ON-SITE INSTALLATION CHECK LIST (SUPERVISOR & COOPERATORS)

Date: Site Name/Logistic Code: Address:

Cooperator: Supervisor:

Telephone Supervisor: Huawei's PM:

1-Pre-Check (Supervisor) PASS FAIL N/A


1-1 Engineering documentation available at site
1-2 Site survey document available at site
Site made ready (SMR) for installation from Customer, as per Site survey
1-3
recommendations
Site equipment received, checked and report made (if missing any) for Huawei's
1-4
PM
1-5 Installation equipment (Site master, power meter etc) present at site

2-GENERAL (Supervisor & Cooperator) PASS FAIL N/A


2-1 The cabinet is placed as per engineering documents
The cabinet is mounted properly on the concrete base. After the installation, the
2-2
cabinet is leveled and stands firmly on the ground.

2-3 The antistatic wrist-strap is inside the cabinet and connected to the ESD port
The horizontal error of the cabinet is less than 3 mm and the vertical error is not
2-4
more than 3 mm
All screws are securely fastened. The spring washers are installed on the flat
2-5
washers
The surface of the cabinet is clean and tidy. All the labels on the surface are
2-6
correct, readable, and intact

The front door of the cabinet is easy to open and close and the paint job of the
2-7
cabinet is not damaged (while opening/closing the door)
2-8 The cabinet is fully isolated from the floor
The cabinet is fully sealed (water tight) and seal adhesives are applied on the
2-9
holes/outlets of the cabinet
The site environment is cleaned (after BTS installation) from any waste and left-
2-10
over material
2-11 The internal cabling and board configuration are as per engineering documents
The side power equipment is well secured to the floor and is located on the side
2-12
of the BTS cabinet (for indoor only)
After completion of Site installation, Pending items list (snag list) prepared (if
2-13
any)

2-14 The SUPERVISOR to paste/put the Customer’s inventory label/sticker (called


SIR) on each board/cabinet, installed at each site and make an inventory list of
all the SIR label numbers corresponding to Huawei’s labels numbers

3-TRANSMISION (Supervisor & Cooperator) PASS FAIL N/A


3-1 E1 trunk cables fixed to cable trays and ladders
3-2 Good cable route from transmission equipment to BTS (with cable ties)
3-3 E1 trunk cable cut with suggested redundancy length
3-4 E1 pair connectors (towards DDF) are made professionally
3-5 E1 trunk cable properly identified (towards BTS)
3-6 E1 pair cable properly identified (towards DDF)
3-7 E1 pairs connected to DDF
3-8 E1 trunk cables connected to BTS professionally
3-9 DDF Box fixed to the wall
3-10 Cable connectors are professionally done and cover with heat shrink

3-11 The DCSU board DIP switch is in the correct position (75ohm or 120ohm)
3-12 The E1 is labeled on both sides (both ends)

4-ALARMS (Supervisor & Cooperator) PASS FAIL N/A


4-1 Alarm Box fixed to wall as per engineering documents
4-2 Alarm Box cables fixed to cable trays and ladders as per engineering documents
4-3 Alarm cables terminal connectors are made professionally
4-4 Alarm cables interconnection done professionally as per engineering documents
4-5 Alarm cables connected to BTS side.
4-6 Alarm cables connected to Alarm Box
4-7 The alarm cables are well identified in the Alarm Box.
4-8 Alarm cables connected to DEMU board and well identified
Alarm cables connected to the alarm sensors as per engineering documents
4-9
5-POWER (Supervisor & Cooperator) PASS FAIL N/A
The Side Power is installed properly, all the PSU and connections are done
5-1
professionally and the equipment is working as per requirements (for indoor only)
5-2 Cable color code is according to the standard
5-3 DC cables fixed to cable trays and ladders
5-4 DC terminal connectors (to BTS side) are completed
5-5 DC terminal connectors (to side power) side are completed (for indoor only)
5-6 DC terminal connectors (to rectifier/PDF side) are completed
5-7 DC cable connected to BTS side
5-8 DC cable connected to side power side (for indoor only)
5-9 DC cable connected to rectifier side
5-10 DC cables identified towards BTS
5-11 DC cables identified towards side power
5-12 DC cables identified towards rectifier side
5-13 All the terminals are well covered with heat shrink

6-GND SYSTEM (Supervisor & Cooperator) PASS FAIL N/A


6-1 GND cable fixed to cable trays and ladders
6-2 GND terminal connector (to BTS side) completed
6-3 GND terminal connector to grounding bar (MGB) side completed

6-4 GND terminal connector to Side Power side completed (for indoor only)

6-5 GND cable connected & identified to BTS


6-6 GND cable connected to bar (MGB) or crimped to ring.
6-7 GND cable connected to Side Power (for indoor only)
6-8 GND cable between Main and Slave cabinet completed and connected
6-9 GND cables identified (to grounding bar side)
6-10 GND cable are run through a protective pipe (PVC)
6-11 All the terminals are well covered with heat shrink
6-12 The DDF grounding cable are installed professionally
6-13 The grounding resistance (<5 Ohms)
Cables and connectors to AGB bars is done professionally, where applicable as
6-14
per Customer instructions
7-SYSTEM ANTENNA AND RF (Supervisor & Cooperator) PASS FAIL N/A
7-1 BTS boards cabling interconnection done as per engineering documents
7-2 RF jumper connector (towards RF feeder) completed
7-3 RF jumper connectors (towards BTS port on DDPU) completed
7-4 RF jumper identified towards BTS cabinet
7-5 RF jumper identified towards RF feeder (towards feeder cable side)
7-6 RF jumper fixed to trays and ladders
7-7 Support for RF antenna fixed on tower/steel pole
Waterproofing and sealing for all outdoor jumpers and feeder cables are as per
7-8
"antenna system installation" guide
Feeder cables don't cross each other and the degrees of bending are same for
7-9
all feeders
7-10 RF jumper (Antenna side) identified and fixed
7-11 RF Feeder connectors completed
7-12 RF Feeder fixed along tower/steel pole

7-13 RF Feeder identified at the bottom (towards BTS) and top (towards antenna)
RF Feeder grounding clips connected at top, bottom and before the BTS to the
7-14
MGB (for less than 60m tower).
7-15 Grounding clips connected at the middle (for more than 60m tower).
7-16 Grounding clips attached to feeder are made waterproof
7-17 Distance between feeder clamps is 1.5m to 2m
7-18 Each RF path is well connected and identified
Antennas placement should be in the 45-degree protected area of the lightning
7-19
rod

The azimuth and tilt angle of the installed antenna should be as per engineering
7-20 design specifications and should not be more than ± 5 degrees. The tilt angle
error should not be more than ± 0.5 degrees

7-21 The Omni antenna should be vertical with error less than ± 2 degrees.
The VSWR test result is as per requirement (1.2db or less) and the test results
7-22
ready to be provided to Huawei's PM
7-23 The Paint for the cable feeders and the jumpers are done professionally

The SUPERVISOR will check the Support/Mounting for the GSM antenna (If
required for a site). In case the GSM antenna cannot be installed with the CDMA
7-24
existing antenna (due to space constrain), a new mounting (as defined by
Customer) will be installed by the COOPERATOR
The SUPERVISOR will make sure that the original orientation (angle, height,
7-25 direction and azimuth) of the CDMA antenna remains unchanged, after new
mounting installation

8- Testing & Commissioning (Supervisor) PASS FAIL N/A


8-1 Commissioning guide and tools available at Site
After completion of installation (BTS powered up, Cards internal test completed
8-2 & TX connected), test and commission the BTS as per Huawei’s Commissioning
guide/instructions

8-3
Follow the acceptance protocol/procedure provided by Huawei PM
8-4
Verify the communication between the BTS (Site) and the associated BSC
8-5 Put Site in service

9-Documentation (Supervisor & Cooperator) PASS FAIL N/A


Cooperator performs a self check and complete the Site quality check list (this
9-1
document)

Supervisor completes the FINAL Site quality check list (this document) and get it
9-2
signed by the Cooperator to be submitted to Huawei’s PM
9-3 Cargo Problems Feedback Form
9-4 Installation environment check list
9-5 Antenna VSWR and TRX power test record table
9-6 Equipment Installation Report (GSM BTS)
9-7 Preliminary Acceptance Test (PAT)
9-8 Pictures of all Installation work and equipment, as per SOW
Send to Huawei the Installation Report including all the required inventory
9-9
information
Inventory list of all the SIR label numbers corresponding to Huawei’s labels
9-10
numbers to be submitted to Huawei's PM

__________________________________ _____________________________________
SIGNATURE FOR Cooperator SIGNATURE FOR Huawei (Supervisor)

__________________________________ _____________________________________
(Cooperator's Representative Name) (Huawei's Representative Name)

__________________________________ ____________________________________
Date Date
LIST (SUPERVISOR & COOPERATORS)

ess:

ervisor:

wei's PM:

OBSERVATIONS (Please provide comments, in any)

OBSERVATIONS (Please provide comments, in any)


OBSERVATIONS (Please provide comments, in any)