Sunteți pe pagina 1din 7

1 2 3 4 5 6

A A

NOTES:
State: RELEASE - Document is released and under formal Change Control. Changes are subject to the ECR/ECO Process.

SHEET_NAME SHT_NUM REV


BLOCK 2
INPUT 3
HVDC 4
B AXIAL DRIVE 5 B

LVAC 6
CUSTOMER I/O 7
REVISION PCN NUMBER DATE SIGN OFF
See the GEMS ePDM System to determine the status of this document.

C C

标记 REV QTY 改单号 FZ2 No. 签字 MADE BY 日期 DATE 描 述 DESCRIPTION


名称
D
GEHW MEDICAL SYSTEMS TITLE
NGPDU-3 SCH D

设计 DESIGNER 比 例 SCALE
文件代号 DOC.NO
审 核 CHECKER
复 审 RECHECKER
标 审 STANDARD 2326492-3SCH
批准 APPROVAL sheet 1 of 7
1 2 3 4 5 6

Approved Document - 2326492-3SCH_r1.pdf Page 2 of 14


1 2 3 4 5 6

NGPDU-3 BLOCK DIAGRAM


A A

AXIAL PWR CNTL


HVAC1(3:1) HVDC ASSEMBLY 1
440Y254-A TS3-1
INPUT POWER AND TRANSFORMER ASM 2
440Y254-B TS3-2 AXIAL DRIVE
1 3 CABLE TO GANTRY
474Y273-A TS2-1 440Y254-C TS3-3
1
474Y273-A TS2-2 HVDC TS3-4
2 2
474Y273-B 474Y273-B TS2-3 CABLE
3
TS1-L1 474Y273-C
3 1 2
TS1-L2 474Y273-C Vss-A KSV-P24
MAINS INPUT TS1-L3 440Y254-A 1
Vss-B 3 4
KSV-A1 LP-CONT-CLSD
2 5 8
GND 440Y254-B Vss-C KSV-A2
3
440Y254-C
3 1 Sheet 5
PDU-24-F CAP-P
1 5
208Y120-A CAP-M
2 10 8 7
208Y120-B KXG-A1 CAP-N
3 11
208Y120-C KXG-A2
1 4
C1 X0
2 SHUNT TRIP 5
C2 Y0
6 4 LVAC PWR DIST AND UPS INTERFACE
KSS-A1 XG-CONT-CLSD
1 12 7 1
B TEMP1 KSS-A2 KSS-CONT-CLSD 208Y120-A B
2 2 1
TEMP2 208Y120-B 120V
Sheet 4 3 2
208Y120-C 0Vac
Sheet 3 J7(12:1) 4
X0
HVAC(3:1) 5
Y0 TS5-0
LVAC(5:1)
TS5-1 CONSOLE
J3(2:1) 3 POWER
KTG-P24 TS5-2
J8(2:1) 5
KTG-A1 TS5-3
6
J9 KTG-A2 TS5-4
9
GANTRY-PWR-CLSD TS5-5
1 PDU-24 1
TS5-6 CT GANTRY
14 PDU-PGND 14 POWER
CONTROL BOARD TS4-1 TS5-7
2 PDU-24 2 To Gantry Switch NC TO UPS TS4-2 TS5-8
15 PDU-PGND 15 To Thermal SW
Pin16 GANTRY-PWR

TS4-3 TS5-9
3 GANTRY-PWR-CLSD 3 1 J7(12:1) ( OPTIONAL )
J3-1 J7(12:1) TS4-4 TS5-10 AUX DP CAB
Pin19 XG-CONT

16 GANTRY-PWR-116 2 POWER
J3-2 FROM UPS TS4-5 TS5-11
4 ESTP-SRC 4 J2(8:1)
J2(8:1) TS4-6 TS5-12
17 EXP-INTLK 17
5 LP-CONT-CLSD 5 1 J1(5:1) Sheet 6
J8-1 J1(5:1)
18 CLSELOOP 18 2
J8-2
6 XG-CONT-CLSD 6
19 XG-CONT 19 J6(9:1)
J6(9:1)
7 KSS-CONT-CLSD7
J9(25:1) CUSTOMER I/O
20 XRAYLITE 20 1 CUSTOMER CONNECTIONS
PDU-24
8 PHASE-LOSS 8 2
GANTRY-PWR-CLSD TS6-1
21 SYSLITE 21 3 LVAC INPUT
C J12-1 ESTP-SRC TS6-2 C
9 ILK-OPN 9 J10(3:1) 4
J12-2 J10(3:1) PGND TS6-3
22 RDYLITE 22 X-RAY LIGHT
TS6-4
10 BUSS-FLT 10 J5(4:1) 3
J5(4:1) CUST24 TS6-5
23 XG-ENBL-CONT 23 1 1 SYS-ON LIGHT
J4-1 CUST-NEUT TS6-6
11 OVR-TEMP 11 POWER SUPPLY 2 6
J4-2 J11(8:1) XR-ON-LITE TS6-7
24 24 2 READY LIGHT
12 12 1 ~ +
8
SYS-ON-LITE TS6-8
120V 24VDC see 2334820-2SCH GEN-RDY-LITE TS6-9
25 25 2 1 DOOR INTLK SW
0VAC PGND EXP-INTLK TS6-10
13 2
~ - PGND Sheet 7
J11(8:1)
DB25 J4(2:1)

CNTL(25:1)

SYSTEM INTERFACE

标记 REV QTY 改单号 FZ2 No. 签字 MADE BY 日期 DATE 描 述 DESCRIPTION


名称
D
GEHW MEDICAL SYSTEMS TITLE
NGPDU-3 SCH D

设计 DESIGNER 比 例 SCALE
文件代号 DOC.NO
审 核 CHECKER
复 审 RECHECKER
标 审 STANDARD 2326492-3SCH
批准 APPROVAL sheet 2 of 7
1 2 3 4 5 6
1 2 3 4 5 6

A A
State: RELEASE - Document is released and under formal Change Control. Changes are subject to the ECR/ECO Process.

INPUT POWER AND TRANSFORMER ASSEMBLY

T1

X0

X0
. X1
208Y120-A
X0
H1

.
. X2
1 2 3 4 5 6 H 208Y120-B
X0
. X3
208Y120-C
B B
CB1
TS1
H2 SHIELD

.
TS1-L1
TS1-L2 1 2 3 4 5 6 H
TS1-L3
Y0
125A

Y0 Y1
.
Y4 474Y273-A
SHUNT TRIP
H3 474Y273-B

.
GND
1 2 3 4 5 6 H
Y0 Y2 474Y273-C
.
Y5

C1 C2 C3
See the GEMS ePDM System to determine the status of this document.

Y0 Y3
.
Y6
C1 C1,C2,C3 = 6.0 UF, 370VAC
440Y253-A
C2
FLOATING WYE CONFIGURATION 440Y253-B
REQUIRED FOR EMC PREVENTION
C GE97F9595, OR MALLORY C32FD3706 OR EQUAL 440Y253-C C

TEMP2
TEMP1
JUMP SHOWN IN 480V CONNECTION

PRIMARY SECONDARY
LEAD LEAD
VOLTAGE VOLTAGE
CONNECTION CONNECTION
380v 2-6 208Y120 X1,X2,X3,X0
400v 2-5
420v 2-4 474Y273 Y1,Y2,Y3,Y0
440v 3-6
460 3-5
480v 3-4
440Y253 Y4,Y5,Y6,Y0

标记 REV QTY 改单号 FZ2 No. 签字 MADE BY 日期 DATE 描 述 DESCRIPTION


名称
D
GEHW MEDICAL SYSTEMS TITLE
NGPDU-3 SCH D

设计 DESIGNER 比 例 SCALE
文件代号 DOC.NO
审 核 CHECKER
复 审 RECHECKER
2326492-3SCH
标 审 STANDARD
批准 APPROVAL sheet 3 of 7
1 2 3 4 5 6

Approved Document - 2326492-3SCH_r1.pdf Page 4 of 14


1 2 3 4 5 6

A A

HVDC ASSEMBLY
State: RELEASE - Document is released and under formal Change Control. Changes are subject to the ECR/ECO Process.

VF1

VF2

VF3

C4, C5, C6 = 6.0 UF, 370 VAC


GROUNDED WYE CONFIGURATION
F1 REQUIRED FOR EMC PREVENTION
474Y273-A
B KXG GE97F9595, OR MALLORY C32FD3706 OR EQUAL BR1 C7 B
100A 13 14 4600uF
~ TS2
F2 5 6 + TS2-1
474Y273-B 3 4 ~ TS2-2
HVDC CABLE
1 2 TS2-3
100A TO GANTRY
A1 A2 ~ -
F3 C8
474Y273-C 4600uF
100A C4 C5 C6
6uF 6uF 6uF

KXG-A1
KXG-A2
CAP-P
PDU-24-F CAP-M
See the GEMS ePDM System to determine the status of this document.

XG-CONT-CLSD CAP-N
KSS-CONT-CLSD

KSS
13 14 R1
5 6 22
C 3 4 R2 C
1 2 22
A1 A2 R3
22
KSS-A1
R1, R2, R3 = 50W
KSS-A2
EACH

标记 REV QTY 改单号 FZ2 No. 签字 MADE BY 日期 DATE 描 述 DESCRIPTION


名称
D
GEHW MEDICAL SYSTEMS TITLE
NGPDU-3 SCH D

设计 DESIGNER 比 例 SCALE
文件代号 DOC.NO
审 核 CHECKER
复 审 RECHECKER
标 审 STANDARD
2326492-3SCH
批准 APPROVAL sheet 4 of 7
1 2 3 4 5 6

Approved Document - 2326492-3SCH_r1.pdf Page 5 of 14


1 2 3 4 5 6

A A
State: RELEASE - Document is released and under formal Change Control. Changes are subject to the ECR/ECO Process.

AXIAL DRIVE POWER CONTROL

B B

LP-CONT-CLSD

KSV
CB2
13 14 TS3
439Y253-A 5 6 TS3-1
439Y253-B 3 4 TS3-2
439Y253-C 1 2 TS3-3 440VAC TO GANTRY AXIAL DRIVE
A1 A2 TS3-4
16A
See the GEMS ePDM System to determine the status of this document.

PDU-24-F

KSV-A1

KSV-A2
C C

标记 REV QTY 改单号 FZ2 No. 签字 MADE BY 日期 DATE 描 述 DESCRIPTION


名称
D
GEHW MEDICAL SYSTEMS TITLE
NGPDU-3 SCH D

设计 DESIGNER 比 例 SCALE
文件代号 DOC.NO
审 核 CHECKER
复 审 RECHECKER
标 审 STANDARD
2326492-3SCH
批准 APPROVAL sheet 5 of 7
1 2 3 4 5 6

Approved Document - 2326492-3SCH_r1.pdf Page 6 of 14


1 2 3 4 5 6

A A
LVAC POWER DISTRIBUTION
State: RELEASE - Document is released and under formal Change Control. Changes are subject to the ECR/ECO Process.

CB9
120F
4A
0VAC

CB7 TS5
TS5-1
20A TS5-2
CONSOLE POWER
TS5-3

GANTRY POWER CONTACTOR


CB6
16A
KTG
CB8
13 14 TS5
CB3 32A 5 6 TS5-4
B 208Y120-A 3 4 TS5-5
B
CB5
1 2 TS5-6
208Y120-B 40A A1 A2 TS5-7
CT GANTRY POWER
TS5-8
CB4
208Y120-C
10A
40A TS5

120V-A
120V-B
120V-C
TS5-9
TS5-10
PET GANTRY POWER
TS5-11

UPS POWER INTERFACE


---------------------------------------------
PDU SHIPPED WITH JUMPERS
IN PLACE AS SHOWN.
See the GEMS ePDM System to determine the status of this document.

TO CONNECT TWO PHASE UPS ( CT ONLY ): TS4


1 - REMOVE JUMPERS "A" & "C"
2 - CONNECT INPUT POWER TO UPS TO 1 AND 3
TS4-1
TS4-2
TS4-3
TS4-4
TS4-5

TS4-6
TS4-7
TS4-8
TS4-9
TS4-10

3 - CONNECT UPS OUTPUT POWER TO 6 AND 8


4 - CONNECT INPUT & OUTPUT NEUTRAL &
A
GROUND
B
C
KTG-P24
KTG-A1
C KTG-A2 C
GANTRY-PWR CLSD

NEUTRAL GROUND
X0

Y0

标记 REV QTY 改单号 FZ2 No. 签字 MADE BY 日期 DATE 描 述 DESCRIPTION


名称
D
GEHW MEDICAL SYSTEMS TITLE
NGPDU-3 SCH D

设计 DESIGNER 比 例 SCALE
文件代号 DOC.NO
审 核 CHECKER
复 审 RECHECKER
2326492-3SCH
标 审 STANDARD
批准 APPROVAL sheet 6 of 7
1 2 3 4 5 6

Approved Document - 2326492-3SCH_r1.pdf Page 7 of 14


1 2 3 4 5 6

A A
State: RELEASE - Document is released and under formal Change Control. Changes are subject to the ECR/ECO Process.

CUSTOMER I/O

PDU-24 GANTRY-PWR
B B

GANTRY-PWR-CLSD

+ +

Gantry power switch


E-STOP SYS-ON Gantry power
ESTP-SRC GANTRY-PWR-1

PGND
See the GEMS ePDM System to determine the status of this document.

TS6
CUST24 TS6-1
CUST-NEUT TS6-2 LVAC INPUT
XR-ON-LITE TS6-3
TS6-4 X-RAY LIGHT
SYS-ON-LITE TS6-5
TS6-6 SYS-ON LIGHT
GEN-RDY-LITE TS6-7
C TS6-8 READY LIGHT C
EXP-INTLK TS6-9
PGND TS6-10 DOOR INTLK SW

Customer Room Interface

标记 REV QTY 改单号 FZ2 No. 签字 MADE BY 日期 DATE 描 述 DESCRIPTION


名称
D
GEHW MEDICAL SYSTEMS TITLE
NGPDU-3 SCH D

设计 DESIGNER 比 例 SCALE
文件代号 DOC.NO
审 核 CHECKER
复 审 RECHECKER
2326492-3SCH
标 审 STANDARD
批准 APPROVAL sheet 7 of 7
1 2 3 4 5 6

Approved Document - 2326492-3SCH_r1.pdf Page 8 of 14