GENERAL NOTES:-

1. ALL DIMENSIONS ARE IN MILLIMETERS AND ALL LEVELS ARE IN METERS UNLESS OTHERWISE

COLUMN SCHEDULE STATED.


2. MISSING OR AMBIGUOUS DIMENSIONS IN ANY DRAWING ARE TO BE CLARIFIED FROM AUTHORITY
CONCERNED.
M30 : Fe500D , COVER = 40MM M30 : Fe500D , COVER = 40MM M30 : Fe500D , COVER = 40MM M30 : Fe500D , COVER = 40MM M30 : Fe500D , COVER = 40MM 3. DO NOT SCALE DRAWING ONLY WRITTEN DIMENSIONS TO BE FOLLOWED.
4. ALL STRUCTURAL DRAWINGS TO BE READ ALONG WITH ARCHITECTURAL DRAWINGS.
CONFINING ZONE : 1100MM CONFINING ZONE : 1100MM CONFINING ZONE : 1100MM CONFINING ZONE : 1100MM CONFINING ZONE : 1075MM
STRUCTURAL NOTES :-
1. DESIGN CRITERIA :-
NO. OF FLOORS BASEMENT+GROUND+11+4 FUTURE PROVISION+TERRACE
DEAD LOADS IS : 875(PART-1)
LIVE LOADS IS : 875(PART-2)
EARTHQUAKE LOADS IS : 1893-2016,IS:13920-2016 ,IS:16700-2017
(EQ. ZONE III, R=5, I=1.5)
EXPOSURE CONDITION : MODERATE
FIRST FLOOR LVL. 2. NOTES GIVEN UNDER THIS HEADING SHALL BE READ IN CONJUNCTION WITH GENERAL
NOTES AND TYPICAL DETAILS ALL STRUCTURAL DRAWINGS SHALL
BE REFERRED ALONG WITH ARCHITECTURAL DRAWINGS.
3. REINFORCEMENT ( STEEL ) SHALL BE THERMO MECHANICALLY TREATED (TMT) BAR
HAVING MINIMUM GRADE AS 500-D AND CONFORMING TO IS :1786 SHALL BE USED.
4. ANY MINOR OR MAJOR CHANGES ARE NOT ALLOWED WITHOUT WRITTEN PERMISSION
OF THIS OFFICE.
5. UNLESS OTHERWISE SPECIFIED ALL PCC SHALL BE OF M-15.
Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS UNLESS OTHERWISE SPECIFIED ALL RCC WORK SHALL BE M-30
To 6. SEE THE ARCHITECTURAL DRAWINGS FOR FOLLOWING :
A. SIZE AND LOCATION OF ALL DOOR AND WINDOW OPENINGS.
T10 @ 100 T10 @ 100 T8 @ 150 T10 @ 100 T10 @ 100 T8 @ 150 T10 @ 100 T10 @ 100 T8 @ 150 T10 @ 100 T10 @ 100 T8 @ 150 T10 @ 100 T10 @ 100 T8 @ 150 B. SIZE AND LOCATION OF ALL INTERIOR AND EXTERIOR NONBEARING PARTITIONS.
C. SIZE AND LOCATION OF FLOOR DRAINS, SLOPES, DEPRESSED AREAS ETC.
D. SIZE AND LOCATION OF ALL FLOOR AND ROOF CURBS.
E. FLOOR AND ROOF FINISHES.
SEVENTH FLOOR LVL. 7. IF ANY DISCREPANCY FOUND IN THE DRAWING IT SHALL BE BROUGHT TO THE NOTICE
OF CONSULTANTS/ENGINEERS BEFORE EXECUTION OF WORK.
8. LAP LENGTH FOR REINFORCEMENT SHALL BE 50 TIMES DIA OF BAR IF NOT SPECIFIED.
9. CLEAR COVER FOR REINFORCEMENT :-
FOLLOWING CLEAR COVERS SHALL BE PROVIDED TO THE MAIN REINFORCEMENT
600 600 600 600 500 IN THE CORRESPONDING STRUCTURAL MEMBERS.
RAFT …. BOTTOM …. 60 MM
T20
T25 T25 T25 TOP …. 50 MM
T16 FOOTINGS BOTTOM …. 60 MM
T20 T20 T20 T20 TOP …. 50 MM
R.C.C.COLUMNS …. 40 MM
1000 RETAINING WALL SOIL SIDE …. 40 MM
1100 1100 1100 1100
INSIDE FACE …. 30 MM
BEAMS …. 30 MM
SLABS …. 25 MM
30-T20 4-T25 + 26-T20 4-T25 + 26-T20 14-T25 + 16-T20 12-T20+14-T16 10. FOUNDATION IS DESIGNED FOR SBC OF 50 T/M2 @ 8.0 M.DEPTH FROM NGL. AS PER
NKPC SOIL REPORT NO (2019 88 01) DATED JAN-2019 SUPPLIED BY EE, PIU-RAJKOT
C1A C1B C1C C1D C2A
ZONE-1, RAJKOT LETTER NO. PIU/RJT/DEE/100/7 DATED - 08-01-2020.
A-C15,A-C28, A-C19,A-C29, A-C30,B-C32 A-C31,A-C32 A-C8,A-C9,A-C10,A-C11,A-C34, 11. THE BUILDING IS DESIGNED AS PER ARCHITECT DRAWING NOS -569 - MCH - E - A - 1100
COLUMN MARKED A-C35,B-C1,B-C7,B-C9 TO --------------- DATED 10.12.2019 SUPPLIED VIDE PIU LETTE................
B-C42,B-C47,B-C48,B-C53 B-C17,B-C43,B-C45,B-C51 12. ORIENTATION OF COLUMN SHALL BE STRICTLY FOLLOWED AS SHOWN IN THE PLAN.
13. IN COLUMNS NOT MORE THAN 50 % BARS SHALL BE SPLICED AT A SECTION.
14. ALL COLUMNS REINFORCEMENTS SHALL BE WITH STAGGERED LAP JOINT.
15. STRIPPING TIME OF FORM WORK FOR RCC- AS DECIDED BY SITE ENGINEER IN
M30 : Fe500D , COVER = 40MM M30 : Fe500D , COVER = 40MM M30 : Fe500D , COVER = 40MM M30 : Fe500D , COVER = 40MM M30 : Fe500D , COVER = 40MM ACCORDANCE WITH IS-456/2000.
CONFINING ZONE : 1075MM CONFINING ZONE : 1200MM CONFINING ZONE : 1200MM CONFINING ZONE : 1300MM CONFINING ZONE : 1300MM 16. CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ALL EXECUTION WORK AT SITE.
17. THE REQUIREMENT OF SOIL RETENTION SHALL BE DECIDED BASED ON SITE CONDITION
BY CONTRACTOR IN CONSULTATION WITH ENGINEER IN -CHARGE.
18. HEAVY AND LOCALIZED MATERIAL STORAGE SHALL BE PROHIBITED ON FLOOR LEVELS.
19. EXTRA STEEL AROUND CUTOUTS SHALL BE PROVIDED AS PER DETAIL.
20. ALL PARTITION WALLS SHALL BE LIGHT WEIGHT AAC (AUTOCLAVED AERATED
CONCRETE) BLOCKS WITH DENSITY NOT GREATER THAN 10KN/M³.
21. ALL FILLING SHALL BE DONE WITH LIGHT WEIGHT AAC BLOCKS.

FIRST FLOOR LVL.


569 - MCH - E - S - 2000
*. THE STRUCTURAL DESIGN PHILOSOPHY AND THE DRAWING (DRW,NO.______________________
01-06-2020
DT:-_______________) HAVE BEEN SCRUTINIZED BY THIS OFFICE AND ARE GENERALLY
FOUND ACCEPTABLE SUBJECT TO COMPLIANCE AND OBSERVATIONS CONTAINED IN THIS
OFFICE LETTER NO:- PIU/RJT/DEE/70/20
_________________ DT:-______________WHICH
04/06/2020 MAY BE APPROVED BY THE
CONCERNED "COMPETENT AUTHORITY"

*. THE STRUCTURAL CONSULTANT & CONTRACTOR SHALL BE RESPONSIBLE FOR THE


Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS CORRECTNESS OF DESIGN & SOUNDNESS, DURABILITY & STRENGTH OF THE STRUCTURE.
To *. THE DRAWING AND THE DESIGN CALCULATION OF THE PROJECT SHALL BE THE PROPERTY
T10 @ 100 T10 @ 100 T8 @ 150 T10 @ 100 T10 @ 100 T8 @ 150 T10 @ 100 T10 @ 100 T8 @ 150 T10 @ 100 T10 @ 100 T8 @ 150 T10 @ 100 T10 @ 100 T8 @ 150 OF THE ROAD AND BUILDING DEPARTMENT.GOVT. OF GUJARAT. THE DRAWING AND DESIGN
SHALL NOT BE USED IN ANY WAY WITHOUT THE PRIOR PERMISSION OF GOVERNMENT OF
GUJARAT.

SEVENTH FLOOR LVL.


400
700 700 700 700 ASSISTANT ENGINEER DY. EXECUTIVE ENGINEER
T20
1000 T25 T25
T20 T20 T20 T20 CHEIF ENGINEER & DIRECTOR
STAFF TRAINING COLLEGE ,GANDHINAGAR
24-T20 1200 1200 1300 1300
EXECUTIVE ENGINEER

C3A
DESIGNS (R&B) CIRCLE - GANDHINAGAR

A-C39,A-C40,A-C42, THIS IS TO CERTIFY THAT

B-C77,B-C79,B-C80,B-C81, 34-T20 4-T25 + 30-T20 36-T20 32-T25+4-T20 1. EACH AND EVERY DESIGN CALCULATION OF THIS DRAWING AND CONCERN DRAWINGS
C4C
C5A C5B ARE CHECKED AND VERIFIED BY US.
B-C83,B-C84,B-C85,B-C86,B-C87, A-C16,A-C17,A-C20,A-C34 A-C21,A-C22 B-C10,B-C12,B-C13,B-C14,B-C15, B-C11,B-C22,B-C23 2. DESIGN AND DRAWING IS DEVELOPED IN CONFORMITY WITH SCOPE OF WORK
COLUMN MARKED B-C89,B-C91,B-C92,B-C93 B-C16,B-C24,B-C25,B-C26,B-C37,B-C38
NARRATED IN TENDER AND SATISFIED ALL REQUIREMENT OF LATEST CODAL PROVISION.
B-C35,B-C36,B-C39,B-C40 3. DESIGN AND DRAWING IS CHECKED AND APPROVED BY THIS OFFICE HERE WITH AND
CORRECT, SOUND AND ADEQUATE TO ADOPT FOR EXECUTION. THIS OFFICE WILL BE
RESPONSIBLE FOR THE SAME.

M30 : Fe500D , COVER = 40MM M30 : Fe500D , COVER = 40MM M30 : Fe500D , COVER = 40MM M30 : Fe500D , COVER = 40MM M30 : Fe500D , COVER = 40MM
CONFINING ZONE : 1100MM CONFINING ZONE : 1075MM CONFINING ZONE : 1075MM CONFINING ZONE : 1150MM CONFINING ZONE : 1150MM

PROJECT IMPLEMENTATION UNIT ZONE - 1 , RAJKOT

GOOD FOR CONSTRUCTION

FIRST FLOOR LVL.


16-06-2020 R1 REVISION AS PER COMMENTS RECEIVED FROM R&B ON 11/06/2020

DATE REVISIONS PARTICULARS

DRG. NO. : - 569 - MCH - E - S - 2000-a SHEET - 1 OF 4

Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS Z1 MAIN LINK Z1 OTHERS Z2 LINKS SCELE PROJECT : -
MCH BLOCK AT ZANANA CIVIL
To
T10 @ 100 T10 @ 100 T8 @ 150 T10 @ 100 T10 @ 100 T8 @ 150 T10 @ 100 T10 @ 100 T8 @ 150 T10 @ 100 T10 @ 100 T8 @ 150 T10 @ 100 T10 @ 100 T8 @ 150 1:200 HOSPITAL CAMPUS AT RAJKOT

SIZE
MCH BLOCK
A1
SEVENTH FLOOR LVL. NORTH TITLE :-
COLUMN AND SHEAR WALL DETAIL
FIRST FLOOR LVL. To SEVENTH FLOOR LVL.
400 600 600 DATE : -01-06-2020 DRAWN BY :- BHANA CHKD BY :- N.R.
500 500
T20
T16 T25 T25 T25
T20 T20 T20 T20
1100 T16
1000 1000 1150 1150
NISHANT RATHI AR. AJAY SHUKLA

22-T20+4-T16 20-T20+8-T16 4-T25 + 24-T20 6-T25 + 22-T20 24-T25 + 4-T20


C6A C6B C8C

A-C2,A-C4,A-C6,A-C7,A-C12,A-C14,
B-C66,B-C69,B-C72,B-C74,B-C71 B-C65,B-C75 B-C6,B-C8,B-C46,B-C49,B-C50 B-C4,B-C5,B-C21,B-C27 SOURABH KOCHAT J.J. MEHTA
COLUMN MARKED A-C27,A-C36,A-C37,A-C38,
B-C68 B-C58,B-C60,B-C61,B-C62,B-C64 B-C3 CONSULTING ARCHITECTS & ENGINEERS

AKA CONSULTANTS (INDIA) PVT. LTD.


(AN ISO 9001-2008 COMPANY)
8, STATE BANK OFFICER'S COLONY
BEEMA NAGAR, OPP. ANAND BAZAAR INDORE- 452001 (M.P.)
PH.:0731-2565304,2561685 FAX:0731-2565477
e-mail : akakem@gmail.com