Pilot Operated
Catalog
DG5V-7, 40 Series, Solenoid
Controlled, Pilot Operated
ISO 4401 Size 07
Table of Contents
2 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007
Introduction
General Description All spools have been Features and Benefits • The many optional fea-
DG*V-7 valves are used pri- designed to provide good • High pressure and flow tures, particularly for DG5V
marily for controlling the low shock, fast response capability for maximum valves, permit matching to
starting, stopping and direc- characteristics which can be cost-effectiveness. virtually every application
tion of fluid flow. enhanced by optional stroke within the valve’s power
and/or pilot choke adjust- • Low headloss to minimize capacity.
Two series of valves, DG5V ments. power wastage.
solenoid controlled, pilot • Optional mainstage
Models include spring offset, • Low shock characteristics spool position monitor-
operated and DG3V pilot to maximize machine life.
operated models are avail- spring centered, pressure ing switch (CE marked)
able with a choice of 18 dif- centered and detented ver- • Facility to change solenoid
ferent spools. These include sions. All are available with coils without disturbing
meter-in and meter-out the option of an integral P- the hydraulic envelope.
spools and a regeneration port pilot pressure generator.
type that can obviate extra DG5V valves can be arranged
valves essential in traditional for internal or external pilot
circuit arrangements. pressure and/or drain con-
nections.
Functional
Symbols
DG3V-7 Pilot Operated Models
Comprehensive and simplified symbols.
b a b a
P T Lb P
o aT X P T
2
X P T Y B A
b o a b o a B A
X P T Y B A X L P T Y B A
b o a
B A B A
X o a Y X o a Y
b b
P T L P T X P T
EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 3
3 3
Functional b
2
o a
Symbols
X P T Y B A
b o a b o a B A
X P T Y B A X L P T Y B A
b o a
B A B A
X o a Y X o a Y
b b
DG5V-7,PSolenoidT Controlled, Pilot Operated
L P TModels X P T
Comprehensive and simplified symbols shown configured for
external pilot supply and internal drain b o a b o a
X P T Y B A X P T Y B A
B A B A “a” and “b” interchanged for spool types 4
Spring Offset, End-to-End, Spring Offset, End-to-End, Spring Centered, DG5V-7-*C
DG5V-7-*A Spool types: All and 8.
Opposite
b a
Hand, DG5V-7-*AL b a “X” and “Y” spools require a stroke adjuster
Spool types: 0, 2, 6, 9, 35, 52, Spool types: 0, 2, 6, 9, 52, at one or both ends, dependent on the
521, X2 , Y2 521, X2 , Y2 application, to limit stroke towards “a”
P T Y P T Y and/or “b”.
b o a b o a
b o a b o a b o a
X P T Y B A X P T Y B A
X P B Y A B A X P TB Y A B A X P T Y B A
A B A B A B
b a b o a b a b o a b o a
b o o a b o a
P T Y X P P YT YB A X P T Y B A X P T Y B A
P T Y A P
B T Y A BP T Y A B
b o a b o a
b o a b o a b o a
X L P T Y B A X P T Y B A
X AP B Y B A X A PB T Y B A X P T Y B A
b o a b o a
A B A B A B
b o a b a
b o X L P T o aY B A X P T b o Ya B A
A B A B
L P
P T
T YY P T Y
P T Y P T Y
b o a b a Options 1
DG5V-7
Pressure Centered, DG5V-7-*D Detented, DG5V-7-*N
Spool types: All Spool
The following are shown in a
L Ptypes:
T 0,Y2, 6, 9, 52, 521, P T3 Y
X2 , Y2 DG5V-7-*C example:
3
1
1. Pilot choke
b o module
a
4 2
2. Minimum pilot 5pressure
X P T Y B A 3 3
generator
A B
b o a
3. Stroke adjusters, at either
4 2 5
or at both ends (shown at
b o a b o a b o a
both ends in example) X P T Y B A
A B
X L P T Y B A X P T Y B A 4. External pilot connection
A B A B
5. Internal
X Pdrain
T
b o a
b o a b a One or more options can be
built into any DG5 series
L P T Y P T Y valve, the only exception X P T
being that the internal drain 1
option is not available with
DG5V-7-*D (pressure cen-
tered) valves.
3 3
b o a
4 2 5
4 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007
X P T Y B A
A B
P T
Functional
Symbols
A B A B
P T T
X L P T Y B A X P T Y B A
b o a
Symbols on Nameplates
A B
Typical illustrations for:
P T b o a
A B
DG3V-7-2D-1 DG5V-7-3C-2-E-T-K
P T b o a
2 A B
4
A B P T
3
A B A B
T 1
P T T
X P T Y B A 1
A B A B
X L P T Y B A X P T Y B A
P T T
X L P T Y B A X P T Y B A
Spool Types
Shown in 3-position form, plus 2 transients.
b o a b o a
Notes: a o b
0A B 52
1. In the detailed and simpli-
P T fied symbols on this and
1 521 the previous pages, the
transient positions are omit-
X2 ted for simplicity.
2
2. In certain 2-position
A B
valves, the “o” position
3 Y2 becomes an additional tran-
T sient, i.e. in DG5V-7-*A(L)
6P X33 and DG5V-7-*N valves.
B A X T Y B A a o b
The
T performance of the
s and “34” spools differ
“33”
9 Y33
only ain the ocenterb position.
Your Eaton representative
a o b can provide further details.
11
4 ■ Only 35A available.
31
8
33 &
34
35 ■
EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 5
Model Codes
DG3V-7 20 Series, Pilot
Operated Directional Valves
1 2 3 4 8 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1 Fluid Compatibility 28= “2” and “8” combined ♦ 9 Manual Override Option or double-solenoid valves
Omit if not required ■ Some female plug connector options
Blank = Blank = Plain override in sole- available separately from Vickers
Antiwear hydraulic oil ▲ Not applicable to DG5V-7-*B(L) models. noid end(s) only ▲
(class L-HM), Systems (see “Plugs for ISO 4400” on
invert emulsion (class L-HFB), ▼ Not applicable to models shown in H = Water-resistant manual page A.16). Others available from electri-
or water glycol (class L-HFC)
the “Spring offset, end-to-center, override on solenoid end(s)▲ cal stockists.
opposite hand” section on page A.3.
F3 = As above or phosphate Z = No override at either end ♦ Female connector to be supplied by user.
ester (class L-HFD) ♦ Not applicable to models shown in
the “Spring offset, end-to-center” section ▲ No override in non-solenoid end of 12 Indicator Lights, Option
on page A.3. single-solenoid valves.
Note: For further information see for Codes FTJ, FTW, FPA3W
“Hydraulic Fluids” section on page A.12.
5 Main Stage Spool 10 Solenoid Energization and FPA5W in item 10.
2 Spool Type Monitoring Switch Indentity L = Lights fitted
See “Functional Symbols” (Omit if not required.) V = Solenoid “A” is at port A Omit if lights not required
section on pages 3-4. PCA - Center sensing switch end of pilot valve and/or
solenoid “B” at port B For U-code solenoids use plug with
on “A” port end integral light, see page A.16.
3 Spool Spring end independent of
PCB - Center sensing switch
Arrangement on “B” port end main-stage valve port 13
locations or spool type; Coil Rating
A = Spring offset, end-to- PDA - Double offset sensing
end (P to B when oper- switch on “A” port end German practice. See “Operating Data” on
ated) PDB - Double offset sensing Omit (except as noted page XX for further informa-
switch on “B” port end below) for US ANSI B93.9 tion.
AL = As “A” but left-hand standard whereby solenoid
PCD - Center sensing switch
build (P to A when “A” is that which, when A = 110V AC 50 Hz
on “A” port end and
operated)
double offset sensing energized, connects P to A B = 110V AC 50 Hz/ ♦
B= Spring offset, end-to- switch on “B” port end in main-stage valve, and/or 120V AC 60 Hz
center (P to B when PPA - Offset sensing proximity solenoid “B” connects P to B.
operated) ■ Note: Energization identities on valves C = 220V AC 50 Hz
switch “A” port end
BL = As “B” but left-hand PPB - Offset sensing proximity with type 4 or 8 spools are identical D = 220V AC 50 Hz/ ♦
under US and German practices. In such
build (P to A when swtich “B” port end
cases the “V” code is used.
240V AC 60 Hz
operated) ■ PPD - Offset sensing proximity G = 12V DC
switch both ends 11
Solenoid
C= Spring centered * The spool position monitoring switch H = 24V DC
Type/Connection(s)
D= Pressure centered shown on this technical document is CE ♦ For 60 Hz or dual frequency.
marked and certified and complies to U = ISO 4400 (DIN 43650)
N= Two-position detented European Standard EN 61000-6-4: 2001 mounting ■ 14 Design Number
■ DG5V option. Same function from (Emissions) for Class A and European
DG3V-7-*C valves by alternating pilot Standard EN 61000-6-2: 2001 (Immunity). FW = 1/2 NPT thread 20 series for DG3V valves.
supply to one port (X or Y) and perma- junction box 40 series for DG5V valves.
nently draining the other. 6 External Pilot Supply.
FTW = 1/2 NPT thread Subject to change. Installation dimen-
DG5V Valve Option junction box and sions unaltered for design numbers *0
4 Spool Control to *9 inclusive.
Omit for internal pilot supply terminal strip
1 = Stroke adjustment at both FJ = M20 thread
ends ▲ 7 Internal Pilot Drain, DG5V
junction box For Mounting Subplate
2 = Pilot choke adjustment Valve Option
FTJ = M20 thread junction and Fastener Kit Options
both ends Omit for external drain, which See “Supporting products”
box and terminal strip
3 = “1” and “2” combined ▲ is also mandatory for 1, 4, 8 on page A.10.
7 = Stroke adjustment, port A and 9 spool-type valves FPA3W= Junction box with
3-pin male connector ♦ to For ISO 4400 (DIN 43650)
end only ▼ Electrical Plugs to Suit
8Minimum-Pilot-Pressure NFPA T3.5.29-1980 for sin-
8 = Stroke adjustment, port B Generator (“P” Port Option) gle-solenoid valves DG5V---(V)M-U Valves
end only ▼ See “Installation Dimensions”
K = 0,35 bar (5 psi) cracking FPA5W= Junction box with and “Electrical Plugs and
27= “2” and “7” combined ▼ pressure 5-pin male connector♦ to Connectors” on page A.13.
Omit if not required NFPA T3.5.29-1980 for single
6 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007
Application Notes
EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 7
Operating Data
MAXIMUM PRESSURES:
DG3V-7 valves; ports:
P, A, B, T, X and Y 350 bar (5000 psi)
L 0,5 bar (7 psi)
DG5V-7-**(L)(-*)(-E)(-*) valves, (externally drained); ports:
P, A, B, T and X 350 bar (5000 psi) ▲
Y 100 bar (1500 psi) ▲
L 0,5 bar (7 psi)
DG5V-7-**(L)(-*)(-E)-T(-*) valves, (internally drained)u; ports:
P, A, B and X 350 bar (5000 psi) ▲
T 100 bar (1500 psi) ▲
Available for all except the DG5V-7-D pressure centered models
▲ The DG5V, 40 design two-stage valves have been designed to satisfy the needs of most applications.
Consult your Eaton representative about an alternative model if:
a) Valves are required to remain pressurized for long periods without frequent switching, and /or
b) Back pressure on the drain port of externally drained models (or the tank port of internally drained models) is required to rise above 100 bar (1500 psi).
MAXIMUM FLOW RATES, L/MIN (USGPM) AT THE MINIMUM PILOT PRESSURES ■ , AND WITH SPOOL TYPE:
See Pilot Pressures on page XX 70 (1000) 140(2000) 210 (3000) 280 (4060) 350 (5000)
0, 2, 3, 6, 31, 33, 52 or 521 ◆ 300 (80) 300 (80) 300 (80) 300 (80) 300 (80)
1, 4, 9 or 11 260 (69) 220 (58) 120 (32) 100 (26) 90 (24)
8 300 (80) 300 (80) 250 (66) 165 (44) 140 (37)
■ Higher flow rates possible at higher pilot pressures; consult your local Eaton sales engineer.
◆ Consult your local Eaton sales engineer regarding flow limits relative to the regenerative position of type 52 and 521 spools.
8 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007
Operating Data
EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 9
Performance
Characteristics
Pilot Pressures
Maximum: 350 bar (5000 psi).
Typical minimum differential
pilot pressure characteristics,
shown below, are based on
looped flow through P to A to
B to T under standard test
conditions.
psi bar
200
12 Spool 0 1 2 3 4 6 8 9 11 31 33 52 X* Y*
160 3 Types
Min. differential pilot pressure
10 Curve 1 1 3 3 1 2 1 1 1 3 3 3 3 3
ref.
120 2
8 Applicable to:
Model Spool type Curve correction
6 DG3V-7-*C All As drawn
80
1 DG3V-7-*D All Add 5 bar (73 psi)
4
DG5V-7-*A(L) 0, 2, 6, 9, 52, X2 &Y2 Subtract 3 bar (44 psi)
40 DG5V-7-*B(L) 0, 2, 6, 52▲, X2& Y2 As drawn
2
DG5V-7-*C All As drawn
0 DG5V-7-*D All Add 5 bar (73 psi)
0 100 200 300 L/min DG5V-7-*N 0, 2, 6, 9, 52, X2 &Y2 As drawn
▲ DG5V-7-52BL models only.
0 20 40 60 80 USgpm
Flow rate
10 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007
Performance
Characteristics
EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 11
Installation
Dimensions
Millimeters (inches)
Solenoid Controlled Models with ISO 4400 (DIN 43650) 3rd angle
Electrical Connections and Pilot Choke projection
DG5V-7–**(L)(-2)(-E)(-T)(-K)(-*)-(V)M–U example
For dimensions A, B, C, D and E see page A.15.
For solenoid identification see page A.15.
For stroke adjusters see page A.14.
71,5 69,8
(2.815) (2.75)
51 (2.0)
With pilot A B
choke fitted: Locknut
222,0 (8.74) 40 (1.57) Plain manual override or no
manual override; for type “H”
Without pilot
manual override see page
choke:
A.15.
182,0 (7.17)
95,1
(3.74)
33,0 (1.3) 33,0 (1.3)
6 places
4,0
(0.16) 46,4
D E
(1.83)
92,8
Mounting surface. 2 location pins (3.65)
Sealing rings supplied. Ø3.0 (0.12 dia.)
95,2
Pilot choke adjusters fitted when (3.65)
Model Code 4 = 2, 3, 27 or 28.
To adjust, turn locknut counter-clockwise,
then turn screw clockwise to slow down rate
of spool travel, or counter-clockwise to
increase the rate. Retighten locknut to May vary according to plug source. Cable entry can be positioned at 90
25-30 Nm (18-22 lbf ft). Alternative plug positions by loosening either way from position shown, by
knurled nut counter-clockwise, turning re-assembling the contact holder into the
coil and re-tightening nut. appropriate position inside the plug
connector housing.
12 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007
Optional Features
Stroke adjuster fitted this end when Stroke adjuster fitted this end
Model Code 4 = 7 or 27 when Model Code 4 = 8 or 28
To adjust:
Turn locknut counter-clockwise, then Locknut
turn screw clockwise to shorten stroke,
or counter-clockwise to increase stroke.
Re-tighten locknut. 48,0 (1.89) 48,0 (1.89)
max. max.
Stroke adjuster fitted both ends when With pilot choke fitted:
Model Code 4 = 1 or 3 160,0 (6.3)
Stroke adjuster fitted this end when Without pilot choke:
Model Code 4 = 7 or 27 120,0 (4.73)
EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 13
Optional Features
SOLENOID IDENTIFICATION
Model Spool types Solenoid identity at: Solenoid identity at:
(see also in “Model Code” on page A.6) Main port “A” end Main port “B” end
DG5V-7-*A/B(-**)(-E)(-T)(-K)(-*)-M All except “4” & “8” – B
DG5V-7-*A/B(-**)(-E)(-T)(-K)(-*)-VM All except “4” & “8” – A
“4” & “8” only B –
DG5V-7-*AL/BL(-**)(-E)(-T)(-K)(-*)-M All except “4” & “8” A –
DG5V-7-*AL/BL(-**)(-E)(-T)(-K)(-*)-VM All except “4” & “8” B –
“4” & “8” only – A
DG5V-7-*C/D/N(-**)(-E)(-T)(-K)(-*)-M All except “4” & “8” A B
DG5V-7-*C/D/N(-**)(-E)(-T)(-K)(-*)-VM All spools B A
DIMENSIONS
Basic model designation AC models DC models
A B C A B C D E
DG3V-7-*C – – – – – – 97,0 (3.82) 97,0 (3.82)
DG3V-7-*A ■ – – – – – – 97,0 (3.82) 131,0 (5.16)
DG3V-7-*A(L) ■ – – – – – – 131,0 (5.16) 97,0 (3.82)
DG3V-7-*D
DG5V-7-*A ■ – 147 (5.8) – – 157 (6.2) – 97,0 (3.82) 97,0 (3.82)
DG5V-7-*B ■
DG5V-7-4/8BL
DG5V-7-*AL ■ – – 147 (5.8) – – 157 (6.2) 97,0 (3.82) 97,0 (3.82)
DG5V-7-*BL ■
DG5V-7-4/8B
DG5V-7-*C 200 (7.8) – – 220 (8.7) – – 97,0 (3.82) 97,0 (3.82)
DG5V-7-*N
DG5V-7-*D 200 (7.8) – – 220 (8.7) – – 131,0 (5.16) 97,0 (3.82)
■ Not types “4” or “8” spools.
14 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007
Electrical
Information
33.0 (1.30)
191.7 (7.55)
SPECIFICATIONS
Supply Voltage (Vs) 10 to 30 Vdc
Supply Current (ls) 8 mA at 24 Vdc (plus load current)
Supply Over-voltage Rating: 35 Vdc continuous
Supply Reverse Polarity Rating -35 Vdc (with no shorts)
Short Circuit Tolerance: Continuous short between any two pins
High Potential Test, Pin to Case: 300 Vdc
Electronmagnetic Compatiblity: ISO 7637 Parts O and I worst case and
Immunity to Radiated Electromagnetic
Fields, 10 KHZ to 1 GHZ per SAE J1113/25
Sep 95
Pins to Case Resistance 50 Megohms
Load Dump Tolerance: 80 Vdc Peak, 400 ms Decay, with 1.5 Ohm
Source Impedance
Switching Frequency: 0 to 3K Hz
Ouput: Open collector PNP sourcing, normally open
Sensing Distance (offset position): 1.27 ± 0.25 mm (.050” ± .010”)
Hysteresis: 0.25 mm (.010”) Max.
Rise/Fall Time: 6.5/1.5 microsec R1=820 Ohm,
C1=20 pF @ 8Vdc
Ouput Leakage Current 10µa Max.
Output Voltage High: +Vs – 2.2 Vdc minimum
Output Load Current: 200 mA Max.
Operating Pressure: 350 bar (5000 psi)
Operating Temperature: -40˚ to 110˚C
Humidity: 0 to 100%
Functional Diagram - Spring Offset Output Circuit Wiring Instructions Connector Detail
center condition (ref.)
1 PIN 1
1
Power Supply PIN #4 PIN #3
PIN 4 Signal
0 = sensor at "A" port side 10K
Common
stab
(if applicable) PIN 4 =
=
4
Signal Output
1 =
PIN 3
= PIN 4 Common
2
= sensor at "B" port side SENSOR
0 (if applicable) PIN #1 PIN #2
3
+24VDC±20% Not Used
EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 15
Electrical
Information
DG5V-7 with Main Stage Spool Monitoring Switch
“PCA”, “PCB”, “PDA”, “PDB”, PCD” Models (LVDT style)
Millimeters (inches)
425,1 (16.73)
220,0 (8.66)
146,9
(5.78)
161,0 (6.34)
M12 Thread
Connection
A Port Side
B Port Side
SPECIFICATIONS
33,0 (1.30)
(Center Sensing)
Switch Point
(Center Sensing)
Switch Point
Center
Full Stroke
Full Stroke
Switch Point
Center
Switch Point
Full Stroke
Full Stroke
Switch Point
Center
Switch Point
Full Stroke
Signal 0 = Voltage at pin 2/4 < 1.8V Signal 0 = Voltage at pin 2/4 < 1.8V Signal 0 = Voltage at pin 2/4 < 1.8V
Signal 1 = Voltage at pin 2/4 > (Vs – 2.5V) Signal 1 = Voltage at pin 2/4 > (Vs – 2.5V) Signal 1 = Voltage at pin 2/4 > (Vs – 2.5V)
Electrical Schematic and Mating Connector Detail
Connector Detail
Input 1
=
stab
24V ±20% PIN #3 PIN #2
=
= Common Signal
=
Output 4
RL1
=
=
Output 2
DEMO- OVERLOAD
RL2
OSZILATOR
DULATOR PROTECTED
OUTPUT Ground 3
PIN #4 PIN #1
Signal +24VDC±20%
R L1,RL2 = e.g. Coil Resistance of the switch relay >/= 60 OHMS
1
16 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007
=
stab
=
=
Valve for Safety
Circuit Application
(35A Spool)
PT
A
B
C
D
500
400
300
p – PSI
P-A
B-T
200
100
0
0 10 20 30 40 50 60 70 80
Flow – GPM
EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 17
Electrical
Information
NFPA Connector T3.5.29-1980 Connection details and model type/model code references
5-lead
1-lead (to solenoid)
1-green lead 3-lead (to solenoid)
(ground) (to solenoid)
1 1 5
2 4
2 3 3
25,4 (1.0) hex.
4-lead (capped)
2-lead 2-lead 3-green lead
(to solenoid) (capped) (ground)
18 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007
Electrical
Information
DG5V-7-**(L)---F****-* DG5V-7-**(L)---F****L-*
28,50 30,00
(1.12) (1.18)
1. For DC coils the +ve lead(s) must be 2. For correct light indication of energized
connected to the terminal(s) marked +. solenoid ensure that solenoid leads are
When using 3-wire incoming leads to correctly connected: light terminals are
double solenoid valves (i.e. common common with each outer pair of solenoid
neutral) the inner pair of terminals must terminals according to the side with +
be linked. mark.
EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007 19
Released Assembly
Numbers of Valve
with Main Spool
Monitoring Switch
Size D07/NG16
ASSEMBLY ASSEMBLY
NUMBER MODEL CODE NUMBER MODEL CODE
02-396643 DG5V-7-0A-PPA-T-K-M-U-H7-30 5996923-001 DG5V-7-2C-PPD-T-M-U-H7-30
02-396644 DG5V-7-0C-PPD-T-K-M-U-A6-30 02-397195 DG5V-7-35A-PPA-E-Z-VM-U-H7-30
5996907-001 DG5V-7-0C-PPD-T-K-M-U-A7-30 5996924-001 DG5V-7-6C-PCA-T-M-U-H7-30
5996914-001 DG5V-7-2A-PCA-T-M-U-H7-30 5996925-001 DG5V-7-6C-PCD-T-M-U-H7-30
5996915-001 DG5V-7-2A-PCD-T-M-U-H7-30 02-397714 DG5V-7-6C-PDA-E-M-U-H7-30
5996916-001 DG5V-7-2A-PDA-T-M-U-H7-30 5996926-001 DG5V-7-6C-PDA-T-M-U-H7-30
5996917-001 DG5V-7-2A-PPA-T-M-U-H7-30 5996927-001 DG5V-7-6C-PPA-T-M-U-H7-30
5996918-001 DG5V-7-2A-PPD-T-M-U-H7-30 02-397713 DG5V-7-6C-PPD-E-M-U-H7-30
5996919-001 DG5V-7-2C-PCA-T-M-U-H7-30 5996928-001 DG5V-7-6C-PPD-T-M-U-H7-30
02-362980 DG5V-7-2C-PCD-T-M-U-H7-30
02-362980 DG5V-7-2C-PCD-T-M-U-H7-30
5996921-001 DG5V-7-2C-PDA-T-M-U-H7-30
5996922-001 DG5V-7-2C-PPA-T-M-U-H7-30
20 EATON Vickers Pilot Operated Directional Valves Catalog V-VLDI-MC007-E March 2007
Eaton Eaton Eaton
14615 Lone Oak Road 20 Rosamond Road Dr.-Reckeweg-Str. 1
Eden Prairie, MN 55344 Footscray D-76532 Baden-Baden
USA Victoria 3011 Germany
Tel: 952 937-9800 Australia Tel: (49) 7221 682-0
Fax: 952 974-7722 Tel: (61) 3 9319 8222 Fax: (49) 7221 682-788