Load Data Sheet

from Caesar to Pipng Load plan


Issued by: SPEL-ME
Effective as of: 2008-03-12
Title:
Load Data Sheet Generation

SG No.: Pages: 5 Appendices:


Handling Instructions:
FOR SIEMENS INTERNAL USE ONLY

1. Following steps are to be used for generating load data sheet from Caesar
Stress analysis output:

1.1 Restraint Summary in 80 columns [132 columns unchecked] with all the relevant
load cases will be copied from the stress analysis output:

unchecked

Released:
Reviewed:
Prepared by: M K. Singh SPEL-ME 2008.03.12
Name Org. Unit Signature Date

Siemens AG . Power Generation (KWU) The reproduction, transmission or use of this document or its
contents is not permitted without express written authority. Offenders
will be liable for damages. All rights, including rights created by
patent grant or registration of a utility model or design, are reserved.

H30-K5014 Anweisung/Richtlinie, engl. KWU 04.99 D97 L:\DPT_ProjGroup_ME\Standardisation\Civil_load_data\Load Data Caesar.doc


Load Data Sheet No.:
from Caesar to Pipng Load plan Index:
Page: 2

1.2 Only data is to be copied as shown below:

Do not copy these text (load cases)

1.3 Copied data is to be pasted in “ResSum” and “ HydroLoad”. Steam hammer data if
applicable will be copied similarly and pasted to “ SteamHammer” worksheet of the
excell file “Arrange_Loaddata.xls”.

Siemens AG . Power Generation (KWU) The reproduction, transmission or use of this document or its
contents is not permitted without express written authority. Offenders
will be liable for damages. All rights, including rights created by
patent grant or registration of a utility model or design, are reserved.

H30-K5014 Anweisung/Richtlinie, engl. KWU 06.98 D L:\DPT_ProjGroup_ME\Standardisation\Civil_load_data\Load Data Caesar.doc


Load Data Sheet No.:
from Caesar to Pipng Load plan Index:
Page: 3

1.4 Once data pasted in excel sheet, Press “CTRL+A”. Marco will start running and
ask for selection of various load cases as below:

Siemens AG . Power Generation (KWU) The reproduction, transmission or use of this document or its
contents is not permitted without express written authority. Offenders
will be liable for damages. All rights, including rights created by
patent grant or registration of a utility model or design, are reserved.

H30-K5014 Anweisung/Richtlinie, engl. KWU 06.98 D L:\DPT_ProjGroup_ME\Standardisation\Civil_load_data\Load Data Caesar.doc


Load Data Sheet No.:
from Caesar to Pipng Load plan Index:
Page: 4

1.5 Load case numbers are to be selected in the above form, keeping in mind which
load is to be transferred to the datasheet. e.g. for pure earthquake load; load case
32 is to be selected, whereas, L32=L14-L6 and L14= W+D2+T2+P2+H+U1 & L6=
W+D2+T2+P2+H and so on….

1.6 Nest form appear will be as below:

Do not select any margin/safety factor (i.e. 0%) as margin will be considered by
the Civil Designer. (This is only for load plan used inhouse. For Load plan to be sent
to external agency suitable margin will be added).

2. Please check/prepare the load data as per the note given at the end of the load data
sheet. Also do not delete these notes. Notes are as below:
2.1 All Forces are in kN until and unless specified.

2.2 G= Permanent load (Sustained and Maximum of operating)

2.3 Q= Hydro Test load (Water weight only). It has been derived by substracting Caesar sus-
tained load case values from Caesar hydrotest load case values.

2.4 F= Maximum horizontal forces in Operating and sustained cases.

Siemens AG . Power Generation (KWU) The reproduction, transmission or use of this document or its
contents is not permitted without express written authority. Offenders
will be liable for damages. All rights, including rights created by
patent grant or registration of a utility model or design, are reserved.

H30-K5014 Anweisung/Richtlinie, engl. KWU 06.98 D L:\DPT_ProjGroup_ME\Standardisation\Civil_load_data\Load Data Caesar.doc


Load Data Sheet No.:
from Caesar to Pipng Load plan Index:
Page: 5

2.5 X, Y and Z are the direction of forces and is the global coordinate system of the project.

2.6 Sustained load consists of material, inline component and insulation weights. However, for
water filled lines, it also contains water weight.

2.7 Opearting loads are not pure thermal loads and they also include sustained loads.

2.8 Occasional forces (except safety valve reaction) e.g., Wind, Seismic and steam hammer
forces to be applied with reversal of Direction.

2.9 All occasional loads are pure loads and does not include operating loads.

2.10 No margins are added to the piping loads. Loads are actual loads from Caesar (Stress
analysis). Civil designer to add suitable margins for his design.

2.11 Load values smaller than 1 kN are ignored.

2.12 Combination of above loads are to be carried out by Structural Designer.

2.13 Refer Load plans for the location of the load points.

***

Siemens AG . Power Generation (KWU) The reproduction, transmission or use of this document or its
contents is not permitted without express written authority. Offenders
will be liable for damages. All rights, including rights created by
patent grant or registration of a utility model or design, are reserved.

H30-K5014 Anweisung/Richtlinie, engl. KWU 06.98 D L:\DPT_ProjGroup_ME\Standardisation\Civil_load_data\Load Data Caesar.doc