ECC-VAVS
ECC-PFCU
EC-HPU-L
EC-FCU-L
EC-RTU-L
ECC-VAV
EC-UV-L
Inputs
Universal (total) 4 2 6 6 6 6 6
Digital (dry contact)
Voltage (0-10V)
Current (4-20mA with ext. 249Ω)
Thermistor (10kΩ Type 2)
Thermistor (10kΩ Type 3)
Platinum Pt1000 (1kΩ RTD) ─ ─ ─ ─
Platinum Pt100 (100Ω RTD) ─ ─ ─ ─
Nickel Ni1000 (1kΩ RTD) ─ ─ ─ ─ ─ ─
Potentiometer (transtable)
Software configurable
Ability to use spare inputs
1,2 1,2
Optional wireless inputs 6 4 5 ─ ─ ─ ─
1 1
EC-Smart-Sensor capability ─ ─ ─ ─
Analog/digital converter (bit) 16 16 16 12 12 12 12
Outputs
3
Universal (analog) 2 ─ 2 2 2 2 2
Digital (relay) ─ ─ 4 ─ ─ ─ ─
Digital (triac) 4 2 4 5 5 5 5
4
Network (using NVOs) 6 2 8/10 ─ ─ ─ ─
Ability to use spare outputs (NVIs)
Output LED status indicators ─ ─ ─
Digital/analog converter (bit) 10 10 10 8 8 8 8
Power Input
24V AC ─
85-265V AC ─ ─ ─ ─ ─ ─
Enclosure
Fire-retardant plastic (UL 94-5VA)
Hardware
LED transmit, receive, power indicators ─ ─
®
LON network jack ─ ─
Integrated DIN rail mounting (separable base plate) ─ ─
Heating Output Configuration
Duct / primary stages 4 2 4
3 4 4 4
Perimeter / secondary stages 4 2 4
Duct modulating valve
Perimeter modulating valve
www.distech-controls.com
ECC-VAVS
ECC-PFCU
EC-HPU-L
EC-FCU-L
EC-RTU-L
ECC-VAV
EC-UV-L
Heating Output Configuration (continued)
Duct floating actuator valve
Perimeter floating actuator valve
Cooling Output Configuration
Duct / primary stages 4 2 4 3 4 4 4
Secondary stages ─ ─ 4 ─ ─ ─ ─
Duct modulating valve ─
Duct floating actuator valve
Reversing valve (heat pump) ─ ─
Heat pump condenser water pump ─ ─ ─ ─ ─ ─
Heating / Cooling Output Configuration (2 pipes)
On / off (2 position) ─ ─ ─ ─
Duct modulating valve
Duct floating actuator valve
Fan Control
Speeds 1 1 3 3 1 3 3
Modulating fan drive ─ ─
State input ─ ─
Speed selector input ─ ─ ─
Damper Control
External damper (modulating / floating) ─ ─ ─ ─ ─ ─
Modulating fresh air / economizer ─ ─ ─ ─ ─
Floating fresh air / economizer ─ ─ ─ ─ ─
Bypass damper ─ ─ ─ ─ ─ ─
Humidification / Dehumidification
On / off (2 positions) ─ ─ ─
Modulating valve ─ ─ ─
Floating valve ─ ─ ─ ─ ─ ─
Temperature Input
Space
Duct (before the terminal unit) ─ ─ ─ ─ ─
Supply / discharge
5 5 5
Outdoor
Water supply
Return air ─ ─ ─ ─
Mixed air ─ ─ ─ ─ ─
Refrigerant ─ ─ ─ ─ ─ ─
Setpoint (absolute) ─ ─ ─ ─
Setpoint offset (relative)
Humidity
Space ─ ─ ─
Outdoor ─ ─ ─ ─ ─
Enthalpy
Space ─ ─ ─ ─ ─
Outdoor ─ ─ ─ ─ ─
ECC-PFCU
EC-HPU-L
EC-FCU-L
EC-RTU-L
ECC-VAV
EC-UV-L
Pressure Input
Discharge air pressure ─ ─ ─ ─ ─ ─
Duct air static pressure ─ ─ ─ ─ ─ ─
Refrigerant differential pressure (for defrost cycle) ─ ─ ─ ─ ─ ─
Box flow (differential pressure) o o ─ ─ ─ ─ ─
Contact Input
Occupancy
Bypass
Window ─
Economizer enabled ─ ─ ─ ─ ─
Emergency ─ ─
Coil frost ─ ─ ─ ─ ─ ─
Other
Minimum fresh air enabled ─ ─ ─ ─ ─
Economizer enabled ─ ─ ─ ─ ─
HVAC mode selector ─ ─
Light switch input ─ ─ ─ ─
C02 concentration ─ ─ ─ ─
Light switch output ─ ─ ─ ─
Occupancy state output ─ ─ ─ ─
Model Options
2 2
Open-to-Wireless ready o ─ ─ ─ ─
Built-in actuator o ─ ─ ─ ─ ─
6
Actuator feedback o ─ ─ ─ ─ ─
Pressure sensor o o ─ ─ ─ ─ ─
24V AC generation ─ ─ o ─ ─ ─ ─
o – Option - Feature
1.
Cannot use the EC-Smart-Sensor and wireless sensors Controller Naming Conventions:
simultaneously. ECP-203
2.
Wireless sensors can be used with the ECC-VAV and ECC-VAVS Application name:
controllers when they are connected to a Wireless Receiver. VAV, FCU, HPU, UV, PFCU, PTU, Etc.
3. Number:
Only the ECC-PFCU-A models have two universal outputs. 203
4.
The ECC-PFCU models have 8 network outputs. The ECC-PFCU- 0: UO
A models have 10 network outputs. 1: ½ DO, ½ UO
2: DO
5.
Able to input outdoor temperature indirectly via network variable 3: Other output cfg.
0: Standard
binding or by a turnaround binding. 1: With HOA
6. 2: Inputs only
The Actuator Feedback is built-in and not optional for all models 3: Outputs only
C: Configurable
P: Programmable