Sunteți pe pagina 1din 12

Cat Electronic Technician 2014A v1.

0
Product Status Report

6/7/2020 3:09 PM

Product Status Report


Parameter Value
Product ID KGB00296
Equipment ID KGB00296
Comments

Monitor
Parameter Value
ECM Serial Number 05ZJ0376AJ
Personality Module Part Number 2909514-12

C18 385C/390D (RHX02724)


Parameter Value
Equipment ID KGB00296
Engine Serial Number RHX02724
ECM Part Number 4787933-01
ECM Serial Number 11486628JM
Personality Module Part Number 4164662-00
Personality Module Release Date APR12
Personality Module Description HEX-385C-TNM

Logged Diagnostic Codes [Diagnostic Clock = 4278.4018 hours] - C18 385C/390D (RHX02724)
Code Description Occ. First Last
261-11 Engine Timing Offset fault 127 0 4275
110- 3 Engine Coolant Temperature Sensor : Voltage 112 3689 4270
Above Normal

Logged Event Codes [Diagnostic Clock = 4278.4018 hours] - C18 385C/390D (RHX02724)
Code Description Occ. First Last
E096 (1) High Fuel Pressure 90 4260 4278

Active Diagnostic Codes - C18 385C/390D (RHX02724)


Code Description
261-11 Engine Timing Offset fault

Active Event Codes - C18 385C/390D (RHX02724)


Code Description
No Active
Events
Current Totals - C18 385C/390D (RHX02724)
Description Value Unit
Engine Lifetime Hours Unavailable hours
Total Operating Hours 4278 hours
Total Fuel 43014 gal
Engine Starts 2413
Lifetime Total Engine 416194684 rev
Revolutions
Total Idle Time 923:42 hours
Total Idle Fuel 1702 gal
Total Max Fuel 114760 gal
Average Load Factor 36 %
Overall Load Factor 37 %

Configuration - C18 385C/390D (RHX02724)


Description Value Unit
Equipment ID KGB00296
Engine Serial Number RHX02724
ECM Part Number 4787933-01
ECM Serial Number 11486628JM
Personality Module Part Number 4164662-00
Personality Module Release Date APR12
Personality Module Description HEX-385C-TNM
Rated Power 553 hp at 1800 rpm
Rated Peak Torque 1934 lb-ft at 1400 rpm
Test Spec 0K4674
Top Engine Speed Range 1980 - 1980 rpm
Ether Solenoid Configuration Continuous Flow Solenoid
FLS -40
FTS 44
Total Tattletale 8

Injector Trim Calibration - C18 385C/390D (RHX02724)


Injector Serial Number File Version
Injector1 000000005A5079203834 0
Injector2 000000005A507920546E 0
Injector3 000000005A507920447B 0
Injector4 000000005A5079206243 0
Injector5 000000005A5079204772 0
Injector6 000000005A5079205072 0

Machine Control 385C


Parameter Value
Product ID KGB00296
ECM Part Number 1512106-03
ECM Serial Number 0596B030GV
Software Group Part Number 3567676-00
Software Group Description 385C HEX CONTROL
Software Group Release Date MAR10
Active Event Codes Present Unavailable

Logged Diagnostic Codes [Diagnostic Clock = 32408 hours] - Machine Control 385C
Code Description Occ. First Last
790- 4 Swing Pump (Outlet) Pressure Sensor : Voltage 255 32033 32408
Below Normal
96- 4 Fuel Level Sensor : Voltage Below Normal 255 32035 32406
190- 8 Engine Speed Sensor : Abnormal Frequency, 255 28961 32406
Pulse Width, or Period
590-12 Engine Control Module : Failure 255 28961 32405
190-10 Engine Speed Sensor : Abnormal Rate of Change 40 29017 32388
295-12 Large Hydraulic Excavator Control Module : 4 29692 32117
Failure
1150- 5 Swing Pump Swash Plate Angle Solenoid : 255 29458 32117
Current Below Normal
1155- 6 Front Pump Power Shift Pressure Solenoid : 197 29058 32112
Current Above Normal
1155- 3 Front Pump Power Shift Pressure Solenoid : 13 30814 32105
Voltage Above Normal
864- 3 Variable Implement Pump Oil Pressure Sensor : 255 28971 32031
Voltage Above Normal
1192- 7 Main Implement Valve : Not Responding Properly 32 28971 32009
1160- 5 Hydraulic Lock Solenoid : Current Below Normal 8 30812 31471
590- 9 Engine Control Module : Abnormal Update Rate 40 30786 30847
790- 3 Swing Pump (Outlet) Pressure Sensor : Voltage 115 30786 30804
Above Normal
586- 5 Engine Speed Dial Switch : Current Below Normal 255 30436 30803
588- 9 Monitor System Display : Abnormal Update Rate 30 30786 30803
864- 4 Variable Implement Pump Oil Pressure Sensor : 3 30786 30803
Voltage Below Normal
1139- 5 Stick Cylinder Extend Solenoid : Current Below 5 29691 29807
Normal
1163- 5 Left Travel Backward Solenoid : Current Below 4 29691 29807
Normal
1166- 5 Left Travel Forward Solenoid : Current Below 3 29691 29807
Normal
1140- 5 Stick Cylinder Retract Solenoid : Current Below 2 29691 29691
Normal
1150- 6 Swing Pump Swash Plate Angle Solenoid : 255 28962 29463
Current Above Normal
1121- 5 Front System High Pressure Solenoid : Current 8 28991 29001
Below Normal
600- 4 Hydraulic Oil Temperature Sensor : Voltage Below 4 28972 28972
Normal

Logged Event Codes [Diagnostic Clock = 32408 hours] - Machine Control 385C
Code Description Occ. First Last
E096 (2) High Fuel Pressure 255 28997 32407
E236 (2) Return Hydraulic Oil Filter Plugged 5 32405 32407
Active Diagnostic Codes - Machine Control 385C
Code Description
590-12 Engine Control Module : Failure
790- 4 Swing Pump (Outlet) Pressure Sensor : Voltage Below Normal

Current Totals - Machine Control 385C


Description Value Unit
Total Operating Hours 32408 hours
Engine Maintenance Hours 13964 hours
Engine Oil Hours 13964 hours
Engine Oil Filter Hours 13964 hours
Engine Coolant Hours 13964 hours
Fuel/ Water Separator Hours 13964 hours
Fuel Filter Hours 13964 hours
Secondary Fuel Filter Hours 0 hours
Hydraulic Pump Hours 13964 hours
Hydraulic Pilot Oil Filter Hours 13964 hours
Hydraulic Case Drain Oil Filter 13964 hours
Hours
Return Hydraulic Oil Filter 13964 hours
Hours
Hydraulic Oil Hours 13964 hours
Attachment Hydraulic Oil Filter 0 hours
Hours
Final Drive Oil Hours 13964 hours
Swing Drive Oil Hours 13964 hours
Swing Motor Hours 4623 hours
Travel Motor Hours 3593 hours
Tool #1 Hours 0 hours
Tool #2 Hours 0 hours
Tool #3 Hours 0 hours
Tool #4 Hours 0 hours
Return Hydraulic Oil Filter 16467.2 hours
Bypass Hours
Return Hydraulic Oil Filter 947.6 hours
Bypass at Cold Temperature
Hours
Hours of Operation at High 1430.5 hours
Hydraulic Pressure
Hours of Operation at Relief 346.0 hours
Hydraulic Pressure
HIC Pump Operating Hours 32408 hours
Diagnostic Clock 32408 hours

Configuration - Machine Control 385C


Description Value Unit
Product ID KGB00296
Straight Travel Pedal Installation Status Not Installed
Travel Alarm Installation Status Not Installed
Boom Check Valve Configuration Anti-Drift Valve
Stick Check Valve Configuration Anti-Drift Valve
Engine Cooling Fan Map Standard
Top Engine Fan Speed 900 rpm
Hydraulic Oil Type Mineral Oil
High Power Auxiliary Circuit Flow Rate 705 gal/min
Auto Lube System Installation Status Not Installed
Auto Lube Duration 480 sec
Auto Lube Interval 52 min
Machine Overload Pressure Sensor Not Installed
Installation
Machine Overload Pressure Threshold 4351 psi
Engine Fan Reversing Feature Installation Not Installed
Status
Water Separator Level Switch Normally Open
Configuration
Fuel Filter Differential Pressure Switch Normally Open
Config
Secondary Fuel Filter Differential Pressure Not Installed
Switch Config
Attachment Hydraulic Oil Filter Switch Not Installed
Configuration
Engine Fan Reverse Operation Time 300 sec
Security System Immobilizer Installation Not Installed
Status
Bucket Configuration Excavation
Excavator Operating Mode Ultra High Demolition
Auxiliary Pedal Installation Status Not Installed
Medium Pressure Hydraulic Circuit Not Installed
Configuration
Auxiliary Hydraulic Circuit #1 Configuration One or Two Way
Joystick Handle Configuration Modulation Handle
Joystick Input #1 Configuration Not Installed
Joystick Input #2 Configuration Not Installed
Joystick Input #3 Configuration Not Installed
Joystick Input #4 Configuration Not Installed
Left Joystick Switch #1 Installation Status Installed
Left Joystick Switch #2 Installation Status Installed
Right Joystick Switch #1 Installation Status Installed
Right Joystick Switch #2 Installation Status Installed
Left Joystick Thumbwheel Installation Not Installed
Status
Right Joystick Thumbwheel Installation Installed
Status
Auxiliary Flow Reduction Mode Enable Disabled
Status
Joystick Mapping Group Selection Disabled
Joystick Mapping Configuration SAE Mapping
Throttle Dial Position 1 Engine Speed 868 rpm
Throttle Dial Position 2 Engine Speed 1020 rpm
Throttle Dial Position 3 Engine Speed 1160 rpm
Throttle Dial Position 4 Engine Speed 1300 rpm
Throttle Dial Position 5 Engine Speed 1470 rpm
Throttle Dial Position 6 Engine Speed 1590 rpm
Throttle Dial Position 7 Engine Speed 1700 rpm
Throttle Dial Position 8 Engine Speed 1800 rpm
Throttle Dial Position 9 Engine Speed 1900 rpm
Throttle Dial Position 10 Engine Speed 1954 rpm
One Touch Engine Speed Setting 1100 rpm
AESC Setting 1300 rpm
AESC Delay Time 3.0 sec
Throttle Dial Position 1 Hydraulic System 53.0 %
Torque Percentage
Throttle Dial Position 2 Hydraulic System 60.0 %
Torque Percentage
Throttle Dial Position 3 Hydraulic System 68.0 %
Torque Percentage
Throttle Dial Position 4 Hydraulic System 75.0 %
Torque Percentage
Throttle Dial Position 5 Hydraulic System 80.0 %
Torque Percentage
Throttle Dial Position 6 Hydraulic System 83.0 %
Torque Percentage
Throttle Dial Position 7 Hydraulic System 86.0 %
Torque Percentage
Throttle Dial Position 8 Hydraulic System 89.0 %
Torque Percentage
Throttle Dial Position 9 Hydraulic System 92.0 %
Torque Percentage
Throttle Dial Position 10 Hydraulic System 92.0 %
Torque Percentage
Engine Oil Recommended Maintenance 0 hours
Interval
Engine Oil Filter Recommended 0 hours
Maintenance Interval
Engine Coolant Recommended 0 hours
Maintenance Interval
Fuel/ Water Separator Recommended 0 hours
Maint Interval
Fuel Filter Recommended Maintenance 0 hours
Interval
Hydraulic Pilot Oil Filter Recommended 0 hours
Maintenance Interval
Hydraulic Case Drain Oil Filter 0 hours
Recommended MI
Return Hyd Oil Filter Recommended Maint 0 hours
Interval
Final Drive Oil Recommended 0 hours
Maintenance Interval
Hydraulic Oil Recommended Maintenance 0 hours
Interval
Swing Drive Oil Recommended 0 hours
Maintenance Interval
Attachment Hydraulic Oil Filter 0 hours
Recommended Maintenance Interval
Secondary Fuel Filter Recommended 0 hours
Maintenance Interval
Soft Mode Gain Selection Gain Index 1
Soft Mode Response Selection Slow
Normal Mode Gain Selection Gain Index 4
Normal Mode Response Selection Fast
Quick Mode Gain Selection Gain Index 5
Quick Mode Response Selection Fast

Tool Configuration - Machine Control 385C


Description Value Unit
Tool Program Name hammer1 Active
Description Selected Tool 1
Program Index Number
Maximum Throttle Dial 10
Auxiliary Valve Mode One Way
Aux Valve Max Extend Flow 85 gal/min
Aux Valve Extend Open Rate 255
Aux Valve Extend Close Rate 255
Aux Valve Max Retract Flow Unavailable Parameter gal/min
Aux Valve Retract Open Rate Unavailable Parameter
Aux Valve Retract Close Rate Unavailable Parameter
Auxiliary Minimum Hydraulic 85 gal/min
Extend Flow
Auxiliary Hydraulic Extend Flow 0 psi
Reduction Pressure
Auxiliary Hydraulic Extend 3046 psi
Relief Pressure
Auxiliary Minimum Hydraulic 0 gal/min
Retract Flow
Auxiliary Hydraulic Retract Flow 0 psi
Reduction Pressure
Auxiliary Hydraulic Retract 0 psi
Relief Pressure
Med Press Ckt #1-A Max Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-A Min Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-A Open Rate Unavailable Parameter
Med Press Ckt #1-A Close Rate Unavailable Parameter
Med Press Ckt #1-B Max Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-B Min Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-B Open Rate Unavailable Parameter
Med Press Ckt #1-B Close Rate Unavailable Parameter
Initial Tool Program Medium 3 %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium 10 %
Pressure Circuit Main Pump
Torque Reduction
Bucket Lever Control Mode Bucket Valve - Direct
Proportional Control
Attachment Pedal Valve Mode Unavailable Parameter
Joystick #1 Valve Mode Unavailable Parameter
Joystick #4 Valve Mode Unavailable Parameter
Left Joystick Thumbwheel Unavailable Parameter
Control Mode
Right Joystick Thumbwheel Aux Valve - Normal Modulation
Control Mode
Joystick #1 Switch Valve Mode Unavailable Parameter
Joystick #2 Switch Valve Mode Unavailable Parameter
Joystick #3 Switch Valve Mode Unavailable Parameter
Joystick #4 Switch Valve Mode Unavailable Parameter
Rocker Switch Valve Mode No valve controlled
Left Joystick Switch #1 Control No valve controlled
Mode
Left Joystick Switch #2 Control No valve controlled
Mode
Right Joystick Switch #1 Auxiliary Valve #1 Extend -
Control Mode Switched Control
Right Joystick Switch #2 No valve controlled
Control Mode

Tool Configuration - Machine Control 385C


Description Value Unit
Tool Program Name hammer2
Description Selected Tool 2
Program Index Number
Maximum Throttle Dial 10
Auxiliary Valve Mode One Way
Aux Valve Max Extend Flow 85 gal/min
Aux Valve Extend Open Rate 255
Aux Valve Extend Close Rate 255
Aux Valve Max Retract Flow Unavailable Parameter gal/min
Aux Valve Retract Open Rate Unavailable Parameter
Aux Valve Retract Close Rate Unavailable Parameter
Auxiliary Minimum Hydraulic 85 gal/min
Extend Flow
Auxiliary Hydraulic Extend Flow 0 psi
Reduction Pressure
Auxiliary Hydraulic Extend 3046 psi
Relief Pressure
Auxiliary Minimum Hydraulic 0 gal/min
Retract Flow
Auxiliary Hydraulic Retract Flow 0 psi
Reduction Pressure
Auxiliary Hydraulic Retract 0 psi
Relief Pressure
Med Press Ckt #1-A Max Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-A Min Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-A Open Rate Unavailable Parameter
Med Press Ckt #1-A Close Rate Unavailable Parameter
Med Press Ckt #1-B Max Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-B Min Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-B Open Rate Unavailable Parameter
Med Press Ckt #1-B Close Rate Unavailable Parameter
Initial Tool Program Medium 3 %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium 10 %
Pressure Circuit Main Pump
Torque Reduction
Bucket Lever Control Mode Bucket Valve - Direct
Proportional Control
Attachment Pedal Valve Mode Unavailable Parameter
Joystick #1 Valve Mode Unavailable Parameter
Joystick #4 Valve Mode Unavailable Parameter
Left Joystick Thumbwheel Unavailable Parameter
Control Mode
Right Joystick Thumbwheel Aux Valve - Normal Modulation
Control Mode
Joystick #1 Switch Valve Mode Unavailable Parameter
Joystick #2 Switch Valve Mode Unavailable Parameter
Joystick #3 Switch Valve Mode Unavailable Parameter
Joystick #4 Switch Valve Mode Unavailable Parameter
Rocker Switch Valve Mode No valve controlled
Left Joystick Switch #1 Control No valve controlled
Mode
Left Joystick Switch #2 Control No valve controlled
Mode
Right Joystick Switch #1 Auxiliary Valve #1 Extend -
Control Mode Switched Control
Right Joystick Switch #2 No valve controlled
Control Mode

Tool Configuration - Machine Control 385C


Description Value Unit
Tool Program Name shears1
Description Selected Tool 3
Program Index Number
Maximum Throttle Dial 10
Auxiliary Valve Mode Two Way
Aux Valve Max Extend Flow 106 gal/min
Aux Valve Extend Open Rate 255
Aux Valve Extend Close Rate 255
Aux Valve Max Retract Flow 106 gal/min
Aux Valve Retract Open Rate 255
Aux Valve Retract Close Rate 255
Auxiliary Minimum Hydraulic 106 gal/min
Extend Flow
Auxiliary Hydraulic Extend Flow 0 psi
Reduction Pressure
Auxiliary Hydraulic Extend 5802 psi
Relief Pressure
Auxiliary Minimum Hydraulic 106 gal/min
Retract Flow
Auxiliary Hydraulic Retract Flow 0 psi
Reduction Pressure
Auxiliary Hydraulic Retract 5802 psi
Relief Pressure
Med Press Ckt #1-A Max Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-A Min Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-A Open Rate Unavailable Parameter
Med Press Ckt #1-A Close Rate Unavailable Parameter
Med Press Ckt #1-B Max Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-B Min Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-B Open Rate Unavailable Parameter
Med Press Ckt #1-B Close Rate Unavailable Parameter
Initial Tool Program Medium 3 %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium 10 %
Pressure Circuit Main Pump
Torque Reduction
Bucket Lever Control Mode Bucket Valve - Direct
Proportional Control
Attachment Pedal Valve Mode Unavailable Parameter
Joystick #1 Valve Mode Unavailable Parameter
Joystick #4 Valve Mode Unavailable Parameter
Left Joystick Thumbwheel Unavailable Parameter
Control Mode
Right Joystick Thumbwheel Aux Valve - Normal Modulation
Control Mode
Joystick #1 Switch Valve Mode Unavailable Parameter
Joystick #2 Switch Valve Mode Unavailable Parameter
Joystick #3 Switch Valve Mode Unavailable Parameter
Joystick #4 Switch Valve Mode Unavailable Parameter
Rocker Switch Valve Mode No valve controlled
Left Joystick Switch #1 Control No valve controlled
Mode
Left Joystick Switch #2 Control No valve controlled
Mode
Right Joystick Switch #1 No valve controlled
Control Mode
Right Joystick Switch #2 No valve controlled
Control Mode

Tool Configuration - Machine Control 385C


Description Value Unit
Tool Program Name shears2
Description Selected Tool 4
Program Index Number
Maximum Throttle Dial 10
Auxiliary Valve Mode Two Way
Aux Valve Max Extend Flow 106 gal/min
Aux Valve Extend Open Rate 255
Aux Valve Extend Close Rate 255
Aux Valve Max Retract Flow 106 gal/min
Aux Valve Retract Open Rate 255
Aux Valve Retract Close Rate 255
Auxiliary Minimum Hydraulic 106 gal/min
Extend Flow
Auxiliary Hydraulic Extend Flow 0 psi
Reduction Pressure
Auxiliary Hydraulic Extend 5802 psi
Relief Pressure
Auxiliary Minimum Hydraulic 106 gal/min
Retract Flow
Auxiliary Hydraulic Retract Flow 0 psi
Reduction Pressure
Auxiliary Hydraulic Retract 5802 psi
Relief Pressure
Med Press Ckt #1-A Max Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-A Min Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-A Open Rate Unavailable Parameter
Med Press Ckt #1-A Close Rate Unavailable Parameter
Med Press Ckt #1-B Max Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-B Min Sol Unavailable Parameter Amps
Current
Med Press Ckt #1-B Open Rate Unavailable Parameter
Med Press Ckt #1-B Close Rate Unavailable Parameter
Initial Tool Program Medium 3 %
Pressure Circuit Main Pump
Torque Reduction
Total Tool Program Medium 10 %
Pressure Circuit Main Pump
Torque Reduction
Bucket Lever Control Mode Bucket Valve - Direct
Proportional Control
Attachment Pedal Valve Mode Unavailable Parameter
Joystick #1 Valve Mode Unavailable Parameter
Joystick #4 Valve Mode Unavailable Parameter
Left Joystick Thumbwheel Unavailable Parameter
Control Mode
Right Joystick Thumbwheel Aux Valve - Normal Modulation
Control Mode
Joystick #1 Switch Valve Mode Unavailable Parameter
Joystick #2 Switch Valve Mode Unavailable Parameter
Joystick #3 Switch Valve Mode Unavailable Parameter
Joystick #4 Switch Valve Mode Unavailable Parameter
Rocker Switch Valve Mode No valve controlled
Left Joystick Switch #1 Control No valve controlled
Mode
Left Joystick Switch #2 Control No valve controlled
Mode
Right Joystick Switch #1 Auxiliary Valve #1 Extend -
Control Mode Switched Control
Right Joystick Switch #2 No valve controlled
Control Mode