RH..3 RECORD SHEET

TYPE DATE NAME SERIAL No.


RH _ _ 3 . .
TOTAL OPERATION TIME OPERATION TIME AFTER PREVIOUS OVERHAUL OVERHAUL INTERVAL

HOURS HOURS
CLEARANCE BETWEEN TURBINE ROTOR AND TURBINE HOUSING
BEFORE (mm) AFTER (mm) CHECK
R1
R1+R3 R1+R3

R2+R4 R2+R4
RH133 0.75×2=1.50
R3 RH143/163 0.70×2=1.40
INITIAL
RH183/203 0.90×2=1.80
VALUE
R4 R2
AT14 0.75×2=1.50
AXIAL AND RADIAL CLEARANCE OF TURBINE ROTOR
RADIAL BEFORE (mm) AFTER (mm) CHECK

AXIAL AXIAL
RH133 0.06~0.12
RH143/163 0.06~0.12
INITIAL RH183/203 0.08~0.15
RH223/253 0.11~0.19
AT14 0.06~0.15
RADIAL RADIAL
RH133 0.37~0.57 <0.67
RH143/163 0.45~0.60 <0.80
ORIGIN RH183/203 0.45~0.60 ALLOWABLE <0.80
AXIAL
RH223/253 0.52~0.71 <0.93
AT14 0.64~0.84 <0.96
MEASUREMENT OF SEAL RING GROOVE
EX. WEAR
BEFORE (mm) AFTER (mm) CHECK
ROTOR SIDE

WIDTH OF WIDTH OF
GROOVE GROOVE
USABLE UNUSABLE

RH133 <2.36
WIDTH OF RH143/163 <1.87
GROOVE ALLOWABLE RH183/203 <3.37

AT14 <1.87
CONDITION OF PARTS
BREAKAGE □NO □BEND □BREAKAGE
TURBINE ROTOR CONTACT □NO □CARBON □PARTIAL □ALL AROUND
CARBON ACCUMURATION □SOOT □LIGHT □HEAVY □PARTIAL
BEND, BREAKAGE □NO □BEND □BREAKAGE
IMPELLER
CONTACT □NO □PARTIAL □ALL AROUND
CARBON ACCUMURATION □LIGHT □MID □HEAVY
TURBINE HOUSING CONTACT □NO □FOUND □CARBON
EROSION □NO □LIGHT □HEAVY
COMPRESSOR HOUSING CONTACT □NO □PARTIAL □ALL AROUND