Before using your air conditioner, please read

this manual carefully and keep it for future reference.

SPLIT-TYPE
ROOM AIR CONDITIONER

The design and specifications are subject to change without prior notice for
product improvement. Consult with the sales agency or manufacturer for details.
Read This Manual
Inside you will find many helpful hints on how
to use and maintain your air conditioner properly.
Just a little preventative care on your part can
CS096U-C10 save you a great deal of time and money over
202000192232 the life of your air conditioner. You'll find many
answers to common problems in the chart of
20110618 troubleshooting tips. If you review the chart of
Troubleshooting Tips first, you may not need
to call for service.

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn


SOCIABLE REMARK

CONTENTS When using this air conditioner in the European countries, the following
informations must be followed:
SOCIABLE REMARK
Sociable remark.......................................................................................................................2 DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary.
SAFETY PRECAUTIONS
Warning ..................................................................................................................................3 It is prohibited to dispose of this appliance in domestic household waste.
Caution ...................................................................................................................................4 For disposal, there are several possibilities:
A) The municipality has established collection systems, where electronic waste can
OPERATING INSTRUCTIONS be disposed of at least free of charge to the user.
Parts names ........... ...............................................................................................................5 B) When buying a new product, the retailer will take back the old product at least
Special functions .....................................................................................................................6 free of charge.
Operating temperature.............................................................................................................7 C) The manufacture will take back the old appliance for disposal at least free of
Manual operation ....................................................................................................................7
charge to the user.
Airflow direction control ..........................................................................................................8
How the air conditioner works ................................................................................................9 D) As old products contain valuable resources, they can be sold to scrap metal
dealers.
CARE AND MAINTENANCE Wild disposal of waste in forests and landscapes endangers your health when
hazardous substances leak into the ground-water and find their way into the food
Care and maintenance ..........................................................................................................10
chain.

OPERATION TIPS
Operation tips ............ ..........................................................................................................12

TROUBLESHOOTING TIPS
Troubleshooting tips .............................................................................................................14

CAUTI ON
Contact an authorised service technician for repair or maintenance of this unit.
Contact the authinstaller for installation of this unit.
This appliance is not intended for use by persons(including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Young children should be supervised to ensure that they do not play with the
air conditioner.
If the power cord is to be replaced, replacement work shall be performed by
authorised personnel only.
Installation work must be performed in accordance with the national wiring
standards by authorised personnel only.

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn


SAFETY PRECAUTIONS SAFETY PRECAUTIONS

To prevent injury to the user or other people and property damage, the following instructions
must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The seriousness is classified by the following indications. CAUTION

WARNING This symbol indicates the possibility of death or serious injury. Do not clean the air Ventilate the room well
When the air filter is to be
removed, do not touch the conditioner with water. when used together
CAUTION This symbol indicates the possibility of injury or damage to property. metal parts of the unit. with a stove, etc.

It may cause an injury. Water may enter the unit and An oxygen shortage
Meanings of symbols used in this manual are as shown below. degrade the insulation. It may may occur.
cause an electric shock.
Never do this.
When the unit is to be Do not put a pet or house Do not use for
cleaned, switch off, and turn plant where it will be special purposes.
Always do this. off the circuit breaker. exposed to direct air flow.

Do not clean unit when This could injure the pet or Do not use this air cond-
WARNING power is on as it may cause plant. itioner to preserve preci-
fire and electric shock, it may sion devices, food, pets,
Connect with the power Do not operate or stop the Do not damage or use an plants, and art objects.
properly. unit by switching on or off unspecified power cord. cause an injury. It may cause deterioration
the power. of quality, etc.
Otherwise, it may cause electric It may cause electric shock or fire It may cause electric shock Stop operation and close Do not place obstacles Turn off the main power
shock or fire due to excess heat due to heat generation. or fire. the window in storm or around air-inlets or inside switch when not using
generation. hurricane. of air-outlet. the unit for a long time.
Do not modify power cord Do not operate with wet Do not direct airflow at
hands or in damp room occupants only. Operation with windows It may cause failure of It may cause failure of
length or share the outlet product or fire.
environment. opened may cause wetting appliance or accident.
with other appliances
of indoor and soaking of
It may cause electric shock It may cause electric shock. This could damage your household furniture.
or fire due to heat generation. health.
Always ensure effective Do not allow water to run Always install circuit Do not use strong detergent Ensure that the installation bracket of Always insert the filters
earthing. into electric parts. breaker and a dedicated such as wax or thinner. Use the outdoor appliance is not damaged securely. Clean filter
power circuit. a soft cloth for cleaning. due to prolonged exposure. once every two weeks.
No earthing may cause It may cause failure of No installation may cause
electric shock. machine or electric shock. fire and electric shock. Appearance may be If bracket is damaged, there Operation without filters
deteriorated due to change is concern of damage due to may cause failure.
Disconnect the power if Do not drink water drained Do not open the unit of product color or falling of unit.
strange sounds, smell, or from air conditioner. during operation.
scratching of its surface.
smoke comes from it.
It may cause fire and It contains contaminants and It may cause electric shock. Do not place heavy object on the Use caution when unpacking If water enters the
electric shock. could make you sick. power cord and take care so that and installing. Sharp edges unit, turn the unit off
Use the correctly rated Do not use the power cord Do not disassemble or the cord is not compressed. could cause injury. and disconnect the
breaker or fuse. close to heating appliances. modify unit. power , contact a
There is danger of fire or qualified service
electric shock. technician.
There is risk of fire or It may cause fire and It may cause failure and
electric shock. electric shock. electric shock.
Ventilate room before operating air Do not use the power cord near
conditioner if there is a gas leakage flammable gas or combustibles, such
from another appliance. as gasoline, benzene, thinner, etc.
It may cause explosion, fire and, burns. It may cause an explosion or fire.

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn


OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS

Parts names TIMER indicator


LED display panel This indicator illuminates when
Indoor unit NOTE: The display panel of the indoor unit may be TIMER program is set ON/OFF.
look like one of the following:
NOTE: The indoor unit you purchase may be look
Indoor unit AUTO indicator
like one of the following:
4
1 2 1. Display panel This indicator illuminates when
3 2. Panel frame the air conditioner is in AUTO
3. Chassis operation.
4. Front panel
5. Horizontal louver OPERATION indicator
6. Vertical louver(on some models) Signal This indicator flashes after power
7. Air filter(under the panel) receptor
(1) is on and illuminates when the unit
8. Manual control button
6 5 8 is in operation.
9. Remote controller holder
10. Remote controller TEMPERATURE indicator
11. Connecting pipe Displays the temperature settings or
11 12 12. Drain hose malfunction codes when the air
7
conditioner is operational.
9 10
Signal
receptor DEFROST indicator
(A) (2) (For Cooling & Heating models only)
This indicator illuminates when
the air conditioner starts defrosting
automatically or when the warm air
control feature is activated in heating
operation.

Signal CLEAN AIR indication lamp


receptor (3) (on some models):
NOTE: Lights up when CLEAN AIR feature is
All the pictures in this manual
activated.
are for explanation purpose
(B) only. Your air conditioner may
be slightly different.
The actual shape shall prevail.
Special function
Outdoor unit
CLEAN AIR function
Improving the quality of indoor air is one of the mission of an air conditioner.
Air inlet(rear)
This air conditioner is equipped with ionizer or Plasma Dust Collector (Depending on
Air inlet(side)
Outdoor unit specific configuration of the model). With the anions generated by Ionizer, the air
circulation of the air conditioner fills the room with refreshing, natural and healthy air. The
13. Connecting cable Plasma Dust Collector generates an high voltage ionization zone, through which the air is
14. Connective pipe converted to plasma. Inside the air most of the dust, smoke, and pollen particles are captured
13 15. Stop valve by the electrostatic filter.
Air outlet 14
15

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn


OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS

NOTE: This manual does not include Remote Controller Operations, see the Airflow direction control
<<Remote Controller Instruction>> packed with the unit for details.
Adjust the air flow direction properly otherwise, it
Operating temperature might cause discomfort or cause uneven room
temperatures.
Mode
Adjust the horizontal louver using the remote
Cooling operation Heating operation Drying operation controller.
Temperature
10 32 50 90 Adjust the vertical louver manually.
Room temperature
17 32 (<21000Btu/h models)
0 30
62 90 32 86 To set the vertical air flow(Up--Down) direction
17 32 62 90
( 21000Btu/h models) Range Perform this function while the unit is in operation.
Outdoor temperature 18 43 11 43 52 109 Use the remote controller to adjust the air flow
64 109 (<21000Btu/h models) direction. The horizontal louver can be moved at
O
-5 43 23 109 -7 24 18 43 64 109 a range of 6 for each press, or swing up and down
For the models with low 20 76 ( 21000Btu/h models)
,,
automatically. Please refer to the REMOTE
temperature cooling system ,,
21 52 70 126 CONTROLLER OPERATION MANUAL for details.
21 52 70 126
For special tropical models (For special tropical models) To set the horizontal air flow direction (left - right)
Move the vertical louver manually to adjust the air flow
NOTE: in the direction you prefer.
1. If air conditioner is used outside of the above conditions, certain safety protection features
IMPORTANT: Before adjusting the vertical louvers, the
may come into operation and cause the unit to function abnormally.
supply power must be disconnected.
2. Room relative humidity less than 80%. If the air conditioner operates in excess of this Vertical
louver For some models, the vertical louver can be adjusted
figure, the surface of the air conditioner may attract condensation. Please sets the vertical
(three places) by using the remote controller. Please refer to the ,,
air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode. ,,
REMOTE CONTROLLER OPERATION MANUAL
3. Optimum performance will be achieved within these operating temperature.
for details.

Manual operation CAUTION


Manul operation can be used temporarily in case the remote controller is disable or
maintenance necessary. Open and lift the front panel up to an angle Do not operate the air conditioner for long periods with
1
until it remains fixed with a clicking sound. the air flow direction set downward in cooling or
For some models, use the props under the dehumidifying mode. Otherwise, condensation may
occur on the surface of the horizontal louver causing
panel to hold the panel up.
Range moisture to drop on to the floor or on furnishings.
2 Push the button until the AUTO indicator
Manual control AUTO/COOL Do not move the horizontal louver manually unless it is
is lit, the unit will work in forced AUTO mode (the
button necessary. Always use the remote controller.
default setting temperature is 24℃/76OF). When the air conditioner is started immediately after it
(A)
3 Close the panel firmly to its original position(For was stopped, the horizontal louver might not move for
the panel with props, remember to take the props approximately 10 seconds.
down before closing the panel). Open angle of the horizontal louver should not be set
CAUTION: too small, as COOLING or HEATING performance may
● Once you push the manual button, the operation be impaired due to too restricted air flow area.
Props mode is shifted in an order as: AUTO, COOL, OFF. Do not operate unit with horizontal louver in closed
● The COOL mode is used for testing purposes only. position.
Manual control AUTO/COOL You had better not choose it. When the air conditioner is connected to power (initial
button ● To restore the remote controller operation, use the power), the horizontal louver may generate a sound for
(B) remote controller directly. 10 seconds, this is a normal operation.

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn


OPERATING INSTRUCTIONS CARE AND MAINTENANCE

How the air conditioner works Care and maintenance


AUTO operation
SLEEP operation When you set the air conditioner in AUTO mode, it will
7 hours timer off automatically select cooling, heating(cooling/heating Cleaning the Grille, Case and Remote Controller
models only), or fan only operation depending on what Turn the system off before cleaning. To clean, wipe with
temperature you have selected and the room a soft, dry cloth. Do not use bleach or abrasives.
Set temperature.
Temperature NOTE: Supply power must be disconnectd before
The air conditioner will control room temperature
automatically round the temperature point set by you. cleaning the indoor unit.
1 hour 1 hour
If the AUTO mode is uncomfortable, you can select
Cooling desired conditions manually.
CAUTIONS
SLEEP operation A cloth dampened with cold water may be used
SLEEP operation When you push SLEEP button on remote controller on the indoor unit if it is very dirty. Then wipe it
7 hours timer off during cooling, heating(cooling & heating models only), with a dry cloth.
or AUTO operation , the air conditioner will Do not use a chemically treated cloth or duster to
Set
automatically increase (cooling) or decrease (heating) clean the unit.
Temperature per hour for the first 2 hours, then hold Do not use benzine, thinner, polishing powder, or
steady for the next 5 hours, after that it will switch off. similar solvents for cleaning. These may cause
1 hour 1 hour This characteristic maintains both enery saving and the plastic surface to crack or deform.
comfort in night operation. Filter Handle Never use water hotter than 40 C/104OF to clean
Heating the front panel, it could cause deformation of
DRYING operation discoloration.
The temperature is regulated while dehumidifying by
repeating turning on and off of the cooling operation or
fan only. The fan speed is LOW.
Cleaning the air filter
Optimal operation A clogged air filter reduces the cooling efficiency of
To achieve optimal performance, please note the this unit. Please clean the filter once every 2 weeks.
following: 1. Lift the indoor unit panel up to an angle until it
Adjust the air flow direction correctly so that it is not stops with a clicking sound.
directed on people. 2. Take hold of the handle of the air filter and lift it
Adjust the temperature to achieve the highest comfort up slightly to take it out from the filter holder,

..
level. Do not adjust the unit to excessive temperature then pull it downwards.
levels. 3. Remove the AIR FILTER from the indoor unit.
Close doors and windows on COOL or HEAT modes, Clean the AIR FILTER once two weeks.
or performance may be reduced. Clean the AIR FILTER with a vacuum cleaner
Use TIMER ON button on the remote controller to or water, then dry it up in cool place.
select a time you want to start your air conditioner.
Do not put any object near air inlet or air outlet, as the
efficiency of the air conditioner may be reduced and
the air conditioner may stop running.
Clean the air filter periodically, otherwise cooling or
heating performance may be reduced.
Do not operate unit with horizontal louvre in closed
position.

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn


CARE AND MAINTENANCE OPERATION TIPS

The following events may occur during normal operation.


4. Remove the Air Freshening Filter from its support
1. Protection of the air conditioner.
frame (on some models).
Compressor protection
(The optional filter include :Plasma Dust Collector/
Silver Ion filter /Bio filter /Vitamin C filter/3M air The compressor can't restart for 3-4 minutes after it stops.
purifier filter, etc. The removing and installation Anti-cold air (Cooling and heating models only)
The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in

.
methods are slightly different, see the pictures
marked 1 and 2 on the left. one of the following three situations and the set temperature has not been reached.

.
Clean the air freshening filter at least once a A) When heating has just starting.
month, and replace it every 4-5 months. B) Defrosting.
Clean it with vacuum cleaner, then dry it in cool C) Low temperature heating.
place. The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).
1 Defrosting (Cooling and heating models only)
Do not touch the Plasma Dust Collector
Filter within 10 minutes after opening the Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low
front panel, it may cause an electric shock. and humidity is high resulting in lower heating efficiency of the air conditioner.
During this condition air conditioner will stop heating operation and start defrosting automatically.
5. Install the air freshening filter back into position. The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and
6. Insert the upper portion of air filter back into the the amount of frost build up on the outdoor unit.
unit, taking care that the left and right edges line
up correctly and place filter into position. 2. A white mist coming out from the indoor unit
A white mist may generate due to a large temperature difference between air inlet and air outlet
on COOL mode in an indoor environment that has a high relative humidity.
Maintenance A white mist may generate due to moisture generated from defrosting process when the air
conditioner restarts in HEAT mode operation after defrosting.
If you plan to idle the unit for a long time, perform
2 the following:
3. Low noise of the air conditioner
(1) Operate the fan for about half a day to dry the
You may hear a low hissing sound when the compressor is running or has just stopped running.
inside of the unit.
(2) Stop the air conditioner and disconnect power. This sound is the sound of the refrigerant flowing or coming to a stop.
Remove the batteries from the remote controller. You can also hear a low "squeak" sound when the compressor is running or has just stopped
(3) The outdoor unit requires periodic maintenance running. This is caused by heat expansion and cold contraction of the plastic parts in the unit
and cleaning. Do not attempt to do this yourself. when the temperature is changing.
Contact your dealer or servicer. A noise may be heard due to louver restoring to its original position when power is first turned on.
Checks before operation 4. Dust is blown out from the indoor unit.
Check that the wiring is not broken off or This is a normal condition when the air conditioner has not been used for a long time or during first
disconnected. use of the unit.
Check that the air filter is installed.
Check if the air outlet or inlet is blocked after the 5. A peculiar smell comes out from the indoor unit.
air conditioner has not been used for a long time. This is caused by the indoor unit giving off smells permeated from building material, from furniture,
or smoke.
Caution

Do not touch the metal parts of the unit when 6. The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and
removing the filter. Injuries can occur when heating models only) mode.
handling sharp metal edges. When indoor temperature reaches the temperature setting on air conditioner, the compressor will
Do not use water to clean inside the air conditioner. stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again
Exposure to water can destroy the insulation, when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating
leading to possible electric shock. models only) to the set point.
When cleaning the unit, first make sure that the
power and circuit breaker are turned off.

PDF 文件使用 "pdfFactory" 试用版本创建 www.fineprint.cn


OPERATION TIPS TROUBLESHOOTING TIPS

7. Dripping water may generate on the surface of the indoor unit when cooling in a high Troubleshooting Tips
relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to
the maximum air outlet position and select HIGH fan speed. Stop the air conditioner immediately if one of the following faults occur. Disconnect the
power and contact the nearest customer service center.
8. Heating mode (For cooling and heating models only)
OPERATION indicator or other indicators flash rapidly (5 times every second) or
The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit
the OPERATION indicator and the TIMER indicator illuminate and remain on for one
during heating operation. When the outdoor temperature falls, heat drawn in by the air
conditioner decreases accordingly. At the same time, heat loading of the air conditioner second by turns, and this can't be fixed by disconnecting the power, and then
increases due to larger difference between indoor and outdoor temperature. If a Trouble connect it in again.
comfortable temperature can't be achieved by the air conditioner, we suggest you use a Fuse blows frequently or circuit breaker trips frequently.
supplementary heating device.
Other objects or water penetrate the air conditioner.
9. Auto-restart function
Power failure during operation will stop the unit completely. The remote controller won't work or works abnormally.
For the unit without Auto-restart feature, when the power restores, the OPERATION indicator Other abnormal situations.
on the indoor unit starts flashing. To restart the operation, push the ON/OFF button on the
remote controller. For the unit with Auto-restart feature, when the power restores, the unit
restarts automatically with all the previous settings preserved by the memory function. Malfunctions Cause What should be done?
For some models, the machine is special designed with Auto-restart function for the open angle Unit does not Power cut Wait for power to be restored.
of the horizontal louver.Power failure during operation or pressing the ON/OFF button on the
remote controller will stop the unit completely.When the power restores or pressing the ON/OFF start
Unit may have become unplugged. Check that plug is securely in wall
button on the remote controller again,the unit restarts automatically with all the previous settings receptacle.
including the open angle of the horizontal louver by the memory function.So we strongly suggest
that the open angle of the horizontal louver should not be set too small,in case the condensed Fuse may have blown. Replace the fuse.
water forms and drops from the horizontal louver. Press the AUTO/COOL button under the
front panel and the open angle of the horizontal louver will be restored to the standard angle Battery in Remote controller may Replace the battery.
when the condensed water forms on the horizontal louver. have been exhausted.

10. Lightning or a car wireless telephone operating nearby may cause the unit to malfunction. The time you have set with timer Wait or cancel timer setting.
Disconnect the unit with power and then re-connect the unit with power again. Push the is incorrect.
ON/OFF button on the remote controller to restart operation. Unit not cooling Inappropriate temperature Set temperature correctly. For
or heating setting. detailed method please refer to
(Cooling/ heating "Using remote control" section.
models only)
Air filter is blocked. Clean the air filter.
room very well
while air flowing Doors or Windows are open. Close the doors or windows.
out from the air Air inlet or outlet of indoor or Clear obstructions away first, then
conditioner outdoor unit has been blocked. restart the unit.

Compressor 3 or 4 minutes Wait.


protection has been activated.

If the trouble has not been corrected, please contact a local dealer or the nearest customer
service center. Be sure to inform them of the detailed malfunctions and unit model.

Notes: Do not attempt to repair the unit yourself.


Always consult an authorised service provider.