4 Cooling circuit
The cooling circuit comprises inverter, drive motor, generator, cooling pump and
radiator.
Type of coolant: Water/Glycol 50/50
It has to be ensured that the selected coolant is corrosion-inhibiting and non-aggressive
to aluminium. The specification is based on a coolant-fluid of water/glycol, the minimum
volume ratio of water being 50%.
The cooling performance of the pump and the radiator must satisfy following key data:
Coolant flow rate (rated condition):
DUO-Inverter: 40 l/min
Motor: 1PV5131 8 l/min to 20 l/min
Motor: 1PV5135 20 l/min
Motor: 1PV5138 20 l/min
Generator: 1FV5139 20 l/min
Heat loss at rated power (Ploss):
DUO-Inverter: 5.0 kW
Motor: 1PV5131 ≈ 0.2 kW * Pmech
Motor: 1PV5135 6.0 kW
Motor: 1PV5138 8.0 kW
Generator: 1FV5139 6.0 kW
Max. coolant temperature at inlets for rated power output:
DUO-Inverter: 50 °C
Motor/Generator: 55 °C
Pressure drop motor/generator: (+ 50 °C, 60/40 water/glycol)
DUO-Inverter: ca. 150 mbar
Motor: 1PV5131 ca. 70 mbar @ 8 l/min
Motor: 1PV5135 ca. 300 mbar
Motor: 1PV5138 ca. 300 mbar
Generator: 1FV5139 ca. 300 mbar
Temperature difference at rated conditions:
DUO-Inverter: ca. 2.5 K
Motor: 1PV5131 ≈ 0.7 K * Ploss
Motor: 1PV5135 ca. 4.0 K
Motor: 1PV5138 ca. 5.0 K
Generator: 1FV5139 ca. 3.5 K
Volume of Coolant:
DUO-Inverter: ca. 3 liter
Motor: 1PV5131 ca. 1.7 liter
Motor: 1PV5135 ca. 2.3 liter
Motor: 1PV5138 ca. 2.8 liter
Generator: 1FV5139 ca. 3.1 liter
Maximum pressure in the cooling system: 3 bar
All coolant connections are tube stems for connecting the coolant hoses directly. The
hoses are fixed using hose clamps. The rated diameter of the hoses to be chosen
5 Connections
5.1 Motor /Generator / Inverter
5.1.1 Power connections
5.1.1.1 Motor-/Generator power connections
Terminal box with inside thread for PG-threaded joints PG16/SW24 and bolts with a
rated diameter M6 at the terminal box. Terminals U1, V1, W1 are used to connect the
power cables L1, L2 and L3.