Documente Academic
Documente Profesional
Documente Cultură
TH55
308-2996 Control Harness As
Transmission ECM Harness
(Transmission Harness, Transmission ECM Connectors, 1
As(2)(3)
Customer Connector, Service Tool Connector)
TH48-E70
320-8180
Connector Plug As
Connector Plug As(4) 9X-7147 1
(For Customer Harness Interface to Transmission ECM Harness)
163-1876 LED Lamp 1
Power Train Warning Indicator 113-5183 Lamp Socket 1
113-5184 Receptacle Terminal 1
(1) ECM mounting requires 4 M8 bolts of sufficient length for vibration isolators and for the material the ECM is mounted to. The torque for
these bolts should be 28 ± 7 N·m (21 ± 5 lb ft). See Table 4 for more information.
(2) ECM electrical connectors should be torqued to 6.25 ± 1.25 N·m (55 ± 11 lb in).
(3) Transmission Harness connector 7X-6222 Connector Plug As should be torqued to 2.25 ± 0.25 N·m (20 ± 2.2 lb in).
(4) Customer Connector 9X-7147 Connector Plug As should be torqued to 2.25 ± 0.25 N·m (20 ± 2.2 lb in).
94