Sunteți pe pagina 1din 188

Standard Method of Measurement of Building Works

Authorised by agreement between the Royal Institution of Chartered Surveyors and the Construction Confederation Seventh Edition Revised 1998

~i
Co-ordinated project information

First Edition, 1922 Second Edition, 1927 Third Edition, 1935 Fourth Edition, 1948 Fifth Edition, 1963; amended 1964; Sixth Edition, 1979 Seventh Edition, 1988 Reprinted 1989 incorporating Amendment Sheets Nos 1 and 2 dated September 1988 and May 1989. Reprinted 1992 incorporating Amendment Sheets Nos 1,2 and 3 dated September 1988, May 1989 and May 1992. Revised and Reprinted 1998 Reprinted 2000 incorporating Amendment Sheets Nos 1 and 2, both dated 2000 Reprinted 2009 incorporating Amendment Sheets Nos 1 and 2, both dated May 2000, and Amendment Sheet No 3 dated June 2009 Copyright

©1998

The Royal Institution of Chartered Surveyors The Construction Confederation

ISBN 0 854063609 (RICS) ISBN 0 852630043 (CC) All rights reserved. No part of this publication covered by the above copyright may be reproduced, stored in a retrieval system or transmitted in any form or by any means without the prior permission of the copyright owners. Designed and set by NBS Services ltd, Newcastle upon Tyne Ae-set and printed by Thanet Press, Margate, Kent.

contents

Summary of

To find the relevant work section for any given topic refer to the detailed contents list overleaf or to the alphabetical index.

Detailed contents
Preface General rules A

Page 1

Preliminaries/General Groundwork In situ concrete/large Masonry

conditions

C
D E F G

Existing site/buildings/services precast concrete

Stru ctu fa IICa rc assing meta IItimbe r Cladding/Covering Waterproofi ng linings/Sheathing/Dry Windows/Doors/Stairs Surface finishes Furniture/Equipment Building fabric sundries partitioning

H J K
l M N P Q

P avi ng/PI anting/Fenc ing/Site furniture


Disposal systems Piped supply systems Mechanical heating/Cooling/Refrigeration Ventilation/Air conditioning systems Electrical supply/power/lighting Comm uni cation Transport systems Mechanical and electrical services measurement systems systems

R
S T

U
V W

s/Secu rity/Control systems

X Y

Additional rules - work to existing buildings Appendices

Alphabetical1index

Page 183

Detailed contents
Preface Preface Preface General to First Edition 1922 to Seventh Edition 1988 to Seventh Edition Revised 1998 Rules 8 9 10 11

D
A
A40

Preliminaries/General conditions
A40 A41 A42 A43 A44 A50 A51 A52 A53 A54 ASS A60 A61 A62 A63 A64 A70 20 20 20 21 21 21

A
AlO All A12 Al3 A20 A30

Preliminaries/Gen eral conditions


Project particulars Tender and contract documents The site/Existing buildings Description of the Works The Contract/Sub-contract Employer's requirements: Tendering/Sub-Ietting/Supply Employer's requirements: Provision, content and use of documents Employer's requirements: Management of the Works Employer's requirements: Quality standards/control Employer's requirements: Sec uritylSafety/Protection Employer's requirements: Specific limitations on method/sequence/timing/use Employer's requirements: Facilities/Temporary works/Services Employer's requirements: Operation/Maintenance of the finished building Al0 All Al2 A13 A20 A30 A31 A32 A33 A34 A35 of site A36 A37 19

17 17 17 17
18 18 18 18 18 18

A31
A32 A33 A34 A35 A36 A37

19

Contractor's general cost items: Management and staff A41 Contractor's general cost items: Site accommodation A42 Contractor's general cost items: Services and facilities A43 Contractor's general cost items: Mechanical plant A44 Contractor's general cost items: Temporary works A50 Works/Products by/on behalf of the Employer AS1 Nominated sub-contractors A52 Nominated suppliers A53 Work by statutory authorities/undertakers A54 Provisional work ASS Oayworks A60 Preliminaries/General conditions for demolition contract A61 Preliminaries/General conditions for investigationlsurvey contract A62 Preliminaries/General conditions for piling/embedded retaining walls contract A63 PreliminarieslGeneral conditions for landscape contract A64 Preliminaries/General conditions for building services contract A70 General specification requirements for work package

22 22 22 22 22

* * * * *

19

B
Bll

Comp lete bu iIdin gs/structures/u nits


Prefabricated buildings/structures building units

E
810
B11

In situ concrete/Large precast concrete


In-situ concrete construction general.ly Mixing/Casting/Curing in situ concrete Sprayed in situ concrete Formwork for in situ concrete Reinforcement for in situ concrete Post tensioned reinforcement for in situ concrete Designed joints in in situ concrete Worked finishes/Cutting to in situ concrete Accessories cast into in situ concrete Precast concrete frame structures Precast/Composite concrete decking E05 EIO Ell E20 E30 E31 E40 E41 E42 E50 E60

810 Prefabricated

* *

cia
Cll C12 C13 C14 C20

Ex.isti ng sitelbu iIdi ngs/services


Site survey Ground investigation Underground services survey Building fabric survey Building services survey Oemolition Non-Hazardous and Hazardous material removal Shoring/Facade retention Cleaning masonry/concrete Repairing/Renovating/Conserving masonry Repairing/Renovating/Conserving concrete Damp proof course renewal/insertion Repairing/Renovating/Conserving metal Aepairing/Renovating/Conserving timber Fungus/Beetle eradication Alterations - spot items

C21
C30 C40 C41 C42 C45 C50 C51 C52 C90

Cl1 C12 C13 C14 C20 C21 C30 C40 C41 C42 C45 C50 C51 C52 C90

cia

* * * * *
23 23 23 25 25 25 27 27 27 27 28

E05 EIO Ell E20 E30 E31 E40 E41 E42 E50 E60

43 43
45 46

49
50 50 51 52

53 54

F
FlO Fl1 F20 F21 F22 F30 F31

Masonry
Brick/Block walling Glass block walling Natural stone rubble walling Natural stone ashlar waiting/dressings Cast stone ashlar walling/dressings Accessories/Sundry items for brick/block/stone Prec ast concrete si IIs/llntels/c opings/features

FlO
Fl1 F20 F21 F22 F30 F31

walling

55 55 58 58 58 62

53

G
011

Structura I/Ca rcassin 9 meta l/timber


Structural aluminium framing Isolated structural metal members CarpentryfTimber framing/First fixing Metal profiled sheet decking Prefabricated timber unit decking Edg.e supported/Reinforced woodwool/rock G10 G11 G12 G20 G30 G31 G32 65 65 65 67 69

D Groundwork

610 Structural steel framing


011 012 020 021 030

012 020 021

D30
040 041 D50

Soil Stabilization Site dewatering Excavating and filling Ground gas venting Piling Embedded retaining walls Crib walls/Gabions/Aeinforced Underpinning

* *
29

*
33 38 40 41

D40
earth 041 050

G11 G12 620 G30 G31 G32

fibre decking

70 70

* No specific rules included - see Genera I rules clause 11.

H
HIO HI1 H12 H13 H14 H2O H21 H30 H31 H32 H33 H40 H41 H42 H43 H50 H51 H52 HoO H61 H62 H63 H64 H65 H66 H70 H71 H72 H73 H74 H75 H76 H90 H91 H92

Cia dd ing/Coveri ng
Patent glazing Curtain walling Plastics glazed vaulting/walling Structural glass assemblies Concrete rootlights/pavement lights Rigid sheet cladding Timber weatherboarding Fibre cement profiled sheet cladding/covering/siding Metal profiled sheet cladding/covering/siding Plastics profiled sheet cladding/covering/siding Bitumen and fibre profiled sheet cladding/covering Glassfibre reinforced cement panel cladding/features Glassfibre reinforced plastics panel cladding/features Precast concrete panel cladding/features Metal panel cladding/features Precast concrete slab cladding/features Natural stone slab cladding/features Cast stone slab cladding/features Plain roof tiling Fibre cement slating Natural slating Reconstructed stone slating/tiling limber shingling Single lap roof tiling Bituminous felt shingling Malleable metal sheet prebonded coverings/cladding lead sheet coverings/flashings Aluminium strip/sheet coverings/flashings Copper strip/sheet coverings/flashings Zinc strip/sheet coverings/flashings Stainless steel strip/sheet coverings/flashings Fibre bitumen thermoplastic sheet coverings/flashings Tensile fabric coverings Thatch roofing Rainscreen cladding

J
HIO Hll H12 HI3 H14 H2O H21 H30 H31 H32 H33 H40 H41 H42 H43 H50 H51 H52 H60 H61 H62 71 72 71 71 73 73 73 75 75 75 75 53 75 53 75
53
77

JIO J20 J21 J22 J30 J31 J32 J33 J40 J41 J42 J43 J44

Waterproofing
Specialist waterproof rendering Mastic asphalt tanking/damp proofing Mastic asph alt roofing/in sulation/finishes Proprietary roof decking with asphalt finish Liquid applied tanking/damp proofing Liquid applied waterproof roof coatings Sprayed vapour control layers In situg lassfi bre reinforc ed piasties Flexible sheet tanking/dampproofing Built up felt roof coverings Single I.ayer polymeric roof coverings Proprietary roof decking with felt finish She et lini ngs for pools/I akes/wate rways

JIO J20 J21 J22 J30 J31 J32 J33 J40 J41 J42 J43 J44

103 83 83 83 83 83
...
_,,_

85 85 85 85 85

K Kll

Lin ings/S heath inglO ry pa rtition in g


Rigid sheet flooring/sheathi ng/de cking/sa rking/linings/casings Under purtin/lnside rail panel linings Rigid sheet fine linings/panelling G!assfibre reinforced gypsum linings/panelling/casings/mouldings Vitreous enamellinings/paneliing Timber boa rd flooring/decking/sa rking/linings/casings Timber stria/board fine flooring/linings Panel partitions Panel cubicles Concrete!Terrazzopartitions Demountable suspended ceilings Raised access floors

H64 H65 H66 H70 H71 H72 H73 H74 H75 H76 H90 H91 H92

H63

79 79 79 79 79 79 79 80 80 80 80 80 80 * * 73
80

77

KIO Plasterboard dry linings/partitions/ceilings

K12 K13 K14 K15 K20 K21 K30 K32 K33 K40 K41

Kl0 Kll KI2 K13 KI4 K15 K20 K21 K30 K32 K33 K40 K41

87 73 73 73 73 73 73 73 90 91
53

92 94

L
110 L20

Windows/Doors/Stairs
WindowsiRooflights/Screens/louvres Doors/Shutters/Hatches Sta irsfWa lkways/Ba lustrades General glazing lead light glazing Infill panels/sheets LIO L20 l30 L40 L41 l42 95

96
97 98 101 102

l30
L40 L41 l42

M Surface finishes
Ml0 Mll M12 M13 M20 M21 M22 M23 M30 M31 M40 M41 M42 MSO MS1 M52 M60 M61 Cement: sand/Concrete screeds/toppings Mastic asphalt flooring/floor underlays Trowelled bitumen!resin/rubber-Iatex flooring Calcium sulfate based screeds Plastered/Rendered/Roughcast coatings Insulation with rendered finish Sprayed monolithic coatings Resin bound mineral coatings Metal mesh lathing/Anchored reinforcement for plastered coatings Fibrous plaster Stone/Cone rete/Quarry/Ceramic tiling/Mosa ic Terrazzo tiling/In situ terrazzo Wood block/Composition block/Parquet flooring Rubber/Pia stics/Cork/Lino/Ca rpet tiling/sheeting Edge fixed carpeting Decorative papers/fabrics Painting/Clear finishing Intumescent coatings for fire protection of steelwerk Ml0 MIl MI2 M13 M20 M21 M22 M23 M30 M31 M40 M41 M42 M50 M51 M52 M60 M61 103 83 103 103 103 106 107 103 108 109 111 113 111 113 113 115 116 116

Nl0 General fixtures/fumishi ngs/eq uipment Nil Domestic kitchen fittings NI2 Catering equipment NI3 Sanitary appliances/fittings NI5 Signs/Notices N16 BirdNermin control N20 N21 } Special purpose fixtureS/lurnishings/equipment N22 N23

Furniture/Equipment
NIO Nil NI2 NI3 NI5 N16 N20 N21 N22 N23 119 119 119 119 119 * * * * *

Building fabric sundries


PIO Pll P20 P21 P22 P30 P31 121 122 123 124 125 126 126

PIO Sundry insulation/proofing work/fire stops Foamed/Fibre/Bead cavity wall insulation Pit items P20 Unframed isolated trims/skirtings/sundry P21 Door/Window ironmongery P22 Sealant joints for buried engineering services P30 Trenches/Pipeways/Pits for services P31 Holes/Chases/Covers/Supports

Q
010 020 021 022 023

Pavi ngIP lanting/FeRC iRg/Site furniture


010 020 131

Kerbs/Ed ging s/Chan nels/Pav; ng accessori es Granular sub-bases to roads/pavings In situ concrete roads/pavings Coated macadam/Asphalt roads/pavings GravelJHoggin/Woodchip roads/pavings 024 Interlocking brick/block roads/pavings 025 Siab/Brick/Block/Sett/Cobble pavings 026 Special surfacings/pavings for sport/general amenity Q30 Seeding/Turfing Q31 External planting 032 Internal planting 035 Landscape maintenance Q40 Fencing Q41 Barriers/Guardrails 050 Site/Street furniture/equipment *No specific rules included - see General rules clause II

021
022 Q23 Q24 Q25 026 030 Q31 Q32 035 Q40 Q41 050

29
132 133 134 135 135 136 137 137 137 * 139 97 119

II

R
RIO Rll R12 Rl3 R14 R20 R21 R30 R31 R32 R33

Disposal systems
Rainwater pipework/gutters Foul drainage above ground Drainage below ground Land drainage Laboratory/Industrial waste drainage Sewage pumping Sewage treatment/sterilisation Centralised vacuum cleaning Refuse chutes Compa ctors/M acerators Incineration plant RIO Rll R12 R13 Rl4 R20 R21 RJO R31 R32 R33 141 141 145 145 y y Y

T
Tl0 Til T12 T13 T14 T15 T16

Mechanical heating/Cooling/ Refrigeration systems


Gas/Oil fired boilers Coal fired boilers Electrode/Direct electric boilers Packaged steam generators Heat pumps Solar collectors Alternative fuel boilers Primary heat distribution Medium temperature hot water heating Low temperature hot water heating Low temperature hot water heating (salt-contained specification) Steam heating Warm air heating Warm air heating (self-contained specification) Local heating units Heat recovery Centrali refrigeration plant Chilled water Local cooling units Cold rooms Ice pads Tl0 Til T12 T13 T14 T15 Tt6 T20 T30 T31 T32 T33 T40 T41 T42 T50 T60 T61 DO Dl y y

y
y

Y
Y

Y Y

no

y y
y Y y

S
S10 S11 Sl2 S13 S14 S15 S20 S21 S30 S31 S32 S33 S34 540 S41 S50 S51 S60 S61 S62 S63 564 S65 S70 S71

Piped supply systems


Cold water Hot water Hot and cold water(self-contained specification) Pressurised water Irrigation Fountains/Water features Tre ated/Deionised/Oistilled water Swimming pool water treatment Compressed air Instrument air Natural gas Liquefied petroleum gas MedicaVLaboratory gas PetroVDiesel storage/distribution Fuel oil storage/distribution Vacuum Steam Fire hose reels Dry risers Wet risers Sprinklers Deluge Fire hydrants Gas fire fighting Foam fire fighting S10 SI1 S12 S13 S14 S15 S20 S21 S30 S31 S32 S33 S34 S4D S41 S50 S51 S60 S61 S62 S63 S64 S65 S70 S71 y

y
y

y
Y

T30 T31 T32 T33 T40 T41 T42 T50 T60 T61

y y y y y

y y y
y y y Y Y Y y Y

DO
TIl T72

T72

y y y

y y
V y

Y y y y
y Y See Y Mechanical and electrical services measurement

U
Ul0 U11 U12 U13 U14 U15 U16 U17 U20 U30 U31 U32 U33 U40 U41 U42 U43 U50 U60 U70

Ventilation/Air conditioning systems


General ventilation Toilet ventilation Kitchen ventilation Car parking ventilation Smoke extract/Smoke control Safety cabinet/Fume cupboard extract Fume extract Anaesthetic gas extract Oust collection Low velocity air conditioning VAV air conditioning Dual-duct air conditioning Multi-zone air conditioning Induction air conditioning Fan-coil air conditioning Terminal re-heat air conditioning Terminal heat pump air conditioning Hybrid system air conditioning Air conditioning units Air curtains Ul0 U11 U12 U13 U14 U15 U16 U17 U20 U30 U31 U32 U33 U40 U41 U42 U43 U50 U60 U70

W Communications/Security/Control
y y y
y WlO W11 W12 W20 W21 W22 W23 W30 W40 W41 W50 W51 W52 W53 W54 W60 Telecommunications Paging/Emergency call Public address/Conference audio facilities Radio/TV/CClV Projection Information/Advertising display Clocks Data transmission Access control Security detection and alarm Fire detection and alarm Earthing and bonding Lightning protection EIectromagneti c sc reeni ng liquid detection alarm Central control/Building management

systems
Wl0 Wl1 W12 W20 W21 W22 W23 W30 W40 W41 WSO W51 W52 W53 W54 W60

y Y Y Y
Y Y Y V Y Y Y Y

y y y y y y Y y y y y
Y V V

Y Y y
Y

Y y

V
Vl0 Vll V12 V20 V21 V22 V30 V31 V32 V40 V41 V42 V50 V51 V90

Electrical supply/power/lighting

systems
Vl0 Vll V12 V20 V21 V22 V30 V31 V32 V40 V41 V42 V50 V51 V90

Electricity generation plant HV supply/distribution/public utility supply LV supply/public utility supply LV distribution General lighting General LV power Extra low voltage supply DC supply Uninterruptable power supply Emergency lighting Street/Area/Flood lighting Studio/Auditorium/Arena lighting Electric underfloor/ceiling heating Local electric heating units Electrical installation (self-contained specification)

y y y Y y y y
Y

Y Y

X10 Xll X12 X13 X14 X20 X21 X22

Transport Systems
Lifts Escalators Moving pavements Powered stairlifts Fire escape chutes/slings Hoists Cranes Trave lIin9 crad les/g antries/la dders Goods distribution/Mechanised warehousing Mechanical document conveying Pneumatic document conveying Automatic document filing and retrieval X10 Xl1 X12 X13 X14 X20 X21 X22 X23 X30 X31 X32 149 149 149 149 149 149 149 149 149 149 149 149

X23
X30 X31 X32

Y Y Y

y y

Y See Y Mechanical

and electrical services measurement

1m

fJ
V
Yl0 Yll Y20 Y21 Y22 Y23 Y24 V25 Y30 Y40 Y41 Y42 Y43 Y44 Y45 Y46 Y50 Y51 Y52 Y53 Y54 Y59 Y60 Y61 V62 Y63 Y70 Y71 Y72 Y73 Y74 Yoo V81 VB2 V89 Y90 Y91 Y92

Mechanical and electrical services measurement


Pipelines Pipeline ancillaries Pumps Water tanks/cisterns Heat exchangers Storage cylinders/Calorifiers Trace heating Cleaning and chemical treatment Air ductlines/ancillaries Air handling units Fans Air filtration Heating/Cooling coils Air treatment Silencers/ Acousti c tre atme nt Grilles/Diffusers/louvres Thermal insulation Testing and commissioning of mechanical services Vibration isolation mountings Control components- mechanical Identification - mechanical Sundry common mechanical items Conduit and cable trunking HV/lV cables and wiring Busbar trunking Support components - cables HV switchgear lV switchgear and distribution boards Contactors and starters luminaires and lamps Accessories for electrical services Earthing and bonding components Testing and commissioning of electrical services Identification - electrical Sundry common electrical items Fixing to building fabric Off-site painting/Anti-corrosion treatments of common mechanical and/or electrical items Motor drives - electric

Additional rules - work to existing buildings


Yl0 Yll Y20 Y21 Y22 Y23 Y24 V25 Y30 Y40 Y41 Y42 Y43 Y44 Y45 Y46 Y50 Y51 Y52 Y53 Y54 Y59 Y60 Y61 Y62 Y63 Y70 V71 Y72 Y73 Y74 Y80 V81 Y82 V89 Y90 Y91 Y92 151 151 154 154 154 154 154 154 156 154 154 154 154 154 154 154 158 159 154 154 159 159 161 163 163 161 166 166 166 167 167 163 169 169 169 * 116 166
Work Groups H, J, K, Land M Rl O-R13 Drainage Mechanical Services Electrical Services

171 173 173


175

Appendices
A B Fixtures, furnishings, equipment, fittings and appliances Classification of mechanical and electrical services

177

181

Alphabetical index

183

"No specific rules included - see General rules clause

11

Preface to First Edition 1922


For many years the Surveyors' Institution and the Quantity Surveyors' Association (which bodies are now amalgamated) were accepted as the recognised authorities for deciding disputed points in connection wifh the measurement of building works. The frequency of the demands upon their services for this purpose directed attention to the diversity of practice, varying with local custom, and even the idiosyncracies of individual surveyors, which obtained. This lack of uniformity afforded a just ground of complaint on the part of contractors that the estimator was frequently left in doubt as to the true meaning of items in the bills of quantities which he was called upon to price, a circumstance which militated against scientific and accurate tendering. In the absence of any statutory qualifications for surveyors practising in the United Kingdom, any person, up to the present, has been at liberty to describe himself as a quantity surveyor, and the public have no guarantee that he is qualified for that office. This fact resulted in the issue of a considerable amount of unskilled work under the designation of bills of quantities. Both the Surveyors' Institution and the Quantity Surveyors' Association were impressed with the necessity of securing greater accuracy of work and uniformity of method. The latter body, in July 1909, with this object in view appointed a Committee who prepared and published pamphlets setting out the method of measurement recommended by the Association in respect of three trades. The Surveyors' Institution also issued to its members circulars giving an authoritative opinion as to the correct method of measurement in the case of items in connection with which disputes had occurred. The desirability of co-operation between the two societies thus became evident, and a Joint Committee was set up in June 1'912, upon which was imposed the task of drawing up a comprehensive set of Standard Rules of Measurement of Building Works. In 1918 representatives of the building trades were added to this Committee, four contractors being nominated by the National Federation of Building Trades Employers and the Institute of Builders. The Joint Committee were assisted in their deliberations by interviews with the representatives of certain trades. The Standard Method of Measurement of Building Works drawn up and' set forth in the following pages is founded upon the practice of the leading London quantity surveyors with certain modifications by way of alternatives, and not involving matters of princpte, to suit the practice obtaining in other parts of the Kingdom. The Joint Committee was composed as follows: six surveyors nominated by the Surveyors' Institution and the Quantity Surveyors' Association, and four contractors nominated by the National Federation of Building Trades Employers and the Institute of Builders, viz Surveyors: Messrs. F.A ..H Hardcastle (Chairman), Thomas E. Bare (Hon.Sec.), R.C. Gleed, Arnold E. Harris, Walter Lawrence, and Morgan H. Young. Contractors: Messrs. R. Friend (Rugby) (Vice-Chairman), W. Lacey (London), Stanley Miller (Newcastle-on-Tyne) and Frank Woods (Bolton, Lancashire). Other gentlemen who have served on the Committee for a time are: Surveyors: Messrs. Arthur G. Cross, WE Davis, J.E. Drower, and Henry Riley ..Contractor: Mr. Walter lawrence (London).

Preface to Seventh Edition 1988


The Joint Working Party on Measurement Conventions set up by The Royal Institution of Chartered Surveyors and the then National Federation of Building Trades Employers reported in December 1971. Out of this report a Development Unit was set up and quickly came to the conclusion that far reaching changes were required. As an interim measure the Sixth Edition of the Standard Method of Measurement was published in March 1979. Now, with the publication of this Seventh Edition, the work envisaged by that working party has been completed. The Co-ordinaling Committee for Project Information has produced a Common Arrangement of Work Sections for Building Works. In support of the principles of CCPI and in accordance with the wishes of the sponsoring bodies, this Edition has been structured in common arrangement order rather than in traditional work sections. This means that the Standard Method of Measurement is now compatible with other CCPI publications and with aU standard documentation where these criteria have been adopted. The other major change from previous editions is that the measurement rules have been translated from prose into classification tables. This change makes the use of the rules a quicker and more systematic task than interpretation of a prose version and readily lends itself 10 the use of standard phraseology and computerisation. The change however does not inhibit the use of traditional prose in the writing of bills of quantities if so desired. In addition to these two major changes, the rules have generally been simplified and the document brought up 10 date to equate wih modern practice. The Committee expresses its thanks to the professional and trade associations for their co-operation and advice in the detailed consultations that have taken place and to the surveyors and builders who have assisted in testing the new rules, to Geoffrey E. Beard who chaired the Committee from June 1975 to September 1984 and especially to the editors who have had the task of bringing together all the various drafts and presenting them in a uniform manner in a relatively short space of time. This Seventh Edition will become operative on 1 July 1988 and is post dated accord ingly. The Join! Committee responsible for this edition at the date of issue was composed as follows: Appointed by the Royal Institution of Chartered Surveyors: Christopher J. Willis (Chairman), Ronald C. Allan, Keith W. Bailey, John Bennett, Eric J. Bowman, N. Malcolm S. Boyd, Michael A. Rainbird, Eric H. Urquhart and Michael J.T. Webb. Appointed by the Building Employers Confederation: Andrew J. Costelloe (Vice-Chairman), John M. Allen, Bernard Ball, Kenneth G. Ellis, James E. Fisher, Colin M. Ford, Richard J. Hooker, Robert H. Inglis, Terence J. Parkinson and Donald J. Rimmer. Co-opted from the Development Unit: Tony AIIott, Stuart Hendy, Peter Holden, Peter G. Jordan and Rex H. Sharman. Consultant Members of the Committee: Geoffrey Joint Honorary Secretaries: Norman Smith (Queries).

E.

E. Beard and Ian M.C. Hill.

R. Wheatley (General) and Michael B.

Others who have served on the Committee or the Development Unit during the preparation of this edition: Dr Martin Barnes, Robert A. Barrow, Ian T. Brown, Peter Graham, Alan M. Harrison, Patrick Kelly, Anthony R. Miller and Paul D. Morrell. Consultant Editors appointed by the Committee: Paul J. Gilkes and Richard E.N. McGill CJW: 1 October 1987

Preface to the Seventh Edition Revised


The Seventh Edition of the Standard Method of Measurement was published in 1988. Following experience in use and in consequence of queries raised minor amendments were made in September 1988, May 1989 and in May 1992. Now in 1998 further changes are required. The Seventh Edition when published was in a completely new format using as a base the Common Arrangement of Work Sections for Building Works as part of an initiative for Co-ordinated Project Information in the industry. In 1997 a further advancement in this initiative was made with the publication by the Construction Project Information Committee, the successors to the authors of the original CAWS, of a new manual entitled UN/CLASS. UN/CLASS is a document intended to be used for a wide number of different purposes including organising documents in libraries, project and cost information, specifications etc. Many potential users of UN/CLASS are currently users of CAWS in one form or other. UN/CLASS includes certain amendments to the original CAWS and as CAWS is the base document for SMM 7 it has been necessary to recognise these changes and to amend SMM 7. The changes are mainly to titling, phraseology and order and in consequence, whilst the changes incorporated in this revision are extensive, the changes to the rules themselves are minimal. As well as making the changes consequent upon the amended CAWS the Standing Joint Committee have taken the opportunity to correct certain other anomalies that have arisen since the third amendment was published in 1992. This Revised Seventh Edition will become operative on 31st July and is postdated accordingly.

1998

The Joint Committee responsible for this Amended Edition at the date of issue was composed as follows: Appointed by the Royal Institution of Chartered Surveyors: Ronald CAllan (Chairman), Keith W. Bailey, Andrew O'Kelly, Michael A Rainbird, and Michael B.Smith. Appointed by the Construction Confederation: Donald J Rimmer (Vice Chairman), Kevin M.Callan, Brian W.Gordon, and Richard J

. Hooker.

Consultant members of the committee Andrew J.Costelioe and Christopher J Willis Joint Honorary Secretaries: Norman R. Wheatley (General) and John D.O'N.Davidson (Queries). RCA: 1 July

1998

III

General rules
1. Introduction
2.5
The left hand column of the classification table lists descriptive features commonly encountered in building works. The next column lists further sub-groups into which each main group of items shall be divided and similarly the third column provides for further division. The lists in these columns are not intended to be exhaustive.

1.1 This Standard Method of Measurement provides a uniform basis for measuring building works and embodies the essentials of good practice. Bills of quantities shall fully describe and accurately represent the quantity and quality of the works to be carried out. More detailed information than is required by these rules shall be given where necessary in order to define the precise nature and extent of the required work.

2.6
Each item descri ption shall identify the wo rk with respect to one descri ptive feature drawn from each of the first three columns in the classification table and as many of the descriptive features in the fourth column as are applicable to the item. The general principle does not apply to Preliminaries in that it will be necessary to select as many descriptive features as appropriate from each column.

1.2
The rules apply to measurement of proposed work and executed work.

2.
2.1

Use of the tabulated rules

Generally
The rules in this document are set out in tables. Each section of the rules comprises information (to be) provided, classification tables and supplementary rules. The tabulated rutes are written in the present tense.

2.7
Where the abbreviation (or) is given in the classification shall be stated in the item description. table the quantity

Supplementary rules 2.8


Within the supplementary rules everything above the horizontal line. which is immediately below the classification table heading, is applicable throughout that table. 2.9 Measurement rules set out when work shall be measured and the method by which quantities shall be computed. 2.10 Definition rules deline the extent and limits of the work represented by a word or expression used in the rules and in a bill of quantities prepared in accordance with the rules.

2.2
Horizontal lines divide the classification zones to which different rules apply. table and supplementary rules into

Classification tables
2.3 Within the classification table where a broken line is shown, the rules given above and below the broken line may be used as alternatives.

2.4
In referring to columns in classification umn has been disregarded. tables the measurement unit col-

2.11 Coverage rules draw attention to particular incidental work which shall be deemed to be included in the appropriate items in a bill of quantities to the extent that such work is included in the tender documents. Where the coverage rules include materials they shall be mentioned in the item descriptions. 2.12 The column headed Supplementary Information contains rules governing the information which shall be given in addition to the information given as a result of the application of rule 2.6. 2.13 A separate item shall be given for any work which differs from other work with respect to any matter listed as supplementary information.

4.

Descriptions

4.1 Dimensions shall be stated in descriptions generally in the sequence length, width, height. Where ambiguity could arise, the dimensions shall be identified.

4.2
Information required by the application of rules 2.6 and 2.12 may be given in documents (e.g. drawings or specification) separate from the bills of quantities if a precise and unique cross reference is given in its place in the description ot the item concerned. This rufe does not allow the aggregation of a number of measured items which are otherwise required to be measured separately by these rules, except as provided by rule 9.1.

4.3
Headings to groups of items in a bill of quantities shall be read as part of the descriptions of the items to which the headings apply.

3.
3.1

Quantities

4.4 The use of a hyphen between two dimensions in this document or in a bill of quantities shall mean a range of dimensions exceeding the first dimension stated but not exceeding the second.

Work shall be measured net as fixed in position except where otherwise stated in a measurement rule applicable to the work. 3.2 Dimensions used in calculating quantities shall be taken to the nearest 10mm (i.e. 5mm and over shall be regarded as 10mm and less than 5mm shall be disregarded).

4.5
Each work section of a bill of quantities shall begin with a description stating the nature and location of the work unless evident from the drawn or other information required to be provided by these rules.

4.6
Unless otherwise specifically stated in a bill of quantities following shall be deemed to be included with all items: (a) Labour and all costs in connection (c) Assembling, therewith. therewith. (b) Materials, goods and all costs in connnection (d) Plant and all costs in connection therewith. (e) Waste of materials and all costs in connection with dispasal. (f) Square cutting. (g) Establishment charges, overhead charges and profit. or herein, the

3.3

Quantities measured in lonnes shall be given to two places of decimals. Other quantities shall be given to the nearest whole unit except that any quantity less than one unit shall be given as one unit.

3.4
Unless otherwise stated, where minimum deductions for voids are dealt with in this document they shall refer only to openings or wants which are within the boundaries of measured areas. Openings or wants which are at the boundaries of measured areas shall always be the subject of deduction irrespective of size.

fitting and fixing materials and goods in position.

4.7
A dimensioned description for an item in the bill of quantities shall define the item and state all the dimensions necessary to identify the shape and size of the item or its components.

3.5
The requirement to measure separate items for widths not exceeding stated limit shall not apply where these widths are caused by voids. a

IS

5.

Drawn information

5.1 Location drawings: (a) Block Plan: shall identify the site and locate the outlines of the building works in relation to a town plan or other context. (b) Site Plan: shall locate the position of the building works in relation to setting out paints, means of access and general layout of the site. (c) Plans, Sections and Elevations: shall show the position occupied by the various spaces in a building and the general construction and location of the principal elements.

(d) Work carried out in or under water shall be so described stating whether canal, river or sea water and (where applicable) the mean Spring levels of high and low water. (e) Work carried out in compressed air shall be so described pressure and the method of entry and exit. stating the

8.

Fixing, base and background

5.2 Component drawings: shall show the information facture and assembly of a component.

8.1 Method of fixing shall only be measured and described where required by the rules in each Work Section. Where fixing through vulnerable materials is required to be identified, such materials are deemed to include those listed in rule 8.3 (e).

necessary

for manu-

8.2
Where the nature of the base is required to be identified each type of base shall be identified separately.

5.3
Dimensioned diagrams: shalt show the shape and dimensions of the work covered by an item and may be used in a bill of quantities in place of a dimensioned description, but not in place of an item otherwise required to be measured.

8.3
Where the nature of the background is required to be identified description shall state one of the following: the item

5.4
Schedules which provide the required information drawings as required under these rules. shall be deemed to be

(a) Timber, which shall be deemed to include manufactured building boards. (b) Masonry, which shall be deemed to include concrete, brick, block and stone. (c) Metal. (d) Metal faced materials. (e) Vulnerable materials, which shall be deemed to include glass, marble, mosaic, tiled finishes and the like.

6.

Catalogued or standard components

6.1 A precise and unique cross-reference to a catalogue or to a standard specification may be given in an item description instead of the description required by rules 2.6 and 2.12 or instead of a component drawing.

7.

Work of special types


special types shall be separately identified:

9.

Composite items

7.1 Work of each of the following

(a) Work on or in existing building - see general rule 13. (b) Work to be carried out and subsequently orary works). (c) Work outside the curtilage of the site. removed (other than temp-

9.1 Notwithstanding the requirement of clause 4.2, work to be manufactured off site may be combined into one item even though the rules require items to be measured separately, provided the items in question are all incorporated into the composite item off site. The item description shalt identify the resulting composite item and the item shall be deemed to include breaking down for transport and installation and subsequent reoasse mbly.

10. Procedure where the drawn and specification inf·ormation required by these rules is not available
10.1 Where work can be described and given in items in accordance with these rules but the quantity of work required cannot be accurately determined, an estimate of the quantity shall be given and identified as an approximate quantity. 10.2 Where work cannot be described and given in items in accordance with these ru les it shall be given as a Provi sional Su m and identified as for either defined or undefined work as appropriate. 10.3 A Provisional Sum for defined work is a sum provided for work which is not completely designed but for which the following information shall be provided: (a) The nature and construction of the work. (b) A statement of how and where the work is fixed to the building and what other work is to be fixed thereto. (c) A quantity work .. or quantities wh,ich indicate the scope and extent ot the and the like identified in Section A35.

11. Work not covered


11.1
Au les of measu rement adopted for work not covered by these ru les shall be stated in a bill of quantities. Such rules shall, as far as possible. conform with those given in this document for similar work.

12. Symbols and abbreviations


12.1 The following symbols measure ment: m m2 and abbreviations are used in this method of

= =
:;

metre square metre cubic metre millimetre number kilogramme

rn3
mm

or
kg I h pcsum provsum

= = = = =
:;

tonne hour Prime Cost Sum Provisional exceeding equal to or exceeding not exceeding less than percentage Sum

(d) Any specific limitations

10.4 Where Provisional Sums are given for defined work the Contractor will be deemed to have made due allowance in programming, planning and pricing Preliminaries. Any such allowance will only be subject to adjustment in those circumstances where a variation in respect of other work measured in detail in accordance with the rules would give rise to adjustment. 10.5 A Provisional Sum for undefined work is a sum provided for work where the information required in accordance with rule 10.3 cannot be given. 10.6 Where Provisional Sums are given for undefined work the Contractor will be deemed not to have made any allowance in programming, planning and priCing Preliminaries.

> >
< < %

=
::::

- hyphen (see rule 4.4)

12.2
Cross references within the classification Work Section number Example: Number from first column Number from second column tables are given in the form: Number from third column Number from fourth column

14. General definitions


14.1 Where the rules require work to be described as curved with the radii stated details shall be given of the curved work including if concave or convex, if conical or spherical, if to more than one radius and shalf state the radius or radii. 14.2 The radius stated shall be the mean radius measured to the centre line of the material unless otherwise stated.

020: 2. 2. 2. 1
Excavation and filling Excavating To reduce levels Maximum depth < 1.00m Commencing level stated ground level.

where

> O.25m below existing

12.3 An asterisk within a cross reference represents all entries in the column in which it appears.

12.4
The digit 0 within a cross reference represents which it appears. no entries in the column in

13. Work to existing buildings


13.1 Work to existing buildings shalt be so described. Such work is defined as work on, or in, or immediately under work existing before the current project.

13.2
The additional rules for work to existing buildings are to be read in conjunction with the preceding rules in the appropriate Work Sections. 13.3 A description of the additional Preliminaries/General conditions which are pertinent to the work to the existing building shall be given, drawing attention to any specific requirements due to the nature of the work.

A Preliminaries/General conditlons
INFORMATION PROVIDED
Pl Location drawings as defined ill General Rule 5.1

II
SUPPLEMENTARY INFORMATION

MEASUREMENT RULES

DEFINITION RULES
01 A fixed charge is for work th e cost of which is to be conside red as independent of duration 02 A ti me related charge is tor work the cost of which is to be considered as dependent on du ra~on

COVERAGE RULES
C 1 Works of a temporary nature are dee med to include rates, lees and charges related thereto in Sections A36, A41 , A42, and A44

P2 Information to facilitate visiting site and addresses where drawillgs or other information additional to that required by Ihese rules or other listed information may be inspecled

CLASSIFICATION TABLE

Al0 Project particulars


t Project particulars 1 Name, nature and locafion 2 Names and addresses of Employer and Consultants item

Al1 Tender and contract documents


1 O(ll;UmllnlS 1 list 01 drawings/other documents 1 Used lor bitl of quantities item

Z To be used for contract

A12 The site/Existing buildings


1 The siteJExi sling build ings 1 Site boundaries 2 Existing buildi ngs on or adjacent to the site 3 Existi ng mai nslsefllices 4 Others, details stated item

, A13 Descriplion of the Works


1 Description of the work

1 Elements of each new


buifding 2 Dimensions and shape retating to each building 1 Plan area and perimeter at each floor level 2 Heights betwee n floors

item

3 Total heig ht
3 Detaits of related work by others

Mt Given onry when the equiv al ent information is not indicated on the drawings provided

A20 The Contract/Sub-contract


1 Form of Contract 1 Schedule of clause headings ot standard conditions 2 Specia I conditions or amendments to standard conditions 3 Appendix insertions 4 Employer's insurance responsibility 5 Performance guarantee bond/collateral warranties item 1 Under deed

A30 Employer's requirements: Tendering/Sub-letling/Supply


1 Employer's requirements or limitations 1 Details stated 1 Fixed charge 2 Time related charge item

A3l Employer's requirements: Provision, content and use of documents


1 Employer's requirements or limitations
1 0 etai I5 stated

1 Fixed charge 2 Time related charge

item

A32 Employer's requirements: Management of the Works


1 Employer's requirements or lim italions 1 Details stated 1 Fixed charge 2 Time related charge item

A33 Employer's requirements: Quality standards/control


1 Employer's requirements or limitations 1 Details stated 1 Fixed ch arge 2 Time related charge item

A34 Employer's requirements: Security/Safety/Protection


1 Employer's requirements or limitations, details Slated t Noise and pollution control 2 Maintain adjoining buildings 3 Maintain public and private roads 4 Maintai n live services 5 Security 6 Protection of work in all 1 Fixed ch arge 2 Time related charge item

sectons

7 Others

Preliminaries/General

conditions continued MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION

CLASSiFICATION TABLE

A35 Employer's requirements: Specific limitations on method/sequence/timing/use of site


1 Employe~s requirements or limitations, delails stated 1 Oesign constraints 2 Method and sequence of work 3 Access 4 Use of the sne 5 Use or dlsposal of materials found 6 Start of work 7 Worki ng hou rs 8 Others 1 Fixed charge 2 Time related charge ilem

A36 Employer's requirements: facilities/Temporary works/Services


1 Employe(s requirements or limitations, details slated 1 Offices 2 Sanitary accommodalion 3 Temporary fences, hoardings, screens and roofs 4 Name boards 5 Technical and surveying equipment 6 Temperature and humidity 7 TelephonefFacsimile installation and rental/maintenance 6 Others 9 Telephone/Facsimile charges call prov sum 1 Fixed charge 2 Time related charge item C2 Heating, lighting, cleaning and maintenance are deemed to be included

A37 Employer's requirements: Operation/Maintenance of the finished building


1 Employer's requirements or limrtations 1 0 etai Is stated 't Fixed charge 2 lime related charge item

A40 Contractor's general cost items: Management and staft


1 Management
and stall

1 Fixed cha.rge
2 nme related charge

item

and stall Includes management, trades supervision, engineering, programming and production, quantity surveying support staff and the like

03 Management

A41 Contractor's general cost Items: Site accommodation


1 Srte accornmodaton 1 Fixed charge
2 nme related charge item 1 Made available by the Employer, details and conditions stated

D4 Site accommodation inCludes offices, laboratories. ca~ns, stores, compounds, canteens, sanitary fadfities and the ijke

A42 Contractor's general cost Items: Services and facilities


1 Services and facilities
1 Power 2 lighting J fuels 4 Water 5 Telephone aM administrat ion 6 Safety, health and wetfare 7 Storage of materials 8 Rubbish disposal 9 Cleaning 10 Drying out 11 Protection of work in all sections 12 Security 13 Mainta in public and private road s 14 Small plant and tools 15 Others 16 General attendance on nominated sub-contractors I 7 General attendance of nominated sub-contractors in respect of the requirements of tile Joint Fire Gode 1 Fixed charge 2 Time related charge item 1 Made available by the Employer, details and conditions stated

05 Ilems listed are not e)(haustive and are for convenience of pricing only

C3 General attendance is deemed to inClulla the use of the COlllracto(s temporary roads. pavings and paths, standing scaffold ing. 3tanding power operated hoisting plant the provision of temporary lighting and water supplies. clearing away rubbish. provision 01 space for the sub-contractor's own offices end the storage of his plant and materials and the use of messrooms. sanitary atcommodation and welfare facilities provided by the Contractor C4 General attendance. where the Joint Fire Code applies is detmed to in~lude hand bells, whistles. klaxons, manualiV operated sounders, security guards, fire· signage 18.g. location of fire access routes and positions of dry riser inlets end fire e~ting~jshersl. fire doors and fire stopping to lift-shafts. service ducts and voids. water supplies for fire fighting equipment and the services at an appropriate number of Fire Marshalls where the works are a ~rge project

A Preliminaries/General conditions continued


CLASSIFICATION TABLE A43 Contractor's general cost Items: Mechanical plant
1 Mechanical plant 1 Cranes 2 Hoists 3 Person nel transport 4 Transport 5 Earthmoving plant 6 Concrete plant 7 Piling plant 8 Paving and surfacing plant 9 Others 1 Fixed charge 2 Time related charge item 1 Made available by the Employer, details and conditions stated D6 Items listed are not exhaustive and are lor convenience 01 prici ng on Iy

fD
MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION

A44 Contractor's general costilems: Temporary works


1 Temporary works 1 Temporary roads 2 Temporary walkways 3 Access scaffolding 4 Support scaffolding and propping 5 Hoardings, fans. tencing 1 Fixed charge 2 TIme related charge item 1 Made available by the Employer, details and conditions staled

07 Items listed are not exhaustive and are tor convenience 01 pricing only

etc,

6 H ardstanding 7 T raffie regulations 8 Others

A50 Work/Products by/on behalf of the Employer


1 WorkiMaterials Employer by the 1 Worn by others directly employed by the Employer, details stated 2 Attendance on others directly employed by the Employer, details stated 3 Materials provided by or on behalf of the Employer, deta,ils stated item

AS1 Nominated sub-contractors


1 Nominated sub-contractors 1 Sub-contractors wolll 1 Description stated in accordance with General Rule 10.3 pc sum M2 General attendance on sub-contractor's wolll is measured in Section A42

2 Main contractors protrt 3 Main cDnlractDr's overheads 4 Special attendance, details stated 1 Scaffolding 2 Accessroads 3 Hardstandings 4 Positioning 5 Storage 6 Power 7 Temperature and humidity 8 Others

% % ilem 1 Fixed charge 2 Time related charge 08 Scaffolding under this rule is special scaffolding, scaffolding additional 10 the Contractor's standing scaffolding, or standing scaffolding required to be a~ered or retained D9 Positioning includes unloading, distributing, hoisting and placing in position giving in the case of significant Hems the weight and/or size and position relative to ground level or other datum Fixing only such items is deemed to include unloading, storing, hoisting the goods and materials and returning packaging materials to the nominated supplier carriage paid and obtaining credits therelor Dl0 Work by statutory authorities includes work by publk: companies responsfble lor statutory work when executi ng their statutory duty

A52 Nominated suppliers


1 Nominated suppliers 1 Supplie~s materials 1 Description stated pc sum % M3 Fixing only such items is measured in the appropriate Work Section

C5

2 Main contractor's proli!

51 Particulars of any costs to be paid of conveying goods and materials to the site and/or of any special packing or similar requirements

A53 Work

by statutory authorities/undertakers
1 Work by the local authority 2 Work by statutory urnlertakers prov sum

1 Work by statutory authorities

A54 Provisional work


1 Provisional work 1 Defined 2 Undelined prov sum 011 For deli ned and undefined provisional sums see General Rule 10

ASS Dayworks
1 Oaywollls 1 LabOur 2 Ma.tefials 3 Plant prov sum

C Existing site/buildings/services
C20 Demolition
C21 Non-Hazardous and Hazardous material removal

C30 Shoring/facade retention


INFORMATION PROVIDED
PI The following intorma~on is shown either on locanon drawings under A Preliminaries./General which accompany the bills of quantities: (a) the location and eldent of existing struclures to be demolished conditions or on further drawings

MEASUREMENT RULES
Ml The rules within this Section apply to works to existing buildings as defined in the General Rules

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION

CLASSIFICATION TABLE
1 Demolishing all slructures 1 Description sufficient for identification 1 Levels to which structures are demolished item 1 Materials remaining the property of the Employer 2 Materials for re-use 3 Making good structures 4 Leaving parts 01 existing walls temporarily in position to act as buttresses 5 Temporarily diverting, maintaining or sealing off exisling services 6 Non-hazardous material 7 Hazardous material 4 Support 01 structures not to be demolished 5 Support of roads a nd tire like 1 Position and type of shoring and nature of slruciure or road to be shored stated item 1 Providing and erecti ng 2 Maintaining. stated duration M2 Only temporarily diverting, maintaining or sealing off existing services is measured under this rule Dl Materials arising from demolitions are the property of the Contractor unless otherwise stated Cl Demolition items are deemed to include: (a) disposal 01 materials other than those remaining the property 01 the Employer or those for re-use (b) temporary support incidental to demolitions which is at the discretion 01 the Contractor SI Method of demolition where by specific means S2 Setting aside and storing materials remaining the property of the Employer or those lor re-use S3 Employer's restrictions on methods of disposal of materials

2 Demolishi n9 indivklual structures 3 Demolishing structures parts of

02 [Jeffi{ll ishing parts of


structures excludes items covered bV Section COO All material is deemed to be inert unless otherwise described

03

04 Support is ather than temporary support incidental to demolitions

C2 Support is deemed to include nails, wedges and bolts

3 Adapting, details stated 4 Clearing away 5 Cutting holes in the structure. details stated

6 Making good all work


disturbed

6 Temporary roofs
7 Temporary screens

1 Dim ensioned description

item

1 Providing and erecting 2 Maintaining, stated duration

54 Detaits of weather and dust proofing requirements

3 Adapti ng, detaiLs stated 4 Clearing away 5 Dispos ing of ra inwater ,


details slated

6 P rovidi ng open ings,


dsta iIs stated

C40 Cleaning masonry/concrete


C41 C42 Repairing/Renovating/Conserving Repairing/Renovating/Conserving masonry concrete
MEASUREMENT RULES
1.11 The rules within this Section apply 10 works to existing buildings as defined in the General Rules

INFORMATION PROVIDED
PI The following informa1ion is shown either on location drawings under A Preliminaries/General conditions or on further drawings which accompany the bills of quantities: (a) the scope and location of the work relative 10 the exi~ting layout indicating the existing structure

DEFINITION RULES
01 Materi als arising are the property of the Contractor unless otherwise stated 02 locations stated relative to the existing building

COVERAGE RULES
Cl Shoring and scaffolding incidenlal to the work and making good atl work disturt>ed by such shoring and scaffolding is deemed to be included C2 Wolllto existing buildi ngs ~ems are deemed to include: (a) disposal 01 materials other than those remaining the property of the Employer or those for re -use (b) incidenta.1 wolll which is at the discretion of the Contractor (c) atl new fixing or joining materials required

SUPPLEMENTARY INFORMATION
SI Melhod of operation, where by specific means S2 Setting aside and storing materials remaining the property of the Employer or those for re- use 53 Employers restrictions on methods of disposal of materials

54 Restrictions on the method of shoring and scaffolding

CLASSIFICATION TABLE
1 Cuning out defective concrete and replacing with new 1 0 imen sioned description 1 Plain, delails stated 2 Reinforced, details stated 3 Gun applied, details staled m1 m 1 T reatment 01 reinforcement, details staled 2 Anchored mesh reinforcement, details staled 1 Centres of drilling holes 2 Removing existing finishes

---

C3 Formwork and making good to match existing are deemed to be included

S5 Method of bonding new to existing

nr

2 Resin or cement impregnationlinjection

1 Dimensioned

description

1 Concrete _details stated 2 Brickwork, details staled

ml
--

3 Blockwork, details staled


4 Stonework, deta.ils stated 3 Cutting out decayed, defective or cracked work and replacing with new 1 Size and depth or Ihid<ness slated 1 Brickwork, details stated 2 Blockwolll, 3 Stonework, details stated details stated

nr

--

C4 Work is deemed to include making good holes and Iinishes on completion

m1
--

nr 4 Repainting 1 Size and depth 01 raking out of existing joint 1 Brickwork, details stated 2 Siockwork, details stated

--

1 Making good with materials other than to match existing, details stated

C5 WolII is deemed to include making good to match e)(lsting

S6 Method of bonding new to existing

m2
- --

1 Type of painting

m
- --

M2 Details stated include bond and size 01 companent

3 Stonework, delails staled

C6 Repainting is deemed to include making good to adjoining work

S7 Composition mortar

and mix of

nr

CLASSIFICATION TABLE
5 Removing stains and the like (or) 1 > 1.00 m2 2
:0:;

MEASUREMENT RULES
I Concrete

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION
Special cleaning rnaierials

m2
t--

1 Facings 2 Etnorescence 3 Stains 4 GraHitti 5 Vegelation 6 Algae 7 Others, details stated

1.00 ffi2

2 Brickwork 3 Blockwork
4 Stonework

nr

M3 Number of areas is only stated in the description when measured in m2

sa

6 Cleaning surfaces

t Concrete 2 Brickwork 3 Blockwork 4 Stonework

1 Facings

m2

1 Washing 2 Abrasive blasting 3 Chemical treatments 4 Others, details stated

S9 Cleaning materials

7 Inserti ng new wall ties

1 Size and type of He

1 Brickwork 2 Block.work 3 Stonework

nr

t Surface finishes, details stated

M4 Inserting new wall ties is measured here only when executed without demolition

S10 Details of cutting away and making good

8 Re1Jressing to new profile

1 Detailed description and size of new profi Ie 2 Detailed description and length and size 01 new p!'ofile

M5 Work is measured linear where 01 a connmous nature

r-nr

9 Artificial weathering

1 Concrete 2 Brickwork 3 Btockwork 4 Stonework

m'

1 To match existing

C45

Damp proof course renewal/insertion


MEASUREMENT RULES DEFINITION RULES COVERAGE RULES
Cl Works are deemed to include: (a) disposal of materials (b) making good to holes and finishes after injection

INFORMATION PROVIDED
PI The following information is shown either on location drawings under A Preliminaries/General
conditions or on further drawings which accompany the bills 01 quantities: (a) 1he scope and location of the work relative 10 the existing layout indicating the existing structure

SUPPLEMENTARY INFORMATION
51 Me1hod of operation, where by specific means S2 Damp proof chemicals

CLASSIFICATION TABLE
1 Chemical damp proof courses 2 Injection mortar damp proof courses 3 Inserted mecllanical damp JlIoof courses 1 Brickwork 2 Btockwork 1 Thickness of wall stated m 1 Centres 01 drilling holes 2 Removing existing finishes

3 Stonework

COO Repairing/RenovatinglConserving
C51
INFORMATION PROVIDED

Repairing/Renovating/Conserving C52 Fungus/Beetl e e rad icati on

metal timber
MEASUREMENT RULES
conditions or on further drawings

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION

PI The following information is shown either on location drawings under A Preliminaries/General


which accompany the bills 01 quantities: (a) the scope and locanon of the work

CLASSIFICATION TABLE
1 Repairing metal 2 Repairing limber 1 Dimensioned description m'
--

MI The dimensioned
description or dimensioned diagram (in conjunction with the Information Provided) must clearly idenfity all work in exploration, preparaton and execution together wilh Ihe associated works required

01 Repairing includes renovation. conservation refurbishment

or

3 Treating existing timber

nr

--

SI SUCh inlormation as is appropriate to the repair. renovation or refurbishment of Iheitam S2 Such informatioo as ~ appropriate to the trealment 01 umber to eradicate fungus attacks or beetle infestation

ego

Alterations· spot items


PROVIDED MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION SI Method 01 operation, where by specific means S2 Setting aside and storing materials remaining the property of the Employer or those for re-use

INFORMATION

Pl The following information is shown either on locabon drawings under A PreliminariesJGeneral conditions or on lurther drawings which accompany the bills of quantities: (a) the scope and location of the work relative to the existing layout indicating the existing structure

Ml The ru les within this Seelion apply to works to existing buildings as defined in the General Rules M2 Any operaton to existing buildings involving removal of existing materials (other Ihan for bonding purposes or renewal) is measured within this Section

Dl Materials arising from alterations - spot items are the property 01 the Contractor unless otherwise slated D2 Location is stated relative to existing build iog

Cl Shoring and scaHoh:ling incidental to the work and making good all wolll disturbed by such shoring and scaffolding is deemed to be included within each ite m C2 Alterations' spot items are deemed to include: (a) disposal of materials other than those remaining the property of the Employer or those lor re-use (b) work incidentallo a~erations - spot items which is at the discretion at the Contractor (e) all new fixing or joining materials required

53 Employefs restrictions on methods 01 disposal of materials


S4 Employefs restrictions on methods of shoring and scaffolding 10 be used

CLASSIFICATION

TABLE

1 Removing fittings and fixtures 2 Removing plumbing and engineering installations 3 Removing finishings 4 Removing coverings 5 Cutting openings or recesses 6 Cul1ing back projections 7 Cutting to reduce thickness 8 Filling in openings 9 Temporary roofs

1 Delails sufficient for identificaton stated 2 Dimensioned description sufficient tor idenmication including type and thickness of existing structure

item

1 Making good structures 2 Extending and making good fi nishings 3 Inserti ng new work, details stated 4 Non-hazardous material

M3 Details stated for inserting new work are the equivalent of those details required by lhe rules for the measurement 01 the same in other wolll sections

D3 Inserting new work includes re·fixing or re-using removed materials D4 All male rial is deemed to be inert unless otherwise described

5 Hazardous material

1 Dimen sioned description

item

1 Providing and erecting 2 Maintaining, duralion slaled 3 Adapting. details stated 4 Clearing away 5 Disposing 01 rainwater, details staled 6 Providing openings, detai Is stated

~0 Temporary screens ,

S5 Details of weather and dust proofing requirements

D Groundwork
020 Q20

Exca.vating and filling Granular sub-bases to roads/pavings


MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION

INFORMATION PROVIDED
PI The following information is shown either onocancn drawings under A Preliminaries/General conditens or on further drawings whiCh accompany the bills 01quantities or slated as assumed: (a) the ground water level and the date when it was established, defined as the pre-contract water level (b) the ground water level is to be r·e~established at the time each excavation is carried out and is defined as the post contract water level (c) ground water levels subject to periodic changes due to tidal. or similar effects are so descdbed giving the mean high and low water levels (d) details 01 trial pits or boreholes including their location and the SOil Investigation Report together with the chemical a nalyses there of tro m which the inert, 11oil-hazard 0 usa 11d hazard 0 us mate ri a I elas s ilications ca n be deterrn i ned (e) features retained

(I) live over or underground services indicating location (g) pile sizes and layout in accordance with Sections D30 - D32 where applicable

CLASSIFICATION TABLE
1 Site prepara~on
1 Removing tfees

1 Girth 6oo'mm - 1.50 m 2 Girth 1.50 - 3.00 m


3 Girth> 3.00 slated

III

2 Removing lree stumps

m. girth

MI Tree girths are measured at a height 01 1.00 m above grou nd M2 Stump girths are measured at the top

C 1 This worlds deemed to include: (a) grubbing up roots {b) disposal 01 materials (c) tilling voids Dl Site vegetation is bushes, scrub, undergrowth, hedges and trees and tree stumps s 600 mm girth

51 Filling male rial described

3 Clearing site vegetafion

4 Description sufficient lor idenblication slated

m2

4 Ulling turf lor preservation

1 Method 01 preservi ng. details stated

ml

2 Excavating

1 Topsail for preservaton 2 To reduce levels

1 Average deplh siated 1 Maximum depth s 025 m 2 Maximum depth s 1.00 m

ml m1

I Commencing level stated where> 0.25 m below existi ng ground level

3 Basements and the like


4 Pits ("r) 5 Trenches, width s 0.30 m 6 Trenches, width> 0.30 m 7 For pile caps and ground beams between piles

3 Maximum depth s 2.00 m


4 and therealter in 2.00 m stages

M3 The quantities given are Ihe bulk before excavating and no allowanoe is made for subsequent varia~on s 10 bulk or for extra space for working space or to accommodate earthwork support M4 Excavaling for grou nd beams not between piles is measured under 2.5 s 6.*.*

D2 All male rial is deemed to be inert un les s ot herw ise described D3 Not used

e
3 Items ext ra over excavating in inert material irres pectlvs 01 dept n

To bench sloping grou nd to receive filling m1 1 Excavating below ground water level

1 ExcavaUng belOw ground


water level 2 Non-hazardous material

M5 If the post contract


waler level diHers from the pre·contractwater level the measurements are revised accordingly M6 To be measured where precautions are specifically required 04 Retaining a service is a precaution sper;ificolly required 82 Natu[e of special requirement
I

3 Hazardous male rial 4 Next existing seNiCes 5 Around existing services crossing excavation 4 Breaki ng out existing materials 5 Breaki ng out existing hard pavings, thickness stated

t Type 01 se rvice slated

-rn

t Rock 2 Concrete

mJ
I-ml

1 Extra over any types of excavating irrespective of deplh

Reinforced concrete

05 Rock is any material which is 01 such sire or ~sition that it can only be removed by wedges. special plant or explosives

4 Blickwork, blockwork or stonework

5 Coated macadam or
asphalt 6 Working space allowance 10 excavatons 1 Reduce levels, basements and the like 2 P~s 3 Trenches 4 Pile caps and ground beams between pi les ml M7 Working space is measured where the face of the exca vaton is < 600 mm from the face of tormwork., re ndering, tanking or protective walls Me The area measured is calculated by mu Iliplying t~e girth at the tormwork, rendering, tanking or protective walls by the depth of excavation below the commenci ng level 01 the excavaton

06 Backfilling with special materials occurs where selected or trested excavated materials or im~ned materials are used

C2 Additio nal earthwork support, disposal, back!i Iling, work below ground water level and breaking out are deemed to be included

83 Details of backfilling with sped al materials

020 Q20 continued


CLASSIFICATION TABLE
7 Earthwork support 1 Maximum depth::; 100 m 2 Maximum depth stages 1 Distance between opposing taces s 2,00 m 2 Distance between opposing faces 2,004.00m ml

Ell
MEASUREMENT RULES
1 Curved
2 Below ground water level 3 Unstable grou nd 4 Next to roadways M9 Earthwork support is measured the lull depth to all faces 01 excavation whether or not required except to (a) tace s 0,25 m high (b) sloping faces of excavations where the angle of inclination is ::; 45° from the horizontal (c) faces of excavations which abut existi ng walls, piers, or other structures Ml0 Earthwork support below ground water level or in unstable ground is measured from the commencing level of the excavation to the full depth M1t Earthwork support below ground water level is only measured where a corresponding Item is measured in accordance with 3. t .0.0 a fld is adjusted accordingly if the post contract water level is diHerent

DEFINITION RULES
07 Earthwork support is deemed to mean providing everything to uphold the sides of excavation by means other than interlocking steel piling which is measured in Section 030 08 Earthwork support next to madways occurs wnere the horizontal distance from the face supported to the edge of the roadway or footpath is < the depth of the excavated face below the bottom of the foundations 09 Earthwork support next to existing buildings occurs wnere the horizontal distance from the lace suppo rted to the nearest part of the foundations of tm. bui Iding, is < the depth of the excavated face oolow the bottom of the foundations 010 Unstable ground is running silt. running sand, loose gravel and the like

COVERAGE RULES
C3 Curved eartt,work supporJ is deemed to include any extra costs of curved

SUPPLEMENTARY INFORMATION

s 2,00

3 and thereafter in 2,00 m

excavaton

3 Distance between
opposing faces> 4,00 m

5 Next to existing buildings 6 left in

8 Disposal

1 Surface water 2 Ground water

ilem

M12 An ilem for disposal of ground water is onty measured where a corresponding item is measured in accordance with 3,1, and is adjusted accordingly if the post contract water level is different 1 Specified locations, detal Is staiec 2 Specified handling, details staled 3 Non-hazardous material M13 The Quantity given for disposal is the bulk before excav ali ng and no allowa nee is made for subsequent variations to bulk or for extra space to accommodate eanhwork support

011 Surface water is wa ter 0 n the surface of site and the excavations

3 Excavated material

1 Olfsite

m3

2 On sile

C4 Any type of excavated or broken out material is deemed to be Included

4 Hazarcous material

~
9 Filii ng to excavations 10 Filling

to make

up levels

1 Average thic~ness s 0.25m 2 Average thickness > O.25m

' I Arisi ngiro m the excavations 2 Obtained from on site spoil heaps 3 Obtained off site, type stated

m'

1 Selected, details sta ted

2: Treated, details stated


3 Topsoil 4 Specified handling, details stated

MI4 Fitting is measured as equal to the void fill·ed MI5 The average Illi ckness measured for fiffing is that afte r com paction MI6 The positon 01 external planters and the like is only stated where not at grou nd level

It Filling to external planters and the like, position stated

C5 Filling arising from Ihe excavations is deemed to include multiple Ilandling at me contractors discretion

S4 Ki nd and quality 01 malerials 55 Method of filling and compacfing in tayers

12 Su rtace paoong to fill ing

1 To vertical or battered laces

ml

o 12 Work is only deseribed as


battered where the slope > 15° from hOIizontal MI7 Surlace treatments may al ternatively be give n in the description of any superticial item t Blinding, material stated M1S Specific blinding beds are measu red as IiIiing 10.*.*.* MI9 Concrete blinding beds are measu red in Section E 10 I In rock M20 Trimming sloping surlaces is 0 nly measu red where the stope is > 15° from horizontal C6 Compacting Es deemed 10 include li!velli ng and grading to lalls and slopes s 150 from hori zontsl

13 Su nace treatments
I

I Applying herbicides

I-m'

S6 Kind and cu ality of materials and rate of application

2 Compacting

1 Ground 2 Filling

S7

Melhod of C{)mpacting

3 Bottoms of excavations

S8 Kind and quality 01 malerials

3 Trimming

I Siopi ng su rrace s

2 Sides of culli ngs

1 Battered
2 Vertical 3 In rock

3 Sides of embankments

4 Trim mi ng roc~ to produce


I air 0 r exposed lace 5 Preparing subsoil for top soil

59 Method 01 preparing

030

Piling
MEASUREMENT RULES
conditions or on further drawings

III
DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMA liON

INFORMATION PROVIDED
PI The following information IS shown either on location drawings under A Preliminaries/General which accompany the bills of quantities (a) the genera.1piling layout (b) the positions of different types of piles (e) the positions of the work within the site and 01 existing services (d) the relabonship to adjacent buildings

P2 Soil description: (a) the nature of the ground is given in accordance with Section 020 Information Provided (b) where work is carried oul near canals. rivers. etc. or tidal waters, the level of the ground in relation to the normal levels of the canal or river etc. or to the mean Spring levels of high and low tidal waters. is stated; flood levels are stated where app"cable P3 Commenong levels: (a) the levels from which the work is expeCted to begin and from which measurements have been taken are Slated; irregular ground is so described

CLASSIFICATION TABLE CAST IN PLACE CONCRETE PILING


1 Bored piles 2 Driven shell piles

1 Nominal diameter stated

3 ~--------------r-~ Secant piles 4 Raking. inclination


2 Total concreted length length. length m stated

1 Total number. commencing surface stated

nr

1 Preliminary piles 2 Contiguous bored piles ratio

3 Total bored

or driven maximum stated

m
m

3 Pre-boring driven piles

1 Maximum ~pth stated

M1 Bored and driven lengths are measured along the axes of the piles from the commencing surface to the bottom of the shafts of bored pi les and to the bottom of the casings of driven piles I------------i M2 Pre-boring is only measured where it is specifically reQuired

01 Piles comprising a driven light gauge casing which is first Ii lied with concrete and then withdrawn are classed as driven shell pi les where the piles are designed for the load to be carried OIl the co ncrete 02 Filling such piles is not
classed as filling hollow piles in accordance with Section

CIT otal concrete length is deemed to include concrete placed in excess of the completed length C2 Pre-boring is deemed to include grouting up voids between sides of piles and bores

S 1 Kind and quality of


materials and mix details

S2 Tests of materials

S3

Type of grout

S4 Details 01 compaction

030.20.1··

4 Backfilling empty bores

1 Type of backfill material staled 1 Breaking through obstructions

Items extra over piling

M3 Breaking through obstructions is only measured where obstructions are encountered above the founding stratum of the pile C3 The work is deemed to include work below the specified bottom

2 Enlarging bases for bored piles 3 Enlarging bases lor driven shell piles

1 Diameter of enla.rged
base stated

nr

6 Permanent casings

1 Internal diameter stated

1 Length ~ 13 m (m) 2 Length:> 13 m (nr)

1 Wall thickness of caSing stated

1.15 Permanent casings are measured from the commencing surlace

C4 Permanent casi ngs are deemed to include driving heads and shoes

S5 Type of material and finish to external surface S6 Details 01 driving heads and shoes where not at the discretion of the Contractor

7 CUttillll off tops of piles (m)

1 Nominal diameter stated

1 Totallenglh

1 Tops of permanent
casings

C5 Cutting off tops of piles

is deemed Ie include
preparabon and integration of reinforcement into pile cap or grou nd beam and disposal

8 Reinforcement to piles

1 Nominal size 01 bars


stated 2 Nominal size 01 helical bars stated

1 Nominal diameter of piles


stated 1 Off site 2 Onsite mJ 1 Specified locations, details stated 2 Specified handling, details M6 The volume of disposal 01 surplus excavated materials is calculated from the nominal cross-sectional size of piles and their lengths measured in accordance wilh 1 & 2.1.2. The volume of enlarged bases is added 1.0this calculation

C6 Aeir.lorcement to piles is deemed to include tying wire, spacers, links and binders which are at the discretion of the Contractor

S7 Kind and quality 01 malerials

9 Disposal

1 Excavated materials

to be inert unless otherwise described

03 All material is deemed

sialed
3 Non-hazardOUS material 4 Hazardous material

10 Delays

1 Rig standing

M7 Delays are only measured where specifically authorised

C7 Delays are deemed to include associated labour

f----

11 Pile tests

1 DetailS stated

or

sa

Timing and details of

tests

030

continued
MEASUREMENT
1 Total number driven. speci fied length and com mencing su rf ace stated 2 Total driven depth nr t Preliminary piles 2 Raking. inclin alio n staled

CLASSIFICATION TABLE PREFORMED CONCRETE PILING


12 Reinforced piles 13 Prestressed piles 14 Reinforced sheet piles 15 Hollow section piles 16 Reinforced segmental piles 1 Nominal cross-seclional size staled

RULES

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION
S9 Kind end quality of materials S10 Tests of materials Sl1 Details of driving heads and shoes

M8 The measurement for the total driven depth includes for driving e)(lended piles M9 The driven depth is measured from the commencing surface to the bottom of the pile toe along the axis of the pile

04 The total driven depth is C8 Driving. heads and that specifically required by shoes ere deemed to be the designer included

17 Items extra over piling

1 Redriving piles

nr

M10 Reddving piles is only measured where it is specifically required MIl Pre-boring is only measured where it is specifically required

1B Pre-boring

1 Maximum depth stated

C9 Pre-boring is deemed to include grouting up voids between sides of piles end bores

SI2 Type of grout

19 Jetting 20 Filling hollow piles with concrete 1 Plain m m nr m CIO Preparing heads, to receive pile extensions is deemed to be included S13 Specification 01 concrete end reinforcement

21 Pile extensions

",

Reinforced, details stated Total number

2 Extension length::; 3.00 m 3 Extension length> 3.00 m


22 Cutting off tops of piles
(nr)

1 Total length

C11 Cutting off tops of piles is deemed to include prepration and integration of reinforcement into pile ca p or ground beam and disposal M12 The volume of disposal 0.1 surplus excavated materials is calculated from the nominal cross-sectional size of piles and their depths measured in accordance with 12-16.1.1 and 2." 05 All material is deemed to be inert unless otherwise described

23 Disposal

1 Excavated material

1 Off site

ml

2 On site

1 Special locations. details stated 2 Specified handling. details stated 3 Non -nazaro 0us mate riaI 4 Hazardous material

24 Detays

1 Rig standing

M13 Delays are only measured where they are specificallyauthorisad

CI2 Delays are duell1ed to inctude associated labour

r--25 Pile Ie SIS 1 Delails stated nr S14 Timing and details of

tests

CLASSIFICATION TABLE STEEL PILING


26 Isolated piles 1 Mass per metre and cross-sectional size, or section reference stated 1 Total number driven specified length and comme ncing s urfa c e stated 2 Total driven depth nr , PreIimina ry pites 2 Raking, inclination ratio stated m 3 To be extracted

MEASUREMENT RULES
M14 The measurement of the total driven depths includes for driving extend ed pile s MI5 The driven depth is measured from the c ommen c inII surfa ce to the bottom of the pile toe along the axis of the pile MI6 The following separate items are required for each group of interlocking piles: (a) one or more items for the tota I area of th B group of piles divided into the ranges of specified lengths given in 27.1.1-3.~ (b) an item for the total driven area of the group of piles M17 The areas of items fo r inteno ckin 9 piles are calculated by multiplying the mean undeveloped horizontal lengths of the pile walls formed (including lengths occupied by special piles) by the depth s measured in accordance with the definllons of driven depths in the case of items for the driven areas and by the lengths measured in accordance with the definition of lengths in the case of items for the specified areas of piles

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION
S15 Kind and quality of materials S16 Tests of materials

06 The specified length is that specifically required by the designer

e13 The cost of extra ction is deemed to be included with piles so described

'l7 Interlocking piles

I Section modulus and cross-sectional size, or section reference stated

I Total area of specified length'" 14.00 m 2 Total area of specified laflgth 14.00- 24.00 m 3 Total area of specified len gth > 24.00 m 4 Total driven area

m'

ED
D30 continued CLASSIFICATION TABLE
28 Items extra over interlocking piles I Comers 2 Junctions 3 Closures 4 Tapers 29 Isolated pile extensions 1 Mass per metre and cross-sectional size, or section reference stated 2 Seetion moduIIIs and cross-ss ctio naI size. or section referen c B stated 1 Mass per metre and eross-seenonat SIze, or sE!ction reference stated 2 Section modulus and cross-sectional size, or section reference stated 32 Cutting interlocking piles to form holes 33 Delays 1 Dimensioned description 1 Ri9 sta nding 1 lsnlated piles 2 Inte rloc king pil es 34 Pile tests 1 Details stated nr 1 Total number 2 Extension length s 3,OQm 3 Extension length> 3.00m nr m I Preliminary piles 2 Raking, inclination ratio state d 3 To be extracted 4 Using materials arising from ctltting off 511 fill us len 9ths 01 other piles 1 Isolated piles (nr] m , Preliminary piles 2 Raking, inclination ratio stated 2 Interlocking piles (nr) m M20 The length measured is the surplus length of each pile MI9 Separate items are required for the length of pile extensions and for the number of pile extensions C14 The cost of extraction is deemed to be inel uded with piles so described CI5 Pile extensions are deemed to include tile work necessary to attach the extension to tile pile I Type stated m

MEASUREMENT RULES
MIS The length measured for items extra over is the totallen9til

DEFINITION

RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION

30 Interlocking pile extensions

31 Cutting off surplus from specified lengths

CI6 Cutting off surplus from specified lengths of piles is deemed to include provision and filling of working space and disposal

nr

M21 Delays are only measured where specifically authorised

CI7 Delays are deemed to include associated labour S17 Timing and details of tests

040 Embeddedretaining walls


INFORMATION PROVIDED
PI The 1011 owing information is shown either on locaticn drawings under A Preliminaries/Genaral conditions which ace om ~any the bills 01 qua ntiti as: Ie) tha arrangement olambeddad retaining walls and their relationship to surrounding buildings (b) tha depths,leng!hs and thicknusu of embedded reUJining walls
Of

MEASUREMENT RULES
on further drawings M 1 Piled walls are measured in accordance with Section

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION

030

P2 Soil description: (a) the nature ollhe groond is given in accordance with Section D20 Inlormation Provided (b) where work is carried out near canals, rivers, etc. or tidal waters, the level of the ground in relation to the normal level of tlle canal or river etc. or 10 the mean Spring levels of high alloj low tidal waters is stated: flood levels are stated where applicable P3 Commencing levels: (a) the levels from which the work is expected to begin and from which msasuremerns (b) irregular 9found is so described have been taken are stated

CLASSIFICATION TABLE DIAPHRAGM WALLING


1 Exca~a~on and disposa I 1 Th ickness of wall stated 1 Maximum depth stated mJ M2 The volume oj axe aveticn and disposal is calculated using the nominal I len g!hs and depth s of th e wa IIs. Th e da pths afa ta ken from the commencing surface SI Details of support fluid S2um itlltio ns on method of disposal
,

2 Items extra over excavating in inert material and disposi ng the reot

1 Non-Ml(Ifdous

material

m)

2 Hazardous mate riaI

Dl All material is deemed to be inert unless otherwise described

3 Breaking out existing


materials

1 Rock 2 Concrete 3 Reinforced concrete 4 Brickwork. blockwcrk 0 r stonework 5 Coated macadem or asphalt M3 Concrete volume is measured net except that deductions are not made far the following: la) reinforcement Ib) steel sections of areas s ld) voids .. 0.05 m'in volume
Ie) cast in accessories

4 Breaking out existing hard pavings, thickness stated 3 Ba ckf IIing empty fre neh 4 Concrete 1 Type of IiII rnate rial stated 1 Thickness of wall staled

-m' mo
-

53 Materials and mix


detailS S4 Tests

0.50 m'

m1

040 continued CLASSIFICATION TABLE


5 Reinforcement

MEASUREMENT RULES
M4 Reinforcement is measured in accordance with Section E30 and the mass measured includes that of stiffening, lifting and supporting steel cast in where specifically required
I---

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION

6 Cutting off to specified level

1 Thickness of wall stated

Cl Cutting oft to specified level is deemed to inc Iude provision and filling of working space and disposal

7 Trimming and cleaning face of diaphragm walling 8 Waterproofed joints

1 Oetails stated

I-

OJ'

1 Type and method stated

M5 Waterproofed joints are only measured where they are specifically required M6 The lengths measured for guide walls are those of the diaphragm walls M7 The extent to which excavation. disposal. support, concrete, reinforcement, formwork, and the like are to be includ ed is stated in th II item description C2 Preparing cast in pockets or chases is deamed to include fe moving formwork and preparing cast in reinforcement

9 Guidewalls

lOne side 2 Both sides

I limitations on design
and construction stated

10 Ancillary work in connection with diaptlragm walling

t-1 Prepa ring cast in pockets or chases at [unctiens, details stated item

2 Excavating temporary backfill J Removal of guide walls lOne side 2 Both sides 11 Oelays I Rig standing

Im' MB The Iengths mea sured fo r guide wa Us are those of the diaphragm walts M9 DelaVs are onlv measured where they are specifically authorised

C3 Removal of guide walls is deemed to include disposal C4 Delays are deemed to include associated labour

SS Limitations on method of disposal

12 Tests

1 Details staled

I----nr

S6 liming and details of tests

041

Crib walls/Gabions/Reinforced earth


PROVIDED
Of

INFORMATION

MEASUREMENT RULES
on further

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION

PI The following information is shown either on location drawings under A Preliminaries/General conditions drawings which accompany the bills of quantities: {a) The relative position of crib walls, gabions and earth reinforcement

CLASSIFICATION TABLE
I Crib walls I Thic kness stated 1 Flat undeveloped area m' 1 Vertical 2 Battering 3 Curved on plan Ml No deductions are made for openings within crib walls which are part of the modular system, nor for openings", 1.oom' Cl Crib walls are deemed to include dowels and pins, granular infill and compaction, special units, forming ends and comers, obtaining and providing manufacturer's certificates and for building in pipes and forming small openings C2 Gabion baskets are deemed to include assemblng, tying and fixing and bracing and tying lids 1 Selected, details started 2 Treated, details started 3 Specified handling, details started 4 Earth reinforcement 1 Fabric 1 Mesh refe rence m' 1 Flat 2 Sloping 3 Curved on plan M4 No deductions are made lor voids", I,oom' in area M3 The area measured for earth reinforcement excludes laps. C4 Earth reinforcement is deemed to include assembling, tying, fixing, stacking and tensioning S2 Minimum laps M2 filling is measured Ih e nett vol urnII of the basket C3 filling is deemed to include compaction and overfilling

SI Kind and quality materials

2 Gabion baskets

1 Dimensioned description

Nr.

3 Filling to !labion baskets (Nrl

m'

050

Underpinning
MEASUREMENT RULES
conditions or on further drawings

II
DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION

INFORMATION PROVIDED
PI The following information is shown either on location drawings under A Preliminaries/General which accompany the bills of quandlies (a) the location and extent of the work (b) details of the existing structure to be underpinned

P2 Information regarding the nature of excavation work is described in accordance with Section 020 Information Provided
P3 The limit of length carried out in one operation and the number of secaons the Contractor is permitted to undertake at one time

CLASSIFICATION TABLE
1 T empor ary support lor
existing stnuctures I Particu lar requirements staled I Preliminary trenches 1 Maximum depth -:; 0.25 m 2 Maximum depth s 100 m item SI DetaHs ot making good

2 Excavating

ml

I Curved 2 From one side only

2 Underpinning pits

3 Maximum depth

s 2.00

3 From both sides

4 and the realter in 2.00 m stages

Ml Wid1h allowances are relaled to the total depth of excavation measured from the top or the preliminary trench to the base of the underpinning pit as follows: (a) 1 m where the total depth is ~ f ,5 m (b) 1.5 m where the total depth is 1.5 ~ 3m (c) 2 m where Ihe total depth is > 3 m
M2 The width of a preliminary trench is calculated as the sum 01 any projection of Ihe retained foundation beyond the face of the wall plus any projection of th e underpinning beyond the face of the retained foundation plus the width allowance M3 The width at an u nderpinn ing pit is calculated as the sum of the width of retained toundation plus any projection of the underpinning beY0rld the face of the retained foundation plus the width allowance

01 Preliminary trenches
extend down to the underside of existing foundations

02 Underpi nning pits extend from Ihe underside of existing foundations down to the base of the underpinning excavation

3 Items extra over any type of excava~ng irrespective 01 depth

M4 Items extra over are measured in accordance with Section D20:3~5. '*.

*. *

I-4 Earthwork support

1 Preliminary trenches
2 underpinning pits

m1

M5 Earthwork support is measured in accordance with Section 020:7.*.*.* M6 Earthwork support to underpinning pits is measu red to the back. front and both ends of the underpinning pits and also between each section of Itle underpinning

5 Culli ng away existing Pfojecting foundations

1 Masonry 2 Concrete 1 Width 01 existing work stated

1 Maximum wid1h and depth of Pfojection stated

6 Preparing the underside


01 the existing work to receive the pinni ng up 01 the new work 7 Disposal

M7 Disposal of water and excavated material are measured in accordance with Section 020:8.*.*.* M8 Filling is measured in accordance with Section 0209 & 10-*-*.* M9 Surface treatments are measured in accordance with Section 020:13.*.'-1<-. * M 10 Concrete, lormwork, reinforcement, brickwork and tanking are measu red in accordance with the appropriate Work Sections

8 Filling

9 Surface treatments

10 Concrete 11 Formwork 12 Reinforcement 13 Brickwon.; 14 Tanking

IS

E In situ concrete/Large precast concrete


E05 In situ concrete construction generally E10 Mixing/Casting/Curing in situ concrete
INFORMATION PROVIDED
P1 The following information is shown either on location drawings under A Preliminaries/General which accompany the bills of quantities; (a) Itle relative posijions of concrete members (b) Itle size of members (c) the thickness of slabs {dj the permissible loads in relation 10 casting limes conditions or on further drawings

MEASUREMENT RULES
M1 Concrete volume is measured net except that deductions are not made lor the following: (a) reinforcement (b) steel sections of area S 0,50 m2 (c) cast iII accessories (d) voids S 0,05 mJ in volume (except voids in troughed and coffered slabs)

DEFINITION RULES

COVERAGE RULES
C 1. Concrete is deemed to include finishing as struck from basic finish formwork Of with a non- mechanical tamped lin ish unless otherwise required under worked finishes

SUPPLEMENTARY INFORMATION
51 Kind and quaUty 01 materials and mix details 52 T esls of malerials and finished work Measures watertightness

sa

to achieve

54 Umijations on method, sequence, speed or size 01 pouring


55 Methods of compaction and curing 01 Foundations include attached column bases and attached pile caps 02 Isolated loundations include isolated column bases, isolated pile caps and machi ne bases

CLASSIFICATiON TABLE
1 Foundations 2 Ground beams

m3

1 Reinforced
2 Reinforced> 3 Sloping S 15° 5%

3 Isolated fou ndations


4 Beds 1 Thickness

M2 The Itlickness range stated in descriptions excludes projections and

56 Requirement fOf beds to be laid in bays

recesses
M3 The th ickness range stated 01 collered and trough ed slabs is measu red overall

s 150 mm

4 Sloping> 15° 5 Pou red on 0 r against


earth or unblinded hardcore

Slabs slabs

2 Thickness 150 - 450 m m

6 Coffered and troughed


7 Walls 8 Filling hollow walls 9 Beams 10 Beam casings

3 Thickness > 450 mm

03 Beds inc1ude:
(a) blinding beds (b) plinths (c) thidlenings 01 beds

1 Isolated 2 Isolated deep 3 Attached deep

1 Reinforced 2 Reinforced>

5%

04 Slabs include: (a) allached beams and beam casings whose depth is s three times their width (depth measured below Itle slab) (b) column drop heads
05 Collered and troughed slabs incfude margins whose width is S 500mm_ Wider margins are included with ordinary slabs 06 IWal1s include attached columns and piers

11 Columns 12 Colu mn casings

f---m1

13 Staircases

M4 Columns iIre only measured as such when isolated and when their lenglh on plan is s lour ~mes their thickn ess

07 Deep beams and beam casings are those whose depth (measured below the slab where anach ad) is ~ three times 1M eif width DB Staircases inelude landi ngs and strings

14 Upstands

09 Upslands exclude kickers

15 Ilems extra ovs r the in


situ co ncrale in which Iheyoccur 1 Wo rki ng around heati ng panels 2 Monolithic Iirashes, th ickness slated

m'
1 Top surlace sloping,,; 15° 2 Top surtaee sloping ~ 15°

M5 The area measured is the system area

010 Monolithic Iinishes


include Ih ose which are cast onto concrete by lining lormwork

16 Grouting

1 Stanchion bases 2 Grillages

nr
f---------;

17 Filling

1 Mortices
2 Holes, (nr)
I

nr I-m' I-m) I-m


"

3 Chases ~ 0.01 m2
4 Chases
$;

o.oi

m2

ED

E11 Sprayed in situ concrete


INFORMATION PROVIDED
PI The following information is shown either on location drawings under A Preliminaries/General drawings which accompany the bills of quantities: lat ths relative positions 01 sprayed concrete members (b] the permissible loads in relation to casting times conditions or on further

MEASUREMENT RULES

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION

CLASSIFICATION TABLE
1 Slabs 1 Thickness staled 1 Tops 2 Soffits 2 Walls 3 Beams 4 Columns m' 1 Curved Ml Reinforcement is measured in Section E30 51 Kind and quality of materials 52 Preparato ry work

S3 Method 01 application and finish

E20

Formwork for in situ concrete


MEASUREMENT RULES
condilions or on further drawings M 1 Except where otherwise stated, formwork is measured to concrete surfaces of the finished structure which require temporary support during casting M2 Curved work is so described with the radii stated

INFORMATION PROVIDED
PI The following information is shown either on location drawings under A Preliminaries/General which accompany the bills of quantities: (a) the relanve positions of concrete members (b) the size of members (c) the thickness of slabs (d) the permissible loads in relation to casting times

DEFINITION RULES
01 Plain formwork surfaces

COVERAGE RULES
C 1 Formwork is deemed 10 indude adaptation to accommodate projecling pipes, reinforcing bars and Ihe like C2 FormWOrk is deemed to include all cutting, splayed edges and the like

SUPPLEMENTARY INFORMATION
S 1 Kind and quality of materials and propping requirements for permanent formwork S2 Basic finish where not at the discretion of the Contractor

are those which contai n no


steps. rebates, pockets or other disccn~nuilies 02 Formwork leI! in is Ihal which is not deSigned to remain in position but is nonetheless impossible to remove

03 Permanent formWOl'k is
thai which is designed 10 remain in position

CLASSIFICATION TABLE
1 Sides of foundations 1 Plain vel1ieal 1 Height> 1.00 m
f---------+----I

m~ m

1 LeI! in 2 Permanent

2 Sides of ground beams and edges of beds 3 Edges of suspended slabs


4 Sides of upstands 5 Steps in lop surtaces

2 Dimensioned description

2 Height S' 250 mm

M3 Passings 01 ground beams are not deducted from area of formwork

04 Foundations include bases and pile caps


05 Edges of suspended slabs exclude those associated wilh attached beams at slab peri meters

3 Height 250 - 500 mm


4 Height 500 mm - 100 m

6 Steps in soffits
7 Machine bases and plinths 8 Soffits of slabs 9 Soffits of landings (nr) 1 Slab thid\fless

s 200

mm

1 Horizontal 2 Sloping S 15 3 Sloping>


Q

m1

1 Height 10 soffit S 1.50 m 2 and thereafter in 1.50 m stages 3 Leftin 4 Permanent

2 and thereal!er in 100 mm stages 1 Size of mould and profile. centres of mould. and slab Ih ickness stated

~--------------+-------------~
10 Soffits 01 coffered or troughed slabs

15°

M4 Voids:; 5.00 m1 irrespective of location are not deducted from the area measured M5 Soffits of coffered or lroughed slabs are measured as if to a plain surface M6 The thickness stated of the coffered or troughed slabs is measured overall M7 Top formwork is measu red for su rtaces slopi og > 150 or where otherwise specifically required

06 Formwork to soffits of slabs includes formwork 10 landings occurring at floor levels 07 Soffits of coffered or !roughed slabs include margins which are s 500 mm wide

11 Top formwork

j----------t 1 Left in 2 Permanent

E20 continued
CLASSIFICATION TABLE
12 Wa.lIs 1 Vertical 2 BaHered

II
MEASUREMENT RULES
ml
1 Heig ht >

DEFINITION RULES
D8 Walls include isolated columns and column casings whose length on pi ani s > fa ur tim es thei r th icl\fl ess

COVERAGE RULES

SUPPLEMENTARY INFORMATION

3.00 m above

floor level 2 Interrupted

3 Toone side only, wall


thicK~ess a~d background to other side stated 4 Left in

M8 Voids s 5,00 ml irrespective ouocanon are not deducled from the area measured fa r walls M9 The area measured lor walls whose height is > 3.00 m includes the area below 3.00 m high Ml0 The area of wall kickers is not deducted

5 Penmanent to both sides


6 Permanent to one side only, wall thickness and backgrou nd to other side staled 13 Beams (nr) 14 Beam casi ngs (nr) I Attached to sla bs 2 Attached to walls 3 Isolated 1 Regu lar shaped, shape slated 2 Irregular shaped, dimensioned diagram m1 1 Heig ht 10 sofli I
S;

1.50 m

2 an d thereafter in 1,50 m stages

3 Left in
4 Permanent

MIl Passings 01 subsid iary beams or 0 Iher projectio ns are not deducted from areas 01 formwork but such intersections are deemed to constitute the commenc-ement of an additional member M12 Formwork to edges 01 suspended slabs associated with attached beams at slab perimeters is included with the measurement of the formwork to such beams M 13 Recesses, nibs or rebates wh ich OCCU r in beam or column lormwork measured in accordance with 13 -16.'1;-,2.-:+' are included in the measurement ot such tormwork

D9 Where a downstand beam is formed by tempor~ry fa rmwork bu t III e slab is supported by permanent formwork the downstand beam IS regarded as an isolated beam Dl(l Regular shaped includes rectangular. circular. hexagonal or other definable regular shape

C3 Formwork 10 beams,
columns and casings is deemed to include ends

15 Columns (nr) 16 Column casings [nr]

1 Attached to walls 2. Isolated

I Height> 3.00 m above floor level 2 left in 3 Permanent

17 Recesses Inri 18 Nibs (nr)


19 Rebates (nr)

1 Dimensioned description

1 Extra over the formwork in which th ey occu r 2 Lel1 in 3 Permanent

M 14 Recesses, nibs and rebates are only measured as extra over on superficial items of tormwork

C4 Formwork to recesses is
deemed 10 include ends

20 Extra over a basic linish


for tormed finishes

1 Slabs 2 Walls 3 Beams 4 Coumns 5 Others. stated

ml

Dl1 Formed fimshes are those where a fin ish other than a basic finiSh is required

S3 Details 01 formed linishes

21 Wall kiokers 22 Susperlded wall kickers

1 Laflin

2 Permanent
1 Plain 2 Dimensioned descriplion 1 Width> 1.00 m 2 Width.,; 250 mm ml m

23

Wall ends, SDffits and steos in walls

MIS Formwork to wall kickers is measu red a 10 fig th e centre Iine 01 th e wa II and is deemed 10 include both sides

S4 Height wh ere specitically required

24 Openings in walls

3 Width 250 - 500 mm


4 Widlh 500 mm - 1,00 m 25 Slai rflighlS (nr) I Width 01 stairflighl stated, waist and risers described 1 Stri ng, width slaled --~-------------2 SIri ng, di me nsioned diagram m 1 Lehin 2 Permanent 3 J unction with wall M16 La ngth s 01 stai Ifl igl1ts are measured between top and bottom rlosings M17 Widt!lS are measured overall

C5 Formworl\ to stai Ifti ghts


is deemed to incl ude soffits, risers and strings

-----------_----2 Dimensioned 26 Mortices 27 Holes diagram 1 Depth"; 250 rnrn m 2 Depth 250 - 500 mm 3 Depth 500 mm - 1.00 m
I

1 Girth.,; 500 mm 2 Girth 500 mm -1.00 Slages

nr

1 R eClangula r 2 Circular

012 Mortices include pockets 013

3 and thereafter in 1.00 m

3 Irreg u lar shape.


dimensioned 4 left. in description

4 Depth> t ,00 m depth staled

.,; 5.00 rn'

Holes are ihoss

5 Permanent 28 Complex shapes


1 Dimensioned descrip~on 2 Dimensioned diagram nr I Left in 2 Permanent

-----------------

E30

Reinforcement for in situ concrete


MEASUREMENT RULES
conditions or

INFORMATION PROVIDED
PI The following information is shown either on location drawings under A Preliminaries/General which accompany the bills 01 quantities: (al the relative positions of concrete members (b) the size of members (e) the thickness of slabs (d) the permissible loads in relaton to cas~ng times

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION
SI Kind and quality of materialS S2 S3 Details 01 tests Bending reslrictions

on further

drawings

CLASSIFICATION TABLE
1 Bar 1 Nominal size stated 1 Straight 2 Bent 3 Curved t 1 Horizontal, length 12.00 15.00m 2 and thereafter in 3.00 m stages 3 Vertical, length 6.009.00 m 4 and thereafter in 3.00 m stages 4 Links 2 Spacers and chairs 3 Sped al joint 1 Dimensioned description 2 Nominal size and type stated Ml The weight of bar reinforcement excludes surtace treatments and rolling margin M2 The stage lengths in the fourth column are the lengths before bending 01 Horizontal bars include bars sloping s 30° from horizontal 02 Vertical bars include bars sloping> 30° from horizonta.1 Cl Bar reinforcement is deemed to include hooks and tying wire, and spacers and chairs wtlich are at the discretion 01 the Contractor

or

M3 Spacers, chairs and special joints are measured only where they are not at the discretion of the Contractor 1 Bent 2 Sirips in one width, width staled M4 T he area meas ured for fabric excludes laps, M5 Voids S 100 m2 in area are not deducted C2 Fabric reinforcement is deemed to include laps, tying wire, all cutting and bending, and spacers and chairs which are at the discretion of the Contractor C3 Bent fabric reinforcement is deemed to include that wrapped around steel members

4 Fabric

1 Mesh reference and weight per m2 slated

ml

54 Minimum laps

E31

Post tensioned reinforcement for in situ concrete


PROVIDED MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION

INFORMATION

PI The following information is shown ei1tw on location drawings under A Preliminaries/General which accompany the bills of quanti1ies: (a) the relative positions of concrete members (b) the size 01 members (c) the thicklless of slabs (d) the permissible loads in relation to casting limes CLASSIFICATION TABLE

conditions or on further drawings

1 Members tensioned (nr)

1 Dimensioned description

nr

1 Composite co nstruction

Ml Post tensioning is measured by the number of tendons In identical members

51 Number, length.
material and size 01 wires in tendons

52 Ducts. vents and grouting


53 Anchorages and end treatment S4 Stressing sequence. transfer stress. initial stress S5 limitation on propping

E40

Designed joints in in situ concrete


PROVIDED MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION

INFORMATION

PI Information is shown on location drawings under A Preliminaries/General CLASSIFICATION TABLE

conditions

Ml Construction joinls located at ltIe discretion of the Contractor are nol measured m 1 Curved M2 The width or depth of join Is ism easorec over all Ot Plain joints are those which do not require formwork Cl Formed joints are deemed (0 include formwork

SI Kind and quality 01


materials

1 Plain 2 Formed 3 Cut 4 Sealants

1 Width or depth :5 150 mm 2 and thereafter in 150 mm stages

1 Dimensioned

description

S2 Details of fillers, waterstops. dowels. backi n9 strips and reinforcement crossing joints S3 Method of application S4 Preparation 01 contact surfaces, cleaners, primers and sealers

C2 Work is deemed to indude preparation. cleaners, primers and sealers

r-5 Angles in waterstops 6 Intersections in walerstops nr M3 Angles and intersections are measured only where Ihey are welded or pu rpose made

E41

Worked finishes/Cutting to in situ concrete


MEASUREMENT RULES
conditions Ml Curved work is so described

m
DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION
SI Description of finish required and method 01 achieving where not at the discretion of the Contractor

INFORMATION PROVIDED
PI Informanon is shown on location drawings under A Preliminaries/General

CLASSIFICATION TABLE
1 Tamping by mechanical means 2 Power floating 3 Trowelling 4 Hacking 5 Grinding 6 Sandblasting 7 Finishings achieved by other means 8 Cutting chases 9 Cutting rebates 1 Depth s 50 mm 2 Depth 50 -100 mm 3 Depth 100-150 mm 4 Depth> 150 mm, depth staled m 1 Specific width slated 2 Making good 3 In reinforced concrete m2 1 Sloping 2 Falls 3 Crosslalls 4 Soffits

M2 Width is required to be stated only where there is a specific width requirement

10 Cutting mortices 11 Cutting holes

1 Oepth $100 mm 2 Depth 100- 200 mm 3 Depth 200 - 300 mm 4 Depth> 300 rrrn. depth stated

nr

1 Specific cross sectional size stated 2 Making good 3 In reinforced coner ete

M3 Cross sectional size is required to be stated only wh ere there is a Specific cross sectiooal size requirement

E42

Accessories cast into in situ concrete


PROVIDED MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION

INFORMATION

PI The tolklwing inlormation is shown either on location drawings under A Preliminaries/General condi~ons or on further drawings
which accompany the bi 115 qu an~ties: of (a) the relative positions of concrete members (b) the size of members (c) the thk:lmess of slabs (d) the permissibje klads in relation to casting times CLASSIFICATION TABLE

I Type or name stated

I Dimensioned description

ml m or

--

1 Spacing dim ensions stated

--

Ml Casl-in accessories are normally measured by number (nr). linear or area measure may be used provided that any appropriate spacing dimensions are given in descriptions

Dt cast-in accessories include anchor bolls, anchor boxes, anchor fixing bolts etc. dowels, column guards and isolated glass lenses. Cast-in accessories exclude remtorcement, tying wire, distance blocks, spacers, chairs, structural steelwork, hollow blocks, filler blocks, permanent formwork, joints and all components around which concrete is cast but which are not fixed by the Contractor

SI Kind and quality of materials and sizes or manufacturer's reference

E50 Precast concrete frame structures F31 Precast concrete si lis/I inte Is/copi ngs/features
H40 Glassfibre reinforced cement panel cladding/features H42 Precast concrete panel cladding!features H50 Precast concrete slab cladding/features K33 Concrete/Terrazzo partitions
INFORMATION PROVIDED
Pl The following inlormation is either shown on location drawings under A Prelimina.rieslGeneral which accompany the bilts 01 quantities: la) details 01 precast concrete members showing stressing arrangements (b) lull details of anchorages, ducts, sheath ing and vents (c) the relative positons of concrete members (d) the siza 01 members (e) til a thickness 01 slabs (I) the permissible loads con(ji~ons or on further drawings

ED

MEASUREMENT RULES

DEFINITION RULES

COVERAGE RULES

SUPPLEMENT ARY INFORMATION

CLASSIFICATION TABLE
1 Type or name stated 1 Dimensioned description 2 Dimen sioned description (nr) 3 Dimensio ned descn ption I Floor u nits. length stated nr t Reinlorceme nt, datai Is staled 2 Casl-in accessories. detai Is staled Mt Precast unts are normal~ measured by number (m). Linear measurement may be used wh ere the length 01 u nits is at the discretion of Ille Contractor, where the individua I u nits are 01 an identical stand ard length, or where otherwise idenbcal units vary in their length, In these cases the nu moor 01 u nits is stated M2 Where floor units are of the same length they may be measured in square metres and grouped together stating length 2 Ilems extra over the unils on whtch they occur 1 Angles 2 Fair ends 3 Stoolings 4 Others, details slated 3 Joints I Dimensioned prolile description 2 Dimensioned descriptiM 1 Sizes 01 lillin 9 and sealants slated m nr MJ Where units are measu red Iinea r, an gles, fair ends, stooliog$ and Ihe like are enu me ra.ted as ex Ira over the un its M4 Enumerated join Is ma~ be given in the description 01 the precast items in which they occur Ct Precast u nijg are deemed to include moulds, reinforcement, bedd.i ng, fixings, temporary supports, cast·i n accsssores and pretensioning SI Kind and quality of materials and mix details S2 Tests of materials and Iinish ed work

r---m

ml

53 54
S5

Melhods ot compaction and curing Bedd ing and fixing Surface finishes

S6 Kind and quality of pretensioning materials, spacing and stresses

S7 Ki nd and quality 01
materials

~
nr

E60

Precast/Composite concrete decking


MEASUREMENT RULES
Mt The thickness stated lor composite stabs is measured overa.11 M2 Composite slabs are measured over margins s 500 mm wide M3 Margins> 500 mm wide are measured as ordinary Slabs in Sections El 0., E20 and E30

1NFORMAT10N PROVIDED
conditions or on further drawings PI The following information is shown either on location drawings under A PreliminarieslGeooral whfch accompany the blll of quantities: (a) details of purpose-made, prestressed concrete members showing stressing arrangements (b) lull details 01 anchorages, ducts, sheathing and vents (c) the relative positions 01 concrete members (d) the sile 01members (e) the thickness of slabs (I) the permissible klads

DEfiNITION RULES
01 Composrte slabs inelude margins::; 500 mm wide, wider margillS are included with ordinary slabs

COVERAGE RULES
Cl Composite slabs are deemed to inelude solid concrete work and filling ends

SUPPLEMENTARY INFORMATION
SI Kind and quality of materials, sizes and spac ngs of planks and blocks S2 S3 Top finish Soffit finish

54 Margins
S5 Formwork

CLASSifiCATION TABLE
1 Composite slabs t Thickness stated m1 1 SkJping s 15° 2 Sklping.> 15° 2 Formw()rk

56 Reinforcement and
preS1!essing arrangements

M4 Formwork to in situ component 01 work is measured in accordance with Sec~on E20 M5 Rei nforcement to in situ component 01 work is measured in accordance with Section E30

3 Reinforcement

F Masonry
F10 F11

Brick/Block walling Glass block walling


MEASUREMENT RULES
Ml Brickwork and blockwork unless otherwise stated are measured on the centre line of the ma.terial M2 No deductions are made for the following: (a) voids 5 0.10 m1 (b) flues, lined !lues and lIue btocks where voids and work displaced are together $ 0.25 m' M3 Deductions for string courses. lintels. sills, plates and the like are measured as rega rds heig ht to the exte nl on Iy of lull brick or block courses displaced and as rega rds depth to t.he extent only of full hall brick beds disptaced

INFORMATION PROVIDED
P1 The following information is shown either on location drawings under A Preliminaries/General conditions or on further drawings which accompany the bills of quantities: (a) Plans of each floor level and principal seclions showing the poston 01 and the materials used in the walls (b) External efevations showing the materials used

DEFINITION RULES
01 Thickness stated is nominal thickness unless defined otherwise betow D2 Facework is any wor k in bricks or blocks finished fair 03 Work is deemed vertical unless otherwise described 04 Walls include sk.ins of hollow walls

COVERAGE RULES
C1 Brickwork and blockwork are deemed to include (a) extra materials for curved work r (b) a.11ough and fa.ir wiling Ie) forming rough and lair grooves. throats, monioes, chases, rebates and holes, stops and mitres (d) raking out joints to form a key (e) labours in eaves filling (f) labours in returns, ends and angles (g) centering

SUPPLEMENTARY INFORMATION 51 Kind, quality and size of bricks or btocks


Composition mortar

52 53

Type 01 bond and mix 01

54 55

Type of pointing

Method 01 culling where not at the discretion of the Contractor

CLASSIFICATION TABLE
1 Walls 2 Isolated piers

M4 Cu rved work is so described with the radii stated

1 Thickness stated
2 Facework one side, thickness stated 3 Facework both Sides. thickness stated

1 Vertical 2 Battering

m2

1 Building against other work 2 Bo ndi ng to other work 3 Used as formwork. d eta iIs of temporary strutting staled 4 Buildi ng ave rh a nd

3 Isolated casings
4 Ch i mney stacks

3 Tapering, one Side


4 Tapering, both sides

M5 Building against other work and bonding to other work is measured where the other work is existing or consists of a dinering material

05 Battering walls are sloping walls with parallel sides 06 Tape ring walls are walls of dimi nishi ng th ickn ess 07 Thickn ess sic led lor tapering walls is mean thickness 08 Isolated piers are isolated walls whose length on plan is $ four times their thickness, except where caused by openings

C2 Brickwork and blockwork bonded to another material is deemed to include extra material tor bonding

5 PrOJections

1 Width and depth 01 projection stated

1 Ver1ical 2 Raking 3 Horizontal

D9 Projections are attached piers Iwhose length on plan is," four times their thickness), plinths, oversailing courses and the like M6 Arches are measured the mean girth or length on face

6 Arches (nr)

1 Height on lace, thickness and width of exposoo soffit and shape 01 arch stated 1 Th ickn ess stated 1 Siz e on plan, sha pe and overall height stated

7 Isolated chimn ey shafts and the like (nr)

ml

1 Building from outside

scaffolding m' M7 Non brick masonry flue linings are measured in Section F30:1 1.10.0

8 Boi ler seati ngs


9 Flue linings

1 Thickness slated

10 Boiler seating kerbs 11 hems extra over the work in which Uley occur 1 Shape and size stated 1 Specials, di rnensionec description 1 Reveals 2 Angles m m

3 Intersections
12 Closing cavities 1 Width of cavity and method of closing stated 1 Venical 2 Raking 3 Horizontal 13 Facework ornamental bands and the like, type stated 1 Flush 2 Sunk, depth of set back stated 3 Projectj ng, depth of set lorwa rd stated
1 Venical, width slated

2 Raking, width stated 3 Horiz on tal, widl h stated 4 Others, details staled

1 Extra over the work in which the)' occur 2 Entirely of stretchers 3 Entirely of headers 4 Building ove rhand

010 Radii stated are mean rad ii on face 011 Facework ornamental bands and the like are brick· on-edqe bands. brick-on-end bands, basket pattern bands, moulded or splayed plinth cappings. moulded string courses, moulded cornices and the like M8 Facework quoins are measured on the vertical angle 012 Facework quoins are formed with facing brids which diHer in kind or size from the gene raI 1aci ngs S6 Method of JOinbng quoins to brick or blockwork

14 F acework quoins

1 Flush 2 Sunk, depth 01 set back stated 3 Projecting. depth of set forward slated

1 Mean girth stated

1 Extra over the work In which they occur 2 Cut and rubbed 3 Rusticated 4 Tile inserts included

5 Bu iIding eve rhand

F10/F11 continued CLASSIFICATION TABLE


s 15 Facewor1ol ills 16 Facework thresholds 17 Facework copings s 18 Facewor1ol teps
19 Facewor1olumblings to t

MEASUREMENT RULES
1 Dimensioned description
, Vertical

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION
S7 Method ollorming sills, threshotds, copings and steps

2 Raking 3 HorizontaJ 4 Others, delails stated


1 Extra over the work in

1 Extra over !he wor1ol in which they occur 2 Buildin9 overhand 3 Set weathering

nr

buttresses 20 Facewor1ol ey blocks k 21 Facewor1ol orbels c 22 Facewor1ol ases to b pilasters 23 Facewor1ol appings to c pilasters 24 Facewor1ol appings to c isolated piers 25 Bonding to existing
1 Thickness 01 new wor1ol

which they occur

stated 26 Surface treatments


1 Type and purpose slated

1 Type of wall stated

m2

013 This ilem does not include appflcation of materials 10 the wall

F20 Natural stone rubble walling F21 Natural stone ashlar walling/dressings F22 Cast stone ashlar walling/dressings
INFORMATION PROVIDED
PI The following information is shown el1her on location drawings under A Preliminaries/General conditions or on further drawings which accompany Ihe bilts 01 quantities: (a) plans of each floor level and principal sections showing the position of and the materials used in the walls (b) external elevations showing the materials used

MEASUREMENT RULES
Ml Stonewoll<. is measured according 10 mean dimensions
M2 No deductiOn is made for: (a) voids S 0.10 m2 (b) flues, lined flues and flue blocks where voids and woll<. displaced are together S 0.25 m2 M3 Linear and enumerated items shall identify grooves, throats, flutes, rebales, cutting and mortices M4 Curved work is so described with !he radii stated

DEFINITION RULES
01 The thickness staled is the nominal thickness except where deli ned olhe!Wise below 02 Slone dressings are those in walls 01 other materials 03 Dimensioned diagrams are given unless a written description is sufficient for lull clarity 04 WorK is deemed vertical unless othe!Wise described

COVERAGE RULES
CI The woll<. is deemed 10 include: (a) exira. stone for joints (b) extra materials tor curvedwoll<. (e) mortices, (other than linear rtems) holes, stops and amses (d) raking oul joints to form key (e) metal cramps, slate dowels, metal dowels, lead plugs and the like (f) labours in eaves filling (g) labours in returns, ends and a.ngles (h) dressed margins to rubble Wllrk (j) levelling uncou rsed work (k) tempiets and patterns (I) rough and fair square cutting

SUPPLEMENTARY INFORMATION
SI Kind and quality 01 materials and, 101rubble walling, whether of random Or squared stones, buill wtIh or without mortar and where coursed the average height of the courses Of maximum and minimum heights of diminishing course $2 Coatings to backs 01 stones 53 Coatings 10 surface of finished work 54 Cleaning on completion and mix of

55 Composition mortar S6

Type of pointing

57 Method of jointing together and fixing S8 Thickness, mix and colour of !he fad rtg material to cast stonework S9 Stones not set on their natural bed 510 Type and positioning of metal cramps, slates, dowels, metal dowels, lead plugs and the like

F20lF21/F22 continued
CLASSifiCATION TABLE
1 Walls 2 Chimney stacks 1 Thickness stated 1 Venical 2 Battering 3 Taperi ng, one side 4 Taperi ng, both sides

MEASUREMENT RULES m1
1 Blocks> 1.50 m long 2 Blocks> 0.50 ml 3 Slone dressings 4 Faced one side 5 Faced both sides 6 Building against other work 7 Building againsl other battered work 8 Bonding to other work 9 Sunk to entasi s, greatest size stated 10 Plain 11 Sunk t2 Circular 13 Circular -aroul ar 14 Rustk:a!ed or flu ted 15 Used as lormwork, detailS 01 temporary slrut1in 9 slated 16 Wilh sloolinqs (m) 17 Band courses with returned ends (nr) 18 Building overhand M5 Building against othel ' work and bondi ng to other work is measured where the other work is existing 0 r consists 01 a diHering male rial

DEFINITION RULES
05 Battering walls are sloping walls with parallel sides 06 Tapering walls are walls 01 diminishing thickness 07 Thickness stated lor tapering walls is mean thickness 08 Walls include skins 01 hollow walls 09 Columns are walls whose length on plan is s lour fimes their th iclmess, except where caused by openings 010 Attached columns include attached piers and pilasters

COVERAGE RULES
C2 Battering and tapering walls are deemed to include the extra materials required C3 Work is deemed to include exira materi al tor bonding

SUPPLEMENTARY INFORMATION
511 Method 01 bonding to backing
S12 Type and spaci ng 01 1ixing and method 01 securi n9 to backi ng

3 Isolated columns 4 Attached columns 1 Dimensioned description m

Dl1 The dimensioned description stated 101 attached colum ns rele rs 10 the projection only

5 Vaulting 6 Lintels 7 Sills 8 Mullions 9 Transoms 10 Quoin stones 11 Jamb stones

1 Thickness and type stated 1 Dimensioned description --~~~--~~~~~~~~~2 Dimensioned diagram

m'
'I----

1 Mached 2 Attached with different fin ish. type 01 finish stated 3 Isolated

1 Dimensioned descrip~on

M6 Quoins and jambs are measur ad on me vert.ical angle

012 AUaehed slo nes are Ihose attached to the same type 01 stone wailing 013 Isolated stones are those attached to another lorm 01 construction

t 2 Slab areh itrave s

t Dimensioned descripti 0 n

13 Slab surrounds to
openings

014 Slabs are those which are not bonded to their surrounding work

14 Bands and the like, type stated 15 Corbel courses 16 Copings

1 Vertical

2 Raking
3 Horizontal 4 Others, detai Is stated

17 Handrails
18 Cappings 19 Kerbs

M7 Mo uldi ngs are only measured separately on superficial items of masonry and attached piers. Mouldi ngs are given in the description 01 Iinear items

015 Band courses and the like include mouldings, enrichments, cornices and the like 016 Plain bands> 300 mm wide are measured as walling or faceworll

20 Cover stones 21 Steps (or)


1 Plain 2 Spandrel 22 Winders 23 Landings 24 Arches (nr) 1 Heighl 01 lace, width of soffit and sh ape of arch stated m 1 Stones (nr) nr m 017 Spandrel steps are steps with sloping soffits

nr

--

M8 Arches are measured the mean girth or length on face M9 The quantity (nr) is only stated in an item which is meas urad Iinearl y

25 Closing cavities

1 Widlh of cavity and melhod of closing stated

1 Vertical 2 Raking 3 Horizontal

26 Rough raking or circular cutting 27 Fair raking or circular cuMing 28 Grooves 29 Throats

1 Th ielln ess staled


I

1 Size stated

30

Flutes

31 Rebates

MtQ Grooves, throats, flutes, and rebate s are on Iy measured separatety on superficial items 01 masonry and attached piers

32 Chases

1 Rough

1 Girth $ 150 mm 2 and thereafter in 150 mm stages

2 Fair

F20/F21/F22 continued
CLASSIFICATION TABLE
33 Special purpose stones 1 Function stated 1 Plain cuboid. dimensions stated 2 Dimensioned description nr

MEASUREMENT RULES
Mil Descriptions of stones are given as the smattest block from which each item can be obtained having regard in the case of natural stone to the plane in which the stone is required to be laid with relation to its quarry bed. The dimensions are taken over one mortar bed and one mortar joint
1 Providi ng models

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMA nON

34 Carvings 35 Sculptures

1 Character of work staled

1 Component drawing

nr

C4 Carvings and sculptures are deemed to include: (a) selecting blocks of stan e for size and quality (b) boasting for calVing (c) working mouldings or similar members M 12 A dimensioned description of centering gives the shape and width of the surface to be supported. the span of the soffit. and, in the case of arches. whether segmental, semicircular. invert and the like. stating the rise C5 Centering is deemed to Include: (a) strutting. shoring, bolting. wedging, easing. striking and removing {b) cutting (e) scribed and splayed edges (d) notchi ng for key blocks. projecting voussiors and the like S13 Nature of supported surface

36 Centering

1 Arches 2 Tracery

1 Dimensioned description

nr

1 Sloping soffits 2 Maximum support height 3.00 - 450 m 3 and thereafter in 1.50 m stages 4 left in

J Projecti ng mason ry
4 Vaulting

F30

Accessories/Sundry items for brick/block/stone walling


MEASUREMENT RULES
Ml Curved work is so described

INFORMATION PROVIDED PI
The following information is shown either on location drawings under A Preliminaries/General conditions or on further drawings which accompany the bills of quantities: (a) plans of each floor level and principal sections showing the position 01 and the materials used in the walls (b) external elevations showing the materials used

DEFINITION RULES

COVERAGE RULES
Cl Accessories are deemed to include: (a) rough and fair cutting on walls around accessories (b) bedding and poi nting accessories (c) extra materials lor curved work

SUPPLEMENTARY INFORMATION
SI Kind and quality 01 materials

CLASSIFICATION TABLE
1 Forming cavities 1 In hollow walls 2 Between walls and other work 1 Width of cavity stated m2 1 Rigid sheet cavity insulation, thickness stated

S2 Type, size and spacing 01 wall ties S3 Type, thickness and method of fixing cavity insulation M2 No allowance is made tor laps M3 No deduction is made for voids::; 05{J m2 C2 Damp proof courses are deemed to include pointing exposed edges S4 Gauge, thickness or substance of sheet materials S5 Number of layers S6 Composition and mix of bedding materials S7 Minimum laps

2 Damp proof courses

1 Width s 225 mm 2 Width> 225 mm

1 Vertical 2 Raking 3 Horizontal 4 Stepped

m2

1 Cavity trays

3 Joint reinforcement

1 Wfdth stated

4 Weather fillets 5 Angle fillets 1 Size stated

M4 No allowance is made for laps C3 Fillets are deemed to include ends and angles M5 Flashings are measured in Sections H70-H76

t-6 Pointing in flashings m

C4 Poi nling in flashings is


deemed to include cutting or forming grooves or chases

7 Wedging and pinning 8 Joints

1 Width 01 wall stated

I--m I-m M6 Joints are only measu red where desig ned C5 Work is deemed to include lXepara~on, cl eaners, primers and sealers S8 Type of filler and sealant S9 Method of application S10 Preparation of contact surfaces, cleaners, primers and sealers

1 Dimensioned description

9 Slates and Ii IeS lor creasing to Slate and tile sills

1 Width stated

1 Courses (01)

C6 Slates and tiles tor creaSing and sills are deemed to include ends, angles and pointing

F30 continued
CLASSIFICATION TABLE
11 Flue linings 1 Dimensioned description m

MEASUREMENT RULES
M7 Brick IIue linings are measu red in SeC1.ion

DEFINITION RULES

COVERAGE RULES
C7 Ftue linings are deemed to include: (a) cuning to form easings (b) cutting to form bends (c) cutting to walls around linings C8 Air bricks, ventilating gratings, soot doors and the Iike are deemed to include any necessary forming of openings, liners, cavity closers and damp proof

SUPPLEMENTARY INFORMATION
S11 Method 01 buitding

Fl0:91.00

12 Air bricks 1 J Ve ntilati ng gratings 14 Soot doors

1 Size of opening, nature and thickness of wall stated

nr

1 Untels, details stated

2. Arches, details staled

courses

15 Gas flue blocks

1 Size 01 block and number of flues in each stated 1 Dimensioned description 1 Manufacturer's reference

f--nr

S12

Method of building

16 Proprietary

items

nr

S13

Method of fixing

G Structural/Carcassing metal/timber
G10 G11 G12

Structural steel framing Structural aluminium framing Isolated structural metal members
MEASUREMENT RULES on further
drawings

INFORMATION PROVIDED
PI The following information is shown either on location drawngs under A Preliminaries/General conditions or which accompany the bills of quantities: (a) the position of the work in relalion to other parts 01 Ihe work and of the proposed buildings (b) the types and sizes of structural members and their positions in relation to each other (c 1 details of connections or of Ihe reactions, moments and axial loads at connection points

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION
SI Types and grades 01 materials S2 Details 01 welding tests and X-rays S3 Details of performance tests

CLASSIFICATION TABLE
t Framing, Iabricanon
1 Columns 2 Beams 3 Bracings 4 Purlins and cladding rails 5 Grillages 6 Overhead crane rails 1 Details of fixing clips and resilient pads stated

1 Weig ht s; 40 kg/m
2 Weight 3 Weig ht

1 Castellated 2 Tapered 3 Curved 4 Cambered 5 Hollow, shape stated

40-100 kg/m

> 100 kg/m

Ml The mass of framing includes all components except fittings


are all grouped together irrespective of the member to which they are attached M3 The mass of framing is measured from their overall lengths with no deductions lor splay cuts or mitred ends or for the mass of metal removed to form notches and holes each < 0.10 m' in area measured in the plane M4 No allowance is made for the mass of weld fillets, black bolts, nuts, washers, rivets and prot ectiv e watings M5 The mass 01 steel is taken tor measurement as 785 kglm1 per 100 mm thickness (7.85 tfm)); the mass of other metals is stated

01 Fabrication includes all


operations up 10 and including delivery to srte

M2 Fittings

02 Purlins and claddmg rails are measured by weight when hal rolled 03 Wires, cables. rods and bars include sag rods, ties and the like
04 Special bolts and fasteners are those other than black bolts and holding down bolts or assemblies

Cl Items lor fabrication measured by weight are deemed to indude shop and site black bolts, nuts and washers for structural framing to structural framing connecnons

7 Trestles, towers and built up columns

1 Details of construction
stated

Trusses and built up girders

9 Wires, cables, rods and bars

10 Fillings
tl Hotding down bolts or assembfies 1 Details slated nr

12 Special bolts and


fasteners

1 Type and diameter stated

:> Framing, erection

1 Triat erection

:> Permanent erection on


site 3 Permanent formwork

05 Erection includes all operations subsequent to fabrication 1 Curved 06 Permanent lormwork is that which is structurally integral with the framing

1 Type and method of fixing


stated

ml

4 Cold rolled pUflins and cladding rails 5 Isolated structural member

1 Type and method of fixing slated 1 Plain member stated use 1 Weight 2 Weight 3 Weight ::::;40kg/m

1 Castellated 2 Tapered

3 Curved
4 Cambered 5 Hollow, shape Slated

2 Built-up member use and details of construct ion stated

40-100 kg/m > 100 kg/m

M6 The mass of built up members is calculatad as defined from 'Framing, fabrication' M7 Fixing bolts are measured in accordance with the rules contained in Section G20 :25_ .0.0

3 Fittings 6 Filling hollow sections 1 Water 1 Details stated item

07 An isolated structural member is 8 member not part of H framing as measured under 1.1 -12 08 Use is defined as 1.1 - 1.9 inclusive 09 FixinQ bolts are bolts fixin~ an isolated structural mem er to another element

C2 Isolated structural members are deemed to include fabrication and erection

:> Concrete
7 Surface preparation 1 Blast cleaning 2 Pickling 3 Wire brushing 4 Flame cleaning 5 Others, details staled
I

m2

S4 Type of preparation, details of application and timing

Surlace trealmenl

1 Galvanising 2 Sprayed metal coating 3 Protective painti ng 4 Others, details staled

m2

_____,
m2 M8 Localised protective coating is only meas urad to structural aluminium lraming 010 localised protective coatings are localised applications to surfaces in contact with dissimilar metals and aggressive building materials

9 Localised protecbve coating

1 Type stated

G20

Carpentry!Timber framing/First fixing


MEASUREMENT RULES
conditions or on further drawings

INFORMATION PROVIDED
PI The following information is shown eilher on location drawin:gs under A Preliminaries/General which accompany the bills ot quantities: (a) Ih e scope and location 01 th e worll

DEFINITION RULES
01 All sizes are nominal sizes unless staled as finished sizes

COVERAGE RULES
Cl The work is deemed to include labours on ilems at limber, excepl as olherwise requried

SUPPLEMENTARY INFORMATION
SI Ki nd and quality of materials and if limber whether sawn or wrol S2 Method of fixing where not at the discretion of the Contractor S3 Fixing through vulnerable materials

CLASSIFICATION TABLE
1 Trusses
2 Trussed rafters 3 Trussed beams 4 Wall or partition panels 5 Portal trames 6 Floor members 7 Wall or partition members 8 Plates 1 Dimensioned description m 1 Lenglh > 6,00 m in one continuous length, length stated 1 Dimensioned description nr 1 Stopped labou rs (nr) C2 The work is deemed to include webs, gussets, etc,

54 Preservative Ireatments applied as part of the production process S5 Surface treatments applied as part of the production process

02 Floor members include


joists and beams

S6 Selection and protection for subsequent treatment S7 Matching grain or colour Umits on the planing margi ns and if deviation trom the stated sizes is not permitted

03 Partiijon members
include struts and noggings 04 Plates are mose to structural elements only and include bearers

sa

9 Roof members

1 Flal 2 Pitched

05 Flat roof members include joists and bea ms D6 Pitched root members include struts, purlins, rafters, hip and valley rafters, ridge boards, ceiling joists, binders and braei ng

59 Method of jointing or form of construction where not at the discretion of the Contractor

to Joist strutting

1 Herringbone, depth of joist stated

M 1 Strutti ng is measu red over the joists

2 Block, depth of joist stated 11 8uM jointed supports 12 Framed supports


1 Width> 300 mm 2 Width ~ 300 mm 1 Dimensioned overall cross-section descripbon and spacing of the members t Dimensioned overall cross-section description m1 I-m
1 DiHeren!

cross-secton

shapes (nr) 2 Curved, radii stated 3 Stopped labours (nr)

M2 Supports and framed supports are measured overall

07 Supports include grounds, batts ns. firrings, fillets. drips, rolls, upstands, kerbs or Ihe like 08 Framed supports are where the members are Jointed together other than butt jointed

13 tndividual

supports

4 Irregular shaped area 5 Irregular component, details stated

14 Gutter boards 15 Fascia boards 16 Eaves or verge soHit boards 17 Cleats

1 Width> 300 mm 2 Width> 300 mm

1 Dimensioned description 2 Dimensioned overall cross-section description

m2 m

-----------------

M3 Gutter boards and sides are each measured overall as rndivid ual components but grouped together

09 Gutter boards include sides 010 Fascia boards include barge boards

3 Width s 300 mm 1 Dimensioned description nr 011 Cleats include sprockets and the like

18 Ornamental ends
19 Wlot surfaces 1 Plain 2 Irregular 20 Straps 2t Hangers 1 Dimensioned description 2 Dimensioned diagram 1 Widlh stated 1 Girth stated m D12 Wrot surfaces are those on sawn items only

nr

-----------------

M4 The length of a bolt is measured overall the head

013 Bolts include heads, nuts and washers

C3 Work is deemed 10 include all labours in fabricating and fixing C4 Work is deemed to include all accessories

22 Shoes 23 Nail plates 24 Metal connectors 25 Bolts 26 Rod bracing 27 Wi re bracing 28 Others. details stated

G30

Metal profiled sheet decking


MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION SI Kind and quality of materials S2 Meth ad of Iixing and hoisting where not althe discretion 01 Ihe connactor S 3 Method of jointing or torm of construction where not at the discretion of the Contractor

INFORMA TlON PROVIDED

PI The following informalion is shown either on drawings under A Preliminaries/General accompany Ihe bills of quantities: (a) the enem of Ihe work and its height above ground level (b) the size of units where not at the discretion of the Contractor

conditions or on lurther drawings which

DI All siz es are nom inaI sizes unless slated as finished sizes

CI Removalolli"ing devices and consequent making good and making good of handling holes and the like are deemed to be included

CLASSIFICATION

TABLE

S 4 Sur1ace treatments applied as part of the production process I Dimensioned description m' 1 Curved, radii slated 2 Fixing through underlinings 1 Holes 2 Notches 3 Others, deta.ils stated I Off site 2 Onsite nr Ml The number is stated on'Y where the size of unit is not at the discretion 01 the Contractor M2 No cedocton is made for voids sO_50 m'

1 Decking 2 Decking units (01)

3 Items extra over the decking or decking units in which they occur 4 Bearings 5 Eaves 6 Kerbs 7 Abutments 8 Nibs 9 Blocks 10 Fillets 11 Profile fillers

1 Dimensjoned descrip~on

G31 G32

Prefabricated timber unit decking

Edge suppo rted/Rei nforced woodwoo Ilroc kfi bre deck ing
MEASUREMENT RULES
conditions or on further drawings

INFORMATION PROVIDED
Pl The following informaMn is shown either on location drawings under A PreliminariesJGeneral which accompany the bijlls 01 quantities: (a) the extent of the work andi ts heig ht above ground level (b) the size Of units where not at the discretion of the Contractor

DEFINITION RULES
01 All sizes are nomin al sizes unless stated as lin ished sizes

COVERAGE RULES
Cl Removal of lifting devices and consequent making good, and making good 01 handling holes and the like are deemed to be inCluded

SUPPLEMENTARY INFORMATION

CLASSIFICATION TABLE
1 Decking 2 Declling units (nr) 1 Dimensioned description m' 1 Cu rved, radii stated

3 lIems extra over the


decking or decking units in which they occur

1 Holes 2 Notches 3 Others. d eta ils stated

t OHsite
2 On site

nr

Ml The numbe r is slated on ty where the size of u nit is not at the di seretion 01 the Contractor
M2 No deduction is made tor voids s 0.50 m'

51 Kind and quality 01 materials and whether sawn orwrot


S2 Method 01 fixjng and hoisting where not at the discretion of the Contractor

4 WoodwOOI kerbs 5 Woodwool angle filtets 6 Filii ng rebates with insulating strips 7 Isolating strips

1 Dimensioned description

M3 Items 4-7.+.0
on Iy measured under Sec~on G32

* am

53 Method of JOinUng or form of construction where nol at the discretion of the Contractor
S4 Selection and protection for subsequent treatment S5 Surface treatments applied as pari of the

producton precess

56 57

Matching grain or colour

Limits on the pianing margins and ~ deviation trom the stated sizes is not permitted

H Cladding/Coveri ng
H10 H12 H13
Patent glazing Plastics glazed vaulting/walling Structural glass assemblies
MEASUREMENT RULES
condilions or on further drawings

INFORMATION PROVIDED
P1 The following information is shown enher on location drawings under A Preliminaries/General wtlleh accompany the bills of quan~ties: (a) the scope and location ollhe wo rk (b) component drawings

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION
SI Kind, qual ity and thickness of materials S2 Type, finish, length and spacing 01 9 lazing members

Ml No deduction is made lor voids ~ 1,00 m1

CLASSIFICATION TABLE
1 Rools areas (01) 2 Vertical surfaces (nr) ,3 Items extra over the glazing in which th ey occur 1 Single tier 2 Multi-Jier 1 Doors 2 Windows 3 Fixed louvres 4 Adj ustabte louvres 50th ers, d eta iIs stated 1 Dimensioned description nr 1 Contro' gear to single unit, type, method of fixing and distance vertically and horizo ntally Irom un it stated 2 Control gea r to bank of units, type, matn ad of fixing and di stance ve rtically a nd horizon tatty from u nits stated m m1 1 Si led rilling the beari ng s M 2 Glaz ing is measu red over bars Cl Work is deemed to include securing to wood unless otne rwise slated

S3 Nature, thickness and spacing 01 structural suppor1s

4 Raking cutti ng 5 Curved cutting 6 Weatherings, flashings and fixing members at tops, bottoms and sides where part 01 the component t Preformed, gauge staled 2 Extruded, thickness staled 1 Dimensioned description

M3 tabo urs on 9 lazing are


grouped with the glazing to wh ic h they re Iate

m I Site drilling, background slated

C2 Stop ends, mitres and corners are deemed to be included

H11

Curtain walling
MEASUREMENT RULES
conditions or on further drawings MI Timber members which do not have a constant cross-section are so described and given stating the extreme dimensions M2 No deduction is made for voids s 1,00 ml

INFORMATION PROVIDED
PI The following information is shown either on location drawings under A Preliminaries/General which accompany the bills of quantities: (a) the scope and location of the work (b) component drawings

DEFINITION RULES
01 Curtain walling compri ses non loadbeari ng walls of wood or metal framing, fixed as an intergr atsd assembly, complete with windows and opening lights, glazing and infill panels 02 All sizes are nominal sizes unfess staled as finished sizes

COVERAGE RULES

SUPPLEMENTARY INFORMATION

CLASSIFICATION TABLE
1 Curtain walling 2 Items extra over the curtain walling in which they occur 1 Infill panels 1 Dimensioned description 1 Type and thickness stated ml m' 1 Flat 2 Sloping 3 Curved. radii stated 1 Irregular 2 Horizonlal 3 Sloping 4 Vertical 5 Curved, radii stated M3 In~1Ipanels are measured over all framing

Ct Curtain walling is deemed to include all cleats, brackets, bolts and fixings C2 Items include: (a.) doors where supplied with the unit (b) architraves, trims and th e like where part 01 the component (c) ironmongery where supplied with the component (d) finishes where part 01 the component as delivered (e) glazing where supplied with the component (f) mechan ical operation and automatic operating equ ipmenl wh ere supplied with the component (g) mastics/sealants unless executed by a specialist and measured in Section P22 (h) fixings and fastenings

St Kind and quality of materials and if timber whether sawn or wrot S2 Preservative treatments applied as part of the production process S3 Suriace treatments applied as part 01 the production process

2 Perimetsr

1 Heads 2 Sills 3 Abutments

03 Irregular junctions are any ju ndions with angles othe r than 900

3 Angle

1 Internal 2 External

54 Selection and protection for subsequent treatment

4 Closer

1 Fire stops 2 Partition closer 3 Angle closer 4 Plaste r stop

S5 Matching grain or colour


S6 Limits on plani ng margins on timber and if deviabon from stated size is not permitted S7 Method of join~ng or form 01 construction S8 Thickness or substance

5 Opening lights 6 Doors

1 Dimensioned description

nr

04 Opening lights include opening gear as appropriate

S9 Method affixing where not at the discretion of the Contractor SIO Bedding and jointing or poi nling compound S11 Fixing throug h vu Inerable materials

H14

Concrete rootlights/pavement lights


MEASUREMENT RULES DEFINITION RULES COVERAGE RULES

iii
SUPPLEMENTARY INFORMATION

INFORMATION PROVIDED

PI Information fs shown on location drawings under A PreliminariesIGeneral condibons


CLASSIFICATION
i Roo!lighls

TABLE i Dimenskmed description 1 Siles and extent 01 reinforcement stated

2 Pavemenllighls 3 Vertical units


4 Joints

2 Dimensioned description 1 Dimensioned descripbon


i Sizes of filling and

-------------~-~-

(nr)

m'
nr m

--

MI Isolated glass lenses are measured in Sec!ion E42

Ci Roof and pavement lights are deemed to include moulds, lormwork, reinforcement, bedding.and glass lenses

SI Kind and quality of materials 52 Bedding and fixing 53 Surface finishes

sealants staled

H20 H21 H92 K11 K12 K13 K14 K15

Rigid sheet cladding Timber weatherboarding Rainscreen cladding


Rigid sheet flooring/sheath ing/decking/sarki ng/I inings/casi ngs

Under purlin/inside rail panel linings Rigid sheet tine linings/panelling

Glassfi bre reinforced gypsum Ii nings/panell iog/casi ngs/mou Idings Vitreous enamel linings/panelling K20 Timber board floori ng/decking/sarking/I inings/casi ngs
INFORMATION PROVIDED PI Intormation is shown on location drawings under A Preliminaries/General COnditions MEASUREMENT RULES DEFINITION RULES COVERAGE RULES Cl The work is deemed to include: (a) labours, except as otherwise required (b) breather paper lining/sheathing (el angtes, except as otherwise required SUPPLEMENTARY INFORMATION

K21 Timber strip/board fine floodng/linings


Ml No deduction is made for voids s 0.50 ml M2 Work to ceilings and beams over 3.50 m above floor (measured to ceiling level in both cases), is so described stating the height in further 1.50 m stages

intemal unless described as external 02 All sizes are nominal sizes unless stated as finished sizes 03 TImber ~ems which do not have a constant crosssecton are so described and given stating the extreme dimensions

Dl The work is deemed

CLASSIFICATION TABLE
1 Walls 1 Width>

300 mm

Di me nsionec descripti 0 n

mt

1 La id di ago nally 2 Sloping

2 Floors

3 ~ilings
4 Roots 5 Tcps and cheeks 01 dormers

2 Width s 300 mm

3 Area s

i.co m

Dr -

M3 Width stages are measured the width 01 each : face

3 Cu rved, radii slated


4 Obstructed by in teg ral services

04 Walls include jambs and cills to openings and recesse s in walls and attached columns Ceilings include soffits 10 openings and recesses in walts, all faces 01 recesses in ceilings aM attached beams 05

51 Type, quality and thickness of materials a.M if limber whether sawn or wrOI S2 Method of joinling 01 form 01 construction where not at the discretion 01 the Contractor S3 Na1ure of background S4 Preservatve treatments appl ied as part 01 the production process

2,

irrespec1ive of width

Isolated beams

1 Total girth s 600 mm 2 and thereafter in 600 mm stages

mt

7 Isolated columns

M4 The girth is measured on the external fini shed face

D6 S lopi ng is defined as
sloping both > 10° from horizonta.1 and> 10°from vertical 07 Isolated beams and isolated columns inClude the faces 01 attached beams and attached colum ns which have a diftere nt finiSh from the adjoining face

55 Surtace treatments
applied as part of the production process

56

Fire retardant treatments

. 8 Abutments

1 Type stated

08 Abutments are defined as being where the detail is difterent tmrn the standard detail and (where appropriate) include around openings etc.

57 Oetails of cover and joi nting strips and cover mouldings


58 Selection and protection for subsequen t treatments S9 Constraints on width of board and planing margins and limitations if deviation from staled siz es is not permitted

9 Finished angl as

1 External

I-m

loternal

09 Finished angles are those where the decorative veneer or facing is returned or on panelling where angles are other than butt jointed 010 Holes are those for pipes, standards and the like

S10 Matching grain or


colour

10 Holes 11 Fire stops


1 Dimensioned description 1 Access panels 1 Di me nsioned description

I-or f-m nr

511 Fixing Ih roug h vu Inerabl e maleria Is


S12 Method of fixing whern not at the discretion of the Contractor S13 Details of finish, Iri m or support

12

Items extra over the work in which they occur

H30 H31 H32 H33 H41 H43

Fibre cement profiled sheet cladding/covering/siding Metal profiled sheet cladding/covering/siding Plastics profiled sheet cladding/covering/siding Bitumen and fibre profiled sheet cladding/covering Glassfibre reinforced plastics panel claddinglfeatures Metal panel cladding/features
MEASUREMENT RULES
conditions or on further drawings

INFORMATION PROVIDED
PI The tollowing information is shown either on location drawings under A Preliminaries/General which accompany the bills of quantities:
(a) the extent 01 !he work and its height above ground level

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION
SI Klnd, qUality and size 01 materials S2 Type and spacing 01 fixing

CLASSIFICATION TABLE
1 Roof coverings 2 Wall cladding 1 P~ch stated ml 1 Curved, radii stated 2 Fixed through underlinings Ml No deducbon is made for voids s 1,00 m2 Ct Coverings are deemed to include: (a) work in forming voids s 1 ,00 m2 other than holes (b) integral underlay

S3 Minimum side and end laps 54 Jointing or sealing

S5 Nature, thickness and spacing of structural supports

3 Abutments 4 Eaves 5 Verges 6 Ridges 7 Hips 8 Vert~1 angles 9 Valleys 1 0 Expa nsion ja; nts 11 Barge boards 12 Skirtings 13 Flashings 14 Aprons/sins 15 Gullers and linings 16 Jambs 17 Filler pieces

1 Dimensioned crosssection description

1 Raking 2 Curved, radii staled

M2 Boundary work to voids is only measured where the void is > 1,00 m1

C2 Boundary work is deemed to include bedding, pointi ng, ends, angles and intersections

18 Items extra over rool coverings 19 Ilems extra over wall cladding

1 Translucenl sheets 2 Sheets wrth soaker flanges 3 Rooflight units 4 Sheets w~h louvre blades

1 Dimensioned descripli(ln

nr

5 Ventilators 6 Junc~ons
20 Cutting 1 Raking 2 Curved
-

21 Holes

nr

Dl Holes are those for pipes, standards and lhe like

22 Fire stops 1 Dimensioned description

H51 H52

Natural stone slab cladding/features Cast stone slab cladding/features


PROVIDED MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION 51 Kind and Quality of materials 52 5ize, shape and thickness of unrts 53 Nature of base

INFORMATION

PI The following inlormation is shown either on loca~on drawings under A Preliminaries/General which accompany the bills of Quantities: (a) the scope and location of the work

conditions or on further drawings

Ml Work is measured on
the exposed face and no deduction is made lor voids s 0.50 m' M2 Work in staircase areas and plant rooms are each given separately M3 Work to ceilings and beams over 3.50 m above floor (measured to ceiling level in both cases), except in staircase areas, is so described stating the height in further 1.50 m stages

01 All work is deemed external unless described as internal 02 The thickness stated is the thickness exclusive 01 keys, grooves and the like 03 Rounded internal and external angles> 10 mm radius are classified as curved work where not measured under 15.1.*.0

Cl The work is deemed 10 include: (a) fair joints (b) working over and around obsmcnons (e) additional labour tor overhand work (d) wtting (e) drainage holes (II bedding mortars and adhesives (g) grouting (h) cleaning, sealing and polishing

54 Preparatory work
S5 Nature of finished surface including any sealing/polishing 56 Bedding or other method of fixing 57 Treatment of joints

CLASSIFICATION

TABLE

M4 Curved work is SO described wijh the radii stated measured on face 1 Plain, width > 300 mm 2 Plain, width s 300 mm 3 Work with joints laid oul to detail, widltl > 300 mm 4 Work wrth joi nts laid out to detail, width S" 300 mm i Dimensioned description

58 Layout of joints

1 Walts 2 Ceilings 3 Isolated beams 4 Isolated columns

r-m m2

ml

1 Patterned. details stated

M5 Width is the width of each face

D4 Beams and columns are classified as isolated where the work is different from the abuWng ceilings or walls
05 Work to sides and soffits of attached beams and openings and to sides 01 attached columns is classed as work to the abutting walls or ceilings

C2 Work to walls, ceilings, beams and columns is deemed 10 inctude internal and external angles and intersections!> 10 mm radius

r-m

5 Floors

I Level or to falls only s; 15° from horizontal 2 To falls and crossfalls and to slopes ~ 15° from horizontal 3 To slopes> 15° from horizontal

t Plain
2 Work with joints laid out to detail, dimensioned diagram staled

m1

I Paltemed work. details stated 2 Floors laid in bays, average size of bays stated 3 Inserts, size or section stated

06

Floors include landi ngs

C3 Work to !loors is deemed to include intersections in sloping work

6 Treads
I
I

t Width stated

7 Sills 8 Risers t Plain 2 Undercut 1 Height stated m

C4 Wolll. to treads, si lis and risers is deemed 10 include tair edges, internal and external angles C5 Curved treads, risers, strings and aprons are deemed to include curved and radiu.sed cuning tor speci al edge tiles C6 Strings and aprons are deemed 10 inClude lair edges, ends, angles and ramps

Strings

10 Aprons

11 Unings to channels

1 Horizontal
2 To tailS

1 Girth on face stated

I
I

C 7 Un ing.s to channels are deemed to include arrises, coves, ends, angles, intersections and outlets C8 Skirtings and kerbs are deemed 10 include fair edges, rounded edges, ends, angles and (amps

12 Skirtings 13 Kerbs

1 H eight slated

2 Heighl and width slated

~~~--------------

1 Patterned work, delails slated

2 Inserts, size or section


staled

3 Flush
4 Raking 5 Vertical 14 Corner pieces 15 Items e.xtra over the work in which Illey occur 1 Special units 2 Access units t Dimensioned description nr D7 Special units include non-standard units to prodoca fair edges, internal and external angles, moulded edges, beaded edges, and oovedjunctions

2 Manufacturer's

-~---------------

relerence

nr

3 Isolated special units 16 AcoesSl)ries


1 Separating membranes, thickness stated 2 Movement joints 1 Dimensioned description m'

3 Cover strips
4 Oivfding strips

D8 Movement joi nts include expansion joints

59

Method 1)1fi~ing

5 Ornaments, dimensioned
description and characte r stated

1 In situ 2 Precast

nr

1 Undercut

09 Ornaments are irregularly occurring leatures

6 Fixings, details stated

nr

H60 H61 H62 H63 H64 H65 H66

Plain roof tiling Fibre cement slating Natural slating Reconstructed stone slating/tiling Timber shingling Single lap roof tiling Bituminous felt shingling
MEASUREMENT RULES
conditions or on further drawings

1m

INFORMATION PROVIDED
PI The following information is shown either on location drawings under A Preiiminaries/General which accompany Ihe bills of quanti ties: (a) the extent of the rooting worn and its heighl above ground level

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION
SI Kind, quality and size of materials 52 Method of fixing

CLASSIFICATION TABLE
1 Roof coverings 2 Wall coverings 1 Pitch stated m1 1 Curved, radii stated Ml No deduclion is made Cl Cove rings are deemed to include: (a) underlay and battens (b) wolll in forming voids S3 Minimum laps 54 Spacing 01 battens and counter battens

for voids ~ 1.00 m2

s 1.00 m2 other
holes 3 Abutments 4 Eaves 5 Verges m 1 Raking 2 Cu rved, lad ii stated M2 Sou ndaly work 10 voids is only measured where the void is > 1.00 mt

than

C2 Bou nd ary work is deemed to include underctoaks, cutting, bedding. pointing. ends. angles and intersections

S5 Method of forming

6 Ridges 7 Hips 8 Vertical angles 9 Valleys 10 Fittings 1 Ventilators 2 Finials 3 Gas terminals 4 Hip irons 5 Soakers 6 Saddles 11 Holes 1 Dimensioned descronon or 1 Fixing on Iy

nr

Dl Holes are those for pipes, standards and the like

H70 H71 H72 H73 H74 H75 H76

Malleable metal sheet prebonded coverings/cladding

Lead sheet coverings/flashings


Aluminium strip/sheet coverings/flashings Copper strip/sheet coverings/flashings Zinc strip/sheet coverings/flashings Stainless steel strip/sheet coverings/flashings

Fibre bitumen thermoplastic sheet coverings/flashings


MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION
SIT ype and qu ality of
materials for backing, underlays, coverings, cladding and flashings

INFORMATlON PROVIDED
PI The following information is shown either on location drawings under A Pretiminaries/General
conditions or on further drawings which accompany the bitts of quantities: (a) the extent of the roofing work and its height above grouM level (b) the location and spacing of all laps, drips, welts, cross welts, beads, seams, rolls, upstands and downstands

52 Thickness, temper grade

weight and

S3 Method of fixing 54 Details of laps, drips, wells, beads, rolls, joints, upstands and downstands 55 Type of SUPllOrt

CLASSIFICATION TABLE
1 Roof coven ngs 1 Pitch stated m1 1 Curved, radii stated

materials S6 Special Iinishes

2 Wan coverings 3 Preformed cladding


panels 4 Dormers

Ml No deduction is made lor voids s; 1 00 m2


M2 The following allowances are made in calculating the area to be measured: (a) 180 mm for each drip < 50 mm high (b) 80 mm lor each well (e) 250 mm for each roll < 50 mm high (d) 100 mm for each seam (e) 500 mm for each lap (I) 500 mm for each upstandldownstand

5 Hoods 6 Domes 7 Spires 8 Finials 9 50Hits

Cl Coverings are deemed to include: (a) isolated areas (b) work to falls and crossfalis (c) underlay In contact with the covering (d) work in forming voids S; 1.00 m' other than holes (e) dressing/wedging into grooves, hollows, recesses and the like

H70/H71/H72/H73/H74/H751H76 continued CLASSIFICATION TABLE


10 Flashings 11 Aprons 12 Sills 13 Wealherings 14 Cappings 1 Dimensioned description 2 Dimensioned diagram m 1 Horizontal 2 Sloping 3 Vertical 4 Slepped 5 Prelormed 6 Dressi ng over corrugated roofing 7 Dressing over slating and liling 8 0 ressing over glass and glazing bars 1 Stepped 2 Secret 3 Sloping 4 Tapered 5 Preiormed 21 Catchpits 22 Sumps 23 Outlets 1 Dimensioned description nr

ED
MEASUREMENT RULES
M3 Boundary work to voids is only measured where the void is > 1.00 ml

DEFINITION RULES

COVERAGE RULES
C2 Work is deemed to include: (a) laps, seams, ends (b) angles and intersecnons (c) rolls (d) upslands and downslands (e) dressi nglwedgi ng inl0 grooves, hollows, recesses and the like

SUPPLEMENTARY INFORMATION

--------------~--

15 Hips
16 Kerbs 17 Ridges 18 Reveals, returns and jambs 19 Valleys 20 Gutters

24 Edges 1 Welted 2 Beaded 3 Shaped 25 Dressings 1 Corrugated roofing 2 Slati ng and ti Iiog 3 Glass and glazing bars 26 Saddles 27 Soakers and slates 28 Hatch covers 29 Ventilators 30 Collars around pipes, standards and the like 31 Holes 1 Size 01 member and length of collar Slated nr Dl Collars include pipe sleeves D2 Holes are those lor pipes, standards and the like 1 Dimensioned descriplion nr 1 Handed 10others IOf iixing C3 All dressing and bossing is deemed included 1 Nature 01 roofing m 1 Down co rrugations 2 Across corrugations m

32 Dots 33 Ornaments 34 Plugs

1 Details stated

J
J20 J21 J22 J30 J31 M11

Waterproofing
Mastic asphalt tanking/damp proofing

Mastic asphalt roofing/insulation/finishes Proprietary roof decking with asphalt finish


Liquid applied tanking/damp proofing

Liquid applied waterproof roof coatings


Mastic asphalt flooring/floor underlays
MEASUREMENT RULES
Ml Mastic asphalt flooring in staircase areas and plant areas and plant rooms are each given separately M2 Cu rved work is so described

INFORMATION PROViDED
P1 The following information is shown either 011 location drawings under A Preliminaries/General conditions or on further drawings which accompany the bilts 01 quantities: (a) plan of each level indicating the extent of the work and its height above ground level together with restrictions on the siting 01 plant and materials (b) section indicating the extent of tanking work

DEFINITION RULES
01 Mastic asphalt flooring is deemed internal unless described as external

COVERAGE RULES
Cl Work is deemed to include: (a) cutting to fine (b) cutting. notching. bending and extra material for lapping the unde~ay and reinforcement (c) working into recessed duct covers and the like. shaped insets. recessed manhole covers, mat sinkings, outlet pipes, dishing 10 gullies and the like (d) work to falls and crossfalls C2 Work is deemed 10 include: (a) working to meta.1or other flashings and working against !rames of manhole covers, ducl covers and the like (b) intersections on work 10 crossfalls C3 Work subsequenlly covered is deemed 10 inelude edges and arnses

SUPPLEMENTARY INFORMATION
SI Kind, quality and size of materials including underla.ys and reinforcement 52 Thickness and number of coats S3 Nature 01 base on which applied S4 Surface treatments SS Method of fixing decking 56 Spacing of structural supports

CLASSIFICATION TABLE
1 Tanking a~d damp proofing 2 Flooring and underl.ay 3 Roofing 4 Paving I Widlh $150 mm 2 Width 150 - 225 mm 3 Width 225 - 300 mm 4 Width> 300 mm I Pitch Slated m1 1 Work subsequently covered 2 Carried out in working space s 600 mm wide 3 Overhand work M3 The area measu red is Ihat in contact with the base and no deduction is made 101 voids s 1.00 m'

5 Skirtings 6 Fascias 7 Aprons

1 Girth"

150mm

1 Stepped 2 Raking

2 Girth 150 - 225 mm 3 Girth 225 - 300 mm 4 Girth> 300 mm girth slaled

M4 Girth is measured on face M5 Boundary work to voids is onty measu red where me void is> 1.00 m'

3 Raking in two planes

C4 Skirtlngs, fascias and aprons are deemed to include edses, drips, arrises, inlernal angle-fillets, dressi ng over tilting fillets, turning nibs into grooves, angles, Slopped ends requ iring angle IiIlets, Slopped ends, fair ends, and extra. materials for turning into grooves C5 Linings to glllters, channels and valleys and coven ngs 10 kerbs are deemed to include edges, arrises, ,internal angle-fillets, tilting fillets, lu rn ing nibs into grooves, ends, angles, inlersec1ions, outlets and extra malerial for turning into grooves

8 Unings to gutters 9 Linings 10 cIlannels 10 Linings to valleys 11 Coverings \0 kerbs

12 Internal angle fillets

1 Dimensioned descnplion

1 Coats (nr) where other than two

M6 12-17.*.0.* are only measured in association with work measured under 1-4.*.1.+
M7 Edges and arrises are only measured separatelv where the work is not subsequently covered

C6 Internal angle fillets are deemed to include ends and angles

13 Fair edges
14 Rounded ooges 15 Drips 16 Arrise.s 17 Turning asphalt nibs into grooves 18 Collars around pipes, standards and like members 1 Size of member and length 01 collar stated

f-nr

D2 Collars include pipe sleeves

C7 Collars around pipes, standards and the like are deemed 10 i nelude amses and internal angle Ii llets C8 linings to cesspools, sumps and the Iike are deemed to ineludearrises, internal angle-lillels and outlets

f--

19 linings to cesspools 20 Linings 10 sumps 21 Linings 10 manholes

1 Dimensioned description

nr

22 Edge trim

f-m

D3 Edge trim includes pre lormed angle trim

Cg Edge trim is deemed to inelude ends, angles and intersections

23 Rool ventilators

f-nr

J40 J41 J42 J43 J44


INFORMA

Flexible sheet tanking/damp proofing Built up felt roof coverings Single layer polymeric roof coverings Proprietary roof decking with felt finish Sheet linings for pools/lakes/waterways
nON PROVIDED MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION 51 Kind, quality and size of materials including undenays 52 Nature 01 base on which applied 53 Method 01 joi nling S4 Method 01 fixing deding S5 Spacing of structu fa I supports t Pitch stated ml 1 Curved radii stated M2 The area measured is that in contact with the base and no deduction is made for voids S; 1,00 m1 M3 Boundary work to voids is on Iy measured where the void is > 100 m2 C2 Bou nd ary work is deemed to include all cuHing, ends, angles, interseclions, notching, bending, turning into grooves, wedging, dressing, trimming and jointing covering to flashings, working into channels and the liKe and filler pi eces

PI The following information is shown either on location drawings under A Preliminaries/General conditions or on further drawings which accompany the bills of quanlities: (a) plan al each level indicating the extent of the work and its height above ground level together with restrictions on Ihe siting of plant and materials

MI Curved work is SO described with th e rad ii slated

Cl Work is deemed 1.0


include (a) cutti ng and lail edges (b) notching, bending and extra ma teriallor laps

CLASSIFICATION

TABLE

I Tanking and damp proofing 2 Roof coverings 3 Sliest linings 10 pools, lakes

or walerwaY$

4 Abutments 5 Eaves
I

1 Girth> 2.00 m 2 Girth S; 2.00 m in 200 mm stages

ml

1 RaKing 2 Stepped

6 Verges 7 Ridges 8 Hips 9 Venical angles 10 Valleys. 11 Skinings 12 FIashi nilS 13 Aprons 14 Gutters and linings I 5 Coveri ngs to ke rhs

18 Lin in gs to cess pool s 17 Lin ing s to s um ps 18 Collars around pipes, stands rd sa nd 1M B Iike 19 Outlets and dishing to gullies

1 Dimensioned description

nr

1 Size of pipe and length of collar stated I Dimensioned deseri pnon

01 Collars include pipe


sleeves

~
20 Edge trim m

02 Edge trim includes preformed angle trim

C3 Edge trim is deemed to include ends, angles and intersections

I--

21 Roof ventilators 22 Holes

or

~
or

2.3 Fire stops

~
1 Dimensioned description m

03 Holes are those for pipes, standards and the like

K Linings/Sheathing/Dry partitioning
K10 Plasterboard dry linings/partitions/ceilings
INFORMATION PROVIDED PI
The following inloffilation is shown either on location drawings under A Preliminaries/General conditions or on further drawings which accompany the bills 01 quantities: (a) the scope and location 01 the work (0) the servoes located within the ceiling or parti~on where the work includes comptex integral services

MEASUREMENT RULES
Work in staircase areas and plant foams are each 9 ivan separately

DEFINITION RULES
Dl Work is deemed internal unless described as external

COVERAGE RULES
Cl Work is deemed to include: (a) lair joints (b) working over and around obstructions into recesses and shaped inserts (c) additional labour lor overh and work (d) plaster lor dabs, filling and finishing (e) joint and reinforcing tape (I) bitumen impregnated pads C2 PaHerned work is deemed 10 include all extra wo rk involved

SUPPLEMENTARY tNFORMA TION


51 Kind, quality and thickness 01 sheeting and components

Ml

M2 Work to cei Iings and beams over 3.50 m above lloor (measured 10 ceiling level in bolh cases), except in stai rcase areas, is so described stali nJ;j the heig ht in further 1.50 m stages.
M3 Insulation. vapour barriers, fire barriers, isolating membranes. moisture resistant treatment and the like, are only measured in this section where they are an integ ra I part of a lining, or partition or cei lin g. or are fixe d theret.o

52
53

Meth ad 01 construction Layout and tre atm enl

01 joints
54 Complex inteJ;jral services

55 S6

Method of fixing

Thermal insulation and vapour barriers fix.ed with liniflJ;! 57 tnsulation to limit sound lransmissio n

58

Moisture resistant treatment a nd the like 59 5urf~ce applications forming part of dry lining finish 510 IsolaliflJ;! membranes

511 Method 01 jointing oompoSiI€ panels

CLASSIFICATION TABLE
I Proprietary partitions t Heighl in 300 mm stages an<! thickness of par1ibon stated I Walls I Boarded one side 2 Boarded bolh sides I Height in 300 mm stages staled I Total gir1h s 600 mm 2 and therealter in 60{1mm stages I Width 5: 300 mm 2 Width 300 - 600 mm m2 m m
1 Patterned, details stated

2 Cu rvad, radii slated 3 Obstructed by integral services

M4 The work is measured over obstructions M5 No allowance is made in measurement for lapped joints M6 The linear measurement 01 pamtians is the mean length of the par1ition M7 The linear measurement of linings is the length on

2 Linings

02 The height of framed work is th e height 01 the Irame and where the heig hts of the boarding dille r then this is so slated giving details 03 Reveals and soffits of openings and recesses in linings> 600 mm are defined as to wails, beams or columns 04 Linings are those which do no! lorm part of a proprietary system and exclude bmoor Irami ng

2 Beams, faces (nr) 3 Columns, laces (01)

4 Reveals and soffits 01 openil1lls and recesses 5 Ceilings

Iace
M8 No deduction is made 101 voids in par1itions and lin ings measu red Iinearly other than lor those voids which extend lull height, lull girth 01 lull width M9 No deduction is made for voids 5: 0.50 m2 in linings measured superficially

C3 Par1ltions and lini ngs are deemed to include the following where par1 of the proprietary system. Where not a pall ollhe proprietary system they are measured in accordance with the appropriate Work Seeton rules: (il) head and sole plates (b) studs, stillen ing sections, fiflings and channels (c) metal resilient bars (d) joi nling battens (e) insulation and barriers (f) lillets, banens and the like

Ml0 Where one face 01 a


double sided partition or a lace 01 lining is carried across the surface of an obstruction, the partition or lin ing is me asured overall and no ilem 01 abutments is measured

Mil

A recess is only measured where it is for part on Iy of the heig ht and nol where il is full heighl 3 Angles

to parutions

1 Plain 2 Irregular

1 Th ickness of partilio n
staled

4 Tee junclions 10 partitions 5 Ctosses to partilio ns

I Belween dillerenl fo rms of construction, linish details slated

6 Abutments

I Thickness of par1ition or lin ing slated 1 Intemal 2 External

7 Angles to linings

1 Belwee n dillerenl board


finishes, details stated

05 Abutments include Irimming to openings which extend full height, lull girth or full width unless linished with Ihe same finish as the faces. Trimming 10 openings which are not lull height. full girth or lull width are deemed to be included

C4 Angles, tee junctions, crosses and abutments are deemed 10 include lhe extra work involved, studding, grounds, angle tapes and the like
C5 Angles are deemed 10 include the exira work involved . .angle tapes and the like

S12 Delail 01 finish orlrim, grou nds or framing

r.P-I

1:8;1

K10 continued CLASSIFICATION TABLE


8 Fair ends to partitions
1 Thickness of partition

MEASUREMENT RULES
m M12 Fair ends are only measured where me exposed en<.! 1the part~ion 0 is finished wilh the same finish as the faces, or with a trim which is an integral part of the partition system

DEFINITION RULES
D6 Fair ends to partitions include trimming 10 openings

COVERAGE RULES
C6 Fair ends are deemed to include the extra work involved, studding, boarding, Ifims and the like

SUPPLEMENTARY INFORMATION
513 Details of finish or trim

stated

9 Beads, function stated

1 Oimensioned description

10 Fixings tor heavy fittings

1 Sinks 2 Radiators 3 Cupboards 4 Others, details stated

nr

07 The function of beads as angle beads, casing beads, trims and the like are stated

C7 Beads are deemed to indude working finishes thereto CB Fixings for heavy fittings are deemed to include additional supports and any cutting of boarding, trim or jointing 514 Type of additional supports

De Heavy fittings are those requiring additional support

11 Items extra over the

work in which they occur

1 Access panels

or

515 Type of panels

K30 Panel partitions


INFORMATION PROVIDED
PI The following information is shown either on location drawings under A Preliminaries/General
which accompany the bills of quantities: (a) the scope and location ot the work (b) the services located within the partition concmons or on further drawings

MEASUREMENT RULES

DEFINITION RULES
01 Work is deemed internal unless described as external

COVERAGE RULES

SUPPLEMENTARY INFORMATION

CLASSIFICATION TABLE
1 Partitions 1 Height and thickness of partition stated 1 FaClory applied finish 2 Site applied finish m m 1 Cu rved, radii stated 2 Obstructed by integral services Ml The work is measured over the obstructions M2 The linear measurement of partitions is the mean length of the partition M3 Factory applied finishes and site applied finishes are only measured where not at the discretion of the Contractor 02 Trims are separate items fixed on site as cover pieces to edges or panel joints 03 Openings is a general term for breaks in the general construction of partitions and includes the components filling the openings Cl Partitions are deemed to include all integral components, holes, etc preformed at factory but excluding trim SI Kind and quality of malerials 52 Method of construction

2 Trims

1 Dimensioned description

53 Layout of joints S4 Method of fixing S5 Compjex integral


services

3 Openings, exlta over the partitions in which they

1 Blanks 2 Doors 3 Windows 4 Glazed panels

1 Oi mensioned description

nr

occur

C2 Openings are deemed to inctude additional integral components C3 Openings are deemed to include ironmongery. glass. linings or the like but exclude trim

S6 Method of bedding, jointing or pointing S7 Details 01 ironmongery, glass, linings or the tike

Access panels

K32 Panel cubicles


INFORMATION PROVIDED
PI The following informallon IS shown either on local ion drawings uncer A Preliminaries/General which accompany the bills of quantities: (a) Ihe scope and loca Iion ollhe work conditions or on further drawings

MEASUREMENT RULES

DEFINITION RULES

COVERAGE RULES

SUPPLEMENTARY INFORMATION

CLASSIFICATION TABLE
1 Cubicle par1ilions; set 1 Dimensioned diagram nr Cubicle sets include doors, ironmongery or the like but exclude trims D2 Trims refer to separate items fixed on site at junclion of cubicles and al junctions with adjoining consnucnons

2 Trim

1 Dimensioned description

Cl Cubicle sets are deemed to include framing. stiffening, connecting and fixing devices supportings legs and brackets

Sl Kind and quality of materials


52 53 Method of construction Method of fixing

54 Method 01 bedding, jointing or pointing

K40 Demountable suspended ceilings


INFORMATION PROVIDED
PI The following information is shown either on location drawngs under A Preliminaries/General conditions or on further drawings which accompany the bi lis 01 quantities: (a) the scope and location of the work including integral fittings (b) the services located within the suspended ceiling void including arlY additional support for same

MEASUREMENT RULES
Ml Soffit linings on battens, etc. fixed direct to underside
of slab are measured elsewhere in ihs relevant Sections M2 Work in staircase areas an d plant rooms are each give n separately M3 Work to ceilings and beams over 3,50 m above floor (measured to ceiling level in both cases), except in staircase areas, is so described stating the height in lurther 1.50 m stages

DEFINITION RULES
01 All work is deemed internal unless described as external

COVERAGE RULES
CI Suspended ceilings etc, are deemed to include (a) worki ng over and around obstructions (b) support work and accessories '-or fittings (c) suspension and framed members C2 Patterned work is deemed to include all exira work involved C3 Work incorporating integral fittings is deemed to include addiUonal hangers, Iraming and the like

SUPPLEMENTARY INFORMATION
SI Kind and quality of materials S2 Size of panels and strips S3 Construenon of framing and suspension systems S4 Method of fixing S5 NaMe of backgrounds S6 Services in Ihe suspended ceiling void S7 Insulation materials

S8 Vapour barriers S9 Integral healing, vennlanon, lighting and fire prevention fittings

CLASSIFICATION TABLE
1 Ceilings 2 Beams 1 Depth 01 suspension s 150mm 2 Depth 01 suspension 150 -500 mm 3 and thereal1er in 500 mm stages 1 Thickness 01 lining and method 01 Ii xin g system 10 str ucture stated ml 1 Pat\ernec. details stated 2 Siopi ng Iinings, details stated M4 The area measured is that 0 n t he exposed lace and no deduction is made for voids s 0_50 m' M5 The depth of suspension is measured from the main structural sollil to the lining M6 Insulation and vapour barriers are measured in this Section where they are an integral part 01 the ceiling and are Iixed in the ceilin g M7 Isolated strips of ceilings are not measured separately between the boundary 01 the lining and the lirst line 01 integral fittings 02 Intagral Ii"ings oceu r where Ihe littings are designed and incorporated into 1he ceiling structure

3 Curved, radii stated


4 Suspension obstructed by services 5 Trims at regular Intervals within area of suspended ceiling, details stated

3 Isolated strips of suspended ceiling, thickness 01 lining stated

1 Width S; 30{) mm 2 and thereafter in 300 mm stages

03 Isolated strips of ceiling are those which are narrower than the specdied relevant lining unit dimension

4 nems exna over the lini og in which they occur

1 Access panels

1 Dimensioned description

nr

C4 Access panels are deemed to include edge trim and fixings

S10 Composi~on of panels and method 01 fixing

5 Upstands

1 Thickness 01 lining

1 Height'" 300 mm 2 and thereafter in 300 mm stages

S 11 Method 01 support and depth of suspension

K40 continued CLASSIFICATION TABLE


6 Irregular window and dormer cheeks 1 Dimensioned description nr

MEASUREMENT RULES

DEFINITION RULES

COVERAGE RULES
C5 Irregular window and dormer cheeks are deemed to include cutting and extra supports C6 Cavity fire barriers are deemed to include an scribing, angles, ends, and support work

SUPPLEMENTARY INFORMATION

7 Cavity fire barriers, lotal thickness staled

1 Plain 2 Obstructed by services

1 Height::; 300 mm 2 and thereafter in 300 mm stages 1 Dimensioned description

8 Edge mms

1 Plain

2 Floating
9 Angle trims

M8 Trims at regular inte!Vals within the area of suspended ceiling are included within the item description of same

D4 Plain edge trims are those which are fixed to the structure D5 Floating edge trims are those which are fixed to the ceiling system

C7 Trims are deemed to include mrtred. regular and irreg ular angles

S12 Centres of fixing

1-3.*.*.5
M9 Trims are measured to openings formed for fittings

10 Items extra over the


trims in which they occur

1 Irregular angle pieces

or

06 Irreg ular ang Ie pieces are purpose made manufactured corner pieces Ml0 Collars are measured where they are integral with fire barriers 1 Support to light fittings or the like S13 Types

11 Collars to se!Vices passing through fire barriers 12 Bridging

1 Pipes 2 Trunking 1 Span stated

1 length at sleeve each side of barrier stated

or

MIt Bridging is measured where widths of trunking in the ceiling space obstruct the standard grid

CB Bridging is deemed to include additional fixings

13 Fillings

1 Dimensioned description

m nr

K41

Raised access floors


MEASUREMENT RULES
conditions or on further drawings

INFORMATION PROVIDED
PI The following information is shown either on location drawings under A Preliminaries/General which accompany the bills of quantities: (a) the scope and location of the work

DEFINITION RULES

COVERAGE RULES
Cl Raised access floors
are deemed to include (a) panels. supporting structures. adhesives, bearing pads and the like (b) cuffing and notching and extra supports

SUPPLEMENTARY INFORMATION
SI Kind and quality of materials S2 S3 Supporti ng system s Frames to panels

CLASSIFICATION TABLE
1 Floors 1 Thickness of panel stated 1 Height 01 cavity stated m' 1 Patterned. details stated Ml No deduction is made for voids $; 0.50 m' M2 The height stated for ramps is the height at each end

54 Method of Iixi ng

2 Ramps 1 Thickness, length and width stated

nr

3 Items extra over the floors in which they occur 4 Ski rtings and perimeter edge trims

1 Special panels

1 Oimensioned description

nr

1 Dimensioned description

M3 Skirtings and perimeter edge frims not executed as part 01 the access floor are measured in Section P20

C 2 Skirtings and perimeter edge trims are deemed to include ends and angles

L Windows/Doors/Stairs
L10 Windows/Rooflights/Screens/Louvres
INFORMATION PROVIDED
PI Information is shown on location drawings under A PreliminaniesiGeneral conditions

MEASUREMENT RULES

DEFINITION RULES
01 All sizes of timber are nominal sizes unless stated as finished sizes

COVERAGE RULES

SUPPLEMENTARY INFORMATION

CLASSIFICATION TABLE
1 Windows and window frames 2 Window shulters 3 Sun shields 4 Rooflights, skylights, rool windows and frames 5 Screens, borrowed lights and frames 6 Shopfronls 7 Louvres and Irames 1 Dimensioned diagram

nr

M 1 Standa rd sections are identified

Cl The work is deemed to include notching around obstructions

SI Kind and quality of materiafs and if timber whether sawn or wrot

C2 Items include: (a) doors wh ere suppl ied with the unit (b) architraves, trims, sills, sublrames, and the like where part of the component (c) ironmongery where suppl ied with th e component (d) finishes where part of the component as delivered (e) glazing wh ere suppl ied with the component (t) mechanical operation and automatic operating equipment where supplied with the component (g) lixings and fastenings
m

S2 Preservatives treatment applied as pall of the production process


S3 Surface treatments applied as part of the production process S4 Selection and protection lor subsequent treatment S5 Match ing grain or colou r S6 Limifs on planing margins on timber and if deviation Irom stated size is not perrnitted S7 Method of jointing or form of construction S8 Method of fixing where not at the discretion of the Contractor S9 Fix ing th rough vulnerable materials S10 Bedding, jointing and pointing compound

8 Bedding frames 9 Pointing frames 10 Bedding and pointi ng frames

L20 Doors/Shutters/Hatches
INFORMATION PROVIDED MEASUREMENT RULES DEFINITION RULES COVERAGE RULES SUPPLEMENTARY INFORMATION

P1

Information is shown on location drawings l'nder A Preliminaries/General TABLE

conditions

CLASSIFICATION

01 All sizes of timber are nomina I sizes unless stated as finished sizes

1 Doors 2 Rolling shutters and collapsible gates 3 Slidinglfoiding 4 Hatches 5 Strong room doors 6 Grilles partitions

1 Dimensioned

diagram

nr

1 Approximate

weight

stated

MI Standard sections are identified M2 Each leaf of a multileafed door is counted as one door M3 Approximate weight is only stated for metal doors and inc ludes thei r associ ated frames M4 Doors where supplied with their associated Irarnes or linings are measured as composite items under General nute 9_1

Cl Doors are deemed to include fitting and hanging C2 The work is dee med to include notching around obstructions C3 Items include: (a) doors where supplied with the unit (b) architraves, trims and the like where part of the component Ie) ironmongery where supplied with the component (d) linishes where part of the com ponen 1as delivered (e) glazing where suppl ied with the component (tl mechanical operation and autom atie operating equipment where supplied wi Ih Ihe component (9) fixings and fastenings

SI Kind and quality of materials and if timber whether sawn or wrot S2 Preservatives treatment applied as part of the prod uclion process S3 Surface treatments applied as part ollhe production process S4 Selection and protec1ion for subsequent treatment S5 Matching grain or colour

7 Door frames and door lin ings, sets (nr)

1 Jambs 2 Heads 3 Sills (01) 4 Mullions (nr) 5 Transoms (nr)

1 Dimensioned overall cross- section descri ption

1 Repeats 01 ide ntical sets (nr) 2 DiHerent cross-secfion shapes (nr) 3 Stopped labours (nrl

M5 Enumerated composite door frame and lining sets need not state the nu mber of sets within the description

S6 Limits on planing margins on timber and if deviation Irom stated size is not permitted S7 Method of jointing or form of construction S8 Method 01 fixing where not at the discretion of the Contractor S9 Fix ing through vu Inerable materials S10 Beddi n9, lointing and poi nling eom pound

----------------6 Composite sets 8 Bedding frames 9 Pointing frames t 0 Bedding and poi nting frames 1 Dimensioned description nr m

L30 Stairs!Walkways/Balustrades 041 8a rri ers/G uardra iIs


INFORMATION PROVIDED
PI Information is shown on location drawings under A Preliminaries/General conditions


MEASUREMENT RULES DEFINITION RULES
01 Work in this Section covers: (a) staircases, ladders and loft ladders (b) landings, catwalks and access walkways (c) ba.lustrades and handrails (d) hatch doors where part 01 a loft ladder component or
Ml Where accessories such as linings, Uim nosings, ironmongery etc. are not included in a catalogue relerence they are measured in Ihe appropriate Work Sections M2 Isolated handrails are measured in Section P20 Cl Composhe items are deemed to include: (a) linings, nosings, cover moulds, trims and the like where part 01 the oomponent (b) soffit lining, spandrel panels and the like where part of the component (c) ironmongery and operating gear to loft ladders where supplied with the component (d) fi nishes where pari 01 the componenl as delivered (e) fixings, fastenings, blockings, wedges, bolts, brackets, cleats and the like C2 Staircases are deemed to include newels SI Kind and quality 01 materials and if timber whether sawn or wrol S2 Preservative treatments

COVERAGE RULES

SUPPLEMENTARY INFORMATION

CLASSIFICATION TABLE
1 Composite i1em, type stated t Dimensioned description

2 Component drawing

-----------------

applied as part of the


production process

S3 Sur1ace treatments applied as part of the production process


54 Selection and protection for subsequent treatment
S5 Matching grain or colour S6 Lim~s on planjng margins on timber and if devia~on from stated size is not permitted

2 Isolated balustrades

1 Cu rved, radii stated

3 Associated handrai Is
4 Extra over the isolated balustrades or associated handrails in which they occ,,!r 1 Ramps 2 Wreaths 3 Bends 4 Ornamental ends or

02 Isolated balustrades are those which do not form an integral part at a staircase unit
03 Associated handrails are handraits 01 a material different from the balustrade with which th ey are associated

C3 Plain ends are deemed to be included

S7 Method of jointing or form of construction

S8 Method of flxing where not at the discretion 01 the


Contractor S9 Fixing through vulnerable materials

5 Opening portions, details stated

S-ar putea să vă placă și