Documente Academic
Documente Profesional
Documente Cultură
Monitoring Products
Along with the development of new, innovative Photo Diode Processor Report
300 ppm
ISO 21/19/17 fluid ISO 16/14/11 fluid (.03%)
(magnification 100x) (magnification 100x)
■ Completely automatic.
■ Laser accurracy and repeatability.
■ Programmable test intervals from 3 seconds to 24 hours.
ISO/NAS
alarms
Real time
fluid condition
report
ISO/NAS
User alarm setting
defined
sample
intervals
Interface software (included) IQ200 On-line particle counter for mineral oils and petroleum based
Windows based data acquisition (LABWINDOWS CVI) fluids. Consult factory for phosphate/ester version availability.
Includes power cable, communication cable and software.
Size and weight
Consult factory for ISO 4406-1991 availability
67/8”D x 69/16”W 55/8”H / 12 lbs.
(2,5,15 micron format).
Features
■ CE certified.
■ Weatherproof cover.
■ RS-232 communication port.
Ordering Information
PART # DESCRIPTION
LCM20.2022 Portable on-line laser particle counter calibrated in accordance to
ISO 11171 with reports based on ISO 4406-1999 (4, 6, 14 format).
Mineral oil and petroleum based fluids only.
LCM20 Test LCM20.2062 Same as above. Phosphate ester and Skydrol only.
ON LINE LCM20.2021 Portable on-line laser particle counter calibrated in accordance to
ISO 4402 with reports based on ISO 4406-1991 (2, 5, 15 format).
TEST NUMBER 013
PLEASE ENTER A LCM20.2061 Same as above. Phosphate ester and Skydrol only.
LCM20 Test TEST ID CODE B.84.3702 Spare printer ribbon
ON LINE D M Y B.84.702 Spare printer paper rolls (5)
TEST NUMBER 013 Date 06-11-01 B.84.729 12 VDC power supply
PLEASE ENTER A Time 17-47
TEST ID CODE NAS CLASS 12(c) B.84.609 Replacement re-chargeable battery pack
D M Y Count/100ml B.84.779 Datum trending software
Date 06-11-01 4/6µ(c) 1914615 B.84.708 Cable and adapter
Time 17-47 6/14µ(c) 632092
ISO: 22/20/16(c) NAS CLASS 12(c)
Count/100ml 14/21/6µ(c) 26247
NAS CLASS 10(c)
>4/µ(c) 2579242 21/38µ(c) 5793
>6/µ(c) 664627 NAS CLASS 10(c) Standard LCM20 Components
>14/µ(c) 32535 38/70µ(c) 465
>21/µ(c) 6288 NAS CLASS 10(c) QUANTITY DESCRIPTION
>38/µ(c) 495 >70µ(c) 30 1 Heavy duty carrying case
>70/µ(c) 30 NAS CLASS 10(c)
6 “D” cell alkaline batteries
NOTES NOTES
1 Spare printer ribbon
2 Roll printer paper
ISO 4406-1999 Correlation to 1 Fuse
NAS 1638
1 Screwdriver
1 12V jack plug for DC power supply
1 Operation manual (English-French-Spanish)
1 Re-chargeable battery pack
Specifications
• Fast/slow running speeds for varying viscosity oils
• Viscosities up to 580 SUS (125 cSt)
• Lightweight design for portability. 8.8 pounds (4Kg.)
• CE approved
• Mineral oil/petroleum based and phosphate ester/Skydrol versions available
• Operating temperature 41ºF (5ºC) to 176ºF (80ºC)
Ordering Information
PART # DESCRIPTION
UBS.9002 Universal bottle sampler kit. Includes attachments, vacuum
chamber, degassing pump, and travel case. For mineral oils and
petroleum based fluids.
UBS.9005 Same as above. For phosphate ester and Skydrol fluids.
B.89.910 Sample bottle kit (100 count).
System 20
sensors & monitors Sensor Specifications
• 6000 psi maximum pressure
For use with the LCM20 or separately • Size “0” SAE 6 ports, .5-7 gpm
• Size “1” SAE 12 ports, 2-26 gpm
System 20 inline sensors were developed to • Size “2” SAE 20 ports, 10-100 gpm
At maximum rated flow, pressure Ordering Information
provide dynamic simultaneous measurement of drop is 15 psi (1.4 bar)
System 20 Sensors
• Weights
flow, pressure, and temperature using an analog Size “0” 2 pounds (.9 Kg) PART # DESCRIPTION
Size “1” 7 pounds (3.2 Kg) STI.0344.100 Size “0”
or electronic hand-held monitor. The user Size “2” 10 pounds (4.5 Kg) Industrial sensor for oils and
• CE certified petroleum based fluids.
obtains data while the system is up and running. • Contruction is machined steel body with STI.1344.100 Size “1”
electroless nickel coating. Brass and SS
The LCM20 can obtain particle counts by being internal components.
Industrial sensor for oils and
petroleum based fluids.
connected to the System 20 inline sensors. Monitor Specifications STI.2344.100 Size “2”
• Analog or electronic Industrial sensor for oils and
• Kevlar-lined nylon hoses 39.4” (1000mm) long. petroleum based fluids.
• Flow reported in GPM/LPM dual scales. STI.0348.100 Size “0”
Industrial sensor for phosphate
• Pressure reported in PSI/bar dual scales.
Analog readings up to 6000psi (419 bar). ester and Skydrol.
Electronic readings up to 6000psi, with STI.1348.100 Size “1”
spikes up to 11,600psi (800bar). Industrial sensor for phosphate
• Temperature reported in °F/°C dual scales ester and Skydrol.
from 0°F +230°F (-18°C +110°C). STI.2348.100 Size “2”
Analog
• Size and Weight Industrial sensor for phosphate
11.5”L x 4.1”W x 2.9”D / 3lbs. ester and Skydrol.
• CE certified Ordering Information
• Electronic monitor uses (6) x AA batteries. System 20 Monitors
• Electronic Data Logging PART # DESCRIPTION
Electronic Test number, equipment description, time
and date, sensor size, flow, temperature, STM.6611.110 Analog monitor
and pressure. EM20.9000 Electronic monitor
• Electronic Data Download P.653607 Carrying case
Via RS-232 communication port to a
compatible PC. Also to a 16-column
serial printer.
Features
■ LCD and hard copy printout of results.
■ Internal thermal printer.
■ RS-232 computer communication
interface port.
■ ISO and NAS report formats.
■ AC operation with universal power
supply or DC operation with internal
NiCd battery.
■ On-line and bottle sampling in one
compact package.
■ Completely automatic “one touch”
testing procedure takes about 60 seconds.
■ Lightweight, rugged and portable for easy
on-site analysis.
■ Compressed air and CO2 connection for
bottle sampling flexibility.
■ ISO reporting in the 4/6/14 format.
■ Skydrol® and petroleum based fluid
compatibility with the same unit.
■ Windows based
software included
for data analysis
and trending.
■ CE approved.
Sample: 00014 Parker PLC-3000 Sample: 00014 Parker PLC-3000 Sample: 00014 Parker PLC-3000
Date: 08/01/00 Time: 11:40:13 Date: 08/01/00 Time: 11:40:13 Date: 08/01/00 Time: 11:40:13
Sample Volume: 10ML/RUN Sample Volume: 10ML/RUN Sample Volume: 10ML/RUN
Flow Rate: 50ML/MIN Flow Rate: 50ML/MIN Flow Rate: 50ML/MIN
Reported Values: COUNTS/100ML Reported Values: COUNTS/ML Reported Values: COUNTS/ML
SIZE RANGE RUN1 RUN2 RUN 3 SIZE RUN1 RUN2 RUN 3 SMPL AVG SIZE RUN1 RUN2 RUN 3 SMPL AV G
6-14um(c): 200060 199190 198660 4um(c): 5467 5445 5425 5446.0 4um(c): 5467 5445 5425 5446.0
14-21um(c): 11160 10730 11280 6um(c): 2121 2121 2124 2126.7 6um(c): 2134 2121 2124 2126.7
21-38um(c): 2120 2160 2330 14um(c): 133 129 138 133.6 14um(c): 133 129 138 133.6
38-70um(c): 70 40 150 21um(c): 22 22 25 23.1
+100um(c): 10 0 40 38um(c): 0 0 1 1.0
70um(c): 0 0 0 0.2 ISO: 20/18/14
Ordering Information
Part # Description
WOM.9100 H2Oil Water-in-Oil Monitor
B.91.701 Spare printer paper (5 rolls/bx)
S.840134 Oil delivery unit
ISO 11171 is the new particle counter calibra- ACTFD size NIST size
tion method and utilizes calibration fluid made (per ISO 4402:1991) (per ISO 11171:1999)
µm µm (c)
from ISO Medium Test Dust (ISO MTD) sus-
1 4.2
pended in MIL-H-5606. The calibration fluid is
2 4.6
traceable to the National Institute of Standards
3 5.1
and Technology (NIST) and is designated by 5 6.4
NIST as Standard Reference Material (SRM) 7 7.7
2806. ISO 11171 is replacing ISO 4402 which is 10 9.8
based on obsolete AC Fine Test Dust (ACFTD). 15 13.6
20 17.5
It is important to note that the ISO 11171 25 21.2
calibration method is based on a distribution 30 24.9
of particles measured by their equivalent area 40 31.7
diameter, whereas ISO 4402 is based on a
distribution of particles measured by their
longest chord. Also, the NIST work utilized
scanning electron microscopy for particles
below 10 µm in size, whereas the sizing
distribution on ACFTD utilized optical
microscopy.
The charts to the right show the approximate
particle size relationship between the
calibration methods.
Offer of Sale
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors.
This offer and its acceptance are governed by the provisions stated in the "Offer of Sale".