TYPES OF DOSING UNITS AND

THEIR SELECTION FOR


GREENHOUSES

SABI Congress 2017


Nickie Theron
AGENDA
 Control Types
 Dosing Types
 Dosing Channel
 Control Cycle
 Dosing Units
 Flow Rates
 Examples
 Summary
TYPES OF DOSING UNITS AND THEIR SELECTION
Control Types
Inputs and outputs – levels of sophistication
 Digital outputs.
 Electric command
 Pumps
 Irrigation valves
 Fertiliser valves

 Digital inputs.
 Pulsed input
 Water meters
 Fertiliser meters

 Analogue inputs.
 Continuous signal
 EC
 pH
 Radiation (sunlight).
TYPES OF DOSING UNITS AND THEIR SELECTION
Control Types
Inputs and outputs – levels of sophistication
 Digital outputs.
 Electric command
 Time based controller
 Garden / landscape irrigation controller
 Simple filter flushing timer

 Digital inputs.
 Pulsed input Increasing level of sophistication
 Advanced filter flushing controller
 Irrigation by volume

 Analogue inputs.
 Continuous signal
 Highest level
 Fertigation – EC pH
 Irrigation based on radiation, temperature, RH.
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Types
Two main methods
 Batch
 No Specific concentration

 Continuous
 Proportional dosing
 EC pH monitoring
 EC pH control.
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Types
Two main methods
 Batch
 Only in soil
 Mainly in the open field: not greenhouses

Irrigation – no fertiliser Irrigation period – with fertiliser Irrigation – no fertiliser


TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Types
Two main methods
 Continuous
 Soil
 Soilless
 Essential
 Greenhouses.

 Fixed concentration - Direct proportional. Flow-on-flow. Fixed litres fertiliser per m³ irrigation
water.

Irrigation period – with fertiliser


TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Types
Continuous dosing
 Three levels
 Proportional dosing
 Proportional dosing with EC pH monitoring Increasing level of sophistication.
 EC pH control

Irrigation period – with fertiliser


TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Types
Continuous dosing
 Homogeneous fertiliser
 From fertiliser storage tanks
 To the crop

 Doing this with precision. Perfect


EC/pH controlling.

Irrigation period – with fertiliser


TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Types
Continuous dosing
 Link
 From tanks
 To the crop

 Dosing Unit

Irrigation period – with fertiliser


TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Continuous dosing
 Link
 From tanks
 To the crop

 Dosing channel
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Dosing channel key
components
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Dosing channel key
components
 Venturi
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Dosing channel key
components
 Venturi
 Solenoid valve
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Dosing channel key
components
 Venturi
 Solenoid valve
 Manual throttle valve
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Dosing channel key
components
 Venturi
 Solenoid valve
 Manual throttle valve
 Visual flow meter.
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Venturi
 One flow rate
 (Measured in litres / hour).

Fertiliser in
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Solenoid valve
 De-energised (at rest)
 Closed
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Solenoid valve
 Energised
 Open
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Solenoid valve
 Either
 Fully closed
 Fully open

 One flow rate


TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Manual throttle
 Fully open

Visual flow meter


 Solenoid valve open
 Float risen
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Manual throttle
 Partially close (choke)
 Less flow rate

Visual flow meter


 Solenoid valve open
 Flow rate reduces
 Float falls
 Less fertiliser through to
venturi.
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Dosing channel
 Venturi
 Fixed flow rate

 Solenoid
 Either
 Open
 Closed
 Either
 Flow
 No flow
 Either
 Fertiliser
 No fertiliser
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Dosing channel example
 Required flow rate of fertiliser solution into the irrigation system = 100 ℓ/h
80%
 Venturi flow rate = 125 ℓ/h

 If the solenoid remains open for a 1 h period, 125 ℓ will pass = Too much

 The solenoid valve opens for 0,8 h (48 minutes)


closes for 0,2 h (12 minutes).
20%
 In a one hour period (60 minutes), 100 ℓ will have passed through the
solenoid. Target achieved.
 Solenoid must be open for 80% of the time
closed for 20 % of the time
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Venturi and solenoid
 EC stability needed quickly and accurately

Overshoot
Too high

Target EC
EC Too low

Time
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Venturi and solenoid
 Ratio - venturi flow rate : irrigation flow rate (dependant / linked)
 Achieved by opening and closing dosing channel

Dosing method Min channel Max channel Irrigation pulse


opening time opening time
EC pH control 60 % 80 % < 30 minutes
Flow-on-flow 40 % 80 % 30 to 120 minutes
(with EC pH monitoring)
Flow-on-flow control 40 % 80 % 30 to 120 minutes

Volume - spread 10 % 80 % > 120 minutes

Volume bulk 10 % 80 % > 120 minutes


Time 10 % 80 % > 120 minutes
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Dosing channel example
Too much (Dosing flow rate too high)

EC Spike: high and low points

Target EC
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Channel
Dosing unit must reach target EC
Target EC
 Mixing EC
 Thorough
 Reached quickly

 Function of
 Controller software (firmware)
 Dosing unit design
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Units
Hydraulic proportional injection unit
 Three levels
 Proportional dosing.
 Proportional dosing with EC pH monitoring. Increasing level of sophistication
 EC pH control.
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Units
Open mixing tank
 EC pH control.
TYPES OF DOSING UNITS AND THEIR SELECTION
Fertiliser Dosing Units
Bypass units
PSV PRV
 EC pH control
Mainline Mixing
chamber
 Mixing chamber.

Booster pH pH
Dosing Unit Pump
EC EC
C
1 2 3 4 5
TYPES OF DOSING UNITS AND THEIR SELECTION
fertiliser Dosing Units System Inlet System Outlet

Mixing
Inline units chamber

PSV PRV
 Limited to flow constrains, as
pH pH
mainline runs through the unit.
 EC pH control EC EC

Booster
Mainline Pump
C
1 2 3 4 5

Dosing Unit
TYPES OF DOSING UNITS AND THEIR SELECTION
Control Cycle
The control cycle
 EC/pH control
TYPES OF DOSING UNITS AND THEIR SELECTION
Control Cycle
The control cycle
TYPES OF DOSING UNITS AND THEIR SELECTION
Control Cycle
Dosing unit design
 By pass with mixing chamber

Water
downstream -
to the unit

Water from the unit pushed back into


mainline - upstream
TYPES OF DOSING UNITS AND THEIR SELECTION
Control Cycle
Dosing unit design
 By pass with mixing chamber Main Homogeneous
line solution returns
to the mainline.

Mixing chamber
Some water
from the
Pump mainline is
pH
EC pumped through
the dosing unit
TYPES OF DOSING UNITS AND THEIR SELECTION
Control Cycle
Dosing unit design
 Open mixing tank
Pump

Venturis pH pH

Solenoid valves EC EC
TYPES OF DOSING UNITS AND THEIR SELECTION
Control Cycle
Dosing method Channel open time % Irrigation pulse Control cycle time
(minutes) (seconds)
Min % Max %
Proportional EC pH control 60 80 Less than 30 6 to 12
Flow-on-flow with EC pH 40 80 More than 30 9 to 18
monitoring
Flow-on-flow 40 80 More than 30 9 to 18
Batch Spread, Bulk or by Time 10 80 More than 120 n/a

Mixing
chamber
Main line
pH
Pump EC
TYPES OF DOSING UNITS AND THEIR SELECTION
Control Cycle
Never exceed a maximum opening time of 80%
 Required flow rate of fertiliser into the solution is 100 litres per
hour.
 Channel manually chocked to a flow rate of 100 litres / hour.
 Solenoid must be open for 80% of the time. – This case 100%
80%
 If the injection falls behind and needs to inject 110 litres / hour to
catch up, it will never catch up .
 It needs the 20% cushion to catch up.
 Do not use a 125 litre / hour venturi if the required dosing rate
is 125 litres / hour.

 Some probable causes: 20%


 Increase of irrigation flow rate
 Fertiliser injected are incorrect (mixed).
TYPES OF DOSING UNITS AND THEIR SELECTION
Control Cycle
Never drop below the prescribed
minimum % opening time
Mixing chamber
 Required flow rate of fertiliser into the
solution is 50 litres / hour.
 Venturi has a flow rate of 125 litres / hour.
 Solenoid must be open for 40% and closed
for 60% of the time. pH
 Insufficient mixing in the control cycle. EC
 Fertiliser in the irrigation water may not be
homogenous.
 Time from injection to EC pH sensors too
long.
 EC pH fluctuations in irrigation water.
TYPES OF DOSING UNITS AND THEIR SELECTION
Irrigation Flow Rates
 Reasonably equal flow rates from block to block
 Normally means equal size blocks.

P
TYPES OF DOSING UNITS AND THEIR SELECTION
Irrigation Flow Rates
 Irrigation flow rates can vary by not more than 25% at
one time.
 Irrigation flow rate to first block = 20 m³/h
 Dosing rate = 10 ℓ fertiliser / 1 m³ irrigation water
 Dosing rate into the control cycle = 200 ℓ/h
 Venturi flow rate for 80% opening time = 200 ℓ/h / 80% = 250 ℓ/h
 Throttle set to 250 ℓ/h

 Irrigation flow rate to second block = 15 m³/h (25% less than 20


m³/h)
 Dosing rate into the control cycle = 150 ℓ/h
 Venturi flow rate has already been set at 250 ℓ/h with the throttle.
 Venturi opening time = 60% (OK)
TYPES OF DOSING UNITS AND THEIR SELECTION
Irrigation Flow Rates
 Irrigation flow rates can vary by not more than 25% at
one time.
 Irrigation flow rate to first block = 20 m³/h
 Dosing rate = 10 ℓ fertiliser / 1 m³ irrigation water
 Dosing rate into the control cycle = 200 ℓ/h
 Venturi flow rate for 80% opening time = 200 ℓ/h / 80% = 250 ℓ/h
 Throttle set to 250 ℓ/h

 Irrigation flow rate to second block = 10 m³/h (50% less than 20


m³/h)
 Dosing rate into the control cycle = 100 ℓ/h
 Venturi flow rate has already been set at 250 ℓ/h with the throttle.
 Venturi opening time = 40% (Too little)
TYPES OF DOSING UNITS AND THEIR SELECTION
Irrigation Flow Rates
 When selecting a fertiliser dosing unit
with regard to its ability to dose the correct and
consistent quantity of fertiliser.
 All irrigation flow rates
 Highest and lowest

 All dosing flow rates


 Variations through the year

 Method of dosing
 Ability to cope within the open / closing times of the dosing channel
 Batch
 Proportional
 Flow-on-flow
 EC pH control.
TYPES OF DOSING UNITS AND THEIR SELECTION
Example – Selection sheet extract
DOSING UNIT DOSING CHANNELS IRRIGATION SYSTEM

Minimum calibration (% of time Maximum calibration (% of time

Compensation Channel
Dosing rate (ℓ fert/m3 water)
open) open)
Qty

Q
Model

100 80 60 40 10 100 80 60 40 10 min 12 10 4 2


(m3/h)
Flow rate (ℓ/h) per channel for Flow rate (ℓ/h) per channel for Maximum irrigation flow rate
Max
Min

minimum calibration and % maximum calibration and % open (m3/h) with channel 80% open on
open time time maximum calibration. (Note 1)

NetaJet 3G Inline 3 5 1 75 60 45 30 8 400 320 240 160 40 5 20 (Restricted by mixing chamber)


NetaJet 3G Bypass 3 5 1 75 60 45 30 8 400 320 240 160 40 20 27 32 80 160
NetaJet HF Bypass 3 5 1 300 240 180 120 30 1000 800 600 400 100 60 67 80 200 400
FertiKit 3G PL 3x150
3 3 0 75 60 45 30 8 150 120 90 60 15 2 10 12 30 60
230VAC
FertiKit 3G PL 3x150
3 3 0 75 60 45 30 8 150 120 90 60 15 2 10 12 30 60
400VAC
FertiKit 3G PL 4x400 4 4 1 75 60 45 30 8 400 320 240 160 40 20 27 32 80 160
FertiKit 3G PL 4x150 4 4 1 75 60 45 30 8 150 120 90 60 15 2 10 12 30 60
FertiKit 3G Inline
4 4 1 75 60 45 30 8 150 120 90 60 15 2 10 (Restricted by mixing chamber)
4x150
FertiKit 3G PL 4x1000 4 4 1 300 240 180 120 30 1000 800 600 400 100 60 67 80 200 400
TYPES OF DOSING UNITS AND THEIR SELECTION
Example
 Scenario:
 How many fertiliser tanks?
 Controlling pH? (Acid or Alkali)
 Controlling EC?
 Injection only (no EC/pH controlling)
 Let’s say: 1 x Acid tank (for decreasing pH); 3 x tanks of fertiliser that influence
EC (for increasing EC)

 What concentration of fertiliser does the crop require?


 The recipe
 How many litres of fertiliser per 1 000 litres water?
 Let’s say the 3 x EC tanks: 8 litres and 1 x Acid Tank 3 litres.

 What is the irrigation flow rate?


 Let’s say 85 to 100m3/h

 At what pressure?
 Let’s say 4.5Bar.
TYPES OF DOSING UNITS AND THEIR SELECTION
Example
 Scenario requirements:
 Flow Rate: 100m3/h @4.5Bar
 Tank 1 (Acid) 3 litre per 1m3/h
 Thus: 100 x 3 = 300 ℓ/h
 300 ℓ/h /80% = 375 ℓ/h

 Tank 2,3 and 4 (EC) 8 litre per 1m3/h


 Thus: 100 x 8 = 800 ℓ/h
 800 ℓ/h /80% = 1 000 ℓ/h

 Dosing unit required:


 Dosing unit with 4 channels:
 1 x 375 ℓ/h and 3 x 1 000 ℓ/h

 Flow rate 100m3/h at 4.5Bar


 EC and pH Controlling
TYPES OF DOSING UNITS AND THEIR SELECTION
Example – Selection sheet
DOSING UNIT DOSING CHANNELS IRRIGATION SYSTEM

Minimum calibration (% of time Maximum calibration (% of time

Compensation Channel
Dosing rate (ℓ fert/m3 water)
open) open)
Qty

Q
8
Model

100 80 60 40 10 100 80 60 40 10 min 12 10 4 2


(m3/h)
Flow rate (ℓ/h) per channel for Flow rate (ℓ/h) per channel for Maximum irrigation flow rate
Max
Min

minimum calibration and % maximum calibration and % open (m3/h) with channel 80% open on
open time time maximum calibration. (Note 1)

NetaJet 3G Inline 3 5 1 75 60 45 30 8 400 320 240 160 40 5 20 (Restricted by mixing chamber)


NetaJet 3G Bypass 3 5 1 75 60 45 30 8 400 320 240 160 40 20 27 32 80 160
NetaJet HF Bypass 3 5 1 300 240 180 120 30 1000 800 600 400 100 60 67 80 200 400
FertiKit 3G PL 3x150
3 3 0 75 60 45 30 8 150 120 90 60 15 2 10 12 30 60
230VAC
FertiKit 3G PL 3x150
3 3 0 75 60 45 30 8 150 120 90 60 15 2 10 12 30 60
400VAC
FertiKit 3G PL 4x400 4 4 1 75 60 45 30 8 400 320 240 160 40 20 27 32 80 160
FertiKit 3G PL 4x150 4 4 1 75 60 45 30 8 150 120 90 60 15 2 10 12 30 60
FertiKit 3G Inline
4 4 1 75 60 45 30 8 150 120 90 60 15 2 10 (Restricted by mixing chamber)
4x150
FertiKit 3G PL 4x1000 4 4 1 300 240 180 120 30 1000 800 600 400 100 60 67 80 200 400
TYPES OF DOSING UNITS AND THEIR SELECTION
Summary
 When selecting a fertiliser dosing unit with regard to its
ability to dose the correct and consistent quantity of
fertiliser.
 Designing an irrigation system together with a fertiliser dosing
system at the same time is relatively straightforward.
 Fitting a fertiliser dosing system to an existing irrigation system
can be more challenging.