petrotest® Viscosity

Determination of Viscosity
ASTM D 445 - ASTM D 446 - IP 71 - ISO 3104 - ISO 3105 - DIN 51 561 - DIN 51 569
Full-View Viscometer Baths
Full-View Viscometer Bath, temperature range + 5 ... + 60 °C,
comprising of:
30 l acrylic glass tank of rectangular shape with cover plate to
accommodate 4 viscometers of Ubbelohde, Cannon-Fenske or
BS/IP-U-Tube type.
Thermostat with analog temperature setting and digital
temperature reading (LED), Pt 100 sensor, pump stirrer,
cooling coil, over-temperature and low-level protection.
Required bench space: 280 x 430 mm.
Temperature accurate within 0.01 °C.
Heater capacity 2000 W
20-0000 For 230 V, 50/60 Hz
20-0001 For 115 V, 50/60 Hz
High Temperature Liquid Bath 150
digital temperature read-out, 7 test places (∅ 50 mm)
and front window (270 x 285 mm).
Working range: from +5°C above ambient or cooling water
up to +150 °C
Constant : 0.03 K
Calibration : 0.1°C increment
20-0000/22-0175 Stability : ± 0.02°C and better (with water at 90°C)
Capacity : 40 liters
Bath opening: 260 x 240 mm
Bath depth: 300 mm
Bench space: 280 x 430 mm.
20-0150 For 230 V, 50/60 Hz, 1500 W
20-0151 For 115 V, 50/60 Hz, 1500 W

Low Temperature Viscometer Bath


Low Temperature Viscometer Bath
Dewar flask, cap. 25 liters, placed in a stainless steel
housing (shock resistant). The Dewar flask has a window on
the back, were a fluorescent illuminator is placed
and a window of 14 cm width on the front. The front window
is heated to prevent condensation (up to 40°C and 85 % rel.
humidity). Top plate consists of special stirrer assembly,
heater, Pt-100 temperature probe, opening for immersion
cooler and lid (round form), which can accommodate
3 viscometers. Behind each Viscometer is a frosted glass
plate to provide diffused light (in combination with
illumination), a digital temperature meter
range: -80 ... + 50 :0.1 °C, accuracy of controller ±0.01 K,
power consumption: 920 Watts. External immersion cooler.
20-0002 20-0200 For 230 V, 50/60 Hz
20-0201 For 115 V, 50/60 Hz
Cooler KV 80 to cool down to -69 °C (bath fluid methanol)
20-0226 For 230 V, 50/60 Hz
20-0227 For 115 V, 50/60 Hz

Accessories
20-0030 Luminous background:
Large field lamp for convenient glare-free observation of the
viscometers immersed in the thermostatic bath.
For 230 V, 50/60 Hz
21-0697 Electronic digital stop watch, battery operated

Bath fluids - Silicon Oil based


5 liters 10 liters Temperature Range (approx.) Color
20-0200 50-9181 50-9191 - 60 ... + 65 °C slightly brown
50-9184 50-9194 +10 ... +200 °C slightly brown
50-9161 50-9162 +10 ... +200 °C water clear

Combined Brookfield / Scanning Brookfield Bath see page K 12

C1
Viscosity Petrotest®
ViscoClock

ViscoClock is an electronic time through time of the tested liquid is used at bath temperatures up to
measuring unit which provides an indicated on an easily legible LCD +150 °C, while the temperature for the
economically priced alternative to fully display and can also be recorded on a time measuring unit shall be between
automatic capillary viscometer devices. printer or a PC. +10 and +40 °C.
It consists of a stand made of plastics The ViscoClock can be placed in ViscoClock, however, accepts
to hold the viscometer capillary and of Petrotest viscosity baths particularly designed Ubbelohde
an electronic time measuring unit. The 20-0000/0001 or 20-0002/0003 and capillaries with measuring ranges
two measuring levels are integrated in allows the use of water, alcohol/water between 0.35 and 10,000 mm² (cSt)
the stand in form of a light barrier. They mixture(e.g. ethanol or methanol) only.
control the start or stop resp. of the paraffin oil or silicone oil. It can be
timer. This way the measured flow-

ViscoClock - Automated Measuring Device


for Ubbelohde Viscometer Capillaries
consisting of an electronic time measuring unit in a plastic housing
with a large LCD indication (resolution = 0.01 sec.) and of a plastic
frame for Ubbelohde capillaries with sensors to measure the flow-
through time of the tested liquid.
The device can be inserted in tempering baths which are filled
with water, alcohol/water (e.g. ethanol or methanol), paraffin oils
or silicon oil.
Permitted temperatures are -40 to +150 °C for the tempering bath
and ambient temperatures between +10 and +40°C for the clock.
Measuring range:
with Ubbelohde capillaries1 0.35 ... 10 000 mm²/s (cSt).
Timer: up to 999.99 seconds, resolution 0.01 s.
accuracy ± 0.01 s/± 1 digit, however min. 0.1 %
Data output to measurement printer or PC via RS 232-C interface
22-0175 Compl. with power pack for 230 V, 50/60Hz
22-0176 Compl. with power pack for 115 V, 50/60Hz

22-0340 Set of ASTM-Ubbelohde Viscometer Capillaries


(10 pcs.each with manufacture’s certificate)
1 each of size 0, 0c, 0b, 1, 1c, 2, 2c, 3, 3c, 4
Viscosity range: 0.3 to 10,000 cSt or mm²/s
22-0350 Set of DIN-Ubbelohde Viscometer Capillaries
(9 pcs. with manufacturer certificate)
1 each of size 0, 0a, I, Ia, II, IIa, III, IIIa, IV
Viscosity range: 0.35 to 10,000 cSt or mm²/s
Accessories
Data transmission cable RS 232-C, 1.5 m in length,
22-0177 for printer connection with 25-core
22-0178 for PC connection with 25-core
22-0179 for PC connection with 9-core
22-0180 for PC connection with 9/25 pin adaptor

Hand pump assembly with adaptor and a hose of 25 cm in length


22-0181 ...
22-0182 "suction" - type
"pressure" - type
22-0175
Spare Parts
22-0183 Spare silicon stoppers, pack of 5
22-0184 Spare silicon membranes, pack of 5
22-0186 Spare power supply for 230 V
22-0187 Spare power supply for 115 V

For single viscometer capillaries see page C 5


1
Micro-Ubbelohde or Micro-Ostwald capillaries upon request

C2
Petrotest® Viscosity

Primary Officially Certified ISO 9001 Secondary Viscosity Oil Standards DIN
Viscosity Oil Standards Kinematic Viscosity (mm2/s) at
20°C 23°C 25°C 30°C 40°C 100°C
DIN 51 550
24-0501 1.2 1.2 1.1 1.0 0.94
24-0502 1.9 1.8 1.8 1.6 1.4
Primary Standards are mainly used to 24-0503 4.5 4.2 4.0 3.6 2.9
check indoor reference viscometers 24-0504 10 9.1 8.6 7.4 5.7
such as Ubbelhode, Cannon-Fenske 24-0505 19 17 16 13 9.6
and U-Tube Viscometers as well as 24-0506 50 43 40 32 22 4.7
for recalibrating other viscometers 24-0507 131 113 102 81 53 9.5
24-0508 342 289 260 201 126 18
24-0509 1038 821 705 492 256 21
24-0510 1170 970 860 640 375 42
For detailed 24-0511 2340 1914 1680 1230 693 66
24-0512 4580 3690 3210 2300 1250 76
information refer to 24-0513 9320 7070 5910 3850 1760 101
section 24-0514
24-0515
20050
49100
15130
37000
12600
30800
8100
19700
3600
8600
125
250
„Calibration Fluids“, Quantity: 500 ml
DKD1) Calibration Certificate: relative uncertainty between 0.3% and 0.7% of 1st value.
page Q 1
With Secondary Oil Standarsa all listed Factory Certified Viscosity Oil Standards ASTM D2162
values and temperatures are certified Kinematic Viscosity (mm2/s) approx. at
but to a lower level of certainty than 20°C 25°C 37.78°C 40°C 98.89°C 100°C Type
Primary Oil Standards. 68°F 77°C 100°C 104°F 210°F 212°F
24-0601 0.47 0.45 0.41 0.40 N
.4
All values stated in the following tables
24-0617 0.95 0.89 0.77 0.75 N
are to be considered as nominal values
.8
only. The actual and exact data may
24-0602 1.3 1.2 1.0 0.97 N 1
deviate in a certain degree and will
24-0603 4.6 4.0 3.0 2.9 1.2 S 3*
be either shown on the label of the
24-0604 11 8.9 6.0 5.7 1.8 1.8 S 6
container or on the pertinent test
24-0605 21 17 11 10 2.7 2.7 N 10
certificate.
24-0606 44 34 20 18 3.9 3.8 S 20
24-0607 87 66 35 32 5.4 5.3 N 35
24-0616 170 120 60 54 7.5 7.3 S 60
24-0608 330 230 110 97 11 11 N 100
24-0609 660 460 200 180 17 16 S 200
24-0610 1300 850 350 310 24 23 N 350
24-0611 2400 1600 600 520 34 33 S 600
24-0612 4800 3000 940 48 N 1000
24-0613 9600 5900 2000 1700 72 69 S 2000
24-0614 20000 12000 3400 120 N 4000
24-0615 41000 25000 8000 6700 240 S 8000
24-0618 89000 28000 23000 630 S 30000
Quantity: 470 ml / one pint
*Standard S 3 (24-0603) has an additional calibration at -40°C with a guiding value of approx. 70 cSt

Viscometer Bath Thermometers (ASTM - IP)


Precision Made Officially Certified ASTM IP Range
90-0315 90-1315 132C 102C + 148.6...+ 151.4 :0.05 °C
90-0196 90-1196 110C 93C + 133.6...+ 136.4 :0.05 °C
90-0137 90-0254 121C 32C + 98.6...+ 101.4 :0.05 °C
90-0217 90-1217 129C 36C + 91.6...+ 94.4 :0.05 °C
90-0240 90-1240 48C 90C + 80.6...+ 83.4 :0.05 °C
90-0311 90-1311 100C + 78.6...+ 81.4 :0.05 °C
90-0149 90-1149 47C 35C + 58.6...+ 61.4 :0.05 °C
90-0281 90-1281 29C 34C + 52.6...+ 55.4 :0.05 °C
90-0102 90-0251 46C 66C + 48.6...+ 51.4 :0.05 °C
90-0136 90-0253 120C 92C + 38.6...+ 41.4 :0.05 °C
90-0241 90-1241 28C 31C + 36.6...+ 39.4 :0.05 °C
90-0204 90-1204 118C + 28.6...+ 31.4 :0.05 °C
90-0101 90-1101 45C 30C + 23.6...+ 26.4 :0.05 °C
90-0100 90-0250 44C 29C + 18.6...+ 21.4 :0.05 °C
90-0215 90-1215 128C 33C - 1.4...+ 1.4 :0.05 °C
90-0284 90-1284 72C 67C - 19.4...- 16.6 :0.05 °C
90-0214 90-1214 127C 99C - 21.4...- 18.6 :0.05 °C
90-0212 90-1212 126C 71C - 27.4...- 24.6 :0.05 °C
90-0173 90-0252 73C 68C - 41.4...- 38.6 :0.05 °C
90-0285 90-1285 74C 69C - 55.6...- 53.9 :0.05 °C

1
) DKD= Deutscher Kalibrierdienst (German Calibration Service)

C3
Viscosity Petrotest®
Cannon-Fenske Viscometers
ASTM D 445 - ASTM D 446 -ASTM D 2170 - IP 71 - ISO 3104 - ISO 3105
DIN 51 366 - DIN 52 007

Cannon-Fenske Routine Viscometers for Transparent Liquid (CN-type)


Catalog No. Size Viscosity Range
factory certified officially certified ν [cSt or mm²/s]
22-0000 22-2000 25 0.5 - 2
22-0001 22-2001 50 0.8 - 4
22-0002 22-2002 75 1.6 - 8
22-0003 22-2003 100 3 - 15
22-0004 22-2004 150 7 - 35
22-0005 22-2005 200 20 - 100
22-0006 22-2006 300 50 - 250
22-0007 22-2007 350 100 - 500
22-0008 22-2008 400 240 - 1200
22-0009 22-2009 450 500 - 2500
22-0010 22-2010 500 1600 - 8000
22-0011 22-2011 600 4000 - 20000
22-0012 650 10000 - 40000 22-0000. The
22-0013 700 20000 - 80000
viscosity constant will be
22-0020 Viscometer- Set (size 25 thru 600 / 1ea., factory certified) engraved on each
Holder for mounting
22-0097 ... factory certified viscometers
22-2015 ... officially certified viscometers

Cannon-Fenske Reverse Flow Viscometers for Opaque Liquid (CR-type)


Catalog No. Size Viscosity Range
factory certified officially certified ν [cSt or mm²/s]
22-0050 22-2050 25 0.5 - 2
22-0051 22-2051 50 0.8 - 4
22-0052 22-2052 75 1.6 - 8
22-0053 22-2053 100 3 - 15
22-0054 22-2054 150 7 - 35
22-0055 22-2055 200 20 - 100
22-0056 22-2056 300 50 - 250
22-0057 22-2057 350 100 - 500
22-0058 22-2058 400 240 - 1200
22-0059 22-2059 450 500 - 2500
22-0060 22-2060 500 1600 - 8000
22-0061 22-2061 600 4000 - 20000

22-0070 Viscometer- Set (size 25 thru 600 / 1ea., factory certified) 22-0050
Holder for mounting
22-0097 ... factory certified viscometers
22-2065 ... officially certified viscometers

Cannon-Fenske Test Equipment


22-0093 Conical silicone tubing for suction of liquids
23-0204 Suction syringe
10-0013 Water jet pump
Electric vacuum pump (diaphragm pump)
incl. T-connector, Hoffmann-clip and 1 m plastic hose
25-0485 ... for 230 V, 50 Hz
25-0486 ... for 115 V, 60 Hz
22-0164 Stopper for viscometer bath thermometers
22-0163 Protective sleeve for High Precision Thermometers

High Precision Thermometers (DIN 12 771)


Precision Made Officially Certified Range
22-0157 22-0158 + 18...+ 24 :0.01 °C
22-0159 22-0160 + 36...+ 42 :0.01 °C
22-0161 22-0162 + 50...+ 60 :0.01 °C

Viscometer Bath Thermometers acc. to ASTM / IP see page C 3

C4
Petrotest® Viscosity

Ubbelohde Viscometers

ASTM D 445 - ASTM D 446 (D 2515) - IP 71 - ISO 3104 - ISO 3105

Catalog No. for: Size Constant Viscosity Range


manual manual to measure [cSt/s]
measurements, measurements, w. autom. with or [cSt or mm²/s]
works certificate official certificate ViscoClock [mm2/s2]
22-0120 22-1120 22-0320 0 0.001 0.3 - 1
22-0121 22-1121 22-0321 0C 0.003 0.6 - 3
22-0122 22-1122 22-0322 0B 0.005 1 - 5
22-0123 22-1123 22-0323 1 0.01 2 - 10
22-0124 22-1124 22-0324 1C 0.03 6 - 30
22-0125 22-1126 22-0325 2 0.1 20 - 100
22-0126 22-1127 22-0326 2C 0.3 60 - 300
22-0127 22-1129 22-0327 3 1 200 - 1000
22-0128 22-1130 22-0328 3C 3 600 - 3000
22-0129 22-1132 22-0329 4 10 2000 - 10000
22-0130 22-1133 4C 30 6000 - 30000
22-0131 22-1125 1B 0.05 10 - 50
22-0132 22-1128 2B 0.5 100 - 500
220120 22-0133 22-1131 3B 5 1000 - 5000
22-0134 22-1134 4B 30 10000 - 50000
22-0135 22-1135 5 100 20000 -100000

22-0140 Set of Viscometer Capillaries, manual ASTM-type


(1 each of size 0 to 4C, with works certificate)
22-0155 Holder to mount viscometers for manual measurements

22-0340 Set of ViscoClock Capillaries, ASTM-type


(1 each of size 0, 0c, 0b, 1, 1c, 2, 2c, 3, 3c, 4)

DIN 51 362 - DIN 52 007 - ISO 3105

Catalog No. for: Size Constant Viscosity Range


manual manual to measure [cSt/s]
measurements, measurements, w. autom. with or [cSt or mm²/s]
works official certificate ViscoClock [mm2/s2]
certificate
22-0100 22-1100 22-0300 0 0.001 0.35 - 1
22-0101 22-1101 22-0301 0a 0.005 1 - 5
22-0102 22-1102 22-0302 I 0.01 2 - 10
22-0103 22-1103 22-0303 Ia 0.05 10 - 50
22-0104 22-1104 22-0304 II 0.1 20 - 100
22-0105 22-1105 22-0305 IIa 0.5 100 - 500
22-0106 22-1106 22-0306 III 1 200 - 1000
22-0107 22-1107 22-0307 IIIa 5 1000 - 5000
22-0108 22-1108 22-0308 IV 10 2000 - 10000
22-0109 22-1109 IVa 50 10000 - 50000
22-0110 22-1110 22-0310 0c 0.003 0.7 - 3
22-0111 22-1111 22-0311 Ic 0.03 6 - 30
22-0112 22-1112 22-0312 IIc 0.3 60 - 300
22-0113 22-1113 22-0313 IIIc 3 600 - 3000
22-0114 22-1114 IVc 30 6000 - 30000
22-0115 22-1115 V 100 20000 -100000

22-0150 Set of Viscometer Capillaries, manual DIN-type


(1 each of size 0 to IVa, with works certificate)
22-0155 Holder to mount viscometers for manual measurements

22-0350 Set of ViscoClock Capillaries, DIN-type


(1 each of size 0, 0a, I, Ia, II, IIa, III, IIIa, IV)

Viscometer Bath Thermometers acc. to ASTM / IP see page C 3

C5
Viscosity Petrotest®
BS/U-Tube Viscometers
ASTM D 445 - ASTM D 446 - ASTM D 2170 - IP 71 - IP 319
ISO 3104 - ISO 3105 - DIN 52 007 - former DIN 51 372
Catalog No. : Size Constant Viscosity Range
manual for dark fluids [cSt/s]
measurements, with DKD- or [cSt or mm²/s]
works certificate calibration [mm2/s2]
22-0200 22-2200 1 0.003 0.6 - 3
22-0201 22-2201 2 0.01 2 - 10
22-0202 22-2202 3 0.03 6 - 30
22-0203 22-2203 4 0.1 20 - 100
22-0204 22-2204 5 0.3 60 - 300
22-0205 22-2205 6 1 200 - 1000
22-0206 22-2206 7 3 600 - 3000
22-0207 22-2207 8 10 2000 - 10000
22-0208 22-2208 9 30 6000 - 30000
22-0209 22-2209 10 100 20000 - 100000
22-0210 22-2210 11 300 60000 - 300000

22-0220 Set of Viscometer Capillaries, manual U-Tube -type


(1 each of size 1 to 11, with works certificate)
22-0270 Pipette with cork
22-0278 Holder for mounting the viscometers
22-0200
___________________

Engler Specific Viscosity


ASTM D 1665 - IP 212 - (former DIN 51 560)
This method covers the determination of
specific viscosity of various products,
including tar and their fluid products.
It does not determine absolute viscosity
but is an empirical flow test.
21-0009 Standard Engler Viscometer
ASTM D 1665 - IP 212 - (DIN 51 560)
consists of:
test vessel, 200 ml, with a gold-plated inside wall, a double-walled
lid, and a nickel outlet tube. Tall bath vessel, stirrer, wooden valve
spindle, spring type. Volumetric flask, 200 ml, graduated 100 + 100
ml.
Tripod stand, electric heater for connection to 230 V, 50/60 Hz,
complete with power cable and 2 thermometers 0 ... 55: 0.2°C.
25-0001 Electronic energy regulator for 230 V, 50/60 Hz
21-0697 Digital stop watch with LCD indication, battery operated,
quartz controlled.

Engler Thermometers
Precision Officially Thermometer Type Range
Made Certified
21-0109 21-0110 DIN 12785 - BE 0,2/ 0 / 55 0 ... + 55 °C: 0.2°C
21-0111 21-0112 DIN 12785 - BE 0,5/ 0 /105 0 ... + 105 °C: 0.5°C
21-0113 21-0114 ASTM 23C + 18 ... + 28 °C: 0.2°C
21-0115 21-0116 ASTM 24C + 39 ... + 54 °C: 0.2°C
21-0117 21-0118 ASTM 25C + 95 ... + 105 °C: 0.2°C
21-0119 21-0120 DIN 12 735 - BE 1 / 10 / + 10 ... + 200 °C: 1.0°C
200

Spare Parts and Accessories


21-0136 Plug valve, made of hardwood
21-0153 Measuring flask, 100 +100m (DIN-ASTM) 21-0009
21-0155 Measuring flask, 50 ml (ASTM)
21-0156 Kohlrausch flask, 100 ml (ASTM and IP)
21-0157 Kohlrausch flask, 200 ml (ASTM and IP)
21-0307 Spare heater, 230 V, 550 W
25-0001 Electronic energy regulator for 230 V, 50/60 Hz

C6
Petrotest® Viscosity

Redwood Viscometers
(former IP 70)

Redwood viscometers in compliance with temperature of the test.


the former IP 70 standard method are Fuel oils with anomalous behavior
intended for the determination of viscosity (e.g. separation of constituents by
of any petroleum product which flows in a crystallizing) should be tested at
Newtonian manner at the specified temperatures above +120 °F only.

21-0305 Redwood viscometer, Mod. l (former IP 70)


for efflux times up to 2,000 sec.
comprising:
oil cup I, made of brass, internally silver-plated;
agate flow jet, including calibration certificate;
oil cup cover, brass construction;
2 thermometers IP 8C, clip for thermometer support, ball valve;
receiving flask, 50 ml (21-0341), heating bath with stirrer and
electrical heating for 220 V, 50/60 Hz.

21-0325 Redwood viscometer, Mod. II (former IP 70)


for efflux times exceeding 2,000 sec.
comprising:
oil cup II, made of brass, internally silver-plated;
agate flow jet, including calibration certificate;
oil cup cover, brass construction;
2 thermometers IP 8C, clip for thermometer support, ball valve;
receiving flask, 50 ml (21-0341), heating bath with stirrer and
electrical heating for 220 V, 50/60 Hz.

21-0697 Digital stop watch with LCD indication, battery operated,


quartz controlled, 1/100 sec. display

Redwood Thermometers (former IP 70)

Precision Officially Thermometer Type IP Range


Made Certified
21-0361 21-0362 Thermometer 8F + 30 to + 100: 0.5°F
21-0363 21-0364 Thermometer 9F + 100 to + 180: 0.5°F
21-0365 21-0366 Thermometer 10F + 170 to + 250: 0.5°F
21-0367 21-0368 Thermometer 8C + 0 to + 45: 0.2°C
21-0369 21-0370 Thermometer 9C + 40 to + 82: 0.2°C
21-0371 21-0372 Thermometer 10C + 76 to + 122: 0.2°C

Spare Parts
21-0341 Receiving flask, 50 ml
21-0703 Oil strainer with spare gauze
21-0307 Spare heating element, 220 V, 550 W (for Model I)
21-0329 Spare heating element, 220 V, 550 W (for Model II)

C7
Viscosity Petrotest®
Saybolt Viscometers
ASTM D 88 - FTM 791-304 - ASTM E 102
ASTM D 88 - Petroleum products at Universal and Furol viscometers are used for all types of Saybolt viscosity
specified temperatures between 70 and technically identical designs, except for measurements. The efflux time in seconds
210 F. Waxy and resinous materials. orifice tips which differ in diameter. of 60 ml of sample flowing through a
Being built-in as interchangeable units calibrated orifice under specified
ASTM E 102 - Bituminous materials at in the viscometer, the orifice tips, conditions is called the Saybolt Universal
various specified temperatures. Universal or Furol, can be universally or Saybolt Furol viscosity respectively.

Two-tube Saybolt-viscometer
ASTM D 88 - FTM 791-304 - ASTM E 102
consisting of:
stainless steel housing with thermostatically controlled test bath
and electric stirrer.
Temperature range:
+ 20 ... 230 °C (68 ... 450 F)
Temperature accuracy:
± 0.03 °C(± 0,05 °F)
Also including the following accessories:
2 receiving flasks, 60 ml
2 pipettes with rubber suction bulb
2 protective caps
2 thermometer holders
2 cork stoppers
2 viscosity tubes, brass, internally gold-plated with
one each interchangeable Universal and Furol orifice,
including calibration certificate
1 orifice wrench 21-0501
1 tube cleaning plunger (thermometers not included).
21-0501 Mains connection: 230 V, 50/60 Hz
21-0502 Mains connection: 115 V, 50/60 Hz

Saybolt thermometers
Precision Made Officially Certified Range Divisions ASTM N°
21-0601 21-0607 + 19 ... + 27 °C 0.1 °C 17 C
21-0602 21-0608 + 34 ... + 42 °C 0.1 °C 18 C
21-0603 21-0609 + 49 ... + 57 °C 0.1 °C 19 C
21-0604 21-0610 + 57 ... + 65 °C 0.1 °C 20 C
21-0605 21-0611 + 79 ... + 87 °C 0.1 °C 21 C
21-0606 21-0612 + 95 ... + 103 °C 0.1 °C 22 C
21-0621 21-0627 + 66 ... + 80 °F 0.2 °F 17 F
21-0622 21-0628 + 94 ... + 108 °F 0.2 °F 18 F
21-0623 21-0629 + 120 ... + 134 °F 0.2 °F 19 F
21-0624 21-0630 + 134 ... + 148 °F 0.2 °F 20 F
21-0625 21-0631 + 174 ... + 188 °F 0.2 °F 21 F
21-0626 21-0632 + 204 ... + 218 °F 0.2 °F 22 F
21-0641 21-0646 + 245 ... + 265 °F 0.5 °F 77 F *
21-0642 21-0647 + 295 ... + 315 °F 0.5 °F 78 F *
21-0643 21-0648 + 345 ... + 365 °F 0.5 °F 79 F *
21-0644 21-0649 + 395 ... + 415 °F 0.5 °F 80 F *
21-0645 21-0650 + 445 ... + 465 °F 0.5 °F 81 F *
* used for ASTM E 102

21-0600 Thermometer set, comprising one each of:


17C, 18C, 19C, 20C, 21C, 22C
Spare Parts and Accessories
21-0674 Saybolt Viscosity tube, brass, gold plated
with one each interchangeable Universal 21-0705 Orifice spanner wrench
and Furol orifice including calibration 21-0713 Viscosity tube cap, ASTM E 102
certificate 21-0714 Displacement ring, ASTM E 102
21-0693 Receiving flask, 60 ml capacity 21-0697 Stop watch, with LCD indication, battery
21-0699 Oil pipette with rubber suction bulb operated, quarz controlled, 1/100 sec.
21-0700 Oil withdrawal tube display
21-0701 Cleaning plunger 25-0621 Spare heater, 230 V
21-0702 Thermometer holder 25-0641 Spare heater, 115 V
21-0703 Oil strainer no. 100, ASTM E 11
21-0704 Cork stopper with loop For reference liquids see section Q