Sunteți pe pagina 1din 3

Configurable Controllers

Product Comparison ECC-VAVS: Small Single Duct Variable Air Volume


ECC-VAV: Single Duct Variable Air Volume
Sheet ECC-PFCU: Powered Fan Coil Unit
EC-FCU-L: Fan Coil Unit
EC-RTU-L: Roof Top Unit
EC-HPU-L: Heat Pump Unit
EC-UV-L : Unit Ventilator

ECC-VAVS

ECC-PFCU

EC-HPU-L
EC-FCU-L

EC-RTU-L
ECC-VAV

EC-UV-L
Inputs
Universal (total) 4 2 6 6 6 6 6
Digital (dry contact)
Voltage (0-10V)
Current (4-20mA with ext. 249Ω)
Thermistor (10kΩ Type 2)
Thermistor (10kΩ Type 3)
Platinum Pt1000 (1kΩ RTD) ─ ─ ─ ─
Platinum Pt100 (100Ω RTD) ─ ─ ─ ─
Nickel Ni1000 (1kΩ RTD) ─ ─ ─ ─ ─ ─
Potentiometer (transtable)
Software configurable
Ability to use spare inputs
1,2 1,2
Optional wireless inputs 6 4 5 ─ ─ ─ ─
1 1
EC-Smart-Sensor capability ─ ─ ─ ─
Analog/digital converter (bit) 16 16 16 12 12 12 12
Outputs
3
Universal (analog) 2 ─ 2 2 2 2 2
Digital (relay) ─ ─ 4 ─ ─ ─ ─
Digital (triac) 4 2 4 5 5 5 5
4
Network (using NVOs) 6 2 8/10 ─ ─ ─ ─
Ability to use spare outputs (NVIs)
Output LED status indicators ─ ─ ─
Digital/analog converter (bit) 10 10 10 8 8 8 8
Power Input
24V AC ─
85-265V AC ─ ─ ─ ─ ─ ─
Enclosure
Fire-retardant plastic (UL 94-5VA)
Hardware
LED transmit, receive, power indicators ─ ─
®
LON network jack ─ ─
Integrated DIN rail mounting (separable base plate) ─ ─
Heating Output Configuration
Duct / primary stages 4 2 4
3 4 4 4
Perimeter / secondary stages 4 2 4
Duct modulating valve
Perimeter modulating valve

www.distech-controls.com
ECC-VAVS

ECC-PFCU

EC-HPU-L
EC-FCU-L

EC-RTU-L
ECC-VAV

EC-UV-L
Heating Output Configuration (continued)
Duct floating actuator valve
Perimeter floating actuator valve
Cooling Output Configuration
Duct / primary stages 4 2 4 3 4 4 4
Secondary stages ─ ─ 4 ─ ─ ─ ─
Duct modulating valve ─
Duct floating actuator valve
Reversing valve (heat pump) ─ ─
Heat pump condenser water pump ─ ─ ─ ─ ─ ─
Heating / Cooling Output Configuration (2 pipes)
On / off (2 position) ─ ─ ─ ─
Duct modulating valve
Duct floating actuator valve
Fan Control
Speeds 1 1 3 3 1 3 3
Modulating fan drive ─ ─
State input ─ ─
Speed selector input ─ ─ ─
Damper Control
External damper (modulating / floating) ─ ─ ─ ─ ─ ─
Modulating fresh air / economizer ─ ─ ─ ─ ─
Floating fresh air / economizer ─ ─ ─ ─ ─
Bypass damper ─ ─ ─ ─ ─ ─
Humidification / Dehumidification
On / off (2 positions) ─ ─ ─
Modulating valve ─ ─ ─
Floating valve ─ ─ ─ ─ ─ ─
Temperature Input
Space
Duct (before the terminal unit) ─ ─ ─ ─ ─
Supply / discharge
5 5 5
Outdoor
Water supply
Return air ─ ─ ─ ─
Mixed air ─ ─ ─ ─ ─
Refrigerant ─ ─ ─ ─ ─ ─
Setpoint (absolute) ─ ─ ─ ─
Setpoint offset (relative)
Humidity
Space ─ ─ ─
Outdoor ─ ─ ─ ─ ─
Enthalpy
Space ─ ─ ─ ─ ─
Outdoor ─ ─ ─ ─ ─

Configurable Controllers www.distech-controls.com


ECC-VAVS

ECC-PFCU

EC-HPU-L
EC-FCU-L

EC-RTU-L
ECC-VAV

EC-UV-L
Pressure Input
Discharge air pressure ─ ─ ─ ─ ─ ─
Duct air static pressure ─ ─ ─ ─ ─ ─
Refrigerant differential pressure (for defrost cycle) ─ ─ ─ ─ ─ ─
Box flow (differential pressure) o o ─ ─ ─ ─ ─
Contact Input
Occupancy
Bypass
Window ─
Economizer enabled ─ ─ ─ ─ ─
Emergency ─ ─
Coil frost ─ ─ ─ ─ ─ ─
Other
Minimum fresh air enabled ─ ─ ─ ─ ─
Economizer enabled ─ ─ ─ ─ ─
HVAC mode selector ─ ─
Light switch input ─ ─ ─ ─
C02 concentration ─ ─ ─ ─
Light switch output ─ ─ ─ ─
Occupancy state output ─ ─ ─ ─
Model Options
2 2
Open-to-Wireless ready o ─ ─ ─ ─
Built-in actuator o ─ ─ ─ ─ ─
6
Actuator feedback o ─ ─ ─ ─ ─
Pressure sensor o o ─ ─ ─ ─ ─
24V AC generation ─ ─ o ─ ─ ─ ─
o – Option - Feature
1.
Cannot use the EC-Smart-Sensor and wireless sensors Controller Naming Conventions:
simultaneously. ECP-203
2.
Wireless sensors can be used with the ECC-VAV and ECC-VAVS Application name:
controllers when they are connected to a Wireless Receiver. VAV, FCU, HPU, UV, PFCU, PTU, Etc.
3. Number:
Only the ECC-PFCU-A models have two universal outputs. 203
4.
The ECC-PFCU models have 8 network outputs. The ECC-PFCU- 0: UO
A models have 10 network outputs. 1: ½ DO, ½ UO
2: DO
5.
Able to input outdoor temperature indirectly via network variable 3: Other output cfg.
0: Standard
binding or by a turnaround binding. 1: With HOA
6. 2: Inputs only
The Actuator Feedback is built-in and not optional for all models 3: Outputs only

that have a built-in actuator. Application size


1: ≤10 points
2: 11-15 points
3: 16-20 points
4: 21-25 points
5: 26-30 points
6: >30 points

C: Configurable
P: Programmable

Specifications subject to change without notice.


This comparison sheet is simply an overview of the featured products. For detailed information on these products, refer to their respective
datasheets. In the case of differing information between the comparison sheet and the datasheet(s), the datasheet is considered to be correct.
Distech Controls and the Distech Controls logo are trademarks of Distech Controls, Inc.; LON is a trademark of Echelon Corporation.

*05DI-DSCSASC-30* Configurable Controllers www.distech-controls.com


05DI-DSCSASC-30

S-ar putea să vă placă și