Perkins ‐ Generator Engine Specs

        EMS: Engine management System      
Standby      E : Electronic Governor     Fuel Consumption
kVA  kVA  Engine  Model  Silin‐  kW Turbo Inter Alternator Meg KVA  ISOL  L/ hour
JHB  SEA        der    cool Gov Alter  AMP  50% 75% 100%
10.5  10  Perkins  403C‐11G  3  9.4 x x To be a 13  63  1.5 2 2.9
12.3  14.5  Perkins  403C‐15G  4  13.3 x x advised a 13  63  2.1 2.8 4.1
19.3  22.7  Perkins  404C‐22G  4  20.4 x x To be a 20  63  2.9 4 6.2
30  33  Perkins  1103A‐33G  3  29 x x advised a 30  80  3.9 5.4 7.9
48  50  Perkins  1103A‐33TG1 3  44 a x To be a 42  80  5.7 8.2 10.7
62  66  Perkins  1103A‐33TG2 3  59 a x advised a 63  125  7.3 10.5 14.1
69  72  Perkins  1104A 44TG1 4  64 a x To be a 75  125  8 11.2 16.2
85  88  Perkins  110A 44TG2  4  78 a x advised a 80  125  9.7 14 18.7
85  88  Perkins  1104C 44TAG1  4  78 a x To be a 80  125  9.8 14.3 20.3
98  104  Perkins  1006 TG 1A  6  92.7 a x advised a 100  250  12 17.9 24.3
106  110  Perkins  1104C 44TAG2  4  98 a x To be a 100  160  11 17.1 22.6
107  114  Perkins  1006 TG 2A  6  102 a x advised a 100  250  17 24.1 31.5
140  150  Perkins  1006 TAG  6  134 a a To be E 150  250  20 29.6 38.2
158  165  Perkins  1006 TAG2  6  144 a a advised E 150  250  12 17.9 24.3
192  207  Perkins  1306E87TTAG2  6  180 a a To be E 200  400  23 32.2 44.6
235  250  Perkins  1306E87TTAG4   6  217 a a advised E 250  400  26 37.5 53
264  275  Perkins  1306E87TTAG6   6  217 a a To be E 300  400  29 42 59.9
384  400  Perkins  2306C‐E14TAG2  6  344 a a advised E 400  630  38 52.5 70.6
432  450  Perkins  2306C‐E14TAG3  6  387 a a To be E 450  630  42 60.9 81.1
                advised ABB Motor Change Over Switch 24 Volt DC
480  500  Perkins  2806C‐E16TAG1  6  430 a a To be E 500  800  49 71.6 105
528  550  Perkins  2806C‐E16TAG2  6  468 a a advised E 550  800  54 79.2 105
629  630  Perkins  2806C‐E18TAG1  6  542 a a To be E 680  1,000  56 81 108
672  700  Perkins  2806C‐E18TAG2  6  602 a a advised E 720  1,000  63 92 125
768  800  Perkins  4006TAG2A 6  685 a a To be E 800  1,250  Specs on application 
864  900  Perkins  4006TAG3A 6  760 a a advised E 930  1,600  Specs on application 
897  935  Perkins  4008TAG  8  787 a a To be E 950  1,600  93 134 203
956  996  Perkins  4008TAG1  8  839 a a advised E 1050  1,600  101 147 202
                ABB Motorized Circuit Breakers
1080  1125  Perkins  4008TAG2  8  947 a a To be E 1150  2,000  112 167 241
1090  1136  Perkins  4012TWG  V12  957 a a advised E 1150  2,000  128 183 241
1356  1403  Perkins  4012TWG2  V12  1169 a a To be E 1300  2,500  143 209 280
1344  1401  Perkins  4012TAG  V12  1168 a a advised E 1300  2,500  143 211 288
1449  1500  Perkins  4012TAG1  V12  1250 a a To be E 1600  2,500  141 213 291
1589  1656  Perkins  4012TAG2  V12  1380 a a advised E 1600  3,200  157 238 325
1851  1929  Perkins  4016TAG  V16  1507 a a To be E 1875  3,200  193 270 360
1946  2028  Perkins  4016TAG1  V16  1690 a a advised E 1875  3,200  195 293 405
2173  2264  Perkins  4016TAG2  V16  1886 a a E 2150  3,500  237 342 459