Sunteți pe pagina 1din 5

TCM-2 Thyristor Control Module

TCM-2 Thyristor
DATA
DATA Control
SHEETModule
SHEET
DATA SHEET

Electronic potentiometers, EPN-110DN


ANSI code 18

 Control of electronic governors


 Setting of integrating time
 Adjustment of output signal
 Offset adjustment
 LED indication for activated input
 35 mm DIN rail or base mounting

Document no.: 4921240126H


Data sheet EPN-110DN
Application The maximum and minimum change of the frequen-
The electronic potentiometer type EPN-110DN forms cy/voltage of the connected speed governor/AVR, con-
part of a complete DEIF series of relays for protection trolled by the EPN-110DN.
and control of generators, and is applicable to both
marine and land-based installations. The range (“x 1", “x 5" or ”x 10”) is selected by means
of 2 DIP switches accessible from the front of the relay.
The EPN-110DN is type-approved by major classifica-
tion societies and is an electronic unit to replace normal A special output 0...5...10V DC is available for interfac-
motor potentiometers. ing between a DEIF synchroniser type FAS-115DG and
a VAr load sharing unit type LSU-122DG, applied for
The potentiometer converts the relay output of a PI step voltage adaption to obtain simultaneous synchronisa-
controller - e.g. one of the DEIF load sharing units type tion of all generators of a plant to the busbar.
LSU.. or one of the DEIF synchronisers type FAS.., or
any other type of PI step controller provided with relay Integrating time
outputs - to a control voltage for the speed gover- Potentiometer “TIME” (2.5 s...25 s x 1 or x 10)
nor/AVR.
How quickly the output integrates from the minimum to
Measuring principle the maximum setting (or vice versa). This setting thus
determines how quickly e.g. a load sharing will be car-
The EPN-110DN is provided with 3 inputs:
ried out.
“▲” (frequency or voltage increase)
The range (“x 1" or “x 10") is selected by means of a
”▼” (frequency or voltage decrease)
DIP switch accessible from the front of the relay.
“RES” (reset of the unit).
Offset
Note: During power-up, the potentiometer is auto-
Potentiometer “OFFSET” (-25...0...25% of output)
matically reset.
The point where the control loop starts. This setting
On activation of one of the inputs “▲” and ” ▼”, the
determines e.g. to which frequency the generator
analogue output of the potentiometer to the speed gov-
should be reset instantaneously during power-up or on
ernor/the AVR is changed correspondingly.
activation of the reset input.
The EPN-110DN is furthermore provided with an offset
adjustment for change of the point where the control Principle diagram
loop starts and to which the unit returns after reset.
Both the output signal, the rate of change of this (the
integrating time) and the offset are set on potentiome-
ters on the front of the EPN-110DN.

Outputs/settings
The EPN-110DN is equipped with 2 LED indicators on
the front of the unit, which are lit when their input (“▲”
and “▼” respectively) has been activated.

To ensure that the EPN-110DN can be connected to all


common electronic speed governors and AVRs, the
analogue output of the EPN-110DN has been designed
as a current generator shunted by a 500 potentiome-
ter.

Output signal
Potentiometer “OUTPUT” (0...±1V DC x 1, x 5 or x 10)

DEIF A/S Page 2 of 5


Data sheet EPN-110DN
Technical specifications
Relay input: Potential-free relay contacts Supply voltage (Un): 57.7-63.5-100-110-127-200-220-
Open contact: 15V DC 230-240-380-400-415-440-450-
Closed contact: 4 mA 660-690V AC ±20% (max. 3.5 VA)

Analogue output: 0...±1V DC (DIP switches set to 24-48-110-220V DC -25/+30%


“x1") (max. 2 W)

or: UL/cUL listed:


0...±5V DC (DIP switches set to Only 24V DC and 110V AC
“x5") DC supply must be from a class 2
or: power source
0…±10V DC (DIP switches set to
”x10”) Climate: HSE, to DIN 40040

UL/cUL listed: +/-10V DC EMC: To EN 61000-6-1/2/3/4,


SS4361503 (PL4) and IEC 255-3
Output resistance: 0...500 potentiometer
Connections: Max. 4.0 mm² (single-stranded)
Offset adjustment: -25...0...25% of output Max. 2.5 mm² (multi-stranded)
Ripple: Max. 5mV RMS Materials: All plastic parts are self-
extinguishing to UL94 (V1)
Resolution: 5mV DC (12-bit D/A converter)
Protection: Case: IP40. Terminals: IP20,
Response time: <100 ms, input to output to IEC 529 and EN 60529
Temperature: -25...70°C (-13…158°F) (operating) Type approval: The Uni-line components are
UL/cUL listed: approved by the major classifica-
Max. surrounding air temp. tion societies. For current appro-
60˚C/140°F vals see www.deif.com or contact
DEIF A/S.
Temperature drift: Setpoints:
Max. ±0.2% of full scale per UL markings: Wiring:
10°C/50°F Use 60/75°C (140/167°F) copper
conductors only
Galv. separation: 3250 V - 50 Hz - 1 min.
Wire size:
Supply voltage to other circuits AWG 12-16 or equivalent
None between inputs and DC out- Installation:
put To be installed in accordance with
the NEC (US) or the CEC (Cana-
da)

DEIF A/S Page 3 of 5


Data sheet EPN-110DN
Settings
Setting of Range
Integrating time: 2.5 s...25 s or 25...250 s
-1...0...1V DC, -5...0...5V DC or
Output:
-10…0…10V DC
Offset: -25...0...25% of output

Indication
LED Light
“▲” (Increase)
Yellow, when relay is activated
“▼” (Decrease)

The relay is furthermore equipped with a green LED marked “POWER” for indication of power ON. Once the relay has
been mounted and adjusted, the transparent front cover may be sealed to prevent unwanted change of the setting.

Connections/dimensions (in mm)

Note: Terminal nos. 16, 18 and 20 are internally connected to each other.

Weight: Approx. 0.650 kg

DEIF A/S Page 4 of 5


Data sheet EPN-110DN
Available variants

Item no. Variant no. Variant description


2913110020 01 EPN-110DN - DC supply
2913110020 02 EPN-110DN - AC supply

Order specifications
Variants:

Additional options to the


Mandatory information standard variant
Item no. Type Variant no. Output Supply voltage Option

Example:

Additional options to the


Mandatory information standard variant
Item no. Type Variant no. Output Supply voltage Option
2913110020-01 EPN-110DN 01 -5...0...5V DC 24V DC No options available

Due to our continuous development we reserve the right


to supply equipment which may vary from the described.
DEIF A/S, Frisenborgvej 33
DK-7800 Skive, Denmark

Tel.: +45 9614 9614, Fax: +45 9614 9615


E-mail: deif@deif.com, URL: www.deif.com