Teste e Ajustes
3176C e 3196 Motores para Máquinas Construídas Caterpillar
Número de Mídia -SENR9528-03 Data de Publicação -01/03/2003 Dados de Atualização -19/03/2003

i01467399

Bomba de Água - Teste


SMCS - 1361-040; 1361-081

tabela 1
Ferramentas necessárias
Número da peça Nome da peça Quantidade

6V-7775 Medidor de pressão de ar 1

Ilustração 1 g00439003
Typical example
(1) Port
(2) Coolant temperature sensor
(3) Water manifold assembly
(4) Water outlet
(5) Coolant temperature regulator
(6) Bypass line
(7) Water pump
(8) Port

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/productsearch/productheaderinfoframeset.jsp&called… 1/2
12/03/2019 16H Motor Grader ATS00001-UP (MACHINE) POWERED BY 3196 Engine(SEBP3329 - 89) - Sistemas e componentes

Making contact with a running engine can cause burns from hot parts
and can cause injury from rotating parts.

When working on an engine that is running, avoid contact with hot


parts and rotating parts.

Perform the following procedure in order to determine if the water pump is operating correctly:

1. Remove the plug from port (1).

2. Install the 6V-7775 Air Pressure Gauge in port (1).

3. Start the engine. Run the engine until the coolant is at operating temperature.

4. Note the water pump pressure. The water pump pressure should be 100 to 125 kPa (15 to 18 psi).