Product Introduction
Quick Guide
This robust inverter is designed to power your home appliances or precious electronics. It also
can accept wide input voltage to generate stable and pure power source to power
downstream AC loads. Based on different types of loads, this inverter can provide pure and
stable power either to house appliances or to sensitive personal computers via selectable
operation modes. It is a brilliant choice for home owners or small office users in the unstable
power area.

2. Product Overview
Front View:

 Power Switch
600VA Inverter  Display indication (see the
Operation section for the details)

Back View:

AC input
Input breaker
External battery connector
Output receptacles

V. 1.1
3. Important Safety Warning (SAVE THESE INSTRUCTIONS) 4. Specifications
Personnel Precaution - MODEL 600
CAUTION! Careful to reduce the risk or dropping a metal tool on the batteries. It could spark CAPACITY 600 VA / 420 W
or short circuit the batteries and could cause an explosion. INPUT
CAUTION! Remove personal metal items such as rings, bracelets, necklaces, and watches Voltage 230 VAC
when working with batteries. Batteries can produce a short circuit current high enough to Voltage Range 100 – 300 VAC
make metal melt, and could cause severe burns. OUTPUT
CAUTION! Avoid touching eyes while working near batteries. Voltage Regulation (Batt. Mode) +/-10%
CAUTION! Have plenty of fresh water and soap nearby in case battery acid contacts skin, Transfer Time 20 ms Typical
clothing, or eyes. Waveform Simulated Sine Wave
CAUTION! NEVER smoke or allow a spark or flame in vicinity of a battery. BATTERY
CAUTION! If a remote or automatic generator start system is used, disable the automatic Battery Voltage 12 VDC
starting circuit or disconnect the generator to prevent accident during servicing. Number of Battery One
CAUTION! The unit is designed for indoor use. Do not expose this unit to rain, snow or liquids Floating Charge Voltage 13.7 VDC ± 2%
of any type. Maximum Charge Current 10 A
CAUTION! To reduce risk of injury, only use qualified batteries from qualified distributors or Recommended Battery Capacity 100 Ah – 200 Ah
manufacturers. Any unqualified batteries may cause damage and injury. Do NOT use old or PHYSICAL
Dimension (DxWxH) mm 359 x 97 x 147
overdue batteries. Please check the battery type and date code before installation to avoid
Net Weight (kgs) 5.1
damage and injury.
WARNING! It's very important for system safety and efficient operation to use appropriate 5. Installation
external battery cable. To reduce risk of injury, external battery cables should be UL certified NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is
and rated for 75° C or higher. And do not use copper cables less than 10AWG. Below is the damaged.
external battery cable reference according to system requirements.
Table 1 Minimum Recommended Battery Cable Size versus Length Connect to Utility and Charge
Plug in the AC input cord to the wall outlet. The unit will automatically charge the connected
Model Typical Amp. 1 meter (one-way) Dia-mm
external battery even though the unit is off.
600 50 A AWG 8 6.0
CAUTION! Do not disassemble the unit Contact with the qualified service center when service Connect External Battery
or repair is required. Step 1 - Install a DC Breaker in a positive battery line. The rating of the DC Breaker must be
WARNING! Provide ventilation to outdoors from the battery compartment. The battery according to the inverter's battery current (50 Amp). Keep the DC breaker off. (see Fig. 1)
enclosure should be designed to prevent accumulation and concentration of hydrogen gas at
the top of the compartment. Step 2- Connect battery cables to the terminals of battery.
CAUTION! Use insulated tools to reduce the chance of short-circuit when installing or working
with the inverter, the batteries, or other equipments attached to this unit. Note: For the user operation safety, we strongly recommend that you should use tapes to
CAUTION! For battery installation and maintenance, read the battery manufacturer's isolate the battery terminals before you start to operate the unit.
installation and maintenance instructions prior to operating.
1) Single battery connection(Refer to Fig. 1): When using a single battery, its voltage
must be equal to the Nominal DC Voltage of the unit (see below Table 1).

Model Nominal Battery DC Voltage

600 12 VDC

Table 1
2) Multiple batteries in series connection (Refer to Fig. 2): All batteries must be Model with LED Indicator & Audible Alarm
equal in voltage and amp hour capacity. The sum of their voltages must be equal to the There are three indicators (Green/Red/Yellow) in the front panel of the unit.
nominal DC Voltage of the unit. Status LED Indicator Alarm
The unit is in Line mode. Green LED on. Off
The unit is in Line mode and Green LED on and yellow LED
charging battery. flashes every 3 seconds.
Battery mode Yellow LED flashes every 10 Off
seconds.
Off-mode charging. Yellow LED flashes every 3 Off
seconds.
Fig 2
Yellow LED flashes every 0.5 Sounding every 0.5
3) Multiple batteries in parallel connection (Refer to Fig. 3): Each battery's voltage Overload warning
second second
must be equal to the Nominal DC Voltage of the unit. Yellow LED flashes every 0.5
Battery low warning Sounding every second
second
Output is short circuited. Yellow LED and Red LED are
Overload fault. on.
Output voltage is too low or too
high. Continuously sounding.
Fig 3 Battery bad Red LED is on and Green LED The unit will shut down
Step 3- Make sure to connect the polarity of battery side and the unit correctly. flashes every 0.5 seconds. after it’s in fault mode
Positive pole (Red) of battery to the positive terminal (+)of the unit. Battery is overcharging. Red LED and Green LED are for 15 seconds.
on.
Negative pole (Black) of battery to the negative terminal (-) of the unit.
Battery weak. Red LED flashes every 0.5
Step 4- Put the covers back to the external battery terminals.
second.
Step 5- Take the DC breaker on.

Model with LCD Display & Audible Alarm


Connect to Device
Status LCD Display Alarm
Simply plug devices to battery supplied sockets. During power failure, it will provide continuous
Line mode Off
power to connected devices.
Line mode with charging Off
6. Operation battery. and flashes
Battery mode Off
Power On/Off
Once the inverter has been properly installed, press the power switch to turn on the unit. The
Off-mode charging Off
unit will work automatically. When press the power switch again, the unit will be turned off.
and flashes
WARNING! The unit may have output power when connected to the utility, even though it is Fault mode Fault code will be displayed. Continuously sounding.
powered off. To completely cut off the output power, please switch off the unit and disconnect Output fault: F0 The unit will shut down
the unit from the utility. Overload: F1 after it’s in fault mode for
Over-charging: F2 15 seconds.
Battery bad: F3
High output voltage: F4
Low output voltage: F5
Battery weak: F6
The unit is overload. The mark will flash
every second.
Battery weak at battery
mode. The mark will flash every
second.
Load level indicator: Battery capacity indicator:
Display Load Level Display Battery Capacity
75%~100% battery voltage ≥
12.5V (25V)
50%~75% 12.5V (25V)> battery
voltage ≥ 11.5V (23V)
25%~50% 11.5V (23V)> battery
voltage ≥ 11.0V (22V)
0%~25% battery voltage <
11.0V (22V)

6. Trouble Shooting
Use the table below to solve minor problems.
Problem Possible Cause Solutions
Utility power is normal AC input power cord is not Check AC input power
but the unit is in connected well. connection.
battery mode. Input breaker is activated. Reset the input breaker.
When power fails, the The unit is overload. Remove some non-critical loads.
backup time is
shorten. Battery voltage is too low. Charge the unit at least 8 hours.

Battery capacity is not full Check the date code of the


even after charge the unit for battery. If the batteries are too
at least 8 hours. old, replace the
batteries.
Nothing display on the The unit is not turned on. Press power switch to turn on the
front panel when the unit.
utility power is Battery is not connected well. Check the external battery cable
normal. and terminal. Make sure all the
battery connections to the unit
are all correct.
Battery defect. Replace the batteries.
Battery voltage is too low. Charge the unit at least 8 hours.
The unit is in fault and The unit is overload. Verify that the load matches the
restart circularly. capability specified in the
specification.
Output is short circuited. Check the loads and remove loads
which cause short circuit.
If there any abnormal situations occur, which doesn't list above, please call the service
people immediately for professional examine.