Sunteți pe pagina 1din 4

Product Data

3000
Medical Dry Imager

Application adjustment and Fuji micro-isolating Direct Input Kits


film technology. Fuji’s new Advanced
The Fuji Medical Dry Imager DryPix DP 3000 CR Input Kit
Variable Response (A-VR) Spline
3000 is a compact tabletop image DP 3000 DICOM input Kit
image interpolation offers ultra-sharp
recording device that uses Fujifilm’s DP 3000 Standard Video Input Kit
alphanumerics with a wide range of
innovative DuraTherm™ thermal DP 3000 High Speed Video Input Kit
image interpolation from ultra-sharp
head technology to print the image DP 3000 Digital Input Kit
to ultra-smooth ideally matched to the
data sent from medical diagnostic DP 3000 Siemens Digital Input Kit
imaging requirements of each diag-
imaging modalities. Its primary appli- DP 3000 Digital Video Input Kit
nostic application.
cation is for decentralized imaging All kits include:
departments, imaging centers and sin- *Interface board
gle modalities where a quiet, compact System Configuration *48MP Frame Buffer Memory
*Connection Cables to Host up to 100m
imager is required. Standard Components: (not included in DICOM Input Kit)
DryPix 3000 Dry Thermal Imager *Operator Keypad and Cable (not included in
CR or DICOM Input Kit)
Features Package Includes: *Keypad Power Adapter (if needed)
DryPix 3000’s compact tabletop *DryPix 3000 Dry Thermal Imager
design allows maximum flexibility of *96MP Page Buffer Memory Print Server Input Kits
placement in medical imaging facili- *Film Magazine
*One empty input port DP 3000 DICOM Print Server and
ties where space is at a premium. Input Kit
Fujifilm’s innovative DuraTherm™ *Power Cord - 3m
*DryPix 3000 Service Manual DP 3000 Fuji FinP Print Server and
thermal head technology used in the Input Kit
DryPix 3000 ensures stable printing Single Input Systems: DP 3000 Toshiba Network Print
performance and extended thermal DryPix 3000 Single CR Input System Server and Input Kit
head life beyond three years or 50,000 Includes: All kits include:
films. *DryPix 3000 Dry Thermal Imager Pkg. *Interface board
The DryPix 3000’s almost silent oper- *DP 3000 CR Input Kit *48MP Frame Buffer Memory
DryPix 3000 DICOM System *Cable to Connect DP L to Print Server (up to
ation allows it to be placed in close 100m.)
proximity to the operator without dis- Includes:
*FN-PS 551 Print Server Package
*DryPix 3000 Dry Thermal Imager Pkg.
comfort or distraction. *DP 3000 DICOM Input Kit
Fujifilm has designed a new internal
DryPix 3000 Single Video Input Supplies
DICOM network board for the DryPix System Includes: Fuji Medical Dry Imaging Film
tabletop imagers. This enables net- *DryPix 3000 Dry Thermal Imager Pkg.
DI-AT (Blue base) DI-ATc (Clear
work printing without the need for an *DP 3000 Std. Video Input Kit
base):
external Print Server. DryPix 3000 Single Digital Input
14"x17" 100 sheets per box
The DryPix 3000 can be used to print System Includes:
*DryPix 3000 Dry Thermal Imager Pkg. 500 sheets per case
14x17" films. It processes 50
*DP 3000 Digital Input Kit Storage Conditions:
(14"x17") films per hour, providing
Temperature 50ºF to 74ºF
excellent throughput for decentralized Options Relative Humidity 45+/- 15% RH
imaging applications.
The DryPix 3000 has unrivalled gray DP 3000 Additional Film Magazine
scale reproduction, image consistency DP 3000 48MP Frame Buffer Mem.
and image stability due to its 12 bit DP 3000 Table Top Turn-Table
density resolution, automatic density DP 3000 Stand-Alone Cart
Specifications Dimensions and Weight Environmental Conditions
Thermal Recording and DryPix 3000: (Continued)
Development Unit: Width: 23" Magnetic Field
DuraTherm™ Thin Film type Depth: 19 4" (25 w" with film tray) *< DC 100 Gauss
Thermal Head Height: 14 w"
Micro-Isolating Film Technology Weight: 90 lbs. Maximum Heat Generation
Stand-Alone Cart DryPix 3000:
Processing Capacity: Width: 24" *Standby 400 BTU / hour
14"x17" 50 films / hour Depth: 38" *Operation 1400 BTU / hour
Height: 27 2"
Spatial Resolution: Weight: 55 lbs. Noise Level
Spatial Resolution 11.8 pixels/mm DryPix 3000:
(300 dpi) Power Supply *Standby <55 dB
Pixel Size 84.7 microns *Operation < 60 dB
DryPix 3000:
*Noise burst < 70 dB
100-240 VAC +/-10%
Gray Scale Resolution: (Measuring conditions: 1m from
50/60 Hz +/- 3% Single Phase
12 bits (4096 gray levels) equipment, height 1.5 m)
Rated Current 7 to 4A
Overload Protection 6.3A x 2
Maximum Density: Power Consumption 700W
Warm-up Time
Standard 3.0 or 2.64 DryPix 3000:
Environmental Conditions *Ambient temperature 77ºF
Number of Inputs: Approximately 5 minutes
1 (direct) Temperature and Humidity:
Connectable Devices: Operating Ventilation Requirements:
*DICOM Network (Direct) *Temperature 59ºF to 86ºF DryPix 3000:
*FN-PS 551 Network Print Server *Relative Humidity 15% to 70% *Be sure to install this equipment in
*Fuji Computed Radiography Readers Non-Operating a well-ventilated environment
*Imaging Modalities e.g. CT, *Temperature 32ºF to 113ºF
MRI etc. using Video, Digital *Relative Humidity 10% to 90%
or Digital Video connection (No condensation)
*MF-300 Series Multi-formatters Transit / Storage
*Temperature 14ºF to 122ºF
*Relative Humidity 10% to 90%
Film Supply:
(No condensation)
Standard 1 Film Magazine
Atmospheric Pressure
True Daylight Film Loading Operating
Film is not light sensitive *700 to 1060 hPa
Non-Operating
Density Adjustment: *500 to 1060 hPa
Automatic
Floor (Installation Surface):
Memory (RAM) Vibration Requirement
Page Buffer 96 MP (Standard) *Frequency 10 to 55 Hz
Frame Buffer 48 MP/ Input (Std.) *Amplitude < 0.0005"
Maximum 192 MP (Mega Pixels) Levelness
*<1/100 inclination front to rear
and left to right
Flatness
*<0.4"
DRYPIX 3000 External Dimensions

23"

194"
25w"
62"
23"
25w"
194"
62"

14w"
Installation Space Space Required for Maintenance
Work
4" 8"

4"
8" 8"

20"
20"
Space Required for Turning the
Equipment

332"
Connectivity Diagram

DryPix 3000 DryPix 3000 DryPix 3000 FN-PS 551 DryPix 3000

Ethernet

DICOM Box

MR WS
SmartCR

US US

DryPix 3000
SmartCR

CT DryPix 3000

MR
MF-300L

WS DryPix 3000

DryPix 3000

NM

DryPix 3000
US

Specifications subject to change without notice


Fujifilm Medical Systems U.S.A., Inc.
Corporate Headquarters
419 West Avenue 1055 Stevenson Court 516 S. Varney Street 2001 Westside Parkway 12919 S.W. Freeway
Stamford, CT 06902-6300 Roselle, IL 60172-2300 Burbank, CA 91502-2126 Suite 165 Suite 180
203-324-2000 630-582-2202 818-843-4710 Alpharetta, GA 30004-7408 Stafford, TX 77477-4122
800-431-1850 800-323-2546 800-431-2861 770-346-0120 281-240-6363
888-699-FUJI (3854) 866-611-2085