GROUP 5 TRAVEL SPEED CONTROL SYSTEM

Travel motor

Main control valve

Extra C

Extra B Bucket
(Dozer) Regulator Regulator
Extra A &
Arm 1
Arm regen
Boom 2 Arm 2
S/Priority

Swing Boom 1

Travel(LH) Travel(RH)

Straight
Travel

Travel spped
solenoid valve

Engine

Main pump Pilot pump

Max flow
CO valve

EPPR valve

Travel speed switch signal Drive signal


CPU controller

1607A5MS07

Travel speed can be switched manually by pressing the travel speed switch on the cluster.
Travel speed Lamp
Speed Operation
solenoid valve on cluster
Lo OFF Turtle Low speed, high driving torque in the travel motor
Hi ON Rabbit High speed, low driving torque in the travel motor
ö Default : Turtle(Lo)