Fluid Condition

Monitoring Products

Global Filtration Technology


Introduction
In 1995, Parker became one of the first to successfully
market the concept of a portable particle counter, the Fluid Flow
PLC-2000. Since then, we have acquired UCC, Inc., a
recognized pioneer in condition monitoring equipment
such as the LCM20 particle counter and H2Oil
water-in-oil monitor. Laser

Along with the development of new, innovative Photo Diode Processor Report

products, such as the IQ200 dedicated on-line particle


counter and the MS100 moisture sensor, Parker has
grown into the industry leader for condition monitoring
products. A variety of both proven and leading-edge
products are now available for applications in both the
industrial and mobile marketplace.

Why on-site fluid condition


monitoring?
■ Certification of fluid cleanliness levels.
■ Early warning tool to help prevent catastrophic Visual Effects
failures in critical systems. of Water in Oil
■ Immediate results with laboratory accuracy.
■ To comply with customer cleanliness requirements
and specifications.
■ New equipment warranty compliance.
■ New oil cleanliness testing.
■ Identification of a fluid’s saturation point and/or
water content.
■ Continuous monitoring for water contamination. 1000 ppm
(.10%)

300 ppm
ISO 21/19/17 fluid ISO 16/14/11 fluid (.03%)
(magnification 100x) (magnification 100x)

Parker Hannifin Corporation


Hydraulic Filter Division
2 Metamora, OH
Parker Hannifin Corporation
Hydraulic Filter Division
3 Metamora, OH
IQ 200
Continuous on-line laser particle counter z1f3

The IQ200 particle counter is specifically designed to


provide continuous, on-line monitoring of the particulate
contamination level of hydraulic and lubrication fluids.

The small, compact IQ200 can connect to virtually


any system to give the user real-time data from every
3 seconds to 24 hours. The data is easily transferred and
organized to a laptop computer or PC station using the
supplied software. All of this for about 1/2 the price of
traditional portable particle counters.

■ Remote and multiple system monitoring from one location.

■ Completely automatic.
■ Laser accurracy and repeatability.
■ Programmable test intervals from 3 seconds to 24 hours.

■ Adjustable contamination level alarms.


■ Integral flow and calibration check.
■ ISO 4406-1999 reporting format (4, 6, 14 micron)
and correlation to NAS 1638.
■ User friendly Windows-based software.

■ Data displayed instantly in chronological or graphic form.

Parker Hannifin Corporation


Hydraulic Filter Division
4 Metamora, OH
Output data

ISO/NAS
alarms
Real time
fluid condition
report

ISO/NAS
User alarm setting
defined
sample
intervals

Real time particle


count graphing
with programmable
Specifications alarms
Pressure
3000psi (207 bar) maximum operating. Minimum pressure
required depends on fluid viscosity, connections, and
length of hose assemblies
Operating temperature
Maximum: 165°F(74°C)
Minimum: 32°F(0°C)
Flow thru sensor cell
Maximum allowed for accuracy: 60 ml/min
Minimum required for accuracy: 40 ml/min
Viscosity range
20-430 cSt (100-2000 SUS)
Inlet/outlet port connections
SAE-4 straight thread female
Particle size range
4+, 6+, 14+, 21+, 38+, 70+ microns
Output
RS-232/485 with 6 channels of particle counts and flow
rate, 1/2” - 20 UNF (BH-5 pin)
Power
12-24 VDC, 1/2” - 20 UNF (BH-4 pin)
Materials Ordering Information
Wetted: anodized aluminum. Viton seals. Display cover:
ABS thermoplastic PART # DESCRIPTION

Interface software (included) IQ200 On-line particle counter for mineral oils and petroleum based
Windows based data acquisition (LABWINDOWS CVI) fluids. Consult factory for phosphate/ester version availability.
Includes power cable, communication cable and software.
Size and weight
Consult factory for ISO 4406-1991 availability
67/8”D x 69/16”W 55/8”H / 12 lbs.
(2,5,15 micron format).

Parker Hannifin Corporation


Hydraulic Filter Division
5 Metamora, OH
LCM20
Portable Laser Particle Counter zf10

The new LCM20 is an engineered product progression from the original


best-selling CM20 “white light” particle counter. It is designed primarily
for on-line applications, with the flexibility for analyzing bottle
samples. Laboratory accuracy and repeatability, along with its user-
friendly operation, makes the LCM20 a great choice for your
portable particle counting needs.

Features
■ CE certified.
■ Weatherproof cover.
■ RS-232 communication port.

■ ISO 4406-1999 and correlation


to NAS 1638.
■ Lightweight (18 lbs.) and portable.
■ LCD display and hard copy printout.
■ Datum software included for
data transfer.
■ Bar code reader.

■ Removable hand-set for easy data entry.


■ 32-character alpha numeric data entry.
■ 2 minute testing time.

Parker Hannifin Corporation


Hydraulic Filter Division
6 Metamora, OH
Specifications
Ambient temperature Operating temperature
41°F(5°C) to 104°F(40°C) 41°F(5°C) to 176°F(80°C)
Calibration Pressure
Compliant with ISO 11171. Former ISO 4402 6000psi (414 bar) maximum
available upon request Power supply
Computer interface Battery operated with (6) alkaline “D” cells,
RS-232 communication port or 12VDC power supply, or rechargeable
Configuration battery pack
On-line laser automatic particle counter Report format
Light blockage ISO 4406-1999 and correlation to NAS 1638.
Data storage ISO 4406-1991 available upon request
300 test scrolling memory Sensitivity
Dimensions 4+, 6+, 14+, 21+, 38+, 70+ micron ranges.
9.75”L x 9.375” W x 5.00” D 2+, 5+, 15+, 25+, 50+, 100+ micron ranges
Displays available upon request
LCD readout, integral impact printer Software
Datum windows-based. Data compilation
Fluids and trending
Compatible with mineral oil and petroleum
based fluids. Skydrol/phosphate ester compatibility Testing
is optional 2 minutes flushing between tests. 10ml of fluid
tested. Counts multiplied to get reported values
Limitations per 100ml
Light blockage technology will not accurately work
Viscosity
with some high water content fluids. Excessive
To 465 SUS (100 cSt) with single point sampler
water contamination or aeration will also result in
invalid data Weight
Materials 17.6 pounds (8 Kg.)
Viton seals throughout. Kevlar hoses with SS ends 28.6 pounds (13 Kg.) with carrying case

Ordering Information
PART # DESCRIPTION
LCM20.2022 Portable on-line laser particle counter calibrated in accordance to
ISO 11171 with reports based on ISO 4406-1999 (4, 6, 14 format).
Mineral oil and petroleum based fluids only.
LCM20 Test LCM20.2062 Same as above. Phosphate ester and Skydrol only.
ON LINE LCM20.2021 Portable on-line laser particle counter calibrated in accordance to
ISO 4402 with reports based on ISO 4406-1991 (2, 5, 15 format).
TEST NUMBER 013
PLEASE ENTER A LCM20.2061 Same as above. Phosphate ester and Skydrol only.
LCM20 Test TEST ID CODE B.84.3702 Spare printer ribbon
ON LINE D M Y B.84.702 Spare printer paper rolls (5)
TEST NUMBER 013 Date 06-11-01 B.84.729 12 VDC power supply
PLEASE ENTER A Time 17-47
TEST ID CODE NAS CLASS 12(c) B.84.609 Replacement re-chargeable battery pack
D M Y Count/100ml B.84.779 Datum trending software
Date 06-11-01 4/6µ(c) 1914615 B.84.708 Cable and adapter
Time 17-47 6/14µ(c) 632092
ISO: 22/20/16(c) NAS CLASS 12(c)
Count/100ml 14/21/6µ(c) 26247
NAS CLASS 10(c)
>4/µ(c) 2579242 21/38µ(c) 5793
>6/µ(c) 664627 NAS CLASS 10(c) Standard LCM20 Components
>14/µ(c) 32535 38/70µ(c) 465
>21/µ(c) 6288 NAS CLASS 10(c) QUANTITY DESCRIPTION
>38/µ(c) 495 >70µ(c) 30 1 Heavy duty carrying case
>70/µ(c) 30 NAS CLASS 10(c)
6 “D” cell alkaline batteries
NOTES NOTES
1 Spare printer ribbon
2 Roll printer paper
ISO 4406-1999 Correlation to 1 Fuse
NAS 1638
1 Screwdriver
1 12V jack plug for DC power supply
1 Operation manual (English-French-Spanish)
1 Re-chargeable battery pack

Parker Hannifin Corporation


Hydraulic Filter Division
7 Metamora, OH
Universal Bottle Sampler
For use with the LCM20 particle counter
The UBS Universal Bottle Sampler is designed to attach
to the LCM20 particle counter, enabling the user to have
the flexibility of bottle sample particle counting and on-line
particle counting. Though generally not as accurate as on-
line particle counting, bottle sample particle counting is
fast and easy with the UBS attachment.

Specifications
• Fast/slow running speeds for varying viscosity oils
• Viscosities up to 580 SUS (125 cSt)
• Lightweight design for portability. 8.8 pounds (4Kg.)
• CE approved
• Mineral oil/petroleum based and phosphate ester/Skydrol versions available
• Operating temperature 41ºF (5ºC) to 176ºF (80ºC)

Ordering Information
PART # DESCRIPTION
UBS.9002 Universal bottle sampler kit. Includes attachments, vacuum
chamber, degassing pump, and travel case. For mineral oils and
petroleum based fluids.
UBS.9005 Same as above. For phosphate ester and Skydrol fluids.
B.89.910 Sample bottle kit (100 count).

Parker Hannifin Corporation


Hydraulic Filter Division
8 Metamora, OH
Single Point Sampler
For use with the LCM20 particle counter
The new SPS Single Point Sampler attachment to the
LCM20 is an easy means to allow the user a way to connect
the LCM20 to any pressurized flow system for particle
counting. The SPS is designed with a flow control
valve and connects with the hose assemblies on
the LCM20, enabling flow rate adjustment through
the LCD monitor. Once set, the SPS automatically
compensates for pressure changes in the system.

Specifications Ordering Information


• 6000 psi (414 bar) maximum pressure PART # DESCRIPTION
• CE certified SPS.2021 Single point sampler for mineral oil and petroleum based fluids.
• Mineral oil/petroleum based and phosphate ester/Skydrol versions available SPS.2061 Single point sampler for phosphate ester and Skydrol based fluids.
• Viscosities up to 2318 SUS (500 cSt)
• Small and lightweight. 1.1 pounds (.5 Kg)

System 20
sensors & monitors Sensor Specifications
• 6000 psi maximum pressure
For use with the LCM20 or separately • Size “0” SAE 6 ports, .5-7 gpm
• Size “1” SAE 12 ports, 2-26 gpm
System 20 inline sensors were developed to • Size “2” SAE 20 ports, 10-100 gpm
At maximum rated flow, pressure Ordering Information
provide dynamic simultaneous measurement of drop is 15 psi (1.4 bar)
System 20 Sensors
• Weights
flow, pressure, and temperature using an analog Size “0” 2 pounds (.9 Kg) PART # DESCRIPTION
Size “1” 7 pounds (3.2 Kg) STI.0344.100 Size “0”
or electronic hand-held monitor. The user Size “2” 10 pounds (4.5 Kg) Industrial sensor for oils and
• CE certified petroleum based fluids.
obtains data while the system is up and running. • Contruction is machined steel body with STI.1344.100 Size “1”
electroless nickel coating. Brass and SS
The LCM20 can obtain particle counts by being internal components.
Industrial sensor for oils and
petroleum based fluids.
connected to the System 20 inline sensors. Monitor Specifications STI.2344.100 Size “2”
• Analog or electronic Industrial sensor for oils and
• Kevlar-lined nylon hoses 39.4” (1000mm) long. petroleum based fluids.
• Flow reported in GPM/LPM dual scales. STI.0348.100 Size “0”
Industrial sensor for phosphate
• Pressure reported in PSI/bar dual scales.
Analog readings up to 6000psi (419 bar). ester and Skydrol.
Electronic readings up to 6000psi, with STI.1348.100 Size “1”
spikes up to 11,600psi (800bar). Industrial sensor for phosphate
• Temperature reported in °F/°C dual scales ester and Skydrol.
from 0°F +230°F (-18°C +110°C). STI.2348.100 Size “2”
Analog
• Size and Weight Industrial sensor for phosphate
11.5”L x 4.1”W x 2.9”D / 3lbs. ester and Skydrol.
• CE certified Ordering Information
• Electronic monitor uses (6) x AA batteries. System 20 Monitors
• Electronic Data Logging PART # DESCRIPTION
Electronic Test number, equipment description, time
and date, sensor size, flow, temperature, STM.6611.110 Analog monitor
and pressure. EM20.9000 Electronic monitor
• Electronic Data Download P.653607 Carrying case
Via RS-232 communication port to a
compatible PC. Also to a 16-column
serial printer.

Parker Hannifin Corporation


Hydraulic Filter Division
9 Metamora, OH
PLC-3000
Portable laser particle counter zfa01

The PLC-3000 portable laser particle counter is a


sampler (both on-line and bottle), sensor, and counter
packaged together to form a highly advanced portable
field instrument utilizing laboratory standards. It is
designed primarily as a bottle sampler, but has the
flexibility to become an on-line sampler without any
additional options.

Features
■ LCD and hard copy printout of results.
■ Internal thermal printer.
■ RS-232 computer communication
interface port.
■ ISO and NAS report formats.
■ AC operation with universal power
supply or DC operation with internal
NiCd battery.
■ On-line and bottle sampling in one
compact package.
■ Completely automatic “one touch”
testing procedure takes about 60 seconds.
■ Lightweight, rugged and portable for easy
on-site analysis.
■ Compressed air and CO2 connection for
bottle sampling flexibility.
■ ISO reporting in the 4/6/14 format.
■ Skydrol® and petroleum based fluid
compatibility with the same unit.
■ Windows based
software included
for data analysis
and trending.
■ CE approved.

Parker Hannifin Corporation


Hydraulic Filter Division
10 Metamora, OH
Specifications
Bottle Sampling Flow Method Report
Compressed air or CO2 cartridge. ISO 4406-1999 and NAS 1638.
Computer Interface ISO 4406-1991 available upon request.
RS-232 communication port and 9-pin to 9-pin Sensitivity
standard serial cable. 4+, 6+, 14+, 21+, 38+, 70+ micron ranges.
Data Storage 2+, 5+, 15+, 25+ 50+ 100+ micron ranges available
100 tests, scrolling memory. upon request.
Displays Software
LCD readout, integral thermal printer. Windows based, menu driven. Data compilation
Flexibility and trending.
On-line and bottle sampling as one package. Technology
No special connections or equipment needed. Automatic optical particle counting. Light blockage.
Flow Rate Temperature
Adjustable from 20-100ml per minute. Fluid, 165˚F (74˚C) maximum.
Fluids Ambient, 35°F (2°C) to 120° F (49°C).
Compatible with standard mineral and petroleum Testing
based fluids. Also compatible with phosphate ester 15 ml flush followed by (3) 10 ml runs averaged
(Skydrol) fluids. to give the cleanliness classifications. Particle
Light Source counts are reported per ml (ISO 4406) and 100 ml
5mV infrared laser diode. 300,000 hours typical life. (NAS 1638).
Limitations Testing Time
Light blockage technology will not accurately work 60 seconds at 50 ml/flow rate.
with some high water content fluids. High water Viscosity
contamination or excessive aeration will also result To 2000 SUS (430 centistokes).
in invalid data. Weight
Power Source 22 pounds (10 kilograms), 55 pounds (25 kilograms)
12 VDC rechargeable NiCd battery and 90-250 VAC with travel case.
universal power supply. Detachable power cord. On-line Sampling
Pressures to 6000 psi (414 bar) maximum.

Standard PLC-3000 Components


QUANTITY DESCRIPTION
1 Heavy duty portable travel case with protective foam
insert, tilt wheels and retractable handle Ordering
1 Universal power supply/battery charger with power cord DESCRIPTION P/N
2 68 gram C02 cartridges Portable particle counter PLC-3000
2 Rolls thermal printing paper 10-pack of 68 gram CO2 cartridges 601895
3 120 cc pre-cleaned sample bottles 25-pack of pre-cleaned 120cc sample bottles 601896
1 On-line sampling adapter Thermal printing paper 601897
1 RS-232 communication cable
1 Software
1 Operations manual

Sample: 00014 Parker PLC-3000 Sample: 00014 Parker PLC-3000 Sample: 00014 Parker PLC-3000
Date: 08/01/00 Time: 11:40:13 Date: 08/01/00 Time: 11:40:13 Date: 08/01/00 Time: 11:40:13
Sample Volume: 10ML/RUN Sample Volume: 10ML/RUN Sample Volume: 10ML/RUN
Flow Rate: 50ML/MIN Flow Rate: 50ML/MIN Flow Rate: 50ML/MIN
Reported Values: COUNTS/100ML Reported Values: COUNTS/ML Reported Values: COUNTS/ML

SIZE RANGE RUN1 RUN2 RUN 3 SIZE RUN1 RUN2 RUN 3 SMPL AVG SIZE RUN1 RUN2 RUN 3 SMPL AV G
6-14um(c): 200060 199190 198660 4um(c): 5467 5445 5425 5446.0 4um(c): 5467 5445 5425 5446.0
14-21um(c): 11160 10730 11280 6um(c): 2121 2121 2124 2126.7 6um(c): 2134 2121 2124 2126.7
21-38um(c): 2120 2160 2330 14um(c): 133 129 138 133.6 14um(c): 133 129 138 133.6
38-70um(c): 70 40 150 21um(c): 22 22 25 23.1
+100um(c): 10 0 40 38um(c): 0 0 1 1.0
70um(c): 0 0 0 0.2 ISO: 20/18/14

SAMPLE AVERAGE ISO: 20/18/14


6-14u(c): 199303.3 NAS: 10 NAS: 10
14-21u(c): 11056.7
21-38u(c): 2203.3
38-70u(c): 86.7
+70u(c): 16.7

Correlation to NAS 1638 Standard ISO 4406: 1999

Parker Hannifin Corporation


Hydraulic Filter Division
11 Metamora, OH
H22Oil
Water-in-Oil Monitor
Infrared Spectroscopy is one of the most fundamental
tools of laboratory analysis available and has been
widely used to provide analytical data on the composi-
tion of oils and the identification of contaminants such
as water. Sophisticated FTIR and dispersive instru-
ments can provide a picture of the total spectrum of an
oil and comparisons with spectra from an unused oil
will give valuable information concerning the oils
degradation. Oils will absorb infrared radiation
across the spectrum; the individual chemicals,
which make up the oil, absorb at one wave-
length or across a narrow band of wave-
lengths. Contaminants also absorb at
distinct wavelengths and, by monitoring
the part of the spectrum that the contami-
nants affect, changes in condition can be
seen and specific contaminants identified.
The H2Oil is the first portable 2-channel
non-dispersive infrared absorption spectrom-
eter designed specifically for the detection of
water. The unit can measure the content of water in
PPM (Parts Per Million) or percent water (%) and the
detection range is 0 to 3,000 PPM or 0 to 3% absorbed

■ Accurate measurement of low levels


of water contamination in oil.
■ On-line operation to 6000 psi (414 bar).

■ Results displayed as percentage water


content or parts per million.
■ RS 232 communications port.
■ Optional oil delivery kit for customer
offline oil sampling.
■ 0-3000 ppm absorbed water detection.
■ Easy use with System 20 sensors or
SPS single point sampler.

Parker Hannifin Corporation


Hydraulic Filter Division
12 Metamora, OH
water depending on the oil type. The integral hoses allow
the H2Oil to measure the water content in a dynamic
flowing system with pressures as high as 6,000 psi having
no impact on the users systems’ performance. As a non- Specifications
Test Cycle:
dispersive spectrometer, the unit can store up to 20 90 seconds
specific oil calibration curves. Each unit comes with 15 Test Modes:
Single test
generic calibration curves loaded for the standard ISO Data logging at user defined time intervals
Continuous sampling
grade oils. At the same time the unit can store 20 Computer controlled testing
Detection Range:
different sample identifiers for data trending. 0 – 3,000 PPM
Maximum Working Pressure:
Once connected to a flowing system the monitor 6,000 psi
will produce results in 90 seconds. Within the 90 Data Entry:
Via built-in key pad to back-lit display
seconds the monitor will take six readings, three Repeatability/Accuracy:
Better than 5% (typical)
from the reference and three from the measure-
Memory:
ment filter, if the results are within the allowable 500 test (scrolling) capacity
Data Retrieval:
limits the result will be displayed. If the test results Via RS232 port or direct access via
alphanumeric keypad
are out of tolerance then the unit will take one more
Power:
test to succeed, if it fails the error message of “sample 12VDC rechargeable batteries (2 supplied)
Fluid Compatibility:
inconsistent” will appear. With the H2Oil’s internal error Mineral oil and petroleum based fluids;
messaging it will keep the user informed of the monitor’s all others consult the factory
Size and Weight:
performance and how to resolve any issue. 9.25”L x12.51”W x7.09” D / 13 lbs.

Ordering Information
Part # Description
WOM.9100 H2Oil Water-in-Oil Monitor
B.91.701 Spare printer paper (5 rolls/bx)
S.840134 Oil delivery unit

Parker Hannifin Corporation


Hydraulic Filter Division
13 Metamora, OH
MS100
Water enters hydraulic and lubricating systems from a variety zf12

of sources. Atmospheric ingression of water vapor, as well as Specifications


Pressure
internal heat exchanger leaks, create unfavorable operating Maximum allowable operating pressure
conditions. The MS100 Moisture Sensor eliminates the guess- (MAOP): 150 psi (10 bar)
Operating temperature
work by providing real time condition monitoring. It is designed Maximum: 180°F(82°C)
to work well in petroleum/synthetic hydraulic and lubricating Minimum: -40°F(-40°C)
Flow thru sensor cell
oil applications. Installed in active flowstream
Fluid compatibility
Mineral oils and petroleum-based phosphate
ester and Skydrol
Viscosity range
Unlimited
Port connection
1/2” NPT or SAE-10
Outputs
0-5 VAC
Power
24 VDC, 1/2” - 20 UNF (BH-5 pin)
Materials
6061 T6 anodized aluminum
Sensor size and weight
4.693”H x 1.588”D / .5 lbs.

Sensor zfa04 Ordering Information


PART # DESCRIPTION
935709 MS100 moisture sensor only 1/2” NPT
935710 MS100 moisture sensor only SAE-10
935756 MS100 kit. Includes 1/2” NPT sensor,
Remote indicator display power distribution module, remote
indicator display, and cables
Interpreting Data
935011 MS100 kit. Includes SAE-10 sensor
Kit power distribution module, remote
The Parker MS100 Moisture Sensor is designed to provide real time, indicator display, and cables
accurate and repeatable results reported as % saturation of water.
Percent saturation is a useful measurement that offers the user a
simple, quantitative method in determining how wet or dry a
hydraulic or lubricating system may be. In contrast, PPM and % ■ Parker’s MS100 Moisture Sensor provides a com
water by volume measurements provide little information about a
fluid’s free or dissolved water condition. However, % saturation can
pact, real time solution to continuous water
be converted to PPM as long as the fluid’s saturation point is known contamination monitoring
at the system operating temperature.
Example ■ Simple LED’s provide local Go/No-Go indication
Oil type: Texaco Rando 46
Saturation point: 400ppm @ 150º ■ Panel meter for local or remote display reports
At the above operating condition, the meter displays 100% 0-100% saturation
saturation. As the meter’s scale indicates a reduction in the
saturation percentage, there is also a corresponding reduction ■ Meter scale is color coded for positive/easy
in PPM at a constant temperature. In the example above, a
meter reading of 50% saturation could be interpreted as identification
200ppm at 150ºF.
Sensor
■ Power distribution module provides 0-10 VDC
Using only the sensor as a go/no-go device, a blue LED will analog and 120 VAC logic output
indicate when the oil’s water concentration reaches ≥ 80%
saturation and trigger a corresponding voltage output.
The unit also features an analog output proportional to %
Saturation with a dynamic range of 0.8 to 3.8 volts.
Example: <0.8V = Fault
0.8V = 0% Saturation
2.3V = 50% Saturation
3.8V = 100% Saturation
4.1V = >100% Saturation
4.3V = Fault

Parker Hannifin Corporation


Hydraulic Filter Division
14 Metamora, OH
APPENDIX
Changes to ISO Standards Chart 1 – ISO Comparison
and their impact on Filter
Performance Reporting and Former two-digit ISO 4406:1987
the Contamination Code 5 µm / 15 µm
14 / 11
The recent changes to ISO contamination and
filtration standards were brought about to solve Former three-digit ISO 4406:1987
2 µm / 5 µm / 15 µm
accuracy, traceability, and availability issues. It
17 / 14 / 11
is important to remember that both real world
hydraulic system cleanliness levels and actual New three-digit ISO 4406:1999
4 µm (c) / 6 µm (c) / 14 µm (c)
system filter performance remain unchanged.
18 / 14 / 11
However, the reporting of cleanliness levels and
filter performance has changed due to the new
particle counter calibration and multi-pass test
procedures. Chart 2 – Particle Size Comparison

ISO 11171 is the new particle counter calibra- ACTFD size NIST size
tion method and utilizes calibration fluid made (per ISO 4402:1991) (per ISO 11171:1999)
µm µm (c)
from ISO Medium Test Dust (ISO MTD) sus-
1 4.2
pended in MIL-H-5606. The calibration fluid is
2 4.6
traceable to the National Institute of Standards
3 5.1
and Technology (NIST) and is designated by 5 6.4
NIST as Standard Reference Material (SRM) 7 7.7
2806. ISO 11171 is replacing ISO 4402 which is 10 9.8
based on obsolete AC Fine Test Dust (ACFTD). 15 13.6
20 17.5
It is important to note that the ISO 11171 25 21.2
calibration method is based on a distribution 30 24.9
of particles measured by their equivalent area 40 31.7
diameter, whereas ISO 4402 is based on a
distribution of particles measured by their
longest chord. Also, the NIST work utilized
scanning electron microscopy for particles
below 10 µm in size, whereas the sizing
distribution on ACFTD utilized optical
microscopy.
The charts to the right show the approximate
particle size relationship between the
calibration methods.

Parker Hannifin Corporation


Hydraulic Filter Division
15 Metamora, OH
Parker Worldwide Filtration Group Technical
Sales Offices Sales & Service Locations
Contact Parker’s worldwide service
and distribution network by calling: Finite Filter Division Hydraulic Filter Division Europe
500 Glaspie Street Churwell Vale
Argentina • +54 (1) 752 4129 Oxford, Ml 48371 Shaw Cross Business Park
Australia • +61 (2) 634 7777 Phone: (248) 628-6400 Dewsbury, England WF12 7RD
Austria • +43 (2622) 23501 5 Fax: (248) 628-1850 Ph: 44 (0) 1924 487000
Belgium • +32 (2) 762 1800 Fax: 44 (0) 1924 487060
Brazil • +55 (11) 3917 1407 Hydraulic Filter Division
Canada • 1-800-272-7537 North America Hydraulic Filter Division Europe
China • +86 (21) 6445 9339 16810 Fulton County Road #2 UCC Products
Chile • +(562) 623-1216 Metamora, OH 43540 P.O. Box 3
Czech Republic • +42 613 41701 Phone: (800) 253-1258 Thetford, Norfolk
Denmark • +45 (43) 541133 Phone: (419) 644-4311 IP24 3RT England
Finland • +358 (3) 54 100 Fax: (419) 644-6205 Ph: 44 (0) 1842-754251
France • +33 (4) 50 258025 Fax: 44 (0) 1842-753702
Germany • +49 (3727) 90991 Process Filtration Division
Hong Kong • +852 2428 8008 6640 Intech Blvd. Finn Filter Division
Hungary • +36 (1) 25 22 539 Indianapolis, IN 46278 Fin-31700
India • +91 (22) 577 1671 Phone: (888) 238-5356 Urjala As., Finland
Italy • +39 (2) 451921 Phone: (317) 275-8300 Phone: (358) 3 54 100
Japan • +81 (45) 861 3811 Fax: (317) 275-8410 Fax: (358) 3 54 10100
Korea • +82 (2) 561 0414
Mexico • 1-800-272-7537 Racor Division Parker Hannifin Ind. e Com.
Netherlands • +31 (541) 58500 3400 Finch Road Ltda. Filter Division
NewZealand • +64 (9) 573 1523 P.O. Box 3208 Via Anhanguera, Km.25,3
Norway • +(47) 64 86 77 60 Modesto, CA 95353 05276-977 - Sao Paulo
Poland • +48 (22) 8634942 Phone: (800) 344-3286 – SP, Brazil
Singapore • +65 261 5233 Phone: (209) 521-7860 Phone: +55 (11) 3917 1407
South Africa • +27 (11) 3927280 Fax: (209) 529-3278 Fax: +55 (11) 3917 1623
Spain • +34 (1) 6757300
Sweden • +46 (8) 760 2960 Racor Division Parker Hannifin Korea Limited
Taiwan • +886 (2) 8787 3780 Hydrocarbon Products 902 Dae Heung Bldg.
United Arab Emirates • +971 (2) 788587 Route #3 Box 9 648-23 Yeoksam-dong
United Kingdom +44 1442 238100 Henryetta, OK 74437 Kangnam-ku, Seoul,
United States of America • 1-800-272-7537 Phone: (918) 652-4481 Korea 135-080
Venezuela +58 (2) 238 5422 Fax: (918) 652-8882 Tel: 82 2 561 0414
Fax: 82 2 556 8187
! WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED
ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system
options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the
information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these
products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change
by Parker Hannifin Corporation and its subsidiaries at any time without notice.

Offer of Sale
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors.
This offer and its acceptance are governed by the provisions stated in the "Offer of Sale".

Parker Hannifin Corporation Brochure No. 2300-420


Hydraulic Filter Division 10M1/02
Printed in USA
16810 Fulton County Road #2
Metamora, OH 43540
Phone: (800) 253-1258
Phone: (419) 644-4311
Fax: (419) 644-6205 Parker Hannifin Corporation
http://www.parker.com/hydraulicfilter Hydraulic Filter Division
16 Metamora, OH

S-ar putea să vă placă și