The RAA50 room thermostat is used in heating systems to maintain the selected room
temperature.
Typical use:
• Residential buildings
• Light industrial buildings
In conjunction with
• zone valves, thermal valves
• gas or oil burners
• fans
• current valves
)XQFWLRQV
+HDWLQJ If the room temperature falls below the select setpoint, the heating contact will close.
6HOHFWRU The front of the unit carries a selector with three positions for Auxiliary Heating /
Heating ON / OFF.
In the OFF position, the input voltage is physically separated from the outputs Q1 and
Q2.
When in the position for auxiliary heating, the contacts to the two outputs Q1 and Q2
are closed.
CE1N3005E
6LHPHQV%XLOGLQJ7HFKQRORJLHV
06.03.2001 /DQGLV 6WDHID'LYLVLRQ
)XQFWLRQGLDJUDPV
4 4
3005D01
3005D02
T Room temperature
Q1 Output signal "Heating"
ON ON Q2 Output signal "Auxiliary
heating"
SD Switching differential
W w Room temperature
OFF OFF
7>&@ 7>&@ setpoint
SD SD
(TXLSPHQWFRPELQDWLRQV
7HFKQLFDOGHVLJQ
$GMXVWPHQWV
The required temperature is selected by a setpoint adjuster on the front of the ther-
mostat.
The setpoint setting range can be mechanically limited by means of setpoint limiter
under the cover.
1RWHV
0RXQWLQJLQVWDOODWLRQ The room thermostat should be located where the air temperature can be sensed as
DQGFRPPLVVLRQLQJ accurately as possible, without getting adversely affected by direct solar radiation or
other heat or refrigeration sources.
Mounting height is about 1.5 m above the floor.
The unit can be fitted to most commercially available recessed conduit boxes or directly
on the wall.
2/4
0HFKDQLFDOGHVLJQ
7HFKQLFDOGDWD
&7LFN conformity to
N474
3/4
'LPHQVLRQV
8QLW
3003M01
99,6
96,4 42,8
%DVHSODWH 86
30 30
30
28
86
28
30
3,6
3001M02