CONTENTS
1. ACE III Design & Structure

2. ACE III Room Thermostat

3. ACE III Features & Strong Points

4. Comparison of GOM+ & ACE III

5. ACE III Sales Points


3
1. ACE III Design & Structure
Air Inlet Flue Exhaust

Heating Air Vent


Main Heat Exchanger (STS)

Flow S/W
Combustion Chamber
Expansion Tank

Burner Assembly

APS (Air Pressure Sensor)


Pressure Gauge Fan Assembly

Domestic Heat Exchanger


Controller, PCB
Circulation Pump
(Canned Type) Modulating Gas Control V/V
3-Way V/V Domestic Water Flow S/W

Heating Supply
Gas Inlet
Heating Strainer Tap water Inlet
Heating Return (include Sediment Filter)
Pressure Relief V/V D.H.W. Outlet

ACE III Design ACE III Inner Structure


4
2. ACE III Room Thermostat

■ ■

A/S Running

Heating Control
D.H.W Heating

■ Select a Heating
H W
M R ■
Control Type
L T ■ Water Temp. / Room Temp.

D.H.W Only / Timer

H : 70°C / M : 60°C / L : 50°C


W : 40~80°C / R : 10~40°C / T : 0~12H
Quick D.H.W Power

Quick D.H.W


■ Quick D.H.W Function

■ ■
■ Automatically be released
after 10 minutes if not using
5
3. ACE III Features & Strong Points (1)
 Stainless Steel Heat Exchanger
- Durable and Clean
- Possible to run a mid-water temp.
(30~50℃) operation without any
corrosion.
- Long Life and High Efficiency

• Mid-Water Temperature Operation

Mid-water temperature (30~50℃) heating give a lower heat loss in the distribution system,
lower standby losses of the boiler, and a higher efficiency. (especially better result under well isolated
heating circumstance) But there will be condensing water and corrosion on the heat exchanger.

 SMPS (Switching Mode Power Supply) into Main PCB

- Stabilize the power supply


- Protect all the electric components of a boiler
- Extend life time of a boiler & the components
- Be able to allow a wider voltage range => 220V±30%
6
3. ACE III Features & Strong Points (2)
 Canned Type Circulation Pump

- Adopt a high precision Canned Type Pump.


- Effectively reduce a noise level.
- Prevent a noise problem due to any attracting iron substance to
the impeller of a pump (especially Magnetic Type Pump).

 Pre-heated hot water delivery system

- Pre-heat the cold water in the piping. (Quick D.H.W button)


- Possible to get the hot water as soon as the tap is up.
- No need to waste water until all the cold water in the piping is drained out.
- To save the gas, this function is released after 10 minutes if not using D.H.W.
7
3. ACE III Features & Strong Points (3)
 APS (Air Pressure Sensor)

- Sense the level of magnetic moving according


to the difference of pressure (ㅿP) between
(+) and (-).
- Give a signal to the main controller to indicate
how much air is being supplied exactly.
- Possible to operate a boiler safely even
there is any sudden change of external impact
(e.g. Contrary or Strong wind).
- Flexibility of flue installation
(e.g. Length and structure of flue installation)

Air Pressure Sensor


Main
PCB
Venturi

(+)

Air
Magnetic (-)
Pole Fan

Hall-IC
8
3. ACE III Features & Strong Points (4)
 APS (Air Pressure Sensor)
- In the real case, the wind is very changeable.
- As you can see the test graph below, (A) case emits much CO if the wind
intermittently blows.
- But in the (B) case (APS), volume of CO is very low and give a stable combustion
even under any changeable wind condition.

Time (min) 2 4 6 8 10 12 14 Time (min) 2 4 6 8 10 12 14


O2 (%) 10.0 10.4 4.8 10.5 5.0 10.5 4.7 O2 (%) 11.0 10.8 10.9 10.6 11.2 10.8 11.0
CO (ppm) 138 98 3200 90 2800 92 3300 CO (ppm) 36 38 35 50 32 40 36
Velocity 0 40 0 40 0 40 0 Velocity 0 40 0 40 0 40 0
(m/s) (m/s)

Time (min.) Time (min.)

(A) By Velocity of Rotational Frequency (B) By APS (Air Pressure Sensor)

* Tested by Navien laboratory


9
3. ACE III Features & Strong Points (5)
 Anti-Freezing System
- Start a circulation pump and circulate water in the heating piping
if the temp. of heating water below 10℃.
- Start a boiler if the temp. of heating water below 6℃ to prevent freezing.
- No need any additional electric heater thanks to inner pipings are short
and D.H.W part can be heated indirectly.

Gas Consumption
 Ratio Control

- Control flame
- After reaching the setting temp., Time
reduce the flame. Ratio Control
- Effectively reduce gas consumption

Gas Consumption
Compared to a On / Off Control

Time
On / Off Control
10
3. ACE III Features & Strong Points (6)
 Adaptive Heating Control Room
Temp.
On/Off Control

- Learn and adapt the specific heating


circumstance.
- Supply the most suitable heating Adaptive Control
according to the each condition.
(e.g. isolation level of the house, Time
change of the temperature outdoor)

 Motorized Cam Shift Type 3-Way Valve

- No wear & durable


- Better sealed compared to a rotating
ball type 3-way valve
- Navien’s own patent technology
11
4. Comparison of GOM+ & ACE III
GOM+ ACE III REMARK
DESIGN

EFFICIENCY (GCV) 82%~83% 83%


VOLTAGE 220V±20% 220V±30%
GAS PRESSURE 100~250mmH2O 50~250mmH2O
COLD RESISTANCE -20℃ -40℃
WATER PRESSURE 0.2bar 0.1bar
SIZE 485*235*630 440*265*695 SLIMED AND
(W*D*H) (525*250*685) STANDARDIZED
PUMP TYPE Magnetic Type Canned Type
H/E Cu STS
CONTROL TYPE CURRENT RATIO ELECTRIC AIR RATIO
* GCV : Gross Calorific Value / H/E : Heat Exchanger
12
5. ACE III Sales Points
Water
Filter
Cold Wider
Resistance Water Pressure
Allowance

ACE III
Wider
A/S Parts
Gas Pressure
Allowance Control
Canned Type