Sunteți pe pagina 1din 3

PASS S.A.

Via Porras, #10 Tel: 263-9787


Panama Fax:
www.passsa.com vpuga@passsa.com

February 22, 2011 Juan Jose Bernal

New project
Solar pumping project

Project data
Solar data: Barrancabermeja, Colombia (7°N; 74°W; 5.2 kWh/m² hor.) Static lift: 18 m Cable length: 23 m
Required output: 700 m³/day in May PV dirt loss: 5.0 % Pipe length: -

Products Quantity Details Item #


PS15k C-SJ95-2 1 pc. Submersible pump system incl. controller, AC-motor and centrifugal pump end 1198
Woneng 10024 176 pc. 17,600 Wp; 16 x 11 modules; 15 ° tilted fixed array -
Cable 23 m 16mm² 3-phase cable -

Annual output Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Flow [m³/day]

Power [kWh/day] 90 85 80 72 70 71 76 78 78 75 78 83 78
Irradiation [kWh/m²day] 6.0 5.7 5.3 4.8 4.6 4.7 5.1 5.2 5.2 4.9 5.1 5.4 5.2
Rainfall [mm/month] 56 85 123 217 234 178 153 183 242 279 205 93 171
Amb. temp. [°C] 23 25 24 24 23 23 23 24 23 22 22 22 23

Output in May. 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00

Flow rate
[m³/h]

Power [kWh] 0.15 2.2 4.7 6.8 8.2 9.1 9.3 8.9 8.0 6.5 4.5 2.1 0.14
Irradiation [kWh/m²h] 0.009 0.13 0.29 0.43 0.54 0.61 0.63 0.61 0.54 0.43 0.29 0.13 0.009
Amb. temp. [°C] 18 18 19 21 23 25 27 28 28 28 28 27 27
Cell temp. [°C] 22 25 31 37 42 46 49 49 47 44 40 34 30
Temp. loss [%] -1.500 0 3.0 6.0 8.5 11 12 12 11 9.5 7.5 4.5 2.5
Cable loss [%] 0 0.060 0.13 0.19 0.23 0.26 0.27 0.26 0.23 0.19 0.13 0.058 0
Pipe loss [m] 0 0 0 0 0 0 0 0 0 0 0 0 0

Created by LORENTZ COMPASS 2.0.1.1 1/3


Errors excepted and possible alterations without prior notice.
PASS S.A.
Via Porras, #10 Tel: 263-9787
Panama Fax:
www.passsa.com vpuga@passsa.com

February 22, 2011 Juan Jose Bernal

New project
Solar pumping project

System performance

Min. at 800 W/m², 20 °C Max./STC*


PV generator Cell temperature [°C] 46 25
Temperature power losses [%] 11 -
Dirt losses [%] 5.0 -
Pmax [Wp] 12,000 17,600
Vmp [V] 494 552
Imp [A] 24 32
Voc [V] 635 691
Isc [A] 29 37
Pout [W] 12,000 -
Vout [V] 530 -
Iout [A] 22 -
Motor cable Power loss [%] 0.053 0.34 0.35
Pump system Motor power [W] 1,850 11,900 12
Motor voltage [V AC] 517 517 518
Motor current [A] 3.6 23 23
Motor speed [rpm] 1,870 3,060 3,070
Frequency [Hz] 33 54 54
Flow rate [m³/h] 0 103 104
Efficiency [%] 0 43 51
*STC: Standard Test Conditions for Photovoltaic Modules, 1000 W/m² inpane irradiation, 25° C cell temperature

Created by LORENTZ COMPASS 2.0.1.1 2/3


Errors excepted and possible alterations without prior notice.
PASS S.A.
Via Porras, #10 Tel: 263-9787
Panama Fax:
www.passsa.com vpuga@passsa.com

February 22, 2011 Juan Jose Bernal

New project
Solar pumping project

Wiring diagram

Created by LORENTZ COMPASS 2.0.1.1 3/3


Errors excepted and possible alterations without prior notice.

S-ar putea să vă placă și