Panelboards

CD2P & CEWP (Factory Sealed) ............................................ 86


Illustrated Features ............................................................ 87
CD2P Series Selection Table ............................................. 89
CEWP Series Selection Table ........................................... 90
Dimensions ......................................................................... 91
Wiring System Diagrams ................................................... 92

Panel Boards
CLPN, CPPN & CGPN (Non-Factory Sealed) ...................... 93
CLPN Series Selection Table ............................................ 94
CPPN Series Selection Table ............................................ 95
Main Lug Dimensions and Mounting Hardware .............. 97
Main Breakers Dimensions and Mounting Hardware ...... 99

CGPN Ground Fault Interrupting


Distribution Panelboard (Non-Factory Sealed) ................ 101
Dimensions and Mounting Hardware ............................. 102
Panelboard Data Sheet.................................................... 103

CPPF 480, 600 Volt Power Distribution


(Factory Sealed) ..................................................................... 104
Selection Table and Wiring Diagram .............................. 105
Options, Dimensions and Mounting Hardward .............. 106
Panelboard Data Sheet.................................................... 107

CLPF Lighting Distribution (Factory Sealed) ................... 108


Selection Table and Wiring Diagram ............................... 109
Panelboard Data Sheet .................................................... 107

Visit our website at www.egs-curlee.com or


contact Technical Services at (800) 631-6815 with any questions. 85
7 Panelboards

CD2P and CEWP Factory Sealed Panelboards

Applications
• Protection and control of electrical equipment and circuits
such as lighting and heat tracing in hazardous locations or
in damp, wet or corrosive conditions.
• CD2P Series — designed for use in Class I, Division 2
areas where ignitable vapors or gases may be present
under unusual conditions, or in Class II, Division 1 areas
where combustible dusts are present.
• CEWP Series — designed for use in Class I and Class II,
Division 1 manufacturing and processing areas where
ignitible vapors, gases or combustible dusts are present.
• Group B standard on all CD2P and CEWP panelboards.

Features
• Panel sizes:
“A” Board — up to 12 single-pole spaces Standard Materials
“B” Board — up to 24 single-pole spaces
• Housings: copper-free aluminum.
“C” Board — up to 36 single-pole spaces.
• Hardware: Stainless steel.
• 3” Main conduit openings for both top and bottom feed
of junction compartment.
Standard Finishes
• Permits selection of 1-, 2- or 3-pole breakers. 10,000 amp
• Housings: Grey epoxy powder coat.
AC interrupting capacity is standard. (22,000 A.I.C. also
available; contact factory.)
• Aluminum breaker actuators — spring loaded, corrosion
Options
resistant—feature self-locating design for actuating 1-, 2-, • For bottom and side feed only (No conduit holes drilled
or 3-pole breakers in any sequence. Rotary actuating in top) Add suffix —NTE
handles may be individually padlocked. • Drain and breather sets. Suffix —DV.*
• Handles lock in either OFF or ON position without interfer- • Grounded neutral lug. Suffix —GNL.*
ing with tripping of breakers.
• GFI circuit breakers. Suffix —GFI* (available on all
• Double door — one for junction compartment and one for positions.)
breaker compartment. Both doors are fully gasketed to
provide raintight fit for both compartments. • Factory installed main circuit breaker (maximum 100 Amp).
Maximum of two main breakers per panelboard permitted
• Two O-ring gaskets on each breaker handle shaft to by NEC 384-16(a). Suffix —MB* for each main breaker.
prevent entrance of water or corrosion. Main circuit breaker occupies branch breaker spaces.
• Hinges allow the doors to be lifted off. • Factory installed wired spaces for later installation of circuit
• Breakers prewired to terminal block minimizes breakers in the field, on request. Consult factory for information.
installation time. • For Breakers for use in H.I.D. lighting applications,
• Insulated neutral lug provided as standard. suffix —HID.*
• Panelboards use off-the-shelf Quicklag®† circuit breakers.
• Provision for drains/breathers in both compartments. Compliances
• Factory-sealed — no external branch sealing fittings • NEMA 3, 3R, 4, 4X, 5, 7BCD, 9EFG, 12.
needed (except Div. 1 Groups B and C). • UL Standard 1203 and 1604.
• Voltage ratings: 120VAC for single pole and up to
240 VAC for two or three pole. †Quicklag® is a registered trademark of Cutler-Hammer®.
*See Ordering information.
• Type THHN minimum size #10 AWG copper wire (90°C)
used in panelboards. Main lug feeder wires are crimped
and installed in single conductor.
• Stainless steel captive, spring-out QuadLead® bolts for
ease of access.
Visit our website at www.egs-curlee.com or
86 contact Technical Services at (800) 631-6815 with any questions.
Panelboards 7
CD2P and CEWP Factory Sealed Panelboards
Illustrated Features

Improved Patented
Actuator Handles
Wire Management
Two Door Design Rotary breaker handles provide
Breaker wiring in the lower compartment
dependable performance under heavy
Breaker compartment and junction is installed in the factory, saving installa-
corrosion conditions. Handle also gives
compartment can be accessed tion time on the job site. Individual circuit
positive visual indication of breaker
independently of each other. connections are made at terminal blocks
position. Improved spring-loaded
which are conveniently located in the
breaker actuators are also designed
front of the junction compartment. No. 10
Factory Sealed for corrosion resistance and are
wire is used throughout the panelboard
completely self-locating.
Sealing cement seals and protects wiring breaker compartment. Wire bundles are
where it passes from junction to circuit crimped with a UL Listed method, and
breaker compartment. Branch hubs do insulated for main lug assembly.
not require external seals to maintain
hazardous location ratings (except Div. 1,
Group B and C).

12 Circuit

24 Circuit
Main Feed
Watertight Gasketed Doors
Conduit Openings
Each door has an independent watertight
3” conduit openings at the top and
gasket for NEMA 4 performance.
bottom of the junction compartment
permit either top or bottom feed entry.
Threaded branch hubs are placed on
all four sides for versatility and ease of
36 Circuit
installation.

12, 24, or 36 Circuits


The CEWP/CD2P Panelboard lines are
available in 12, 24 or 36 circuit
versions.

Visit our website at www.egs-curlee.com or


contact Technical Services at (800) 631-6815 with any questions. 87
7 Panelboards

CD2P and CEWP Factory Sealed Panelboards


Illustrated Features

Removable Doors
Standard hinge position
allows either door to be lifted off the Corrosion-Resistant Housing
enclosure to provide easy access to the The junction and breaker housing are
interior. constructed of a rugged, one-piece,
two-compartment integral casting of
copper-free aluminum. Heavy-duty
stainless-steel mounting brackets allow
easy installation. The exterior and interior
Flexibility in Breaker Selection of the housing and doors have epoxy
In addition to having 36 circuits avail- powder coat finish.
able, one-, two-, or three-pole breakers
may also be specified in any combina-
tion. Ground-Fault Circuit Interrupters
may also be specified for any and all
breaker positions, with test buttons lo-
cated adjacent to the breaker operating
handle.

Breaker Voltage Specifications


Tamper Proof Construction
Provisions for padlocking individual Continuous Maximum Interrupting
breakers in either ON or OFF position Number Current Breaker Capacity
are provided on the front of the breaker Breaker Type of Poles Range (Amps) Volt Range Maximum Amps
compartment. 1 10 - 100 120/240 10,000
QC 2 10 - 100 120/240 10,000
3 10 - 100 240 10,000

QPGF (GFI) or 1 15 - 40 120 10,000


QPGFEP (EPD) 2 15 - 50 120/240 10,000

QC(HID) 1 15 - 60 120/240 10,000


2 15 - 60 120/240 10,000

For 22,000 A.I.C. rated breakers contact factory.

Visit our website at www.egs-curlee.com or


88 contact Technical Services at (800) 631-6815 with any questions.
Panelboards 7
CD2P Factory Sealed Panelboards Class I, Div. 2 Groups B, C, D
Class II, Div. 1 & 2 Groups E, F, G
For use with Threaded Metal Conduit or Approved Cable Terminators Class III
Class I, Zone 1, AEx de IIB
NEMA 3, 3R,4, 4X, 5, 7BCD, 9EFG, 12
Sample Catalog Number
CD2P 25 B - 9 15 - 3 50 - 7 20 - 1 30 2 - MB 100 Instructions
PANEL TYPE 1. Select Panel Type: CD2P.
WIRING SYSTEM 2. Select Wiring System Diagram
PANEL SIZE Number from page 92
QTY OF BREAKERS (switching neutral, solid neutral
or without neutral).
AMPERE RATING
QTY OF BREAKERS 3. Select Panelboard Size:
AMPERE RATING A (max. 12 single-pole spaces),
QTY OF BREAKERS B (max. 24 single-pole spaces) or
AMPERE RATING C (max. 36 single-pole spaces).
QTY OF BREAKERS 4. Insert dash and select Breakers as
AMPERE RATING desired in panelboard. First number
NUMBER OF POLES (include only if different from wiring system) is quantity of breakers (1 5-60A for
1P and 15-100A for 2P, 3P); second
MAIN BREAKER (number of poles depends on wiring system)
number, ampere rating (continuous);
AMPERE RATING and third number, number of poles.
(Indicate only if different from wiring
Selection Table1 diagram selected). Each breaker pole
Number Main Wiring Wiring takes one space.
of Lug Cable Panel Approx. System No. 4 System No. 5 5. Add dash and repeat step 4 for
Breakers Amp. Max. Range Size Wt. (lbs.) 120/240V AC 120/208V AC Additional Breakers as desired.
6 250 250 MCM to 6 A 150 CD2P4A-6 CD2P5A-6 6. Add dash preceding each DV, GNL
8 250 250 MCM to 6 A 150 CD2P4A-8 CD2P5A-8 or MB suffix (see “Factory Installed
10 250 250 MCM to 6 A 150 CD2P4A-10 CD2P5A-10 Accessories”). The correct number
12 250 250 MCM to 6 A 150 CD2P4A-12 CD2P5A-12 of poles for the Main Breaker will be
supplied automatically, depending on
14 250 250 MCM to 6 B 170 CD2P4B-14 CD2P5B-14 wiring system diagram selected. Maxi-
16 250 250 MCM to 6 B 170 CD2P4B-16 CD2P5B-16 mum of two main breakers allowed by
18 250 250 MCM to 6 B 170 CD2P4B-18 CD2P5B-18 NEC 384-16(a).
20 250 250 MCM to 6 B 170 CD2P4B-20 CD2P5B-20 Note: Main breakers use 2 or 3 branch circuit
22 250 250 MCM to 6 B 170 CD2P4B-22 CD2P5B-22 spaces.
24 250 250 MCM to 6 B 170 CD2P4B-24 CD2P5B-24
26 250 250 MCM to 6 C 190 CD2P4C-26 CD2P5C-26 Options and
28 250 250 MCM to 6 C 190 CD2P4C-28 CD2P5C-28 Factory Installed Accessories
30 250 250 MCM to 6 C 190 CD2P4C-30 CD2P5C-30
32 250 250 MCM to 6 C 190 CD2P4C-32 CD2P5C-32 Description Suffix
34 250 250 MCM to 6 C 190 CD2P4C-34 CD2P5C-34 Drain and Breather -DV
36 250 250 MCM to 6 C 190 CD2P4C-36 CD2P5C-36 Grounded Neutral Bar -GNL
1
Catalog numbers shown are panelboards with single-pole breakers for wiring systems 4 and 5. To Main Breaker -MB3
order 1-, 2- and/or 3-pole breakers with different wiring systems page 92 ), use “Ordering Informa-
tion” below. Add ampere rating (continuous): 15 through 60 for 1P, and 15 through 100 for 2P & 3P. Ground Fault Interrupter -GFI2
(Single or Two Pole -5 mA sensitivity)
“A” Board
Equipment Protection Devices -EPD2
(12 Circuit)
(Single or Two Pole -30 mA sensitivity)

Ground Terminal Bar -GJ2


HID rated breaker -HID
“B” Board “C” Board
(24 Circuit) (36 Circuit) No Top Entry -NTE
2
Consult factory.
3
Add ampere rating (max. 100A).

Visit our website at www.egs-curlee.com or


contact Technical Services at (800) 631-6815 with any questions. 89
7 Panelboards

CEWP Factory Sealed Panelboards Class I, Div. 1 & 2 Groups B†, C†, D
Class II, Div. 1 & 2 Groups E, F, G
For use with Threaded Metal Conduit Class III NEMA 3, 3R, 4, 4X, 5, 7BCD,
9EFG,12

Sample Catalog Number Instructions


CEWP 25 B - 9 15 - 3 50 - 7 20 - 1 30 2 - MB 100 1. Select Panel Type: CEWP.
PANEL TYPE 2. Select Wiring System Diagram
WIRING SYSTEM Number from page 92
(switching neutral, solid neutral
PANEL SIZE
or without neutral).
QTY OF BREAKERS
AMPERE RATING 3. Select Panelboard Size:
QTY OF BREAKERS A (max. 12 single-pole spaces),
AMPERE RATING B (max. 24 single-pole spaces) or
QTY OF BREAKERS
C (max. 36 single-pole spaces).
AMPERE RATING 4. Insert dash and select Breakers as
QTY OF BREAKERS desired in panelboard. First number
is quantity of breakers (1 5-60A for
AMPERE RATING
1P and 15-100A for 2P, 3P); second
NUMBER OF POLES (include only if different from wiring system) number, ampere rating (continuous);
MAIN BREAKER (number of poles depends on wiring system) and third number, number of poles.
AMPERE RATING (Indicate only if different from wiring
diagram selected). Each breaker pole
Selection Table1 takes one space.
Number Main Wiring Wiring 5. Add dash and repeat step 4 for
of Lug Cable Panel Approx. System No. 4 System No. 5 Additional Breakers as desired.
Breakers Amp. Max. Range Size Wt. (lbs.) 120/240V AC 120/208V AC 6. Add dash preceding each DV, GNL
6 250 250 MCM to 6 A 150 CEWP4A-6 CEWP5A-6 or MB suffix (see “Factory Installed
8 250 250 MCM to 6 A 150 CEWP4A-8 CEWP5A-8 Accessories”). The correct number
10 250 250 MCM to 6 A 150 CEWP4A-10 CEWP5A-10 of poles for the Main Breaker will be
12 250 250 MCM to 6 A 150 CEWP4A-12 CEWP5A-12 supplied automatically, depending on
14 250 250 MCM to 6 B 170 CEWP4B-14 CEWP5B-14 wiring system diagram selected. Maxi-
16 250 250 MCM to 6 B 170 CEWP4B-16 CEWP5B-16 mum of two main breakers allowed by
18 250 250 MCM to 6 B 170 CEWP4B-18 CEWP5B-18 NEC 384-16(a).
20 250 250 MCM to 6 B 170 CEWP4B-20 CEWP5B-20
Note: Main breakers use 2 or 3 branch circuit
22 250 250 MCM to 6 B 170 CEWP4B-22 CEWP5B-22
spaces.
24 250 250 MCM to 6 B 170 CEWP4B-24 CEWP5B-24
26 250 250 MCM to 6 C 190 CEWP4C-26 CEWP5C-26
28 250 250 MCM to 6 C 190 CEWP4C-28 CEWP5C-28
30 250 250 MCM to 6 C 190 CEWP4C-30 CEWP5C-30
Options and
32 250 250 MCM to 6 C 190 CEWP4C-32 CEWP5C-32 Factory Installed Accessories
34 250 250 MCM to 6 C 190 CEWP4C-34 CEWP5C-34
36 250 250 MCM to 6 C 190 CEWP4C-36 CEWP5C-36 Description Suffix
1
Catalog numbers shown are panelboards with single-pole breakers for wiring systems 4 and 5. To Drain and Breather -DV
order 1-, 2- and/or 3-pole breakers with different wiring systems (page 92), use “Ordering Information” Grounded Neutral Bar -GNL
above. Add ampere rating (continuous): 15 through 60 for 1P, and 15 through 100 for 2P and 3P.
Main Breaker -MB3
Ground Fault Interrupter -GFI2
(Single or Two Pole -5 mA sensitivity)
“A” Board
(12 Circuit) Equipment Protection Devices -EPD2
(Single or Two Pole -30 mA sensitivity)

Ground Terminal Bar -GJ2


“B” Board “C” Board HID rated breaker -HID
(24 Circuit) (36 Circuit) No Top Entry -NTE
*** Add ampere rating (max. 100A.)
** Consult factory.

Visit our website at www.egs-curlee.com or


90 contact Technical Services at (800) 631-6815 with any questions.
Panelboards 7
CD2P and CEWP Series Panelboards
Dimensions

CD2P shown. CD2P and CEWP have same


dimensions.

Top View

Bottom View

Side View

Visit our website at www.egs-curlee.com or


contact Technical Services at (800) 631-6815 with any questions. 91
7 Panelboards

CEWP and CD2P Series Panelboards


Wiring System Diagrams

SYSTEM NO. 1 SYSTEM NO. 2 SYSTEM NO. 3 SYSTEM NO. 4 SYSTEM NO. 5
Mains—2-Wire Mains—3 Wire Mains—3-Wire Mains—3-Wire Mains—4-Wire, 3-Phase
Branches—2-Wire Branches—2-Wire Branches—3-Wire Branches—2-Wire Branches—2-Wire, 1-Phase
Breakers—2-Pole Breakers—2-Pole Breakers—2-Pole Breakers—Single-Pole Breakers—Single-Pole
Solid Neutral Solid Neutral Solid Neutral

SYSTEM NO. 6 SYSTEM NO. 7 SYSTEM NO. 8 SYSTEM NO. 9 SYSTEM NO. 11
Mains—3-Wire Mains—2 Wire Mains—4-Wire, 3-Phase Mains—3-Wire, 3-Phase Mains—4-Wire, 3-Phase
Branches—3-Wire Branches—2-Wire Branches—3-Wire, 1-Phase Branches—2-Wire, 1-Phase Branches—4-Wire, 3-Phase
Breakers—3-Pole Breakers—Single-Pole Breakers—2-Pole Breakers—2-Pole Breakers—3-Pole
Solid Neutral Solid Neutral Solid Neutral

SYSTEM NO. 12 SYSTEM NO. 13 SYSTEM NO. 15 SYSTEM NO. 16 SYSTEM NO. 17
Mains—3-Wire, 3-Phase Mains—4 Wire, 3-Phase Mains—4-Wire, 3-Phase Mains—3-Wire Mains—3-Wire
Branches—3-Wire, 3-Phase Branches—2-Wire, 1-Phase Branches—2-Wire, 1-Phase Branches—2-Wire Branches—3-Wire
Breakers—3-Pole Breakers—2-Pole Breakers—Single-Pole Breakers—Single-Pole Breakers—3-Pole
Solid Neutral Solid Neutral

SYSTEM NO. 22 SYSTEM NO. 24 SYSTEM NO. 25 SYSTEM NO. 28 SYSTEM NO. 29
Mains—3-Wire Mains—3 Wire Mains—4-Wire, 3-Phase Mains—4-Wire, 3-Phase Mains—3-Wire, 3-Phase
Branches—2-Wire Branches—2-Wire Branches—2-Wire, 1-Phase Branches—3-Wire, 1-Phase Branches—2-Wire, 1-Phase
Breakers—2-Pole Breakers—Single-Pole Breakers—Single-Pole Breakers—2-Pole Breakers—2-Pole
Solid Neutral Solid Neutral Solid Neutral

Visit our website at www.egs-curlee.com or


92 contact Technical Services at (800) 631-6815 with any questions.
Panelboards 7
CLPN, CPPN and CGPN Series
Non-Factory Sealed Panelboards

Applications
• Distribution panelboards are used to furnish protection
and control of electrical equipment in hazardous locations.
These compact units provide a centrally controlled switch-
ing system for large quantities of branch circuits for lighting,
heating, small motors, and similar electrical equipment.

Features
• Breaker operators included as standard.
• O-ring gasket insures watertight integrity.
• Stainless steel hinges are standard.
• Copper bus bars are standard.
• Quad-Lead stainless steel cover bolts are standard.
• Permits selection of 1,2 or 3 pole breakers.
• Precision machined flame path between body and cover.
• Slotted mounting feet.
• Breaker operators can be padlocked in the “On” or “Off”
position.
• All panelboards are supplied with Cutler-Hammer1 interiors.
• Chassis assembles with mains at top (bottom optional).
• For standard outlets, see outline dimensions. For custom
outlets, consult factory.
• Provisions for 12, 18, 24, 30, 36 & 42 circuit single pole
chassis.
• 100 Amp or 225 Amp main lug.
• Up to 100 Amp backfed main breaker available with main
lug chassis.
• Up to 225 Amp main breaker available with main breaker
chassis.
• Factory installed ground and neutral bar as standard.

Standard Materials
• Bodies and covers: Copper-free aluminum.
• Cover bolts: Quad-Lead stainless steel.
• Breaker Operators: copper-free aluminum.
• Hinges: stainless steel.
• O-Ring: Neoprene.

Standard Finishes
• Corrosion resistant grey epoxy powder coat to provide
NEMA 4X rating.

Compliances
• UL Standard 1203 and 1604.
• CSA Certified - Standard C22.2, Nos 29, 30.
• NEMA 4, 4X, 7BCD, 9EFG.
1
Cutler-Hammer® is a trademark of the Eaton Corporation.

Visit our website at www.egs-curlee.com or


contact Technical Services at (800) 631-6815 with any questions. 93
7 Panelboards

CLPN Series Lighting Distribution Panelboards Class I, Div. 1 & 2 Groups B, C, D


Class II, Div. 1 & 2 Groups E,F,G
Non-Factory Sealed Class III NEMA 4, 4X, 7BCD, 9EFG

Sample Catalog Number Typical Panelboard


C LPN A12 A12 M1 ▲ Wiring Diagram
BRANCH CIRCUITS (See footnote)
MAIN TYPE: M1 = 100A Frame
M2 = 225A Frame
ML = Main Lug Only
NUMBER OF CIRCUITS:
12, 18, 24, 30, 36 & 42
WIRE SYSTEM: A = 1P 3W
C = 3P 4W
VOLTAGE: 1 = 120/240V
2 = 120/208V Single Phase, 3-Wire Systems
CURRENT RATING: 1 = 100A
2 = 225A
PANEL SIZE: A = 161606
B = 162206
C = 162806
D = 153707
F = 184207
DUTY: Non-Factory Sealed Three-Phase, 4-Wire Systems
Lighting Panel
CURLEE

Selection Table Factory Installed Options


Number 120/240V 120/208V Approx. Description Suffix
of 1 Phase 3 Wire 3 Phase 4 Wire Panel Weight
Breather, NEMA 4X, 7 & 9 -BR
Circuits BAB Type BAB Type Size (lbs)
Drain, NEMA 4X, 7 & 9 -DN
12 CLPNA11A12ML▲ CLPNA12C12ML▲ A 135 5ma Ground Fault Interrupter -GFI*
100 Amp 18 CLPNB11A18ML▲ CLPNB12C18ML▲ B 165 30ma Ground Fault Interrupter -EPD*
Main Lug Only 24 CLPNC11A24ML▲ CLPNC12C24ML▲ C 210 GFI Indicating Light -L5
30 CLPNC11A30ML▲ CLPNC12C30ML▲ C 215 Phenolic Nameplate -NP
(Specify Legend)
18 CLPNC21A18ML▲ CLPNC22C18ML▲ C 180
24 CLPNC21A24ML▲ CLPNC22C24ML▲ C 230 * GFI Push-to-Test Buttons are
225 Amp 30 CLPNC21A30ML▲ CLPNC22C30ML▲ C 235 standard with GFI or EPD options.

Main Lug Only 36 CLPND21A36ML▲ CLPND22C36ML▲ D 290


42 CLPND21A42ML▲ CLPND22C42ML▲ D 295

12 CLPNC11A12M1▲ CLPNC12C12M1▲ C 165


▲ Select branch breakers as desired in panel.
Main Breaker 18 CLPNC11A18M1▲ CLPNC12C18M1▲ C 180 First and second digits are the quantity of
100AF 24 CLPND11A24M1▲ CLPND12C24M1▲ D 295 breakers, third and fourth digits are ampere
rating, the fifth digit is number of poles.
30 CLPND11A30M1▲ CLPND12C30M1▲ D 315

18 CLPNC21A18M2▲ CLPNC22C18M2▲ C 185 Example: An 18 circuit 120/240V 1 phase 3


wire 100A MLO panel with 12 single pole 20
24 CLPND21A24M2▲ CLPND22C24M2▲ D 295 amp and 3 two pole 30 amp branch breakers
Main Breaker 30 CLPND21A30M2▲ CLPND22C30M2▲ D 300 should read CLPNB11A18ML-12201-03302.
225AF 36 CLPND21A36M2▲ CLPND22C36M2▲ D 305
42 CLPNF21A42M2▲ CLPNF22C42M2▲ F 345
Note: For Back Fed main, replace ML, M1, or M2 in part number with BF. For 400A Main Lug,
consult factory. Standard interrupting capacity is 10,000 AIC. For higher interrupt ratings, consult
factory.

Visit our website at www.egs-curlee.com or


94 contact Technical Services at (800) 631-6815 with any questions.
Panelboards 7
CPPN Series Power Distribution Panelboards Class I, Div. 1 & 2 Groups B, C, D
Class II, Div. 1 & 2 Groups E, F, G
Non-Factory Sealed Class III NEMA 4, 4X, 7BCD, 9EFG

Sample Catalog Number Typical Panelboard


C PPN A13 B12 M1 ▲ Wiring Diagram
BRANCH CIRCUITS (See footnote)
MAIN TYPE: M1 = 100A Frame
M2 = 225A Frame
ML = Main Lug Only
NUMBER OF CIRCUITS: 12, 18, 24, 30, 36 & 42
WIRE SYSTEM: B = 3P 3W
C = 3P 4W
VOLTAGE: 3 = 480V
4 = 277/480V (3P 4W Only)
Three-Phase, 4-Wire Systems
CURRENT RATING: 1 = 100A
2 = 225A
PANEL SIZE: A = 161606
B = 162206
C = 162806
D = 153707
F = 184207
DUTY: PPN: Non-Factory Sealed Power Panel
CURLEE

Selection Table Factory Installed Options


277/480V Approx. Description Suffix
No. of 3 Phase 4 Wire Panel Weight
Circuits GHB Type Size (lbs) Breather, NEMA 4X, 7 & 9 -BR
Drain, NEMA 4X, 7 & 9 -DN
12 CPPNA14C12ML▲ A 135
Phenolic Nameplate -NP
100 Amp 18 CPPNB14C18ML▲ B 165 (Specify Legend)
Main Lug Only 24 CPPNC14C24ML▲ C 210
30 CPPNC14C30ML▲ C 215
▲ Select branch breakers as desired in panel.
18 CPPNC24C18ML▲ C 180
First and second digits are the quantity of
24 CPPNC24C24ML▲ C 230 breakers, third and fourth digits are ampere
225 Amp 30 CPPNC24C30ML▲ C 235 rating, the fifth digit is number of poles.
Main Lug Only 36 CPPND24C36ML▲ D 290
Example: An 18 circuit 277/480V 1 phase 3
42 CPPND24C42ML▲ D 295
wire 100A MLO panel with 12 single pole 20
amp and 3 two pole 30 amp branch breakers
12 CPPNC14C12M1▲ C 165
should read CPPNB14C18ML-12201-03302.
Main Breaker 18 CPPNC14C18M1▲ C 180
100AF 24 CPPND14C24M1▲ D 295
30 CPPND14C30M1▲ D 315

18 CPPNC24C18M2▲ C 185
24 CPPND24C24M2▲ D 295
Main Breaker 30 CPPND24C30M2▲ D 300
225AF 36 CPPND24C36M2▲ D 305
42 CPPNF24C42M2▲ F 345

Note: For Back Fed main, replace ML, M1, or M2 in part number with BF. For 400A Main Lug,
consult factory. Standard interrupting capacity is 14,000 AIC. For higher interrupt ratings, consult
factory.

Visit our website at www.egs-curlee.com or


contact Technical Services at (800) 631-6815 with any questions. 95
7 Panelboards

CPPN Series Power Distribution Panelboards Class I, Div. 1 & 2 Groups B, C, D


Class II, Div. 1 & 2 Groups E, F, G
Non-Factory Sealed Class III NEMA 4, 4X, 7BCD, 9EFG

Sample Catalog Number Typical Panelboard


C PPN E13 B12 M1 ▲ Wiring Diagram
BRANCH CIRCUITS (See footnote)
MAIN TYPE: M1 = 100A Frame
M2 = 225A Frame
ML = Main Lug Only
NUMBER OF CIRCUITS: 12, 18, 24, 30, 36 & 42
WIRE SYSTEM: B = 3P 3W
C = 3P 4W
VOLTAGE: 3 = 480V Three Phase, 3-Wire Systems
4 = 277/480V (3P 4W Only)
6 = 600V
CURRENT RATING: 1 = 100A
2 = 225A
PANEL SIZE: E = 183608
G = 184806
H = 206008
DUTY: PPN: Non-Factory Sealed Power Panel
CURLEE

Three-Phase, 4-Wire Systems

Selection Table
480V 277/480V 600V Approx. Factory Installed Options
No. of 3 Phase 3 Wire 3 Phase 4 Wire 3 Phase 4 Wire Panel Weight
Circuits EHD Type EHD Type FDB Type Size (lbs) Description Suffix

12 CPPNE13B12ML▲ CPPNE14C12ML▲ CPPNE16C12ML▲ E 280 Breather, NEMA 4X, 7 & 9 -BR


100 Amp 18 CPPNE13B18ML▲ CPPNE14C18ML▲ CPPNE16C18ML▲ E 285 Drain, NEMA 4X, 7 & 9 -DN
Main Lug 24 CPPNE13B24ML▲ CPPNE14C24ML▲ CPPNE16C24ML▲ E 290 Phenolic Nameplate -NP
Only 30 CPPNG13B30ML▲ CPPNG14C30ML▲ CPPNG16C30ML▲ G 385 (Specify Legend)

18 CPPNE23B18ML▲ CPPNE24C18ML▲ CPPNE26C18ML▲ E 290


225 Amp 24 CPPNG23B24ML▲ CPPNG24C24ML▲ CPPNG26C24ML▲ G 390
Main Lug 30 CPPNG23B30ML▲ CPPNG24C30ML▲ CPPNG26C30ML▲ G 395 ▲ Select branch breakers as desired in panel.
Only 36 CPPNG23B36ML▲ CPPNG24C36ML▲ CPPNG26C36ML▲ G 400 First and second digits are the quantity of
breakers, third and fourth digits are ampere rat-
42 CPPNH23B42ML▲ CPPNH24C42ML▲ CPPNH26C42ML▲ H 545 ing, the fifth digit is number of poles.
Main 12 CPPNE13B12M1▲ CPPNE14C12M1▲ CPPNE16C12M1▲ E 285 Example: An 18 circuit 277/480V 3 phase 4
Breaker 18 CPPNG13B18M1▲ CPPNG14C18M1▲ CPPNG16C18M1▲ G 390 wire 100A MLO panel with 12 single pole 20
100AF 24 CPPNG13B24M1▲ CPPNG14C24M1▲ CPPNG16C24M1▲ G 395 amp and 3 two pole 30 amp branch breakers
should read CPPNE14C18ML-12201-03302.
30 CPPNG13B30M1▲ CPPNG14C30M1▲ CPPNG16C30M1▲ G 400

18 CPPNG23B18M2▲ CPPNG24C18M2▲ CPPNG26C18M2▲ G 395


Main 24 CPPNG23B24M2▲ CPPNG24C24M2▲ CPPNG26C24M2▲ G 400
Breaker 30 CPPNH23B30M2▲ CPPNH24C30M2▲ CPPNH26C30M2▲ H 550
225AF 36 CPPNH23B36M2▲ CPPNH24C36M2▲ CPPNH26C36M2▲ H 555
42 CPPNH23B42M2▲ CPPNH24C42M2▲ CPPNH26C42M2▲ H 560

Note: For Back Fed main, replace ML, M1 or M2 in part number with BF. For 400A Main Lug,
consult factory. Standard interrupting capacity is 14,000 AIC. For higher interrupt ratings, consult
factory.

Visit our website at www.egs-curlee.com or


96 contact Technical Services at (800) 631-6815 with any questions.
Panelboards 7
CLPN, CPPN Main Lug Panelboard
Dimensional Data & Mounting Hardware

Panel A Panel B Panel C

Mounting Dimensions

Panel Standard Outlets Mounting


Size A B C D E F1 F2 G H K Top Bottom Hdw. Set

A 11.00 19.75 21.00 21.00 11.00 2.75 5.13 — 4.00 3.94 (1) 2” (6) 1” AMH8
B 13.00 25.25 21.44 27.31 11.00 2.75 5.13 — 4.00 3.94 (1) 2” (6) 1” AMH8
C 13.00 30.75 20.75 32.75 11.00 2.75 5.13 2.00 4.00 3.94 (1) 3” (8) 1” AMH8

All dimensions are in inches. All outlets are NPT.

Visit our website at www.egs-curlee.com or


contact Technical Services at (800) 631-6815 with any questions. 97
7 Panelboards

CLPN, CPPN Main Lug Panelboard


Dimensional Data & Mounting Hardware

Panel D Panel E Panel G Panel H


(Front View (Front View) (Front View) (Front View)

Panel D
(End View)

Panel E
(End View)

Panel G
(End View)

Panel H
(End View)

Mounting Dimensions

Panel Standard Outlets Mounting


Size A B C D E F1 F2 G H J K Top Bottom Hdw. Set

D 13.75 41.63 21.00 42.94 13.00 3.56 5.94 2.00 4.00 — 4.75 (1) 3” (8) 1” CMH8
E 21.75 29.00 23.50 42.94 13.63 3.56 5.94 2.00 4.00 — 4.75 (1) 3” (8) 1” CMH8
G 21.38 36.00 23.00 53.00 11.00 2.50 4.88 1.19 2.38 2.38 3.50 (1) 3” (12) 1” CMH6
H 23.50 50.00 25.00 65.00 14.00 3.44 5.94 1.25 2.50 2.50 4.69 (1) 3” (12) 1” CMH6

All dimensions are in inches. All outlets are NPT.

Visit our website at www.egs-curlee.com or


98 contact Technical Services at (800) 631-6815 with any questions.
Panelboards 7
CLPN, CPPN Main Breakers Panelboard
Dimensional Data & Mounting Hardware

Panel C Panel D Panel E

Mounting Dimensions

Panel Standard Outlets Mounting


Size A B C D E F1 F2 G H K Top Bottom Hdw. Set

C 13.00 30.75 20.75 32.75 11.00 2.75 5.13 2.00 4.00 3.94 (1) 3” (8) 1” CMH8
D 13.75 41.63 21.00 42.94 13.00 3.56 5.94 2.00 4.00 4.75 (1) 3” (8) 1” CMH8
E 21.75 29.00 23.50 41.75 13.63 3.56 5.94 2.00 4.00 4.75 (1) 3” (8) 1” CMH8

All dimensions are in inches. All outlets are NPT.

Visit our website at www.egs-curlee.com or


contact Technical Services at (800) 631-6815 with any questions. 99
7 Panelboards

CLPN, CPPN Main Breakers Panelboard


Dimensional Data and Mounting Hardware

Panel F Panel G Panel H

(2) 1/2” NPT


FOR B/D

Mounting Dimensions

Panel Standard Outlets Mounting


Size A B C D E F1 F2 G H J K Top Bottom Hdw. Set

F 16.00 45.38 23.75 47.75 12.81 3.69 6.31 1.25 2.50 2.50 5.00 (1) 3” (12) 1” CMH8
G 21.38 36.00 23.00 53.00 11.00 2.50 4.88 1.19 2.38 2.38 3.50 (1) 3” (12) 1” CMH6
H 23.50 50.00 25.00 65.00 14.00 3.44 5.94 1.25 2.50 2.50 4.69 (1) 3” (12) 1” CMH6

All dimensions are in inches. All outlets are NPT.

Visit our website at www.egs-curlee.com or


100 contact Technical Services at (800) 631-6815 with any questions.
Panelboards 7
CGPN Series Ground Fault Interrupting
Distribution Panelboards
Non-Factory Sealed

Sample Catalog Number Typical Panelboard


Wiring Diagram
C GPN A12 412 ML ▲
BRANCH CIRCUITS (See footnote) Single Phase, 3-Wire Systems
MAIN TYPE: ML = Main Lug Only
NUMBER OF CIRCUITS: 4, 6, 12, 18, 24
WIRE SYSTEM: A = 1P 3W
C = 3P 4W
VOLTAGE: 1 = 120/240V
2 = 120/208V
CURRENT RATING: 1 = 100A
PANEL SIZE: AA = 091105
A = 161606
B = 162206
C = 162806
DUTY: GPN: Non-Factory Sealed GFI Panel
CURLEE
Three-Phase, 4-Wire Systems

Selection Table
Approx.
No. of 120/240V 120/208V Panel Weight
Circuits 1 Phase 3 Wire 3 Phase 4 Wire Size (lbs)

4 CGPNA11A04ML▲ CGPNA12C04ML▲ AA 30
100 Amp 6 CGPNA11A06ML▲ CGPNA12C06ML▲ AA 35
Main Lug Only 12 CGPNA11A12ML▲ CGPNA12C12ML▲ A 135
18 CGPNB11A18ML▲ CGPNB12C18ML▲ B 165
24 CGPNC11A24ML▲ CGPNC12C24ML▲ C 210

Note: For Back Fed main, replace last ML in part number with BF. For 100A Main Breaker,
consult factory. Standard interrupting capacity is 10,000 AIC. For higher interrupt ratings,
consult factory. Factory Installed Options

▲ Select branch breakers as desired in panel. First and second digits are the quantity of break- Description Suffix
ers, third and fourth digits are ampere rating, the fifth digit is number of poles.
Breather, NEMA 4X, 7 & 9 -BR
Example: An 18 circuit 120/240V 1 phase 3 wire 100A MLO panel with 12 single pole 20 amp Drain, NEMA 4X, 7 & 9 -DN
30 ma GFI and 3 two pole 30 amp 5 ma GFI branch breakers should read CGPNB11A18ML-
5ma Ground Fault Interrupter -GFI*
12201EPD-03302GFI.
30ma Ground Fault Interrupter -EPD*
GFI Indicating Light -L5
Phenolic Nameplate -NP
(Specify Legend)

* GFI Push-to-Test Buttons are standard


with GFI or EPD options.

Visit our website at www.egs-curlee.com or


contact Technical Services at (800) 631-6815 with any questions. 101
7 Panelboards

CGPN Series GFI Panelboard


Dimensional Data & Mounting Hardware

Panel AA Panel A Panel B Panel C

Mounting Dimensions

Panel Standard Outlets Mounting


Size A B C D E F1 F2 G H K Top Bottom Hdw. Set

AA 7.25 13.13 13.88 15.50 9.56 2.38 — 1.06 2.13 2.38 (1) 1” (4) 3/4” CMH2
A 11.00 19.75 21.00 21.00 11.00 2.75 5.13 — 4.00 3.94 (1) 2” (6) 1” CMH8
B 13.00 25.25 21.44 27.31 11.00 2.75 5.13 — 4.00 3.94 (1) 2” (6) 1” CMH8
C 13.00 30.75 20.75 32.75 11.00 2.75 5.13 2.00 4.00 3.94 (1) 3” (8) 1” CMH8
All dimensions are in inches. All outlets are NPT.

Visit our website at www.egs-curlee.com or


102 contact Technical Services at (800) 631-6815 with any questions.
Panelboards 7
Panelboard Data Sheet
Curlee Catalog Number: ___________________________

Interior Type: Enclosure Specifications:


Options
Bolted Plug-In
Breather Drain External Ground Lug
Manufacturer:
Other ________________
Square D Westinghouse / Cutler-Hammer®
Other Conduit
Catalog Bottom Feed (LB) Special
Main Breaker Frame / Trip:
Line Side Load Side
Not Required
Other Options:
_______ AF Circuit Breaker with a trip rating of
Ground Fault Relay / CT (Include Shunt Trip in Breaker)
Manufacture:
Ammeter (Qty. _______) Scale
12 Circuit 18 Circuit 24 Circuit
Ammeter Switch
30 Circuit 36 Circuit 42 Circuit
Voltmeter (Qty. _______) Scale
Voltage Rating: Voltmeter Switch

600 Volt 280/277 Volt 240/120 Volt Other

208/120 Volt NEMA 4 Handles


_____________________
A.I.C. Rating:
_____________________
RMS

Branch Breakers: Nameplate


(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp Enclosure Nameplate
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp Individual Circuit Nameplate (1” x 3”)
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp Size _______ ” x _______ ”
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp Character Height: _________
(_______ ) Pole _______ Amp Color: White Background with Black Lettering.
Attached with Stainless Steel Screws.
Control Devices:
Space Heater _______ Volt Operated, Rated _______
Thermostat
Hand Off Auto Switch
120 Volt Screw-In Receptacle (Installed in Cover)
Pilot Light Qty. (_______)
Wire Sizes (Max Lug Size):
_____________________
Line Side Wiring: (_______) per Phase
Load Side Wiring: (_______) per Phase
Ground Wire: (_______)

Visit our website at www.egs-curlee.com or


contact Technical Services at (800) 631-6815 with any questions. 103
7 Panelboards

CPPF 480, 600 Volt Factory Sealed Class I, Div. 1 & 2 Groups B*, C*, D
Class II, Div. 1 & 2 Groups E, F, G
Power Distribution Panelboards Class III NEMA 4, 4X, 7BCD, 9EFG

Applications
• Distribution panelboards are used to furnish protection
and control of electrical equipment in hazardous locations.
These compact units provide a centrally controlled
switching system for large quantities of branch circuits
for lighting, heating, small motors, and similar electrical
equipment.

Features
• Breaker operators included as standard.
• O-ring gasket insures watertight integrity.
• Stainless steel hinges are standard.
• Copper bus bars are standard.
• Quad-Lead stainless steel cover bolts are standard.
• Factory-sealed, no external seals are required for most
branch circuits. All conduits must be sealed adjacent to
enclosure for Class I, Div. 1, Groups B and C.
• Breakers are housed in the panel section and prewired
to maximum circuit capacity, then wired to numbered
terminals in the wiring compartment.
• Terminal compartment is interconnected to panel section
with sealing hubs, unions and poured with sealing
compound.
• Permits selection of 1, 2 or 3 pole breakers.
• Precision machined flame path between body and cover.
• Bolt on stainless steel slotted mounting feet.
• Breaker operators can be padlocked in the “On” or “Off”
position.
• All panelboards are supplied with Cutler-Hammer®1
interiors.
• Chassis assembles with mains at top (bottom optional). Standard Materials
• Provisions for 12, 18, 24, 30, 36 and 42 circuit single Bodies and covers: copper-free aluminum.

pole chassis.
• Cover bolts: Quad-Lead stainless steel.
• 100 Amp or 225 Amp main lug.
• Breaker Operators: copper-free aluminum.
• Up to 100 Amp backfed main breaker available with main
• Hinges: stainless steel.
lug chassis.
• O-Ring: neoprene.
• Up to 225 amp main breaker available with main breaker
chassis.
Factory installed ground and neutral bar as standard. Standard Finish

• Corrosion resistant grey epoxy powder coat to provide
NEMA 4X rating.
1
Cutler-Hammer® is a trademark of the Eaton Corporation.
* For Class I, Div. 1, Groups B and C, all conduits must be sealed adjacent
Compliances
to enclosure.
• UL Classified - Standard 1203 and 1604.
• CSA Certified - Standard C22.2, Nos. 29, 30.
• NEMA 4,4X,7BCD,9EFG.

Visit our website at www.egs-curlee.com or


104 contact Technical Services at (800) 631-6815 with any questions.
Panelboards 7
CPPF 480, 600V Volt Factory Sealed Class I, Div. 1 & 2 Groups B*, C*, D
Class I, Zone 1 & 2 Groups IIA,
Power Distribution Panelboards IIB*+H2*
Class II, Div. 1 & 2 Groups E, F, G
Class III NEMA 4, 4X, 7B*C*D, 9EFG

Sample Catalog Number Typical Panelboard Wiring Diagram


C PPF P13 B12 M1 ▲
BRANCH CIRCUITS (See footnote)
MAIN TYPE:M1 = 100A Frame
M2 = 225A Frame
ML = Main Lug Only
NUMBER OF CIRCUITS: 12, 18, 24,
30, 36 & 42
WIRE SYSTEM: B = 3P 3W
C = 3P 4W
Three Phase, 3-Wire Systems
VOLTAGE: 3 = 480V
4 = 277/480V (3P 4W Only)
6 = 600V
CURRENT RATING: 1 = 100A
2 = 225A
PANEL SIZE: P
R
S
DUTY: PPF: Factory Sealed
Power Panel
CURLEE Three-Phase, 4-Wire Systems

Selection Table
480V 277/480V 277/480V 600V
No. of 3 Phase 3 Wire 3 Phase 4 Wire 3 Phase 4 Wire 3 Phase 4 Wire
Circuits EHD Type EHD Type GHB Type FDB Type
12 CPPFP13B12ML▲ CPPFP14C12ML▲ CPPFP16C12ML▲
100 Amp 18 CPPFP13B18ML▲ CPPFP14C18ML▲ CPPFP16C18ML▲
Main Lug 24 CPPFP13B24ML▲ CPPFP14C24ML▲ CPPFP16C24ML▲
Only 30 CPPFR13B30ML▲ CPPFR14C30ML▲ CPPFR16C30ML▲
18 CPPFP23B18ML▲ CPPFP24C18ML▲ CPPFP26C18ML▲
225 Amp 24 CPPFR23B24ML▲ CPPFR24C24ML▲ CPPFR26C24ML▲
Main Lug 30 CPPFR23B30ML▲ CPPFR24C30ML▲ CPPFR26C30ML▲
Only 36 CPPFR23B36ML▲ CPPFR24C36ML▲ CPPFR26C36ML▲
42 CPPFS23B42ML▲ CPPFS24C42ML▲ CPPFS26C42ML▲
Main 12 CPPFP13B12M1▲ CPPFP14C12M1▲ CPPFP16C12M1▲
Breaker 18 CPPFR13B18M1▲ CPPFR14C18M1▲ CPPFR16C18M1▲
100AF 24 CPPFR13B24M1▲ CPPFR14C24M1▲ CPPFR16C24M1▲
30 CPPFR13B30M1▲ CPPFR14C30M1▲ CPPFR16C30M1▲
18 CPPFR23B18M2▲ CPPFR24C18M2▲ CPPFR26C18M2▲
Main 24 CPPFR23B24M2▲ CPPFR24C24M2▲ CPPFR26C24M2▲
Breaker 30 CPPFS23B30M2▲ CPPFS24C30M2▲ CPPFS26C30M2▲
225AF 36 CPPFS23B36M2▲ CPPFS24C36M2▲ CPPFS26C36M2▲
42 CPPFS23B42M2▲ CPPFS24C42M2▲ CPPFS26C42M2▲

Note: For Back Fed main, replace ML, M1, or M2 in part number with BF. For 400A Main Lug, consult factory. Standard interrupting capacity is
14,000 AIC. For higher interrupt ratings, consult factory.
▲ Select branch breakers as desired in panel. First and second digits are the quantity of breakers, third and fourth digits are ampere rating, the fifth
digit is number of poles. Example: An 18 circuit 277/480V 3 phase 4 wire 100A MLO panel with 12 single pole 20 amp and 3 two pole 30 amp branch
breakers should read CPPFP14C18ML-12201-03302.
* For Class I, Div. 1, Groups B and C, all conduits must be sealed WITHIN 2” of enclosure.

Visit our website at www.egs-curlee.com or


contact Technical Services at (800) 631-6815 with any questions. 105
7 Panelboards

CPPF 480, 600V Volt Factory Sealed


Power Distribution Panelboards
Options, Dimensional Data and Mounting Hardware

Factory Installed Options


Description Suffix Panel Sealed Together

Breather, NEMA 4X -BR P 183608 181806/08


Drain, NEMA 4X -DN R 184806 181806/08
External Ground Stud -EGS S 206008 181806/08
Phenolic Nameplate -NP
(Specify Legend)
Panel Standard Outlets Mounting
Size Top Sides Hdw. Set
P (1) 3” & (8) 1”NPT (2) MH8
R (1) 3” & (8) 1”NPT (4) 1” NPT (2) MH8
S (1) 3” & (8) 1”NPT (4) 1” NPT (2) MH8
Mounting Dimensions

Panel
Size A1 A2 B1 B2 C1 C2 D1 D2 E F1 F2 F3 G H K M
P 21.75 21.75 13.00 29.00 23.38 23.50 23.38 41.75 67.63 2.94 5.13 4.00 3.50 4.13 13.06
R 21.75 21.38 13.00 36.00 23.38 23.00 23.38 53.00 78.88 2.94 5.13 7.50 4.00 3.50 4.13 10.50
S 21.75 23.50 13.00 50.00 23.38 25.00 23.38 65.00 91.00 2.94 5.13 7.50 4.00 3.50 4.13 13.50

CPPFP CPPFR CPPFS

Visit our website at www.egs-curlee.com or


106 contact Technical Services at (800) 631-6815 with any questions.
Panelboards 7
Panelboard Data Sheet
Curlee Catalog Number: ___________________________

Interior Type: Enclosure Specifications:


Options
Bolted Plug-In
Breather Drain External Ground Lug
Manufacturer:
Other ________________
Square D Westinghouse / Cutler-Hammer®
Other Conduit
Catalog Bottom Feed (LB) Special
Main Breaker Frame / Trip:
Line Side Load Side
Not Required
Other Options:
_______ AF Circuit Breaker with a trip rating of
Ground Fault Relay / CT (Include Shunt Trip in Breaker)
Manufacture:
Ammeter (Qty. _______) Scale
12 Circuit 18 Circuit 24 Circuit
Ammeter Switch
30 Circuit 36 Circuit 42 Circuit
Voltmeter (Qty. _______) Scale
Voltage Rating: Voltmeter Switch

600 Volt 280/277 Volt 240/120 Volt Other

208/120 Volt NEMA 4 Handles


_____________________
A.I.C. Rating:
_____________________
RMS

Branch Breakers: Nameplate


(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp Enclosure Nameplate
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp Individual Circuit Nameplate (1” x 3”)
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp Size _______ ” x _______ ”
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp Character Height: _________
(_______ ) Pole _______ Amp Color: White Background with Black Lettering.
Attached with Stainless Steel Screws.
Control Devices:
Space Heater _______ Volt Operated, Rated _______
Thermostat
Hand Off Auto Switch
120 Volt Screw-In Receptacle (Installed in Cover)
Pilot Light Qty. (_______)
Wire Sizes (Max Lug Size):
_____________________
Line Side Wiring: (_______) per Phase
Load Side Wiring: (_______) per Phase
Ground Wire: (_______)

Visit our website at www.egs-curlee.com or


contact Technical Services at (800) 631-6815 with any questions. 107
7 Panelboards

CLPF Factory Sealed Lighting Class I, Div. 1 & 2 Groups B*, C*, D
Class II, Div. 1 & 2 Groups E, F, G
Distribution Panelboards Class III NEMA 4, 4X, 7BCD, 9EFG

Applications
• Distribution panelboards are used to furnish protection
and control of electrical equipment in hazardous locations.
These compact units provide a centrally controlled
switching system for large quantities of branch circuits
for lighting, heating, small motors, and similar electrical
equipment.

Features
• Breaker operators included as standard.
• O-ring gasket insures watertight integrity.
• Stainless steel hinges are standard.
• Copper bus bars are standard.
• Quad-Lead stainless steel cover bolts are standard.
• Factory-sealed, no external seals are required for most
branch circuits. All conduits must be sealed adjacent to
enclosure for Class I, Div. 1, Groups B and C.
• Breakers are housed in the panel section and prewired
to maximum circuit capacity, then wired to numbered
terminals in the wiring compartment.
• Terminal compartment is interconnected to panel section
with sealing hubs, unions and poured with sealing
compound.
• Permits selection of 1, 2 or 3 pole breakers.
• Precision machined flame path between body and cover.
• Bolt on stainless steel slotted mounting feet.
• Breaker operators can be padlocked in the “On” or “Off”
position.
• All panelboards are supplied with Cutler-Hammer®1
interiors.
• Chassis assembles with mains at top (bottom optional).
• Provisions for 12, 18, 24, 30, 36 and 42 circuit single Standard Finish
pole chassis.
• Corrosion resistant grey epoxy powder coat to provide
• 100 Amp or 225A main lug. NEMA 4X rating.
• Up to 100 Amp backfed main breaker available with
main lug chassis. Compliances
• Up to 225 amp main breaker available with main
breaker chassis. • UL Classified - Standard 1203 and 1604.
Factory installed ground and neutral bar as standard. • CSA Certified - Standard C22.2, Nos. 29, 30.

• NEMA 4,4X,7BCD,9EFG.
Standard Materials
1
Cutler-Hammer is a trademark of the Eaton Corporation.
• Bodies and covers: copper-free aluminum.
* For Class I, Div. 1, Groups B and C, all conduits must be sealed
• Cover bolts: Quad-Lead stainless steel.
adjacent to enclosure.
• Breaker Operators: copper-free aluminum.
• Hinges: stainless steel.
• O-Ring: neoprene.

Visit our website at www.egs-curlee.com or


108 contact Technical Services at (800) 631-6815 with any questions.
Panelboards 7
CLPF Factory Sealed Lighting Class I, Div. 1 & 2 Groups B*, C*, D
Class I, Zone 1 & 2 Groups IIA, IB*+H2*
Distribution Panelboards Class II, Div. 1 & 2 Groups E, F, G
Class III NEMA 4, 4X, 7B*C*D, 9EFG

Sample Catalog Number Typical Panelboard


Wiring Diagram
C LPF P13 B12 M1 ▲
BRANCH CIRCUITS (See footnote)

MAIN TYPE: M1 = 100A Frame


M2 = 225A Frame
ML = Main Lug Only

NUMBER OF CIRCUITS:
12, 18, 24, 30, 36 & 42

WIRE SYSTEM: B = 1P 3W
C = 3P 4W
Three-Phase, 3-Wire Systems
VOLTAGE: 1 = 120/240V
2 = 120/208V
4 = 277/480V
CURRENT RATING: 1 = 100A
2 = 225A
PANEL SIZE: J , K, M, N, Q

DUTY: LPF: Factory Sealed Lighting Panel

CURLEE Single Phase, 4-Wire Systems

Selection Table
120/240V 120/208V
Factory Installed Options
No. of 1 Phase 3 Wire 3 Phase 4 Wire
Circuits BAB Type BAB Type Description Suffix

12 CLPFJ11B12ML▲ CLPFJ12C12ML▲ Breather, NEMA 4X -BR


100 Amp 18 CLPFK11B18ML▲ CLPFK12C18ML▲ Drain, NEMA 4X -DN
Main Lug 24 CLPFM11B24ML▲ CLPFM12C24ML▲ External Ground Stud -EGS
Only 30 CLPFM11B30ML▲ CLPFM12C30ML▲ Grounding Neutral Lug -GNL
Phenolic Nameplate -NP
18 CLPFM21B18ML▲ CLPFM22C18ML▲ (Specify Legend)
225 Amp 24 CLPFM21B24ML▲ CLPFM22C24ML▲
Main Lug 30 CLPFM21B30ML▲ CLPFM22C30ML▲ Panel Sealed Together
Only 36 CLPFN21B36ML▲ CLPFN22C36ML▲
42 CLPFN21B42ML▲ CLPFN22C42ML▲ J 161606 161606/08
K 162206 161606/08
Main 12 CLPFM11B12M1▲ CLPFM12C12M1▲
M 162806 161606/08
Breaker 18 CLPFM11B18M1▲ CLPFM12C18M1▲
N 153707 161606/08
100AF 24 CLPFN11B24M1▲ CLPFN12C24M1▲
30 CLPFN11B30M1▲ CLPFN12C30M1▲ Q 184207 181806/08

18 CLPFM21B18M2▲ CLPFM22C18M2▲
▲ Select branch breakers as desired in panel.
Main 24 CLPFN21B24M2▲ CLPFN22C24M2▲ First and second digits are the quantity of
Breaker 30 CLPFN21B30M2▲ CLPFN22C30M2▲ breakers, third and fourth digits are ampere
225AF 36 CLPFN21B36M2▲ CLPFN22C36M2▲ rating, the fifth digit is number of poles. Ex-
42 CLPFQ21B42M2▲ CLPFQ22C42M2▲ ample: An 18 circuit 120/240V 1 phase 3
wire 225A Main panel with 12 single pole 20
Note: For Back Fed main, replace ML, M1, or M2 in part number with BF. For 400A Main amp and 3 two pole 30 amp branch breakers
Lug, consult factory. Standard interrupting capacity is 14,000 AIC. For higher interrupt should read CLPFM21B18M2-12201-03302.
ratings, consult factory.

* For Class I, Div. 1, Groups B and C, all conduits must be sealed WITHIN 2” of enclosure.

Visit our website at www.egs-curlee.com or


contact Technical Services at (800) 631-6815 with any questions. 109
7 Panelboards

Panelboard Data Sheet


Curlee Catalog Number: ___________________________

Interior Type: Enclosure Specifications:


Options
Bolted Plug-In
Breather Drain External Ground Lug
Manufacturer:
Other ________________
Square D Westinghouse / Cutler-Hammer®
Other Conduit
Catalog Bottom Feed (LB) Special
Main Breaker Frame / Trip:
Line Side Load Side
Not Required
Other Options:
_______ AF Circuit Breaker with a trip rating of
Ground Fault Relay / CT (Include Shunt Trip in Breaker)
Manufacture:
Ammeter (Qty. _______) Scale
12 Circuit 18 Circuit 24 Circuit
Ammeter Switch
30 Circuit 36 Circuit 42 Circuit
Voltmeter (Qty. _______) Scale
Voltage Rating: Voltmeter Switch

600 Volt 280/277 Volt 240/120 Volt Other

208/120 Volt NEMA 4 Handles


_____________________
A.I.C. Rating:
_____________________
RMS

Branch Breakers: Nameplate


(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp Enclosure Nameplate
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp Individual Circuit Nameplate (1” x 3”)
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp Size _______ ” x _______ ”
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp
(_______ ) Pole _______ Amp (_______ ) Pole _______ Amp Character Height: _________
(_______ ) Pole _______ Amp Color: White Background with Black Lettering.
Attached with Stainless Steel Screws.
Control Devices:
Space Heater _______ Volt Operated, Rated _______
Thermostat
Hand Off Auto Switch
120 Volt Screw-In Receptacle (Installed in Cover)
Pilot Light Qty. (_______)
Wire Sizes (Max Lug Size):
_____________________
Line Side Wiring: (_______) per Phase
Load Side Wiring: (_______) per Phase
Ground Wire: (_______)

Visit our website at www.egs-curlee.com or


110 contact Technical Services at (800) 631-6815 with any questions.