We just want to take a moment out to thank you for your keen interest in our company
products. We greatly appreciate your business and the opportunity you provided us to
assist you. You have joined a selected group of customers who have switched to the
technologically superior and quality enhanced laboratory testing product.
Time has changed, so do the technology. Your purchase lists you on the cutting edge of
21st century technology. The attached test report is an excellent way of expressing and
maintaining your trust in EIE’s - superior quality testing products. Our continued efforts
and commitment is to provide you efficient sales after services, prompt attention and
highest level of customer satisfaction. If for any reasons, you have questions or
comments, we are delighted to hear from you. Call us on 0091-79-660406013 or send us
email at info@eieinstruments.com/kunal@eieinstruments.com. You can expect us to
respond to your email within 24-48 working hours.
Once again, thank you for your trust and kind patronage. We look forward to serve you
better in future.
Yours sincerely,
EIE Instruments
Table of contents
List of tables
Table 1 Observation Table....................................................................................................................7
Table 2 Sample calculation chart........................................................................................................8
List of figures
Figure 1 testing section........................................................................................................................8
The energy, in general, may be defined as the capacity to do work. Though the energy exists in
many forms, yet the following are important from the subject point of view:
1) Potential Energy
2) Kinetic Energy and
3) Pressure Energy
2 2
v /2g meter of the liquid. Velocity head of the liquid, at that velocity, will be v /2g meter of liquid.
2
is under a pressure of p kg/m , then the pressure energy of the particle will be p/w mkg per kg of
p v²
E= w + 2g +Z
6. Bernoulli’s equation
It states, “For a perfect incompressible liquid, flowing in a continuous stream, the total energy of
a particle remains the same; while the particle moves from one point to another.” This
statement is based on the assumption that there are no losses due to friction in pipe.
Mathematically,
p v²
E= w + 2g + Z = Constant
7. Apparatus description
The apparatus is made from transparent acrylic and has both the convergent and divergent
sections. Water is supplied from the constant head tank attached to the test section. Constant level
is maintained in the supply tank. Piezometric tubes are attached at different distance on the test
section. Water discharges to the discharge tank attached at the far end of the test section and from
there it goes to the measuring tank through valve. The entire setup is mounted on a stand.
8. Experimental Procedure
1) Note down the area of cross-section of the conduit at sections where piezometers have been
fixed.
2) Open the supply valve and adjust the flow in the conduit so that the water level in the inlet
tank remains at a constant level (i.e., the flow becomes steady).
9. Observation table
Area of cross-section, A
0.01/ t Run No.2 0.01/ t Run No.1
V=Q/A
2
V /2g
(p/ρg) + z
Discharge =Q2 =
E
V=Q/A
2
V /2g
(p/ρg) + z
Run No.3 Discharge
E
= Q3 = 0.01/ t =
V=Q/A
2
V /2g
(p/ρg) + z
E
Table 1 Observation Table
Plot the following graph on an ordinary graph paper for all runs taken.
1) {(p/ρg) + z} v/s distance (x) of piezometer tubes from some reference point. Draw a smooth
curve passing through the plotted points. This is known as the hydraulic gradient line.
2) E = {(p/ρg) + z + V2/2g} v/s distance (x) of piezometer tubes on the graph {(p/ρg) + z} v/s
distance. Draw a smooth curve passing through the plotted points. This is the total energy line.
9.1 Conclusion
The Total Energy remains the same at different sections of the conduit.
Piezometer 1 2 3 4 5 6 7
tube number
Area of cross-
section, A 8.23x10-4 3.86x10-4 2.11x10-4 3.5 x10-4 5.26x10-4 7.6 x10-4 9.83x10-4
V=Q/A
X 10-4sec) Run No.1 Discharge
Run 1:
Discharge time for 10cm rise in water column: 41 sec
41
Warranty Certificate
Your EIE product is guaranteed to be free from defects in materials and workmanship for
one (1) year under normal use from the date of purchase. This WARRANTY does not apply to
any product damaged by accident, misuse, mishandling, abuse, negligence, transit,
improper line voltage, drop, fire, flood or if the products were altered or repaired by anyone
other than the qualified service personnel. The liability of EIE Instruments is limited to repair
or replacement and under no circumstances shall EIE be liable for any collateral
consequential damages or loss. This guarantee specifically excludes the expendables and
consumables.
All warranty claims must be directed to your corresponding
purchase organization that is responsible for the sale of this equipment. The users are
responsible for shipping expense. The warranty cards which are not signed and stamped by
the actual user will be treated as void. The warranty card should accompany the defective
products sent for repair, without which no claims would be entertained. Please detach the
below warranty card from following cut-line.
………………………………………………………………………………………………………………………………………
Address:
Telephone no:
Mobile no:
Email address:
Date of purchase:
Product model:
Serial no:
This card should be detached, filled in properly and posted within 15 days from the date of
purchase otherwise the warranty becomes invalid.
Please write us
Thank you
We are in….
www.eieinstruments.com | www.eieceratest.com
www.eiepharmatest.com | www.eiepetrostest.com