Sunteți pe pagina 1din 1

SAUDIARAMCO.

NOTES:
1. OFFSHORE HELIDECKS SHALL BE DESIGNED IN ACCORDANCE WITH
NORTH SAUDI ARAMCO STANDARD SAES-M-005, MANDATORY STANDARD
PREVAILING WIND DRAWINGS AA-036248, AA-036249 AND CAP 437 (LATEST EDITION).
ALL UNSPECIFIED DESIGN ISSUES SHALL BE RESOLVED BY SAUDI
ARAMCO CONSULTING SERVICES DEPARTMENT.

0.83D
2. TIE DOWN SPACING DIMENSIONS ARE TYPICAL ON ALL PLANS.
DIMENSIONS MAY VARY ACCORDING TO SIZE OF BEAMS.
24000

OF
3. OBSTACLE FREE ZONES, LIMITED OBSTACLE ZONE HORIZONTALLY
0.62D 2
1: AND VERTICALLY SHALL BE MAINTAINED AS PER CAP 437.
150 LIMITED OBSTACLE SECTOR
SAFETY NET 1500MM WIDE

CONSENT
12000 12000
25CM 4. FIRE PROTECTION AND SAFETY REQUIREMENTS SHALL BE IN
(GREEN, VINYL CLAD) ACCORDANCE WITH SAUDI ARAMCO STANDARD SAES-B-009.
LANDING AREA 0.05D
PROVISIONS FOR SAFETY INCLUDE THE FOLLOWINGS:
C
L A. STAIR AND EMERGENCY LADDER SHOWN IS TYPICAL FOR
TYPE-1,2 & 3 HELIDECKS. (SEE SAES-B-009)
D B. THE INNER EDGE OF THE SAFETY NET SHALL BE BELOW

TTEN
0.12D FLIGHT DECK ELEVATION, AND SLOPE UP AND OUT AT MIN.
1 TO 10 SO AS NOT TO EXCEED FLIGHT DECK ELEVATION
24 AT ANY POINT. SAFETY NET MUST SUPPORT 122 kgs/m2

WRI
0.21D GREEN LED PERIMETER LOAD AT ANY POINT. (SEE DETAIL-1)
LIGHTS AT 3000MM
D VALUE MARKING C. FIRE CONTROL EQUIPMENT SHALL BE PROVIDED IN
SECTION-A MAXIMUM SPACING PERIMETER LINE
ACCORDANCE WITH SAES-B-009 AND SAES-B-019.

THE
NAME
MARKING (WHITE)
D. HELIDECK IS SLOPED AT 1 mm IN 100 mm TO DRAIN ON
TYPE 1 AND 2 HELIDECKS ONLY.
HELIDECK IDENTIFICATION

THOUT
E. PERIPHERAL GUTTERS ARE REQUIRED ON TYPE 1 & 2
MARKING-WHITE AIMING CIRCLE (0.5D) HELIDECKS TO SAFELY DIRECT THE FLOW OF SPILLED FUEL.
12000 INSIDE DIA
F. INSTALL PERIMETER LIGHTING AND FLOOD LIGHTS AS PER

WI
A (YELLOW) SAES-M-005 AND CAP 437 ON OFFSHORE HELIDECKS

12000
FLOOD LIGHT PROPOSED FOR NIGHT OPERATION. (SEE NOTE-8)
(TWO ON EACH SIDE)

NG
G. HELICOPTER TIE-DOWN OPENINGS SHALL BE CONNECTED TO
"H" DESIGNATION

DRAWI
A DRAINAGE LINE ON TYPE 1 AND 2 HELIDECKS.
(WHITE)
H. HELIDECK MARKINGS SHALL BE AS PER CAP 437 AND
TYPICAL FOR TYPE 1 & 2.
CHEVRON- BLACK
3000

S
210 OBSTACLE FREE

THI
5. PAINTING REQUIREMENTS FOR HELIDECK CONFORMED TO SAUDI

SECTOR MARKING ARAMCO PAINT SPECIFICATION SAES-H-001.


SAFETY NET
A. PRIMER AND TWO COATS OF EPOXY PAINT APCS-12 ON TOP

00
25
OF HELIDECK.

FROM
1000

R=
0

24000
D R=500 B. THE FINAL COAT IS POLYURETHANE ENAMEL PAINT APCS-1E

24
4000
AS PER SAES-H-101.

C
L
C. COLOR SHADE: REFER TO UBERSICHTSKARTE RAL-K3 COLOR
CARD.

NED
PASSENGER WALKWAY R=700
0
300 WIDE WHITE STRIPES 6. PAINTING IS PERFORMED AS FOLLOWS:

OBTAI
SPACED AT 600 CENTERS A. DARK GREEN
B. RAL 9016
C. RAL 1003
PRIMARY EXIT STAIR D.
HELIDECK LEVEL RAL 9016

BE
TO MEZZANINE DECK E. RAL 9016

1000
F. WEIGHT LIMITATION MARKING - WHITE
5:1 FALLING GRADIENT G. IDENTIFICATION MARKINGS- WHITE

PART,SHALL
12000
H. STAIRWAY AND LADDER OPENING MARKING- RAL 3020, 9016
STAIRWAY & LADDER OPENING ALTERNATE RED AND WHITE

I. HELICOPTER TIE-DOWN MARKING- WHITE RAL 9016


MARKING 150MM WIDE ALTERNATE
TIE-DOWN POINTS-18NOS

7t
SEA LEVEL J. HAZARD BORDER RAL 3020
RED AND WHITE STRIPES (REFER CAP 437) OBSTRUCTIONS THAT ARE NOT OBVIOUS MUST BE MARKED

K. CHEVRON MARKING- BLACK RAL 9005

210 SECTOR "EMERGENCY USE ONLY"

7.
7. INSTALL WINDSOCK, ROTATING BEACON, HELIDECK STATUS LIGHTS
SIGN (SEE SIGN-9 DWG.

N
I
AND WIND INSTRUMENT (WHERE REQUIRED) IN AREA OUTSIDE OF
AA-036249 SHT. 001) OBSTACLE FREE SECTOR ON DECKS EQUIPPED WITH LIGHTING,

FULL,OR
WINDSOCK SHALL BE ILLUMINATED.
3000
180 SECTOR 8. FOR NIGHT OPERATION, INSTALL GREEN LED OMNIDIRECTIONAL

24

1000
LIGHTS TO OUTLINE THE HELIDECK BORDER. IF THERE IS AN
OBJECT THAT IS ABOVE THE HELIDECK ELEVATION BY 15M OR
MORE, THEN THE OBJECT MUST HAVE A RED OMNIDIRECTIONAL
OBSTRUCTION LIGHT OF AT LEAST 30 WATTS INSTALLED AT
THE TOP OF IT. ADDITIONAL RED OMNIDIRECTIONAL LIGHTS

N
NON-SKID FLIGHT DECK WILL BE INSTALLED EVERY 10M DOWN TO THE ELEVATION OF

I
PLAN VIEW (DARK GREEN)
THE FLIGHT DECK IF IT IS GREATER THAN 15M IN HEIGHT.
(OR IF AVIATION DEEMS THAT THE OBJECT NEEDS A LIGHT

ON
TO BE INSTALLED FOR SAFETY REASONS THEN IT WILL BE

REPRODUCTI
WEIGHT LIMITATION EMERGENCY EXIT REQUIRED TO BE INSTALLED). AN EMERGENCY POWER SUPPLY
MUST PROVIDE POWER TO THE PERIMETER LIGHTS, OBSTRUCTION
MARKING (WHITE) LADDER WITH COVER LIGHTS AND FLOOD LIGHTS. LIGHTS SHOULD BE GUARDED, HAVE
(TYPICAL LOCATION) NO EXPOSED WIRING AND BE LOCATED SO AS NOT TO BE AN
OBSTRUCTION.
WITHIN 210 SECTOR
PERIMETER LIGHTS, 9.PREFERRED STAIR LOCATION IS THE NORTH SIDE. IF UNABLE
LANDING AREA NO OBJECTS ABOVE THIS LINE
150 mm (MAX.) TO LOCATE STAIRS ON NORTH SIDE, STAIRS SHALL BE

ABOVE DECK OUTER EDGE OF SAFETY PLAN- TYPE 1 HELIDECK POSITIONED ON THE EAST OR WEST SIDE. STAIRS SHALL NOT
BE POSITIONED ON THE SOUTH SIDE OF THE HELIDECK.
LEVEL NET SHOULD NOT PROTRUDE

SAUDIARAMCO.NO
STAIR HANDRAIL SHALL BE FLUSH WITH THE DECK.
ABOVE FLIGHT DECK
10.ALL NEW HELIDECK DESIGNS AND CHANGES/ UPGRADING/
(SEE NOTE 4b)
MODIFICATIONS TO EXISTING FACILITIES NEEDS TO BE
REVIEWED BY AVIATION TO ENSURE COMPLIANCE WITH LATEST

24000 STANDARDS.
NO STRUCTURE AREA IN WHICH NO STRUCTURE 1
11. FOR HELIDECK WARNING SIGNS DETAILS REFER STANDARD
BETWEEN THESE RIG STRUCTURE BETWEEN THESE 10
DRAWING NO. AA-036249.
LINES IN 180 SECTOR IS PERMITTED LINES IN 180 SECTOR 12000 12000
1500 (MIN)
IN 180 SECTOR 12. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE
NOTED.

C
L
DETAIL-1

OF
NON-SKID FLIGHT DECK
(DARK GREEN)
SAFETY NET

PROPERTY
24
T

5:
EN

1
DI

SOLE
SAFETY NET 1500MM WIDE
FAL
GRA

(GREEN, VINYL CLAD)

NAME

12000
LI
NG

THE
NG
LI

GRA
FAL

ARE
DI
EN
1
5:

N
HEREI
T

00
25
PRIMARY EXIT STAIR NONE

R=
0 SCALE:
500

24000
R=

24
TO MEZZANINE DECK
C
L
SEA LEVEL SEA LEVEL

NED
R=700
0 DRAWING RESPONSIBILITY:

CONTAI
OFFSHORE STRUCTURES COMMITTEE
REVISION VALIDATION
ELEVATION
GREEN LED PERIMETER
THIS REVISION NO. 09 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
LIGHTS AT 3000MM

12000

ON
MAXIMUM SPACING 756200-1216-001

NFORMATI
20mm
IN 22MM
BAR
HOLE 8
6
6
7t
7. DESIGN CERTIFICATION
(DESIGN AGENCY)

ENGG./DATE
REVIEW FOR KEY DRAWINGS
X REQUIRED

CERTIFIED BY/DATE CONST. AGENCY/DATE


(SAUDI ARAMCO)

OPERATIONS/DATE
OTHER

BY/DATE
0

(TYP.) PSK AAS


STIFF PL 12mm
9

6" X 0.438" 10/05/2016 10/05/2016


0

TYP.THK (TYP)
9

6 TIE-DOWN POINTS-18NOS REV.NO. DATE REVISION DESCRIPTION


150 LONG
K K
45

I
(REFER CAP 437) 09 12/2016 CORRECTE NOTE NUMBER 8

THE
JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
40

FLOOD LIGHT 765200 CONSTRUCTION UNTIL CERTIFIED AND DATED

(ON EACH SIDE)


24 SAUDI ARABIAN OIL COMPANY

AND
DRAWING TYPE

PLANS & ELEVATION EQA


EMERGENCY EXIT

NG
6 LADDER WITH COVER OFFSHORE HELIDECKS TYPES 1 & 2

DRAWI
TYP.
DETAIL-2 6
(TYPICAL LOCATION)
STANDARD DRAWING

HELICOPTER TIE-DOWN SECTION "K-K" STD. DWG. SAUDI ARABIA


PLAN- TYPE 2 HELIDECK

S
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

THI
990 A AA-036248 001 09
Saudi Aramco 2615 ENG. (05/05)

RESTRICTED VECTOR CADD-05