Sunteți pe pagina 1din 2

SHEET 1 OF 1

DIFFERENTIAL PRESSURE INSTRUMENTS


SPEC. NO. REV.
NO. BY DATE REV. A
A P.A. 13/03/04 Aprobación CONTRACT NO DATE
3/15/2004
REQ. P.O.
Universidad Tecnológica Nacional

Facultad Regional Buenos Aires BY CHK´D APPR.

P.A. C.H. C.H.


1 Tag No. FIT-000 Service Control de Caudal entrante a E-001
2 Function Record Indicate Control Blind Trans Integ. Other
3 Case MFR STD Nom. Size Color: MFR STD Other
4 Mounting Flush Surface Yoke Other: Sobre caño DN 2"
5 Enclosure Class General Purpose Weather proof Explosion proof Class
For use in intrinsically Safe System Other:
GENERAL 6 Power Supply 117 V 60 Hz Other ac dc volts
7 Chart 12 in. Circ. Other Range No
8 Chart Drive 24 hr. Other Elec. Spring Other
9 Scale Type Rango: 1 2 3

XMTR 10 Transmiter 4-20 mA 10-50 mA 21-103 kPa (3-15 psig) Other


Output For Receiver See Spec. Sheet
11 Control Modes P = Prop. (Gain). I = Integral (Auto Reset). D = Derivative (Rate)
Sub: S-Slow F-Fast
P PI PD PID IF DF IS DS
Other
CONTROLER 12 Action On Meas. Increase Output: Increases Decreases
13 Auto-Man Switch None MFR STD Other
14 Set Point Manual External Remote Other
15 Manual Reg. None MFR STD Other
16 Output 4-20 mA 10-50 mA 21-103 kPa (3-15 psig) Other
17 Service Flow Level Diff. Pressure Other
18 Element type Diaphragm Bellows Mercury Other
19 Material Body Inoxidable Element
20 Rating Overrange Body Rating
21 Diff. Range Fixed Adj. Range Set at
ELEMENT
22 Elevation Supression
23 Process Data Fluid Max. Temp. Max. Press.
24 Process Conn. 1/4 in. NPT Other 1/2 in. NPT

25 Alarm Switches Quantity Form Rating


26 Function Meas. Var. Deviation Contacts To on Inc. Press.
27 Options Pressure Element Range Material
Temp. Element Range Type

Filt-Reg. Sup. Gage Output Gage Charts


Valve Manifold Incluir Manifold de 3 Vías. Conexión a Proceso 1/2" NPT
Cond. Pots Adj. Damp Integral Sq. Rt. Ext.
Integrator
Other Con accesorio para montaje en caño Dn 2"
28 Mfr. & Model No. HONEYWELL

NOTES:

ISA FORM S20.53


SHEET 1 OF 1
DIFFERENTIAL PRESSURE INSTRUMENTS
SPEC. NO. REV.
NO. BY DATE REV. A
A P.A. 13/03/04 Aprobación CONTRACT NO DATE
3/15/2004
REQ. P.O.
Universidad Tecnológica Nacional

Facultad Regional Buenos Aires BY CHK´D APPR.

P.A. C.H. C.H.


1 Tag No. FIT-001 Service Control de Caudal entrante a E-003
2 Function Record Indicate Control Blind Trans Integ. Other
3 Case MFR STD Nom. Size Color: MFR STD Other
4 Mounting Flush Surface Yoke Other: Sobre caño DN 2"
5 Enclosure Class General Purpose Weather proof Explosion proof Class
For use in intrinsically Safe System Other:
GENERAL 6 Power Supply 117 V 60 Hz Other ac dc volts
7 Chart 12 in. Circ. Other Range No
8 Chart Drive 24 hr. Other Elec. Spring Other
9 Scale Type Rango: 1 2 3

XMTR 10 Transmiter 4-20 mA 10-50 mA 21-103 kPa (3-15 psig) Other


Output For Receiver See Spec. Sheet
11 Control Modes P = Prop. (Gain). I = Integral (Auto Reset). D = Derivative (Rate)
Sub: S-Slow F-Fast
P PI PD PID IF DF IS DS
Other
CONTROLER 12 Action On Meas. Increase Output: Increases Decreases
13 Auto-Man Switch None MFR STD Other
14 Set Point Manual External Remote Other
15 Manual Reg. None MFR STD Other
16 Output 4-20 mA 10-50 mA 21-103 kPa (3-15 psig) Other
17 Service Flow Level Diff. Pressure Other
18 Element type Diaphragm Bellows Mercury Other
19 Material Body Inoxidable Element
20 Rating Overrange Body Rating
21 Diff. Range Fixed Adj. Range Set at
ELEMENT
22 Elevation Supression
23 Process Data Fluid Max. Temp. Max. Press.
24 Process Conn. 1/4 in. NPT Other 1/2 in. NPT

25 Alarm Switches Quantity Form Rating


26 Function Meas. Var. Deviation Contacts To on Inc. Press.
27 Options Pressure Element Range Material
Temp. Element Range Type

Filt-Reg. Sup. Gage Output Gage Charts


Valve Manifold Incluir Manifold de 3 Vías. Conexión a Proceso 1/2" NPT
Cond. Pots Adj. Damp Integral Sq. Rt. Ext.
Integrator
Other Con accesorio para montaje en caño Dn 2"
28 Mfr. & Model No. HONEYWELL

NOTES: