Documente Academic
Documente Profesional
Documente Cultură
1
System pro M
For domestic business, the Standard Terms for Delivery of Products and Services of the Electrical
Industry (ABB Form 2292) shall apply in connection with the Standard Sales Terms (ABB Form 2327) in
their then applicable version. For foreign business, the Standard Terms for Delivery of Products and
Services of the Electrical Industry (ABB Form 2293 German-English, or ABB Form 2294 German- French)
shall apply in connection with the Standard Sales Terms (ABB-Form 2381 English) in their then applicable
version.
Warranty
We assume warranty in accordance with the Standard Sales and Delivery Terms. Complaints shall be
made in writing within eight days following receipt of the goods.
Technical information and illustrations are not binding and subject to change without notice.
2
Selction table
System pro M Modular installation equipment
Contents page
3
Minature circuit breaker
System pro M S-2
4
Minature circuit breakers
System pro M UL and CSA approvals for the equipment of
commercially used machinery
Contents page
As a rule, back-up fuses are required as
additional protection.
Please contact the importer/inspector for
more detailed information.
5
MCBs, S 260-B series
System pro M UL 1077, File No. E 76126
CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
S 260-B No. of
poles
rated
current
In A
order details
480 V
60 V ... 63 S 261-B 63 GH S261 0001 R0635 34370 6
6 S 262-B 6 GH S262 0001 R0065 35060 5 0.250 5/20
2 10 S 262-B 10 GH S262 0001 R0105 35100 8
13 S 262-B 13 GH S262 0001 R0135 35120 6
6
MCBs, S 260-B series
System pro M UL 1077, File No. E 76126
CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
S 260-B No. of
poles
rated
current
In A
order details
1 6
10
S 261-B 6 NA
S 261-B 10 NA
GH S261 0103 R0065
GH S261 0103 R0105
34660 8
34680 6
0.250 50/40
3 6
10
S 263-B 6 NA
S 263-B 10 NA
GH S263 0103 R0065
GH S263 0103 R0105
36130 4
36150 2
0.500 2/20
7
MCBs, S 260-C series
System pro M UL 1077, File No. E 76126
CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
S 260-C No. of
poles
rated
current
In A
order details
8
MCBs, S 260-C series
System pro M UL 1077, File No. E 76126
CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
S 260-C No. of
poles
rated
current
In A
order details
1 0.5
1
S 261-C 0,5 NA
S 261-C 1 NA
GH S261 0103 R0984
GH S261 0103 R0014
66080 3
66090 2
0.250 5
9
MCBs, S 270-K series
System pro M UL 1077, File No. E 76126
CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
S 270-K No. of
poles
rated
current
In A
order details
10
MCBs, S 270-K series
System pro M UL 1077, File No. E 76126
CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
S 270-K No. of
poles
rated
current
In A
order details
Selection table
S 270-KS No. of
poles
rated
current
In A
order details
11
MCBs, S 270-Z series
System pro M UL 1077, File No. E 76126
CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
S 270-Z No. of
poles
rated
current
In A
order details
12
MCBs, S 280-K series
System pro M UL 1077, File No. E 76126
CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
S 280-K No. of
poles
rated
current
In A
order details
13
MCBs, S 280-K series
System pro M UL 1077, File No. E 76126
CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
S 280-K No. of
poles
rated
current
In A
order details
NA 0.75
1
S 283-K 0,75 NA
S 283-K 1 NA
GH S283 0103 R0187
GH S283 0103 R0217
47150 8
47170 6
1.6 S 283-K 1,6 NA GH S283 0103 R0257 47200 0
14
MCBs, S 280-Z series
System pro M UL 1077, File No. E 76126
CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
S 280-Z No. of
poles
rated
current
In A
order details
3 0.5
1
S 283-Z 0,5
S 283-Z 1
GH S283 0001 R0158
GH S283 0001 R0218
46060 1
46150 9
0.390 3/12
15
MCBs, S 280-Z series
System pro M UL 1077, File No. E 76126
CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
S 280-Z No. of
poles
rated
current
In A
order details
1 0.5
1
S 281-Z 0,5 NA
S 281-Z 1 NA
GH S281 0103 R0158
GH S281 0103 R0218
44230 0
44280 5
0.260 5
16
MCBs, S 280 UC-K series
System pro M for AC and DC currents
UL 1077, File No. E 76126 CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
S 280 UC-K No. of
poles
rated
current
order details bbn
40 12233
price
1 piece
price
group
weight
1 pc.
pack.
unit
according to IEC 947-2 In A order code order code EAN DM kg pc.
0.2 S 281 UC-K 0,2 GH S281 0164 R0087 63420 0 0.130 10/40
1 0.3 S 281 UC-K 0,3 GH S281 0164 R0117 63430 9
0.5 S 281 UC-K 0,5 GH S281 0164 R0157 63440 8
0.75 S 281 UC-K 0,75 GH S281 0164 R0187 63550 4
1 S 281 UC-K 1 GH S281 0164 R0217 63460 6
1.6 S 281 UC-K 1,6 GH S281 0164 R0257 63470 5
2 S 281 UC-K 2 GH S281 0164 R0277 63480 4
3 S 281 UC-K 3 GH S281 0164 R0317 63490 3
4 S 281 UC-K 4 GH S281 0164 R0337 63500 9
6 S 281 UC-K 6 GH S281 0164 R0377 63520 7
8 S 281 UC-K 8 GH S281 0164 R0407 63510 8
SK 0323 B 91
2 0.2
0.3
S 282 UC-K 0,2
S 282 UC-K 0,3
GH S282 0164 R0087
GH S282 0164 R0117
63620 4
63630 3
0.260 5/20
17
MCBs, S 280 UC-K series
System pro M for AC and DC currents
UL 1077, File No. E 76126 CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
4 0.2
0.3
S 284 UC-K 0,2
S 284 UC-K 0,3
GH S284 0164 R0087
GH S284 0164 R0117
74160 1
74170 0
0.520 2
18
MCBs, S 280 UC-Z series
System pro M for AC and DC currents
UL 1077, File No. E 76126 CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
19
Accessories
System pro M for MCBs of series S 260, S 270 and S 280
and RCBO „multiSTOTZ“ F 270/6 series
Selection table
Auxiliary switch
1 NO + 1 NC S 2-H 11 GH S270 1916 R0001 61500 1 0.04 1
2 NO S 2-H 20 GH S270 1916 R0002 61510 0 0.04 1
2 NC S 2-H 02 GH S270 1916 R0003 61520 9 0.04 1
S 2-H11
Auxiliary switch
2 NO + 1 NC S 2-H 21 GH S270 1936 R0001 01370 3 0.05 1
1 NO + 2 NC S 2-H 12 GH S270 1936 R0002 01380 2 0.05 1
3 NO S 2-H 30 GH S270 1936 R0003 01390 1 0.05 1
3 NC S 2-H 03 GH S270 1936 R0004 01400 7 0.05 1
S 2-H 11 X
Signalling contact
screw-in S 2-S GH S280 1902 R0008 42920 2 0.05 1
Undervoltage release
12 V DC S 2-UA 12 GH S280 1911 R0001 42970 7 0.09 1
SK 0330 B 91
S 2-A ...
Shunt release
12 ... 60 V AC/DC S 2-A 1 GH S280 1909 R0001 42930 1 0.145 1
100 ... 415 V AC S 2-A 2 GH S280 1909 R0002 42940 0 0.145 1
and
110 ... 250 V AC/DC
20
Industrial MCBs
System pro M S 220-K series
UL 1077, File No. E 76126 CSA C22.2 No. 235, Report No. LR 98793-9
Selection table
S 220-K No. of
poles
rated
current
In A
order details
1 0.2
0.3
S 221-K 0,2
S 221-K 0,3
GH S221 0001 R0087
GH S221 0001 R0117
31610 6
31620 5
0.18 10/40
21
Rated switching capacity
System
series
pro M alternating current direct current direct current
trip characteristics single-phase 2/3 phase single-pole single-pole 2-pole
rated current 277 V 347 V 277 V 347 V 60 V ... 250 V ... 500 V ...
277/480 V 347/600 V
A kA/cos ϕ kA/cos ϕ kA/cos ϕ kA/cos ϕ kA/T ms kA/T = 15 ms
S 260-B 6
10 ... 20
6/0.5 6/0.5
25 ... 32 10/4.0
40
50 ... 63 5/0.5 5/0.5
S 260-C 0.5 ... 2
3 ... 4
6
8 ... 13 6/0.5 6/0.5 10/4.0
16 ... 20
25 ... 32
40
50 ... 63 5/0.5 5/0.5
S 270-K 0.5 ... 2
3
4
6 ... 10 6/0.5 6/0.5 10/4.0
16 ... 20
25 ... 32
40
50 ... 63 5/0.5 5/0.5
S 270-Z 0,5 ... 2
3 ... 4
6
8 6/0.5 6/0.5 10/4.0
10 ... 16
20 ... 32
40
5/0.5 5/0.5
50 ... 63
S 280-K 0.2 ... 2
3, 4
10/4.0
6, 8
10/0.5 10/0.5
10, 13
16 ... 25 15/4.0
32 ... 40
50 ... 63 6/0,5 6/0,5 10/4.0
S 280-Z 0,5 ... 2
3, 4
10/4.0
6, 8
10/0.5 10/0.5
10, 13
16 ... 25
15/4.0
32 ... 40
50 ... 63 6/0.5 6/0.5 10/4.0
S 280 UC-K,Z 0.2/0.5 ... 2
3
4 10/4.0
6 10/0.25 10/0.25 4.5 4.5
8
10 ... 20 15/4.0
25 15/4.0
50, 63 6/0.25 6/0.25 10/4.0 4.5 4.5
S 220-K 0,2 ... 1
1,6, 2
3, 4
3/0.75 3/0.75
6, 8
10 ... 32
40 ... 63
Two-pole MCBs (if two poles are connected in series) can be used up to 110 V DC in dc systems balanced to earth.
Polarity is not relevant for direction of connection.
Back-up protection is only necessary if the solid short-circuit current expected may exceed the indicated switching capacity.
The rated current of the fuse for back-up protection is: 15 A to I n = 4 A and 4 x I n at In = 6 A.
22
Residual-current protective devices
System pro M UL approvals for the equipment of
commercially used machinery
Contents page
Accessories .............................................................................................. 28
23
Residual-current-operated circuit-breaker
System pro M (RCCB) F 370 series
UL 1077, File No. E 174118
Selection table
rated rated order details bbn price price weight pack.
residual current 40 12233 1 pc. group 1 pc. unit
current In
I왕n mA A type code order code EAN DM kg pc.
F 370 series
RCCB F 372, 2-pole, 277 V AC, 60 Hz
10 16 F 372-16/0,01 GH F372 0001 R1460 02680 7 0.345 5
SK 0041 B 96
teristic In
A type code order code EAN DM kg pc.
S 2-H11
24
Busbars
System pro M
Contents page
Shock-protected busbars
Universal terminals
for MCBs with combined box terminals..................................................... 26
25
System pro M Busbar systems
SK 0061 Z 91
for MCBs
with combined box terminals
cross length No. order details bbn Cu price price weight pack.
SZ-KS 2/12 section of 40 12233 No. 1 pc. group 1 pc. unit
single-pole with 1 phase mm2 mm poles type code order code EAN DM kg pc.
feeder: 1 phase
12 207 12 x 1 SZ-KS 1/12* GJ I232 2322 R0001 59790 1 0.023 0.015 100
12 988 56 x 1 SZ-KS 1/56* GJ I232 2322 R0002 59800 7 0.110 0.073 50
SZ-PSB 3 N, SZ-PSB 4 N
SZ-PSB 11 N, SZ-PSB 12 N 24 207 12 x 1 SZ-KS 2/12* GJ I232 2322 R0003 59810 6 0.046 0.031 100
single-pole or 3-pole with 3 phases 24 988 56 x 1 SZ-KS 2/56* GJ I232 2322 R0004 59820 5 0.220 0.138 50
36 988 56 x 1 SZ-VB 45.32* GJ I232 2148 R0001 59720 8 0.330 0.233 50
16 202 12 x 1 SZ-KS 18/12 N GH V036 0875 R0041 74530 2 0.071 0.073 50
16 1007 56 x 1 SZ-KS 18/56 N GH V036 0875 R0042 74520 3 0.320 0.300 50
* without insulation
SK 0095 Z 96
Busbar block
for MCBs: single-pole or 3-pole
feeder: 3 phases
SZ-KS 3/39 N
SZ-KS 4/39 N
single-pole + aux.switch with 1 phase 10 213 4 x 3 SZ-PSB 3 N GH L520 1915 R0005 29400 3 0.085 0.082 30
10 1058 20 x 3 SZ-PSB 4 N GH L520 1915 R0006 29410 2 0.505 0.468 10
SZ-PSB 130 N
4-pole + aux.switch w. 3 phases + N
16 1020 13 x 4 SZ-PSB 130 N GH V036 0503 R0040 40330 6 1.32 0.810 10
bbn-Nr. 40 16779
26
System pro M Busbar systems
SK 0074 Z 91
with combined box terminals
SK 0098 Z 96
(no connection terminals required)
SZ-PSB 53 N, SZ-PSB 54 N
SZ-PSB 55 N, SZ-PSB 56 N cross length No. order details bbn Cu price price weight pack.
single-pole + NA or section of 40 12233 No. 1 pc. group 1 pc. unit
2-pole with 2 phases or mm2 mm poles type code order code EAN DM kg pc.
1 phase + N
3-pole + NA or 4-pole
SK 0101 Z 96
end caps:
3 phases + N PSB-END 4
27
System pro M Busbar systems
SK 0075 Z 91
with box terminals
cross length No. order details bbn Cu price price weight pack.
section of 40 12233 No. 1 pc. group 1 pc. unit
SZ-KS 16/12 N (NB) mm2 mm poles type code order code EAN DM kg pc.
SZ-KS 16/56 N (NB)
single-pole with 1 phase
for MCBs: single-pole
feeder: 1 phase
16 202 12 x 1 SZ-KS 16/12 NB GH V036 0875 R0035 55550 5 0.075 0.042 30
16 1007 56 x 1 SZ-KS 16/56 NB GH V036 0875 R0036 55560 4 0.280 0.250 10
SK 0258 Z 98
16 230 12 x 1 SZ-KS 16/12 NB* GH V036 0503 R0025 15880 0 0.075 0.042 30
16 1044 56 x 1 SZ-KS 16/56 NB* GH V036 0503 R0026 27910 9 0.280 0.250 10
* blue insulation
SZ-KS 13/39 N
single-pole + aux. sw. 1 phase
single-pole with auxiliary switch
1 phase
16 1012 39 x 1 SZ-KS 13/39 N GH V036 0875 R0030 55540 6 0.251 0.157 10
single-pole or 3-pole
SK 0093 Z 97
end caps:
3 phases PSB-END 3
single-pole or 3-pole
3 phases
SZ-PSB 53 UL
single-pole+ NA or 10 214 4 x 3 SZ-PSB 3 UL GH V036 0503 R0017 28970 2 0.15 0.114 30
2-pole with 2 phases bbn-Nr. 40 16779
must not be cut to length
for combined
residual-current devices: types F 374, F 674 (80 and 100 A), 4-pole +
SK 0050 Z 98
for combined
people protector: type P 271 and multiSTOTZ type F 271
feeder 1 phase + N
SK 0121 Z 96
28
Modular installation equipment
System pro M
Contents page
29
Switches 16 and 25 A, E 220 series DIN EN 60669-1, VDE 0632 Part 1
Selection table
style rated power order details bbn price price weight pack.
voltage loss 40 12233 1 pc. group 1 pc. unit
V W type code order code EAN DM kg pc.
Control switch
rated current = 16 A
rated current = 25 A
SK 0242 B 91
One-way switch
rated current = 16 A
rated current = 25 A
rated current = 25 A
Two-way switch
rated current = 16 A
1 change-
over
contact 250 0.48 E 221-6 GH E221 1001 R0008 00290 0 0.060 10
2 change-
over
contact 250 0.96 E 221-6/2 GH E221 1001 R0009 00300 6 0.070 10
rated current = 25 A
1 change-
over
contact 250 1.13 E 222-6 GH E222 1001 R0008 00410 2 0.060 10
Two-way switches with two off positions (I-O-II, manual - OFF - automatic)
rated current = 16 A
rated current = 25 A
30
Pushbuttons and indicator lights DIN EN 60669-1, VDE 0632 Part 1
Selection table
rated current for pushbuttons and indicator lights = 16 A, rated voltage = 250 V
Pushbutton 1 NO + 1 NC
Illuminated pushbuttons 1 NO, without collar with holder E 10 for pilot lamp 2 W max.
Indicator light without collar with holder E 10 for pilot lamp 2 W max.
31
DIN EN 60 669-1,
System pro M Alarm indicator VDE 0632 Part 1
Equipment for panel installation on DIN rails (35 mm) according to DIN EN 50 022
mounting depth: 68 mm
mounting width: 17.5 mm = 1 module
colour: grey, RAL 7035
Application
The alarm indicator transmits optical and acoustic signals. Malfunctioning is indicated by a flashing and short beeping signal.
After the indication is detected, press the acknowledgment switch or an external pushbutton to turn off the acoustic signal,
the optical signal will then turn into a steady light.
The device is actuated by external contacts of alarm, malfunctioning or warning indicators and via limit switches or auxiliary
switches.
SK 0124 B 99
Technical data
rated voltage: 230 V 50 Hz power loss: 4W
(120 V 60 Hz)
cycle time: ON 1s 10% operating frequency: typ. 3.3 kHz
OFF 1s 10%
E 228-WM
sound level: typ. 60 dB ambient temperature: – 20 °C/- 4°F to + 50 °C/122°F
ON duration: 100% connection cross section:
up tp 1 x 6 mm² or 2 x 2.5 mm² massive,
up to 2 x 1.5 mm² flexible with connector sleeve
or pin-end connector.
Selection table
3
SK 0171 Z 91
2a
SK 0133 Z 93
32
System pro M Elapsed-time meter
UL 508; File No. E 171252
Equipment for panel installation on DIN rails (35 mm) according to DIN EN 50 022
mounting depth: 68 mm
mounting width: 17.5 mm = 1 module
colour: grey, RAL 7035
Application
lapsed-time meters are used to record operating times as well as to determine idle times and off times of commercial, industrial
and household plant and equipment.
Technical data
SK 0120 B 99
AC equipment
rated voltage: 60 Hz: AC 24 V, 120 V, 240 V
voltage tolerance: + 6% – 10%
power consumption: 1,5 VA
E 233
ambient temperature: – 15 °C/+5°F ... + 50 °C/122°F
counting capacity: 100 000 h
reading accuracy: 0.01 h
operation display: fast running
connection cross section: up to 10 mm²
Selection table
elapsed-time meter
SK 0203 Z 91 SK 0011 Z 96
33
Timer
System pro M programmable time switches with
microprocessor-controlled electronics ML File No. E 196127 (WGZR)
contact memory power order details bbn price price weight pack.
comple- locations loss 40 16779 1 pc. group 1 pc. unit
ment W type code order code EAN DM kg pc.
SK 0185 Z 98
2 channel one day / one week time switch with 24 h/7 d programme
36 memory locations freely assignable to channel 1 or 2. Individualised blocks.
Voltage drop :
34
MCBs with UL/CSA approval for the protection of lines and
appliances
System pro and
M where they are used
35
ABB STOTZ-KONTAKT, the Heidelberg-based company, The new plug-in connection technology for the devices and
develops, manufactures and sells highly modern, modular apparatus rack ensures quick and reliable installations: as-
systems for electrical building installations. sembly, connection of the devices and cross wiring are car-
It offers complete installation ranges for a wide variety of ried out time-effectively in one single step.
System pro M
applications: If need be, component sets may still be changed quickly and
flexibly right until transfer takes place; devices may also be
exchanged easily at some later date, and economically in
System pro M terms of both money and time, at that.
The entire System Connect was developed by ABB STOTZ-
For classic installation applications KONTAKT and Striebel & John, within the framework of their
The modular System pro M for installation on DIN rails in- successful system partnership.
corporates Europe’s best-selling miniature circuit-breakers
and residual-current-operated circuit-breakers as well as a
complete range of built-in devices. EIB Installation Systems
The system components have been designed with various
functions and performance capabilities and are therefore to For intelligent Building Installation
able optimally cover the complete range of applications in Highly modern, programmable installation systems with bus
building installation: technology based on the European EIB standard.
쎲 conventional domestic electrical installations
쎲 industrial and commercial installations ABB i-bus EIB
쎲 protection and switch functions System with special 2-core bus cable, primarily for new
쎲 checking and monitoring tasks buildings.
쎲 control and time-dependent tasks etc.
ABB Powernet EIB
System pro M compact System for retrofitting in existing buildings. Transfer of
information via the existing network.
The extension of System pro M for targeted use in domestic
electrical installations stands out due to its compact and Security Systems
easily comprehensible range of miniature circuit-breakers,
residual-current-operated circuit-breakers and cross wiring
tools as well as an optimised installation technology taking All-in-one Protection
into account the special circumstances and requirements of Wide range of security systems and components: intruder
domestic electrical installations. and fire alarm systems, radio-controlled alarm systems, door
locking system and signalling components.
36