Sunteți pe pagina 1din 1

Summary of final excavation stage axial force in basement slab(without EQ for all section and GF at final stage for

sec1.1-4.6 and 7.2-9.2 and GF at first stage for 5.1 to 7.1)

Full model Sections oK o13 o7 h4 oC1 sD1 h4 s2 s5 o2 o7


Half model Sections 1.1 1.2 with B1 1.2 1.3 1.4 1.5 1.6 2.1 2.2 3.1 3.2 4.1 with B1 4.1 4.2 4.3 4.4 4.5 4.6 5.1 5.2 6.1 6.2 6.3 7.1 7.2 8.1 9.1 9.2
D-wall type Type1 Type2 Type3 Type4 5A 5B 6A 6B 6C 7A 7B 8 7C 7D
Thickness of D-wall (mm) 1000 800 1000 1000 1000 1000 1000 1200 1000
Tip level of D-wall (m) -28 -28 -28 -28 -28.00 -28.00 -30.00 -33 -28
Ground floor - - - - - - - - -463 - - - - - - - - - -146.2 -36 -357 -671 -320 -146.2 0 - - -
Ramp GF to B1 - - - - - - - - - - - - - - - - 0 - - - - - - - - - - -
B1 -807 -1035 - - - - - -973.2 - -834.6 -834.6 -655 - - - - -608 -699 -868.5 -816 -530 - -604 -868.5 -800 -728 -857.7 -834.6
Force in Basement slab(kN/m)
Ramp B1 to B2 - -1 -1379 -1204 -885 -468 -299 - - - - -926 -1388 -774 -956 -677 - - - - - - - - - - - -
B2 -1028 - - - - -1531 -1495 0 -861 -849.5 -849.5 - - - - -1361 -1721 -1326 -1020.0 -1225 -462 -1483 -800 -1020.0 -1129 -1396 -835.5 -849.5
Ramp B2 to B3 0 -1198 -855 -917 -879 - - - - - - -522 -863 -1249 -992 - - - - - - - - - - - - -
B3 0 0 0 0 -65 0 0 - - 0 0 0 0 0 -34 0 0 0 0 0 - - 0 - - -324 - -

Summary of final excavation stage axial force in basement slab(without EQ for all section and GF at final stage for sec1.1-4.6 and 7.2-9.2)

Section 1.1 1.2 with B1 1.2 1.3 1.4 1.5 1.6 2.1 2.2 3.1 3.2 4.1 with B1 4.1 4.2 4.3 4.4 4.5 4.6 5.1 5.2 6.1 6.2 6.3 7.1 7.2 8.1 9.1 9.2
D-wall type Type1 Type2 Type3 Type4 5A 5B 6A 6B 6C 7A 7B 8 7C 7D
Thickness of D-wall (mm) 1000 800 1000 1000 1000 1000 1000 1200 1000
Tip level of D-wall (m) -28 -28 -28 -28 -28.00 -28.00 -30.00 -33 -28
Ground floor - - - - - - - - -463 - - - - - - - - - -59 -36 -66 -671 -141 -17 0 - - -
Ramp GF to B1 - - - - - - - - - - - - - - - - 0 - - - - - - - - - - -
B1 -508 -1035 - - - - - -1131 - -524 -624 -655 - - - - -608 -699 -709 -816 -1100 - -716 -1063 -772 -475 -687 -816
Force in Basement slab(kN/m)
Ramp B1 to B2 - -1 -1379 -1204 -885 -468 -299 - - - - -926 -1388 -774 -956 -677 - - - - - - - - - - - -
B2 -1516 - - - - -1531 -1495 0 -861 -1385 -1318 - - - - -1361 -1721 -1326 -1548 -1225 -684 -1483 -1478 -846 -960 -1931 -1283 -721
Ramp B2 to B3 0 -1198 -855 -917 -879 - - - - - - -522 -863 -1249 -992 - - - - - - - - - - - - -
B3 0 0 0 0 -65 0 0 - - 0 0 0 0 0 -34 0 0 0 0 0 - - 0 - - -325 - -

Summary of final excavation stage axial force in basement slab(without EQ for all section and GF at final stage for sec1.1-4.6 and 7.2-9.2)

Section 1.2 1.3 1.4 4.1 4.1.1 4.2 4.3 4.4


D-wall type 1B 1C 4A 4B
Thickness of D-wall (mm) 1000 1000
Tip level of D-wall (m) -28 -28
Ground floor - - - - - - - -
Ramp GF to B1 - - - - - - - -
Force in B1 -649 - - - -618 - - -
Basement Ramp B1 to B2 -936 -1410 -966 -1842 -960 -1520 -1159 -702
slab(kN/m) B2 - - - - - - - -1322
Ramp B2 to B3 -531 -652 -805 -295 -508 -669 -780 -
B3 0 0 -67 0 0 0 -55 0