in
Mic in
Line in
Line out
For an LED description, see Indicator LEDs on page 29
IndigoVision 8000 Transmitter Only Unit
Video In
S Video In
Figure 17 IndigoVision 8000 unit - transmitter only
At the front of the unit, there are connector ports for the following:

Video in
S-Video in
For an LED description, see Indicator LEDs on page 29
IndigoVision 8000/9000 Extended Temperature Units
Video In Video Out
S Video In
Figure 18 IndigoVision 9000 unit - transmitter/receiver
At the front of the unit, there are connector ports for the following:

Composite Video in
Composite Video out
S-Video in
Mic in
Line in
Line out
For an LED description, see Indicator LEDs on page 29.
Composite Video Input/Output
The video connectors of the unit are standard 75 Ohm terminated
BNC connectors. The input/output format is composite video on
these connectors.
S-Video Input
For sources which support S-video, IndigoVision recommends
that you use this S-Video input to achieve high quality video at
lower bitrates.
Mic In
The units support both dynamic and condenser microphone
inputs, which are configurable from the audio web page. The
microphone input is a mono input.
The Mic In connector is a 3.5mm jack (stereo type), left channel
encoded only, that is, the audio input is on the Tip, and GND is
on the Common.
When using a condenser microphone, the microphone
power is provided on the centre connection of the jack.

If you are using a microphone source, ensure that you select the correct
type in the web page.
Line Input
The Line Input is a stereo input, 3.5mm jack (stereo type) and
supports an input signal amplitude of up to 1V p-p. The audio
input gain of the unit can be adjusted from the audio web page to
cater for lower input signal amplitudes.

Line in is set to mono by default. To switch to stereo, log in to the unit


via telnet, enter the command stereo on , then reboot the unit.
Line Output
The Line Output is a 3.5mm jack (stereo type) and provides an
output signal amplitude of up to 1V p-p. This output is not
capable of driving a speaker directly. It should be connected to a
suitable amplifier, powered speakers or headphones. The
minimum load impedance rating of this output is 32 Ohms.
Indicator LEDs
When the units are powered up, the LEDs indicate the activity
and status as described in Table 2.
Table 2 LED descriptions
Name Appearance Color Status Meaning
Activity

Yellow Flashing
Solid on/off
10/100
Green On
Off
Link
Yellow
Flashing
On
Off
Normal operation
System failure
100Base-TX mode
10Base-T mode
Ethernet link established, data
being transmitted/received
Ethernet link OK, no data being
transmitted/received
No Ethernet link
Connector Specification Rear View
IndigoVision Standard Units

Figure 19 IndigoVision 9000 unit rear view


At the rear of the unit, there are ports to connect to the following:

Network
Serial Console and Data ports
Binary I/O
IndigoVision 9000 Extended Temperature Unit: Option A

Figure 20 IndigoVision 9000 unit rear view


At the rear of the unit, there are ports to connect to the following:

Network
Serial Console and Data ports
Binary I/O
IndigoVision 9000 Extended Temperature Unit: Option B

Figure 21 IndigoVision 9000 extended temperature unit option B


At the rear of the unit, there are ports to connect to the following:
Network
Serial Console and Data ports
Binary I/O
Heater power supply (+24V AC/DC)
IndigoVision 8000 Extended Temperature Unit: Option A

Figure 22 IndigoVision 9000 extended temperature unit option A


At the rear of the unit, there are ports to connect to the following:

Network
Serial Console and Data ports
Binary I/O
Unit power supply (+5V DC)
IndigoVision 8000 Extended Temperature Unit: Option B

Figure 23 IndigoVision 9000 extended temperature unit option B


At the rear of the unit, there are ports to connect to the following:
Heater power supply (+24V AC/DC)
Network
Serial Console and Data ports
Binary I/O
Unit power supply (+5V DC)
Network
The network connector is an RJ-45 connector. It is auto-sensing
10/100 Base-T Ethernet. Use CAT5 cables or higher. The
maximum length is 100m.
Serial Ports
Console: 9-pin D-type
The Console Serial port is a standard RS232 serial connection
with pinouts as shown in Table 3.
Table 3 Console Serial port pinouts
Pin RS232 Function
1 NC
2 Rx
3 Tx
4 NC
Table 3 Console Serial port pinouts (continued)
Pin RS232 Function
5 GND
6 NC
7 NC
8 NC
9 NC
By default, the device boots using this port as a secondary data
port. To boot to the actual console follow the instructions in Using
the Serial Port Connection on page 21.

Data: 9-pin D-type


The Data Serial port can be either a standard RS232 (default)
port or an RS485/422 port.

The units support RS485 devices in a point-to-point configuration only.


No RS422/485 termination is provided. If this is required, it must be
provided externally.
Table 4 Data Serial port pinouts
Pin RS232 Function RS485/422 Function
1
2 Rx Rx+
3 Tx Tx4
5 GND GND
6
7 RTS Tx+
8 CTS Rx9
Parts
Suitable RS232 null modem cables are available from:

Company: Farnell
Website: http://www.farnell.com
Part No: 976880
Description: 9-way D-type female female serial cable
NOTICE Off-the-shelf null modem cables are not compatible with IndigoVision
devices when using RS422.
S-Video Connector Pinout
The pinout for the S-Video connector is as follows:

1 Y GND
2 C GND
3 Y (LUMA)
4 C (CHROMA)
Binary I/O Voltages Less Than 24 Volts
The binary inputs on the units allow you to connect external
trigger sources to the device. There are four binary inputs, and
two binary outputs.
For information on configuring alarms from binary inputs, please
see the IndigoVision Web Configuration Guide.
For supply voltages less than 24V DC, no external resistor is
required as the unit has an internal resistor fitted. The input
voltage (Vin) must be less than 1V DC, or open circuit, for a logic
low, and greater than 4V DC for a logic high.
Example 1 Normally Closed Contact
4 - 24V
VIN DX.A
DX.K
Normally closed
contact
Internal resistor
already fitted
IndigoVision
8000/9000
Figure 24 Normally closed contact
In Figure 24, when the switch is pushed, the binary input
changes from high to low. When the switch is released, the
binary input changes from low to high.
Example 2 Normally Open Contact
4 - 24V
VIN DX.A
DX.K
Normally open
contact
Internal resistor
already fitted
IndigoVision
8000/9000
Figure 25 Normally open contact
In Figure 25, when the switch is pushed, the binary input
changes from low to high. When the switch is released, the
binary input changes from high to low.
Binary I/O Input Voltages Greater Than 24 Volts
For input voltages greater than 24V DC, an external resistor is
required in series with the input pin. The value of this resistor can
be calculated as:
R = [ 100 * (VON - 1) - 1500 ] ohms rounded down to the nearest
preferred resistor value, where VON is the desired voltage for a
logic high.
eg. for VON = 48V DC
R = [ 100*( 48- 1 ) - 1500 ]
= 4700 - 1500 = 3200
~ 3K

CAUTION
Input voltages above 50Vpk at Vin will irrevocably damage the unit.
Example 3 Normally Closed Contact (48V input)
48V
Figure 26 Normally closed contact
In Figure 26, when the switch is pushed, the binary input
changes from high to low. When the switch is released, the
binary input changes from low to high.
VIN DX.A
DX.K
Normally closed
contact
3K
External
resistor
Internal resistor
already fitted
IndigoVision8000/9000
Binary I/O Connector Block
Figure 27 Binary I/O Connector Block
Name Type Description
D1-D4A Connector Block Diode 1- Diode 4 positive
D1-D4K Connector Block Diode 1- Diode 4 negative
RA1 RA2 Connector Block Switched terminals
RB1 RB2 Connector Block Switched terminals
+5v Connector Block +5V DC OUT
GND Connector Block Gnd
AUX Connector Block +24V AC/DC
NOTICE
The +5V DC connection on the connector block is a low current output
to be used for external BIO circuitry only. Max output current 15 mA.
12mA is required to operate 4 binary inputs.
The binary I/O connector block is available from:
Company: Phoenix Contact
Website: www.phoenixcontact.com
Part No: 1851106
Description: 8 position Spring Energy Plug
Company: Phoenix Contact
Website: www.phoenixcontact.com
Part No: 1850725
Description: 8 pin terminal block
Binary Output
Binary port switching is controlled via your software applications.
These ports are electronically switched and are either
open-circuit or closed. Once closed, the effective resistance
between Rx.1 and Rx.2 is not greater than 2 O. A typical example
is shown in Figure 28.
Figure 28 Example binary output
Rx.1
External Internal
I=500mA max
External
device
R=2 ohms
Rx.2
This port is not a voltage source. The maximum current permitted
through this port is 500mA, derated to 375mA at 50°C.
CAUTION
Power Supply
The standard IndigoVision 8000 and 9000 units are Power Over
Ethernet (PoE) powered devices compliant with the 802.3af
standard.
The extended temperature units can additionally have a 5V DC
input for unit power, and/or a 24V AC/DC to power a heater.
For more information, see Powering the Unit on page 7
HARDWARE SPECIFICATION
This chapter details the hardware specifications for the
IndigoVision 8000 and 9000 units.
Video

Composite video: 2 x BNC connectors


IVp-p 75Ohms, NTSC/PAL input when configured as a
transmitter
IVp-p 7Ohms, NTSC/PAL output when configured as a
receiver
S-Video input
Video Codec

IndigoVision 9000:
ITU-T H.264 Standard Baseline Profile
IndigoVision 8000:
ISO/IEC Standard MPEG-4 Simple Profile
User-configurable bit rate
User-configurable frame rate
4:2:0 YUV color space
Resolution

SIF
2SIF
4SIF
Audio
Audio Codec (not available on Transmitter only
products)

AAC-LC
16 kHz Sampling
Selectable 32, 48, 64 Kbps bit-rate
100 - 7000 Hz Bandwidth
Line Input/Output
Line Input

Stereo input
Maximum Input Voltage 1Vpp
3.5mm jack (stereo type)
For mono audio input, the input is on the Tip, and GND is on
the Common.
Line Output

Maximum Output Voltage 1Vpp


Minimum Output Load 32 Ohms
3.5mm jack (stereo type)
Mic Input

Mono input
Maximum input voltage: 200mVrms
3.5mm jack (stereo type)
Mono, left channel encoded. The audio input is on the Tip,
and GND is on the Common.
For condenser microphone, the power (4V DC) is on the
middle connection of the jack.
Data Input/Output
Data

Selectable EIA-574 RS232 or EIA-422 RS422/485


Maximum baudrate 115.2Kbps
Console/Data

EIA-574 RS232 only


Maximum Baud Rate 115.2 Kbps
Console Settings 115200, 8bits,1 Stop Bit, No Parity
Network Connections

IEEE 802.3 and IETF standards:


10/100 Base-T Ethernet, TCP, UDP, ICMP and IGMP
IEEE 802.3af standard
(not IndigoVision 8000 extended temperature units)
Power over Ethernet (PoE)
Physical connection via RJ-45
Binary Input

Four opto-isolated binary inputs


Maximum Input voltage 24V DC
To set a Binary Input High, VIN should be 4V DC minimum,
24V DC maximum (see Binary I/O Voltages Less Than 24
Volts on page 34)
To set a Binary Input Low, VIN should be 1V DC maximum
(see Binary I/O Voltages Less Than 24 Volts on page 34)
Binary Output

2 solid state relay outputs


Normally open relay outputs
Maximum ON resistance: 2 Ohms
Maximum carry current: 500mA@25°C, de-rated linearly to
375mA@50°C
Maximum voltage 50Vpk
+5V OUT @ 15mA max
Metrics
Dimensions

167mm (l) x 110mm (w) x 45mm (d)


Weight

0.6Kg (excluding power supply)


Power

Power over Ethernet (PoE)


Auxiliary power
24V AC
14-35V DC
Power consumption:
IndigoVision 8000: 6W max
IndigoVision 9000: 7W max
IndigoVision 8000 Extended Temperature: 7W max
IndigoVision 9000 Extended Temperature: 8W max
Environment
Standard variants:

Operating 0°C (32°F) to +50°C (122°F)


Storage -20°C (-4°F) to +70° (158°F)
Extended temperature variants:
Option A
Operating 0°C (32°F) to +65°C (149°F)
Storage -20°C (-4°F) to +70° (158°F)
Option B
Operating -30°C (-22°F) to +65°C (149°F)
Storage -30°C (-22°F) to +70° (158°F)
Regulatory

8000/9000 standard variants and 9000 extended temperature


variants:
EN 55022(1994) ITE emission standard Class B
EN 55024(1998) ITE immunity standard
CFR47(1995) Part 15 subpart B Class B(US federal
code of regulations)
8000 extended temperature variants:
EN 55022(1994) ITE emission standard Class A
EN 55024(1998) ITE immunity standard
EN 61000-3-2(1995) mains harmonics Class A
EN 61000-3-3(1995) voltage fluctuation
CFR47(1995) Part 15 subpart B Class A
In accordance with the EC Waste Electrical and
Electronic Equipment (WEEE) directive 2002/96/EC
this product must be sent to a recycling plant for proper
disposal at the end of its use.
44
GENERAL PUBLIC LICENCE
A
IndigoVision's 8000 and 9000 products use code that is freely
available under the General Public Licence (GPL).
This licence makes it a requirement to release changes made to
the source code. In compliance, the GPL source code and any
changes made by IndigoVision are available on request through
IndigoVision Customer Support.
46
INDEX

Numbers
8000 series
extended temperature option A
rear view 31
extended temperature option B
rear view 32
front panel 26
rear view 30
transmitter only front view 27
8000/9000 series
extended temperature front
view 27
9000 series
extended temperature option A
rear view 30
extended temperature option B
rear view 31
rear view 30
transmitter only front view 26
transmitter/receiver front
view 25
A
audio
specification 40
auxiliary power requirements 9
B
binary I/O connector block 37
binary inputs 34
specification 41
binary output
wiring 38
binary outputs 34
specification 41
codec
specifications 39
configuration
initial 13
serial port 21
Web Configuration pages 13
connectors
8000 extended temperature
option A 31
8000 extended temperature
option B 32
9000 extended temperature
option A 30
9000 extended temperature
option B 31
line input 28
line output 28
mic in 28
network 32, 41
power 38
standard unit 30
S-Video 28
video 28

console
specification 41
console serial port 32
D
data input/output specification 41
data serial port 33
data specification 41
devices
attaching to network 24
DHCP 18
dimensions
unit 42
E
environmental specification 42
F
front panel
8000 transmitter only 27
8000 transmitter with audio 26
8000/9000 extended
temperature 27
9000 transmitter only 26
9000 transmitter/receiver 25
G
general public licence 45
H
hardware
description 25
specification 39
I
IndigoVision 9000
hardware 25
initial IP properties 13
injector 8
IP properties 13
changing using serial port 21
changing using Web
Configuration pages 17
isolated network
preparing 14
L
LEDs 29
line input connector 28
line output connector 28
M
metrics 42
mic in connector 28
microphones 28
midspan 8
N
network
connections 41
connector 32
null modem cables 34
P
PC
preparing for configuration 15
pinout for S-Video connector 34
PoE
injector 8
midspan 8
switch 8

power connectors 38
power supply
24V AC/DC 11
5V DC 10
powering up 7
using a PoE injector 8
using a PoE switch 8
using auxiliary power 8
R
rear view
8000 extended temperature
option A 31
8000 extended temperature
option B 32
9000 extended temperature
option A 30
9000 extended temperature
option B 31
standard units 30
regulatory specification 43
resolutions specification 39
S
serial ports
console 32
data 33
specifications
audio 40
binary inputs 41
binary outputs 41
console/data 41
data input/output 41
environmental 42
regulatory 43
resolution 39
S-Video 39
video 39
S-Video
connectors 28
pinout 34
specification 39
U
unit
dimensions 42
V
video
connectors 28
specification 39
video codec
specifications 39
W
Web Configuration pages 13
wiring
binary output 38
50
51
Document ID:IU-IVBOX-MAN001-2