Sunteți pe pagina 1din 58

Capitolul 1

PRINCIPII ALE
TEHNOLOGITLORIMAGISTICE
Partea 1

Radiologia conventionala

Bibliografie
1. Gregg EC - Effects of ionizing radiation on humans - in: Waggener RG, Kereikas JG (editors) - Handbook of medical physics, Volume
II. CRC Press Inc., Boca Raton, 1984.
2. Attix FH, Roesch WC (Eds) - Radiation Dosimetry. Volume 1. Academic Press, New York, 1968.
3. Nagel HD - Radiation exposure in Computed Tomography - 4th revised Edition - CTB Publications, Hamburg, December 2002
4. ## - Protection against ionizing radiation from external sources used in medicine. ICRP Publication 33. Pergamon Press, Oxford,
1982.
5. ## - Radiological protection and safety in medicine. ICRP Publication 73. Pergamon Press, Oxford, 1996.
6. ## - Quality Criteria for Computed Tomography. EUR 16262. Office for Official Publications of the European Communities. Luxembourg
1999
7. ## - Avoidance of radiation injuries from medical interventional procedures. ICRP Publication 85. Ann ICRP 30 (2)., 2000; Pergamon
Press, Oxford
8. ## - Quantities and Units in Radiation Protection Dosimetry. 1CRU report 51. Bethesda, USA, 1993.
9. BushbergJT, SeibertJA, LeidholdtJr. EM, BooneJM - The Essential Physics of Medical Imaging, 3rd Ed. - Walters Kluwer, Lippincott
Williams & Wilkins, Philadelphia, 2011
Capitolul I. Principii ale tehnologiilor imagistice

1. Bazele fizice de formare a imaginii in Tubul de radiatie X contine o anoda rotativa (sarcina
pozitiva), precum si un filament catodic fix. Incalzirea fila-
radiologia conventional^; radiatia X: mentului catodic determina generarea unui flux de electroni
proprietati; factorii care influenteaza ce se indreapta spre anoda rotativa. ,,Ciocnirea" acestora cu
calitatea imaginii si doza de iradiere in anoda genereaza o mica cantitate de radiatie X. Pentru a nu
topi suprafata de impact dintre anoda si fasciculul electronic,
radiodiagnostic anoda se roteste, astfel incat suprafata de contact cu fluxul
Adrian Santa electronic se modifica permanent. Suprafata de emisie a
anodei este inclinata cca. 15 grade, pentru a orienta radiatia
X spre fereastra de iesire a tubului, astfel fasciculul X fiind
Radiatia electromagnetics. Radiatia X este o radiatie
orientat spre tinta. Modificand miliamperajul (mA) filamen-
ionizanta (poate detasa un electron din complexul atomic),
tului catodic, se modifica cantitatea de radiatie X emisa,
situata in spectrul radiatiilor electromagnetice in apropierea
fara a fi afectata penetranta radiatiei, energia sau distributia
radiatiei gamma, in cadrul radiatiilor cu energie inalta. Ea
acesteia. Modificarea penetrantei, a energiei si a distributiei
se situeaza in afara spectrului vizibil, incat nu o vedem si nu
energiei este posibila prin modificarea kV.
o detectam cu ajutorul organelor de simt umane (de unde si
Valorile miliamperajului si a kilovoltajului, respectiv
riscul de minimalizare a efectelor acesteia).
durata expunerii in secunde, sunt esenfiale pentru calitatea
Proprietatile RX: se imprastie sferic din punctul de ori-
imaginii si pentru doza absorbita. ele fiind specifice si trebuind
gine (legea divergentei); se propaga in linie dreapta, cu viteza
adaptate pentru fiecare organ in parte sau chiar pentru fiecare
luminii; intensitatea lor scade cu patratul distantei parcurse;
pacient. Cresterea kilovoltajului genereaza o radiatie mai
penetrabilitatea (duritatea) este invers proportionala cu lun-
penetranta. in timp ce cresterea mAs genereaza radiatie mai
gimea de unda; sunt emise si absorbite in cuante de energie;
densa, cu energii mai mici. Daca pentru structuri putin dense
sunt absorbite de corpurile pe care le strabat; absorbtia RX
(torace) se folosesc valori mari de kV si mici de mAs, pentru
este guvernata de legea Bragg-Pierce; produc fenomen de
regiuni anatomice dense (abdomen) se prefera kV mai scazut
luminiscenta (fluorescenta, fosforescenta); produc efect
si mAs mai ridicat. De retinut ca efectele nocive biologice
fotosensibil prin efectul fotolitic; produc ionizare; produc
sunt mai accentuate la kV scazut, cantitatea de radiatie care
efecte biologice.
nu penetreaza corpul ci produce local efecte biologie fiind
Generarea (producerea) radiatiei X se face printr-un an-
mai mare. Aparatele moderne sunt prevazute cu IONTOMAT,
samblu electric ce contine mai multe elemente, reunite generic
dispozitiv care ,,citeste" radiatia ce a penetrat pacientul si
sub numele de ,,generator de radiatie X". Acesta trebuie sa
opreste emisia de radiatie cand aceasta este suficienta pen-
contina un tranformator de inalta tensiune, un tub de radiatie
tru diagnostic. De asemenea, sistemele moderne au valori
X si o serie de elemente auxiliare (motor de rotatie a anodei,
prestabilite pentru diverse regiuni anatomice si greutati ale
sistem de racire etc).
pacientului, de regula sub forma de pictograme.
Transformatorul de inalta tensiune contine o infasurare
primara si o infasurare secundara peste un miez de fier,
infasurarea secundara fiind mai mare si generand curent de
inalta tensiune (kV). Cresterea valorii kV determina cresterea
energiei radiatiei X, respectiv determina cresterea penetrantei
radiatiei. Alti factori important} sunt reprezentati de miliam-
peraj (mA) - determina cantitatea de radiatii X - si durata
emisiei radiatiei (in ms). La valori diferite ale mA si duratei
(ms), produsul egal al acestora determina expunere identica.
Cu alte cuvinte cresterea intensitatii ,,mA" si scaderea timpu-
lui ,,s" cu produs egal, determina aceeasi expunere.
Prin conventie, puterea unui generator se calculeaza astfel:
prin inmultirea unui kilovoltaj fix de 100 kV cu miliamperajul
maxim general in timp de 0,1 s, stabilindu-se astfel valoarea
maxima emisa. De exemplu, un generator ce poate emite 500
mA timp de 0,1 s cu 100 kV va produce 500 mA x 100 kV =

1
50 000 watt = 50 kW, deci este un generator de 50 kW.
Radiologie imagislica medicala

2. Interactiunea dintre radiatia X si mate- - Sursa de radiatie (tubul Roentgen)


- Vectorul (fascicolul de radiatie)
rie, rolul acesteia in obtinerea si calitatea - Modulatorul (tinta de examinat)
imaginii; componentele unui echipament - Receptor
de radiologie conventionala; mecanisme - Decoder
- Imaginea finala
de producere a radiatiei X si a imaginilor; 1. Sursa de radiatie
structura, rolul si functionarea filtrelor si In toate sistemele radiologice care folosesc radiatia X,
sursa de radiatie este tubul Roentgen cu anoda si catod inchise
colimatorilor intr-un tub vidat. Tubul vidat este inchis la randul sau intr-o
Adrian Santa cupola radioopaca (de regula metal greu-plumb) cu exceptia
unui mic orificiu (fereastra) prin care radiatia este orientata
Radiatie ionizanta, radiatia X genereaza efecte biologice spre tinta. Astfel se impiedica imprastierea radiatiei X in alte
de care practica medicala trebuie sa tina seama pentru a evita directii decat cea dorita. In fata orificiului se afla un sistem
sau reduce la minimum efectele nocive ale acesteia asupra de filtre metalice de grosimi si material diferit (aluminiu,
cupru), cu rol de filtrare (retinere) a radiatiilor ,,moi", inutile
organismului uman. Principalele efecte generate de radiatia X
examinarii. Tubul genereaza caldura, fiind dotat cu sistem de
sunt efectul fotoelectric si efectul Compton, alte efecte gene-
racire cu aer sau ulei.
rate de interactiunea radiatiei X cu substanta fund mai putin
Caracteristicile anodei
importante biologic (formarea de perechi si altele necesitand
Anoda este un disc antrenat in rotatie de catre un motor
energii cu mult peste cele folosite in medicina).
electric, astfel incat fasciculul de electroni emis de catod sa
Absorbtia RX este guvernata de legea Bragg-Pierce: absob-
nu atinga anoda mereu in acelasi punct, pentru a evita topirea
tia = Z4l3pgAt unde Z = numarul atomic (mediu) al obiectului
sa (prin supraincalzire). Astfel, exista un diametru specific al
iradiat; A. = lungimea de unda a RX; p = densitate obiectului
anodei, dar si o panta a marginii, care orienteaza fasciculul
iradiat; g = grosimea obiectului iradiat; At = durata iradierii.
de radiatie spre orificiul de iesire. Panta este de regula dubla,
Efectul fotoelectric consta in interactiunea completa
cu un unghi mai mic si cu un unghi mai mare, realizand doua
intre fotonul ,,X" incident si atom. Fotonul ,,X" este complet focare (focar mare si focar fin, necesar examinarilor detaliate,
absorbit, generand emisia unei radiatii ,,X" -caracteristice, in special osoase). Toate anodele au o tensiune maximala
si a unui foto-electron. Coeficientul de atenuare al efectului aplicabila, o putere instantanee (in kVxmA) = Watt si o putere
fotoelectric depinde de numarul atomic al atomului. Efectul conventionala (puterea generata in 0,1 s - exprimata in Watt).
fotoelectric scade dramatic cu cresterea energiei fotonului X Anoda are o capacitate termica proprie, sistemul de racire
si creste cu cresterea numarului atomic Z al substantei tinta. fiind astfel calibrat incat sa disipe energia termica produsa
De aceea, absorbtia osului fata de radiatia X este mult mai de anoda in timpul functionarii. La acestea se adauga gene-
mare decat cea a tesuturilor moi si de aceea plumbul este un ratorul electric (cu transformator, redresor, temporizor, masa
foarte bun protector fata de aceasta radiatie (numar Z mare, de comanda), majoritatea electronice la aparatele moderne.
ce determina absorbtie mare). 2. Vectorul
Efectul Compton reprezinta un alt tip de interactiune in Se defineste ca radiatie ,,X" emisa de tub si care va
comparatie cu efectul fotoelectric, fotonul X fiind deviat prin produce in final imaginea radiologica. Are trei componete,
ciocnirea cu electronii externi ai atomului tinta, rezultand radiatia incidenta (cea emisa de tub si care calatoreste spre
devierea atat a fotonului X, cat si a unui electron din atom, tinta), radiatia absorbitd (cea care nu trece de tinta exami-
cu imprastierea radiatiei X si ionizare. nata, fiind blocata prin absorbtie sau deviata prin refractie,
Fotonii cu energie joasa (60 kV) genereaza in principal reflexie de structurile interne ale tintei) si radiatia reziduala
efect fotoelectric; la valori de cca 140 kV, energia transferata (cea care a trecut dincolo de tinta si se indreapta catre recep-
in organism de efectul fotoelectric si de efectul Compton sunt tor). Radiatia reziduala este cea care poarta informatia utila
relativ egale, in timp ce la energii mari (200kV), predomina in diagnostic, ea fiind modulata prin trecerea prin structurile
efectele generate de interactiunile tip Compton. tintei, si avand intensitati diferite in functie de densitatea
Componentele unui sisteni radiologie structurilor traversate.
Schematic, orice sistem radiologie poate fi decompus in 3. Modulatorul (tinta)
cateva ,,piese" componente, obligatorii pentru obtinerea unei In radiologia medicala, modulatorul (tinta) este reprezen-
imagini finale. Acestea sunt: tat de catre regiunea corpului uman sau a piesei anatomice
Capitolui 1. Principii ale tehnologiilor imagistice

examinate. La trecerea radiatiei X prin modulator, se produc 3. Principiile achizitiei imaginilor radi-
atat efecte direct ionizante (prin coliziune si franare), cat si
indirect ionizante (prin efect Compton. efect fotoelectric, ografice; rolul filmului, al ecranelor (in
producere de perechi), toate acestea fiind nocive pentru radiografia analogica), al grilelor antidi-
pacient. Radiatia care reuseste sa treacS prin modulator va
produce imaginea finala.
fuzoare si influenta acestora in calitatea
4. Receptorul si 5. Decodorul imaginii obtinute si in timpul de expune-
Obtinerea unei imagini radiologice se face prin ,,colecta- re; principiile achizitiei imaginilor digi-
rea" in diverse moduri a radiatiei X ce a traversal modulatorul
(corpul uman). Diferen|ele intre Jesuturile traversate vor tale in radiologia digitala; factorii care
genera diferente in radiatia X receptata. ducand la formarea afecteaza calitatea imaginii in radiologia
imaginii. Captarea radiatiei X se face pe film radiologic (ra- conventionala si digitala
diografie), pe placi de scintilatie (radioscopie), cu sau farS
amplificare si transformare in imagine analogs sau digitals, Adrian Santa
sau pe receptori cu gaze rare - Xenon (Computer Tomogra-
fie). Rolul decodorului, indiferent de tip (pamanruri rare din Pentru obtinerea radiografiei, se foloseste un film
folia intSritoare, cristale sau xenon etc) este de a transforma fotografic, inchis intr-o casetS izolata fata de lumina ambi-
radiatia X invizibila in radiatie luminoasa ce poate impresiona entalS. Impresionarea filmului direct de cStre radiatia X se
filmul sau in impuls electric (in cazul CT) ce poate fi apoi face in mica masurS (2%), expunerea acestuia fiind fScuta
reconstruit in imagine. in principal de lumina in spectru vizibil generata defoliile
6. Imaginea finala (ecranete) mtaritoare. Acestea cSptusesc interiorul casetelor
Daca la radiografia conventional^ imaginea finala este radiologice de ambele parti, fiind formate din folii de plastic
reprezentatS de filmul radiologic expus si developat, in sis- impregnate cu saruri care au proprietatea de a emite lumina
temele digitale, imaginea radiologies reprezinta unfisier, de vizibila atunci cand sunt bombardate cu radiatie X (fenomen
regula intr-un format medical ce contine date multiple, eel mai de fosforescenta). SSrurile cele mai folosite sunt tungstatul
folosit actualmente fiind formatul DICOM3, acesta putand de calciu sau ,,pamanturile rare", acestea din urma fiind mult
fi vizualizat pe monitor de calculator, putand fi prelucrat in mai eficiente. Cu cat stratul de fosforescenta este mai gros.
termeni de fereastrS si centru de fereastrS, putand fi transmis cu atat casetele necesita mai putina expunere (genereaza
la distantS sau stocat electronic. Tendinta moderna este de a lumina mai multa, cu expunere mai rapida a filmului), insa
renunta la suportul pe film radiologic sau termic in favoarea finetea imaginii scade. Exista folii intensificatoare care emit
imaginilor electronice, mult mai versatile. lumina albastra sau verde, fllmul folosit trebuind sa fie de
acelasi tip cu folia (film sensibil la lumina albastra sau verde),
pentru obtinerea unui rezultat cat mai bun. Filmele ,,verzi", in
casete cu intaritori din pamanturi rare, ce emit lumina verde,
necesita timpi de expunere mai scurti (reducand artefactele de
miscare) si constante de emisie mai mici (reducand efectele
nocive asupra organismului).
Efectul Compton, prin ,,imprastierea" radiatiei X, produce
fotoni cu directie diferita de cea incidenta, ceea ce determina
scaderea contrastului imaginii pe film (cu aparitia de ,,flu" -
imagine imprecisa, stearsa). Pentru reducerea acestui efect,
intre pacient si film se interpune o grila (antidifuzoare)
formata dintr-o alternants de benzi fine de plumb si plastic,
care vor permite trecerea spre film doar a acelor fotoni X ce
au directie incidents (perpendiculars) pe film, iar cei deviati,
cu directie oblica, fiind opriti de fasiile de plumb. Pentru a
nu se imprima si ea pe film, grila se misca cu viteza mare,
vibratorie, in timpul expunerii (grila Bucky). Filmul expus
este apoi developat intr-o solutie de revelator si fixat in solatia
Radiologie imagisticd medicala

de fixator, cu spalari intermediare si spalare finala, urmate de si multislice moderne. Exista un numar de limitari ale
uscare. Acest lucru se poate face manual, cu control la lumina examinarii CT si, de asemenea, examinatorul trebuie sa
inactinica (rosie sau verde) sau automat, in masini automate tina cont si de doza relativ mare de iradiere a pacientului
de developare. Exista tendinta de trecere spre radiografie in cadrul unei examinari CT.
digitals, in care filmul, de tip special, este developat termic,
farS revelator sau fixator (procedeu uscat).
Tomografia plana 4. Principiile radioscopiei; indicatiile
Din radiografia clasica derivS tomografia plana, o me-
toda de selectare a unui plan de interes din intregul volum radioscopiei; optimizarea protocoalelor
al organismului examinat. Spre deosebire de radiografia de explorare radioscopica; tehnici de
simplS, in care tubul de radiatie, pacientul si caseta cu
filmul radiologic raman nemiscate in timpul expunerii, in
imbunatatire a calitatii imaginii si de
tomografia plana tubul este solidarizat prin intermediul reducere a radiatiei in radioscopie
unui brat de caseta radiologies. Pacientul este situat intre Adrian Santa
tub si caseta, acestea efectuand o miscare de translate in
jurul unui punct fix ales de examinator, ce se situeaza la
nivelul unde se doreste efectuarea planului de sectiune. Spre deosebire de imaginea radiografica, radioscopia
Cu alte cuvinte, pacientul se afla intins pe masa de exa- difera atat prin faptul ca imaginea este obtinuta pe un supon
minare, iar tubul si caseta executa o miscare de baleiaj fluoroscopic, cat si prin faptul ca este o examinare ,,in timp
deasupra (tubul), respectiv dedesubtul pacientului (caseta real", dinamica. Dupa traversarea tintei, radiatia X cade pe
cu film). Punctul in jurul caruia se face bascula este situat o placa fluorescenta ce poate fi vizualizata direct (la intu-
la nivelul planului de examinare al pacientului, putand fi neric), sau poate fi receptata de un sistem electronic analog
ridicat (sectiuni ventrale) sau coborat (sectiuni dorsale) sau digital, ce o transforms in imagine TV. Radioscopia
dupa dorintS. Structurile situate anterior sau posterior de directa este scoasa din uz, astazi nici o firma din lume nu
planul de rotatie se imprima succesiv in diferite locuri pe mai construieste astfel de aparate, iradierea pacientului si a
film, neproducand o imagine fixa. Singurele structuri care medicului fund foarte mare. Sistemele moderne cu lant TV
nu-si modifies pozitia, pastrand aceeasi situare si acelasi prezinta si posibilitatea manipularii in totalitate a aparatului
loc de expunere pe film sunt cele din planul de basculare al si a pacientului dintr-o camera separata, prin telecomanda,
bratului. Prin ridicarea sau coborarea acestuia, se pot obtine astfel meat iradierea personalului medical sa fie exclusa.
felii la diverse nivele. Totusi, rezolutia acestor imagini este Pentru obtinerea unei imagini diagnostice, sunt importante
scazuta, aparitia tomografiei computerizate reducand pana doua tipuri de rezolutie: rezolutia spatiala si rezolutia de
aproape la disparitie uzul acestei metode. contrast. Rezolutia spatiala reprezinta dimensiunea cea mai
Computer-tomografla mica a unei structuri ce poate fi afisata separat de cele inconju-
Tot din familia metodelor radiologice (care folosesc ratoare (cu alte cuvinte, cat de mici pot fi doua puncte care pot
radiatia X) de diagnostic face parte si tomografia compu- fi vazute separat). Rezolutia de contrast reprezinta diferenta
terizatd (CT). Principiul CT deriva din tomografia plana, minima in tonuri de gri a doua structuri ce pot fi percepute
prin asezarea pacientului in centrul unui cere, la periferia separat, de sine statator. Aceste tipuri de rezolutie depind de '
caruia, in opozitie, se afla un tub de radiatie X si un sistem performanta unui sistem digital, respectiv de dimensiunea
de detectori. Ansamblul tub-detectori se roteste in jurul cristalelor de saruri de argint in cazul filmului radiologic.
unui plan axial din corpul pacientului, vizualizand Struc- Imaginea radioscopica poate fi inregistrata digital (pe
turile din acest plan din diverse unghiuri ale unui cere de caseta, CD sau in memorie electronica) si, de asemenea,
360 grade, realizand o harta a densitStilor din acest plan (o poate fi expusa pe film, ca radiografie a celor mai importante
imagine de sectiune). Deplasand pacientul la un alt nivel, imagini din punct de vedere diagnostic.
se poate realiza o serie succesivS de sectiuni transversale Angiografia
prin corpul acestuia, cu mare rezolutie si buna calitate Din combinarea radioscopiei digitale cu radiografia deriva
diagnostic^. Evolutia sistemelor tomografice continuS metodele specializate in exploararea vasculara (arteriografia
spectaculos, de la obtinerea unei sectiuni in 19 minute siflebografia). Acestea reprezinta obtinerea de imagini ale
in 1975, la obtinerea de 128, 256 si chiar 512 sectiuni lumenului vaselor arteriale sau venoase prin injectarea directa
concomitent in mai putin de o secunda in sistemele spiral in lumenul acestora de substante de contrast, cu radiografierea
Capitolul 1. Principii ale tehnologiilor imagistice

sau evaluarea in radioscopie a lumenului acestora. Pentru o Pe masura ce rezolutia detectorilor electronici a crescut,
imagine cat mai fidela, sistemele moderne folosesc sursa si filmul radiologic a fost inlocuit cu sisteme digitale (rezolutii
receptor digital, multiplanara (doua ,,C-arm" - uri). reusind peste 1024/1024 pixeli) si, recent, unrol important in diagnos-
sa efectueze substractia din imagine a structuilor osoase si tic revine tomosintezei, metoda noua digitala de evaluare a
parenchimatoase si de asemenea obtinand imagini multipla- parenchimului mamar. Tomosinteza evalueaza tesutul mamar
nare sau chiar tridimensionale prin reconstructie de catre din mai multe unghiuri (30-50 unghiuri diferite), prin baleie-
calculator. rea in arc de cere asemanatoare tomografiei plane. Rezultatul
Precautiunile si contraindicatiile legate de substantele de este o imagine de mare rezolutie, cu caractere 3D, studiile
contrast sunt aceleasi ca si in radiologia si computer-tomo- actuale sugerand o capacitate de detectie a patologiei mai
grafia clasica. mare decat cea a mamografiei conventionale.
Uneori, pentru un diagnostic morfopatologic complet
sau in scop de cercetare-publicatii stiintifice, este necesara
5. Principiile si particularitatile radiogra- obtinerea de imagini radiologice a unor piese anatomice.
Desi se pot folosi aparate de radiologie conventionala, prin
fiilor de tesuturi moi (exemplu: mamo- utilizarea focarului fin, a filmelor rapide si a unor constante
grafia); principiile radiografiei pieselor adecvate, exista pe piata de aparatura medicala aparate
anatomo-patologice specifice pentru radiografia de piese anatomice. Acestea
functioneaza in gama 10-100kV, au iontomat pentru expu-
Adrian Santa nere automata si sunt de regula digitale, producand imagini
de mare rezolutie in format DICOM 3, ce pot fi analizate pe
Datorita dimensiunilor si in special datorita densitatii sca- computer utilizand sofruri specifice.
zute a tesutului mamar, evaluarea acestuia necesita examinare
specials, de mare rezolutie, numita mamografie.
Tesutul mamar este predominant lipidic, motiv pentru care 6. Dozimetrie; Kerma, doza de energie
energia radiatiei X necesara obtinerii de imagini este redusa.
In acelasi timp, elementele patologice sunt subtile, de mici absorbita (Gray), doza efectiva (Sievert)
dimensiuni (calcifieri punctiforme, spiculatii fine periferice), - definire si explicare; biologia radiatiilor
necesitand o rezolutie a imaginii peste cea obisnuita la alte
aparate si sisteme.
- iradiere, efecte biologice; efectul asupra
Aparatele specifice evaluarii tesutului mamar poarta nu- dozei si calitatii imaginii pe care il are
mele de mamografe. Mamografele au ca element constructiv modificarea kV si mA; raportul dintre
un compresor ce aplatizeaza tesutul mamar, etaland mai bine
patologia si reducand miscarea involuntara in timpul exami- calitatea diagnostica a imaginii si mini-
narii. De asemenea, mamografele moderne au in constructie mizarea dozei efective
atat iontomat pentru expunere cu constantele optime, cat si
posibilitatea de efectuare a punctiei bioptice a leziunilor sau
Adrian Santa
de introducere a unui fir ghid (ancoraj), prin ghidaj stereo-
tactic. Se obtin, de regula, doua clisee pentru fiecare san, un Pentru o buna definire a problemelor legate de doza de
cliseu cranio-caudal si unul oblic-lateral pentru evaluarea radiatie si masurarea interactiunii intre radiatia X si substanta
mai buna a regiunii axilare. In functie de necesitati, se pot biologica (pacientul), sunt necesare cunoasterea unor date
folosi si alte incidente. specifice:
De cele mai multe ori reglate prin iontomat, valorile - Expunere si rata expunerii
uzuale de constante sunt 28-35 kV si cca 200 mAs, mult sub - Doza absorbita, KERMA
cele folosite in radiologia abdominala. - Doza medie absorbita in tesut
Filmele radiologice folosite pentru mamografie sunt de - Doza echivalenta
asemenea speciale, avand emulsie fotosensibila pe o singura - Doza efectiva
parte, tot pentru o rezolutie mai buna. Si casetele de mamo- - Cantitati dozimetrice (doza la suprafata si in profunzi-
grafie sunt concepute specific, pentru a produce imagini clare me, factorul de imprastiere etc)
si detaliate. - Cantitati dozimetrice specifice (mamografie, CT etc.)
10 Radiologie imagisticd medicala

Expunerea si rata expunerii Doza echivalenta H


Expunerea reprezinta o cantitate dozimetrica pentru Doza echivalenta H reprezinta doza absorbita multipli-
radiatia ionizanta, bazata pe abilitatea radiatiei de a pro- cata cu un factor de masurare a radiatiei, wR care exprima
duce ionizare in aer. Aceasta cantitate este definita doar eficacitatea biologica a unui anumit tip de radiatie. Pentru a
pentru interactiunile produse de radiatie in aer. Inainte de evita confuziile cu doza absorbita, unitatea de masura SI a
a interactiona cu pacientul sau examinatorul, radiatia X dozei echivalente se numeste Sievert (Sv). Unitatea anterior
interactioneaza cu aerul. Notiunea ,,expunere" ofera indicatii folosita era rem, cu relatia lSv= 100 rem. Pentru majoritatea
despre capacitatea radiatiei X de a produce anumite efecte radiatiilor utilizate in medicina, wR = 1, adica doza absorbita
in aer, considerandu-se ca efectele in tesuturile vii vor fi, in si doza echivalenta au aceeasi valoare (sunt egale).
general, proportionate cu cele din aer. Expunerea reprezinta Doza efectiva
valoarea absoluta a incarcarii ionice totale produse in aer Expunerea la radiatie a diferitelor structuri duce la
atunci cand toti electronii eliberati la interactiunea cu fo- probabilitati diferite de leziuni datorate radiatiei si la grade
tonii (per unitatea de masa) sunt complet opriti (franati in diferite de severitate. Combinatia intre probabilitatea si se-
totalitate) in aer. veritatea leziunilor se numeste ,,detriment".
Unitatea de masura international;! a expunerii este expri- Pentru a evidentia detrimentul combinat produs de efec-
mata in Coulombi / kilogram (C/kg) sau roentgeni (R = 258 tele stocastice determinate de dozele echivalente in TO ATE
microcoulombi / kg). Desi Roentgenul nu mai reprezinta o organele corpului, doza echivalenta in fiecare organ si tesut
unitate stiintific acceptata, mai este folosit in radiologie. este combinata si inmultita cu un factor de masurare WT,
Rata expunerii reprezinta expunerea raportata la unitatea rezultatele insumate pentru intregul corp producand DOZA
de timp. Unitatea internationala pentru rata expunerii este EFECTIVA, E. Exista tabele pentru WT pentru fiecare organ
Coulomb/kg/sec, putand fi folosit si R/sec. (creier, maduva hematogena, tesut mamar etc).
Doza absorbita, KERMA Formula matematica pentru doza efectiva E este:
Doza absorbita (D) reprezinta energia absorbita per E = ^ Wt Ht wT unde WT reprezinta factorul de masurare
pentru organ sau tesut iar Ht reprezinta doza echivalenta
unitatea de masa. Din punct de vedere al radioprotec|iei, nu
pentru organul sau tesutul respectiv.
suntem interesati atat de mult in cantitatea de radiatie X ce
Cantitati dozimetrice (doza la suprafata si in profun-
traverseaza corpul uman si impresioneaza filmul radiologie,
zime, factorul de imprastiere etc.)
cat in cantitatea de radiatie CARE SE OPRESTE in corpul
Doza de intrare la suprafata (BSD) reprezinta doza ab-
uman, determinand efecte locale. Astfel, 1 Gray (Gy) repre-
sorbita in aer inmultita cu coeficientii de masa. Masurata la
zinta unitatea de masura acceptata de Sistemul International
suprafata pacientului sau a fantomei, ea include atat compo-
de Masuri, fiind definit ca o energie de 1 Joule / kg. Unitatea
nenta directa de radiatie, cat si contributia fotonilor deviati
folosita anterior era Rad - ul, reprezentand 100 ergi / g.
(reflectati, refractati) din jur, ce nu sunt prezenti de regula in
1 Gy= lOOrad. aer (in aer se considera a fi prezenta doar radiatia incidenta).
KERMA (Kinetic Energy Released in a Mass) se defineste De aceea, este necesara introducerea unui factor de corectie
matematic prin formula K=dE trans/dm. unde dEtrans este suma a radiatiei reflectate. Factorii de corectie pot fi de asemenea
energiei kinetice initiale a tuturor particulelor ionizante gasiti in tabele specifice.
eliberate de fotoni in materialul masei tinta (dm) Unitatea DAP (Dose-Area Product) se masoara in cGyxcm2 si
de masura SI pentru KERMA este J/kg, denumit Gray. In reprezinta doza in aer raportata la o suprafata plana integrata
radiologia diagnostics, KERMA si D sunt egale. Calculul in aria de interes. Exista camere de ionizare cu suprafata mare
dozei absorbite de tinta se poate calcula daca se cunoaste ce pot fi montate pe intreaga suprafata de emisie a tubului
expunerea: (in fa{a diafragmului) pentru a intercepta si integra doza
- D(Gy)=fX(Ckg'), unde f = coeficientul de conversie absorbita pe intreaga suprafata a razei emise. Aceste camere
dependent de mediul de absorbtie. F(aer)=0.869. se numesc DAP-metre. Majoritatea aparatelor moderne vin
Doza medie absorbita in tesut echipate cu asemenea DAP-metre, doza fiind calculata si
Doza medie absorbita de un tesut sau organ (DT) reprezin- afisata electronic sau pe film, pentru a putea cunoa$te doza
ta energia depozitata in acesta, impartita la masa organului sau de iradiere a pacientului. Majoritatea tarilor europene obliga
regiunii expuse. Este posibila o legatura intre expunere si doza prin lege raportarea acestei doze.
in aer sau KERMA, folosindu-se coeficienti de conversie. Cantitati dozimetrice specifice (mamografie, CT etc.)
Valorile dozei absorbite in tesuturi variaza cu cateva Exista cantitati dozimetrice specifice pentru anumite
procente depinzand de compozi|ia tesuturilor. tesuturi si organe cu sensibilitate crescuta la iradiere, cum ar
Capitolu! 1. Principii ale tehnologiilor imagistice

fi AGD (Average Glandular Dose), ESAK (Entrance Surface Exista metode imagistice cu performanta maxima pen-
Air Kerma), folosite pentru o calculare cat mai precisa a tru anumite patologii sau regiuni anatomice si altele cu
dozimetriei, in special in mamografie. perfonnanta redusa. Odata cu dezvoltarea diverselor metode
Un alt domeniu care prezinta cantitati dozimetrice specifi- si tehnici, acest balans se poate modifica. Radiologul trebuie
ce este Computer-Tomografia. Acestea sunt CTDI (Computed sa cunoasca indicatiile relative ale fiecarei metode si sa le
Tomography Dose Index), DLP (Dose-Length Product) si propuna ca atare atunci cand sunt solicitate gresit.
MSAD (Multiple Scan Average Dose). Acestea sunt masu- Exemplele sunt foarte numeroase (indicatie de CT si nu
rabile pe fantome speciale si sunt de asemenea raportate in IRM la traumatisme craniene. indicatie IRM si nu CT la pa-
cadrul fiecarei examinari. CTDI se exprima in mGy iar DLP tologie pelvina feminina, indicatie ecografie pentru patologia
in mGyxcm, aceasta din urma reprezentand doza pentru o tiroidiana etc).
examinare completa. Tot apanajul radiologului este cunoasterea contrain-
Relatiile intre diferitele unitati de masura sunt reprezentate dicatiilor si precautiunilor legate de metode si contrast, in
in urmatorul tabel: acest sens pacientul trebuind sa fie insotit de documentatia
medicala care sa contina date despre sarcina, alergii, valori de
Efect Unitate Unitate sistem Factor conversie creatinina si uree, alte patologii cu potential de rise (mielom,
masurat conventional;} international insuficienta hepatica etc) sau tratamente cu rise (metformin,
(SI) substitutie tiroidiana).
Cantitatea Roentgen (R) Coulomb; kg lR=2,6x lO^C/kg
expunern (C/kg)
Doza Rad Gray (Gy) l G y = 100 rad
Activitate Curie (Ci) Becquerel (Bq) lCi = 3,7x 10 10 Bq
Doza- Rem Sievert (Sv) l S v = 100 Rem
echivalent

7. Valoarea relativa si indicatiile pentru


examinarile radioimagistice ale diverse-
lor organe si sisteme; indicatiile pentru
folosirea substantelor de contrast radio-
imagistice
Adrian Santa

Valoarea relativa si indicatiile examinarilor radio-imagis-


tice vor fi discutate in cadrul fiecarui capital si patologie.
Ca o regula generala, tipul de investigate este actualmente
solicitat de catre medicul clinician, de multe ori acesta ne-
fiind familiarizat cu realele indicatii, non-indicatii sau chiar
contraindicatii ale metodelor. In majoritatea statelor dezvol-
tate, atat indicatia de metoda, cat si cea de administrare de
contrast i.v. apartin radiologului, decizia sa de a folosi sau
nu o metoda sau alta nefiind contestabila. Atata vreme cat
responsabilitatea este a radiologului pentru toate manoperele
pe care le efectueaza, cata vreme radiologul este raspunzator
legal pentru dozele de iradiere sau accidentele postcontrast,
acesta trebuie sa aiba libertatea absoluta de a alege.
Partea a 2-a

Tomografia computerizata (CT)

Bibliografie
1. Wegener OH - Whole Body Computed Tomography, 2nd Ed, Blackwell Scientific Publications, Boston, 1993
2. Prokop M, Galanski M - Spiral and Multislice Computed Tomography of the Body Thieme, Stuttgart, 2002
Capitolui 1. Priucipii ale tehnologiilor imagistice ::

8. Bazele fizice de formare a imaginilor - CT generatia a patra: tub rotator, detectori ficsi
distribuiti 360 grade in jurul pacientului. Scoasa din uz da-
CT; fizica CT-spiral, CT-multidetector torita prefului mare al detectorilor
si CT sursa - duala; componentele unui - Electron-beam CT: micro-anode dispuse 360 grade in
echipament CT; artefacte in CT - surse, jurul pacientului alternativ cu receptori, cu elecroni produsi
intr-un accelerator de particule si accelerati, ce bombardeaza
recunoastere microanodele. Acestea la randul lor emit radiatie X spre
Adrian Santa partea opusa, unde este receptionata de senzori. Ultrarapid,
primul cu aplicatie cardiaca. Scos din uz prin evolutia mul-
tidetector-CT si pretul foarte mare (in special acceleratorul
Definitii: si detectorii).
- CT - Computer-Tomografie. Metoda de obtinere a - CT multitub: Doua tuburi la 90 grade cu emisie de
sectiunilor axiale prin utilizarea unei surse de radiatii si a energie diferita. Concept util pentru atenuarea artefactelor,
unor detectori situati in opozitie cu sursa, cu rotatie in jurul vizualizarea structurilor moi, vasculare, reducerea intaririi
pacientului. de metal, bariu etc
- CT conventional: Miscare rotatorie a ansamblului Reconstructia imaginii:
tub-detectori, in timp ce masa pacientului ramane imobila in - Detectorii transforma radiatia X receptata in semnal
timpul scanarii, dupa care masa este avansata cu increment electric. Acesta este corectat, cu eliminarea inomogenitatilor
mai mic sau mai mare decat grosimea sectiunii obtinute. si a efectului de intarire (beam hardening), fiind codat in valori
- CT conventional multislice (step-and-shoot): prin- de atenuare (raw data).
cipiu identic cu CT conventional, dar cu banda de detectori - Datele brute (raw data) sunt prelucrate de sistemul
(pana la 320), cu obtinere de mai multe sectiuni la o singura electronic in imagini cu tonuri de gri variabile in functie
rotatie de tub. de gradul de atenuare, intre alb (atenuare maxima) si negru
- CT spiral/helical: In timpul rotatiei ansamblului tub- (atenuare minima), cu multiple tonuri de gri intermediare.
detectori masa cu pacientul se deplaseaza constant. Se obtine VOXEL (Volume Element) - PIXEL (picture Element),
o scanare spirala si sectiuni produse in urma reconstructiei Voxel izotropic.
datelor brute obtinute. Numar variabil de detectori (1-128), - Grosimea sectiunii este variabila si stabilita de utili-
cu obtinere de numar variabil de sectiuni. zator. In sistemele spiral multislice este calculata (recon-
Principii de functionare CT: struita). Reducerea extrema a grosimii feliei achizitionate
- sursa de radiatii X se roteste in jurul pacientului, accentueaza zgomotul de fond in detrimentul semnalului
radiatiile X traverseaza axial o sectiune a pacientului in util, limitand grosimea de achizitie (Signal to Noise Ratio
timpul miscarii sursei. Opus sursei de radiatii, un sistem de - SNR). Chiar si la sectiuni foarte fine, grosimea sectiunii
detectori receptioneaza fasciculul atenuat prin parcurgerea nu este neglijabila, de fapt scanandu-se un VOLUM (un
structurilor pacientului, transformand matematic (transfor- disc a carui inaltime reprezinta grosimea sectiunii). Cea
mare Radon inversa) atenuarea intr-o imagine cu tonuri de mai mica unitate de volum care construieste imaginea
gri, variabile in functie de atenuare (densitometrie). Rotatia reprezinta VOXEL-ul. Imaginea reconstruita este un plan,
in jurul pacientului asigura localizarea in plan a structurilor fara grosime. Cea mai mica unitate de imagine (punctul
din sectiune, vizualizate din unghiuri diferite. de gri) reprezinta PIXEL-ul. Pixelul este expresia in plan
Evolutie in timp: a voxelului, formandu-se din ,,contopirea" tonurilor de gri
- CT de prima si a doua generatie: Produs comercial existente in volumul voxelului, cu obtinerea unui singur
prima data in 1973, continand o sursa si un detector ce transla- ton ce reprezinta suma valorilor de atenuare din voxel. In
tau liniar zona de interes fara rotatie, urmata de o rotatie cu ca- interiorul unui voxel exista structuri cu atenuare variabila
teva grade de cere, proces repetat cu perechi translatie-rotatie (volumul acestuia putand cuprinde structuri cu densitate
pana la obtinerea de expuneri pe intreaga circumferinta a diferita), dar pixelul are un singur ton de gri, reprezentand
tintei. Pacientul este apoi deplasat cu masa si procesul se reia. suma densitatilor din voxel. Numarul de pixeli in imaginea
- CT generatia a treia - anii 80. Prezinta o sursa unica CT variaza de la 256X256 la 1024X1024.
(tub) si un evantai de senzori (,,banana" de receptori), cu - Daca dimensiunile voxelului sunt aceleasi in toate
rotatie simultana in jurul pacientului, fara translate si cu de- directiile carteziene (x,y,z), cu alte cuvinte daca voxelul
plasarea mesei intre rotatii. Folosita eel mai frecvent si azi. este un cub, acesta reprezinta voxel izotropic (cu aceleasi
16 Radiologie imagistica medicate

dimensiuni in toate directiile spaliului). Voxelul izotropic Particularitati:


permite reconslruclii in alte planuri decal eel de achizitie cu CT spiral (Volumetric)
rezolutie IDENTICA cu cea din planul de scanare. Achizitia spirala (volumetrica - scaneaza un volum, nu
Artefacte (generalitati): o sectiune) implica o sursa de emisie (focarul tubului de
Artefacte de miscare radialie) si multiple puncle de receplie, desfasurate ,,in evan-
- Pentru a putea reconstrui pozilia exacta a structurilor tai" atat in plan Iransversal (banana de deleclori), cat si de-a
situate in planul sectiunii, este esential ca pozitia acestora lungul axei cranio-caudale a pacienlului, astfel incat achizilia
sa nu se schimbe (sa nu se miste) in timpul scanarii. Depla- spirala se face sub diferile unghiuri fata de planul transversal
sarea structurilor in timpul scanarii duce la ,,vizualizarea" propriu-zis. Acesle unghiuri pun probleme de receplie si
lor de catre detectori in diverse pozitii, cu introducerea pozilionare spatiala a structurilor scanate, corectate de calre
lor in imaginile in toate pozitiile in care au fost detectate, algorilmii de reconslruclie ai calculalorului, ce compenseaza
generand imagini ,,sterse", neclare. Pacientul trebuie sa unghiurile diferile de incidenla-recep|ie.
mentina apnee inspiratorie sau expiratorie la scanarea tora- Caracteristici ale achizitiei spirale:
cica si abdominala. Pacientii necooperanti necesita sedare Vitezu de rotatie versus viteza de deplasare a mesei.
(coma superficiala, copii sub 6 ani). Peristaltica intestinala - Viteza de rotatie a tubului se defmesle ca intervalul de
si contractiile cardiace genereaza artefacte de miscare la timp necesar pentru ca ansamblul tub - deteclori sa efeclueze
aparatele cu achizitie lenta. Aparatele moderne cu achizilii o rotatie completa in jurul pacientului. Aceasta variaza la di-
de 0,3-0,6 sec/rolatie nu prezinta probleme de artefacte de versele tipuri de aparale si chiar la diverse lipuri de examinari.
peristaltica sau cord. Cu cat viteza de rotatie este mai mare, cu atal se pot ,,ingheta"
Artefacte de intarire (beam hardening) struclurile mobile (perislallica. slructuri pulmonare, cord),
- Structurile foarte dense (metal, pasta de Ba) atenueaza reducandu-se artefactele de miscare. Vitezele foarte mari, de
subtotal fasciculul de radiatie, generand con lipsit de semnal 0,33 sec permil evaluare cardiaca si coronariana.
posterior de structura densa, degradand imaginile. Se evita - Viteza de deplasare a mesei esle definita ca viteza (in
scanarea pacienlilor cu proteze metalice voluminoase sau post cm/sec) cu care masa cu pacientul se deplaseaza de-a lungul
Ba pasaj/irigoscopie. Aparatele Dual-source reduc accentual axei Z (cranio-caudale sau invers) in timpul scanarii. Aceas-
artefactele. ta poate fi variabila, permitand valori diferite ale ,,pasului"
Artefacte de volum partial achiziliei.
- Daca voxelul contine structuri cu densitate foarte diferi- - In sistemele spirale monoslice, raportul intre timpul
ta intre ele (ex. aer si sange), pixelul va avea ca rezultat densi- de rotatie si eel de deplasare a mesei, respectiv grosimea
tatea medie a structurilor din voxel, adica nici cea a structurii sectiunii se definesle ca Pitch. Cand dislanla parcursa de
hiperdense, nici cea a structurii hipodense. Valoarea in HU masa in lungul axei Z pe durata unei rotalii complele esle
masurata nu va avea valoarea reala a niciuneia din cele doua egala cu grosimea sectiunii, valoarea Pitch-ului este 1.
structuri. Cu cat volumul voxelului este mai mare (sectiune Aceasla se traduce prin achizilia unui volum cu spirele de
groasa sau matrice de reconstructie mica), cu alal efectul de achizitie perfecl conligue. Un pilch subnumerar (negaliv)
volum partial este mai accentual. Evitarea lui necesita sectiuni implica o vileza a mesei inferioara grosimii feliei, ducand
fine, insa cu cat secliunea este mai fina, cu atat raportul S/N la ,,incalecarea" partiala a spirelor de achizitie. Desi creste
(semnal util/zgomot de fond) va fi mai accentual, rezultand gradul de expunere si iradiere, achizitia cu Pitch subnumerar
imagini grosiere, ,,zgomoloase", fara finele. permite reconstructii mai precise si elimina riscul nescanarii
Artefacte de scanare unor slructuri prezenle in volumul evalual. Deplasarea mesei
- Scanarea cu deplasare a mesei mai mare decat grosi- in timpul unei rotalii complete pe o distanla mai mare decal
mea feliei in unitalea de limp necesara unei rola|ii complele grosimea feliei achizitionale duce la un Pitch supranumerar
duce la spalii inlre spirala scanala (spira inlinsa). spalii ce nu (mai mare decal 1). Aceasla se Iraduce prin spire de achizitie
sunl scanale, imaginea fund o inlerpolare a zonelor scanale, ce nu prezinta contiguilale, spatiile dintre ele fiind inlerpolale
uneori mascand leziuni. Acelasi efecl esle posibil si in CT de calre calculator. Meloda reduce calitatea diagnoslica a
conventional daca ampliludinea respiratorie a pacientului imaginilor, dar creste viteza de scanare si reduce iradierea.
intre doua imagini esle diferila, ducand la posibililatea si- Tndiferenl de valoarea Pitch-ului, volumul achizilionat in
luarii leziunilor mici in afara secliunilor scanate. Scanarea mod spiral este descompus si reconstruit in sectiuni axiale
continua cu Pitch = 1 elimina acesle artefacte (vezi definilia de calre softul calculatorului, utilizand modele matematice
Pitch-ului mai jos). variate.
Capitolul L Principii ale tehnologiilor imagistice 17

- In sistemele multislice. termenul de Pitch poate fi de- Ferestre de examinare


finit in doua moduri, in functie de referinta fata de o singura Afisarea tuturor tonurilor de gri cuprinse intre -1000 si
sectiune (single-collimation - SC) sau fata de intregul volum +3000 HU nu este fezabila diagnostic, examinatorul avand
scanat (total-collimation - N x SC, unde N este numarul de nevoie de mai putine tonuri de gri pentru a accentua contras-
randuri detectori folosit, 2, 4, 8, 16, 64, 128 etc) tul intre structurile cu valori foarte putin diferite intre ele.
Pentru diferentiere, Pitch-ul volumetric se noteaza cu P'. Conceptul de fereastra si de centru al ferestrei are ca scop
Astfel, P = TF/(N x SC) iar P1 = TF/SC, unde TF = table feed ..filtrarea" contrastului si accentuarea acestuia, prin gruparea
(distanta parcursa de masa per o rotatie completa). N = nu- densitatilor similare in grupuri ce sunt afi§ate ca avand aceeasi
marul de randuri de detectori folositi iar SC=grosimea unei densitate. Densitatea afisata este cuprinsa in gama grupului,
singure sectiuni de achizitie. poate fi stabilita de examinator si reprezinta nivelul ferestrei.
Imaginile de pe monitor sunt rezultatul reconstructiei de Astfel, fereastra reprezinta un grup de densita|i apropiate,
sectiuni din volumul scanat, de catre softul calculatorului. grupate intr-un singur ton de gri.
grosimea feliei de reconstructie putand fi diferita fata de Astfel, cu cat grupul este mai mare (cuprinde mai multe
grosimea achizitiei propriu-zise, insa nu sub dimensiunea tonuri de gri). cu atat scala densitatilor este redusa de la 4000
detectorilor folositi (ex: cu detector de 1 mm se pot face tonuri de gri (intre -1000 HU si +3000 HU) la mai putine,
reconstruct!! cu sectiuni de 1 mm si mai man. dar nu sub 1 mm). contrastul dintre ele fiind mai accentual. In extremis, gruparea
tonurilor de gri in doua ferestre ar duce la o imagine in doua
tonuri - alb si negru.
9. Scara unitatilor Hounsfield, princi- Centrul ferestrei reprezinta o densitate dintre cele ce
formeaza grupul ferestrei, cea care va da ,,culoarea" de gri
piul de centru al ferestrei si de largime tuturor structurilor cuprinse in fereastra. De exemplu daca
a ferestrei; setarile optime de centru si avem patru tonuri de gri (impartirea gamei in patru feres-
largime de fereastra pentru diverse orga- tre), in prima fereastra, cea care cuprinde tonurile dintre
-1000 si +1000, vom putea alege centru la oricare valoare
ne si tesuturi; nivele de atenuare in UH intermediara, de exemplu 0, astfel incat toate structurile cu
pentru diverse organe normale si procese valori intre -1000 si +1000 vor fi reprezentate pe ecran ca
avand valoarea 0. Gruparea in numar de ferestre si centre
patologice de fereastra permite evaluarea structurilor scanate in asa-
Adrian Santa numitele ferestre specifice (de os, de parenchim pulmonar,
de tesut moale etc) permitand evaluarea corespunzatoare a
Unitati Hounsfleld unor structuri ce au valori foarte diferite de atenuare. Cu cat
Fiecare voxel si inerent fiecare pixel capata o valoare nu- numarul ferestrelor creste, cu atat pot fi evidentiate mai multe
merica in functie de gradul de atenuare generat de structurile structuri fine (ex fereastra de os are 64 tonuri de gri, fereastra
prezente in voxel. Valoarea numerica a atenuarii este calculata pulmonara 1024).
ca numar CT = 1000x(u-ua a)/uapa. Unitatea de valoare CT Gruparea in ferestre si optimizarea centrului de fereastra
se numeste UNITATE HOUNSFIELD (HU). Valorile HU permite obtinerea contrastului dorit pentru evaluarea patolo-
variaza intre -1000 (aer pur), 0 (apa pura) si valori pozitive giei. Masurarea valorii efective in unitati Hounsfield a unei
crescande, fara limita superioara. Valorile sunt constante structuri oarecare NU DEPINDE de valoarea ferestrei sau
(aceleasi) pentru aceeasi structura indiferent de manipularile a centrului acesteia, nemodificandu-se cu modificarile de
de imagine prin soft (ferestre de examinare) si reprezinta fereastra (valoarea masurata in HU a unei structuri depinde
gradul de atenuare specific din voxelul respectiv, avand ca exclusiv de gradul sau de atenuare a radiatiei roentgen). Ast-
si corespondent un pixel cu un ton de gri specific. fel, indiferent de valorile de fereastra si de centru al ferestrei,
Valoarea in HU a unei structuri permite incadrarea ei in o structura pur lichidiana va avea aceeasi valoare de 0 HU.
diferite categorii de tesuturi (densitati negative pentru aer, Structurile componente ale corpului uman, normale sau
negative apropiate de 0 pentru grasime), 0-30 pentru fluide, patologice, au valori HU definite, ce permit incadrarea lor
pozitive crescand cu densitatea pentru tesuturi, os, metal, 70 in categorii mai largi. Astfel, structurile aerice au valori HU
pentru sange proaspat etc. De asemenea, permite cuantificarea negative, intre -1000 si -300, in functie de cat este proportia
gradului de modificare a densitatii dupa administrarea de de aer sj tesut fin, ca in cazul plamanului. Structurile lipidice
contrast (gradul de iodofilie). au de asemenea valori negative, dar mai apropiate de zero,
18 Radiologie imagistica medicald

de -150 pana la -2-3 HU, de asemenea in functie de raportul inaintea aortei - contrastul parcurge circuitul vena cubitala,
grasime/alte structuri in pixelul masurat. Apa pura prezinta VCS, AD, VD, AP, circulate pulmonara, vene pulmonare,
valori de 0 HU iar structurile fluide valori pozitive intre 0 AS, VS, Ao, vene periferice, VC1). Examinarea trebuie astfel
si 30-35 HU. Exceptie face sangele proaspat extravazat, ce planificata meat scanarea sa se faca atunci cand contrastul a
prezinta valori de 70 HU si se diminueaza cu cca 10 HU/ ajuns in locul dorit si in cantitatea dorita. Pentru facilitarea
saptamana posthemoragie. Structurile tisulare prezinta va- acestei cerinte, aparatele folosesc diverse metode de urmarire
lori pozitive cuprinse intre 35 HU (corticala renala) si 50-70 a contrastului intravascular si de declansare a examinarii, nu-
HU (parenchim hepatic, splenic, pancreatic), iar structurile mite Bolus Tracking sau Bolus Triggering. Concret, se aseaza
cu valori peste 100 HU implica prezenta de calciu sau alte o arie de evaluare (ROI - Region Of Interest) in lumenul
structuri intens atenuante (bariu, substanta de contrast, me- vasului, se injecteaza substanta de contrast, iar aparatul este
tal). Prin masurarea valorii efective a densitatii unei structuri instruit la ce valoare in unita|i Housfield detectata in lumen
se poate stabili apartenenta sa tisulara (lipom versus chist, sa porneasca scanarea. Prin acest protocol se pot face evaluari
de exemplu), caracteristica UNICA pentru CT, nici o alta precoce, in care contrastul se afla doar in sistemul arterial
metoda imagistica neputand cuantifica valoarea de densitate (inaintea reintoarcerii prin capilare spre sistemul venos),
a tesuturilor. Tot prin masurarea valorilor HU pre- si postad- alcatuind ARTERIOGRAFII CT. Este necesara combinarea
ministrare de contrast i.v. se poate certifica prezenta si gradul achizitiei cu viteza mare de deplasare a mesei, pentru acope-
de vascularizatie a unei structuri. rirea intregii zone de interes inaintea reintoarcerii venoase.
Prin folosirea injectomatelor cu doua seringi se poate obtine
atat bolus compact de contrast, dar si separarea de exemplu
a incarcarii cavitatilor cardiace, cu inima stanga cu contrast
10. Principiile imagisticii CT de perfu- si cea dreapta cu ser fiziologic.
zie; principiile si protocoalele de angio- Combinata cu alte achizitii in timpi diferiti, metoda poate
CT, inclusiv modalitatea de utilizare a ,,fractiona" modul in care contrastul parcurge structura tinta in
timpi precoce, tardivi sau de echilibru. O asemenea achizitie
substantelor de contrast si a tehnicilor este necesara pentru caracterizarea, de exemplu, a maselor
de reconstruct^ hepatice, diferitele entitati patologice avand incarcare (Wash-
in) si spalare (Wash-out) diferite, ce permit diagnosticul.
Adrian Santa Scanarea repetata cu mai multi timpi in aceeasi zona se
numeste scanare dinamica si permite alcatuirea unei harti
Imagistica de perfuzie implica administrarea intravas- de intensitate-timp a comportamentului la contrast a structurii
culara (de regula intravenoasa) a unei substante ce contine scanate. Aceste harti (Wash-in Wash-out map) pot fi utilizate
molecule intens atenuante, de regula iod pentru CT. numita de asemenea in caracterizarea diverselor structuri patologice
substanta de contrast cu administrare i.v. Tipurile si caracte- (tumorile maligne au de regula wash-in §i wash-out rapid,
risticile substantelor de contrast sunt discutate intr-un capitol in timp ce tumorile benigne au wash-in mai lent si wash-out
separat. foarte lent, cu curba ,.in platou"). Aceeasi scanare dinamica a
Prin administrarea intravenoasa a substanjei de contrast, substantei cerebrale permite calculul unor parametri specific!
vasele venoase, arteriale dar si parenchimele (normale sau de perfuzie (TTP - Time To Peak, CB V - Cerebral Blood Volu-
patologice) care prezinta flux vascular activ vor prezenta o me, CBF - Cerebral Blood Flow, MTT - Mean Transit Time),
crestere a atenurarii radiatiei X generata de continutul de iod. utili in evaluarea zonelor cerebrale perfuzate, ischemice sau
Atenuarea poate fi definita ca intensitate si timp. cu circulate abolita (conceptul de core-penumbra, adica
Intensitatea depinde de gradul de vascularizatie, fund cu zona centrala de infarct cerebral ireversibil si aria ischemica
atat mai mare cu cat structura este mai vasculara. periferica recuperabila prin tromboliza rapida).
Factorul ,,tirap" este foarte important in doua directii:
timpul necesar ca o structura sa atinga maximul de intensi-
tate, dar si timpul necesar ca substanta de contrast sa ajunga
la acea structura.
Timpul necesar pentru inceputul incarcarii depinde de
multi factori, intre care situarea anatomica fata de vena cubi-
tala in care s-a facut injectarea (artera pulmonara se incarca
Cap/to/if/ /. Principii ale tehnologiilor imagistice 19

11. Protocoale de examinare CT pentru scanate sunt mai putin dense. Exista protocoale adaptate
pentru copii, de asemenea cu reducere a iradierii.
diverse organe si procese patologice; La finalul examinarii, aparatura moderna afiseaza si
optimizarea protocoalelor pentru vari- stocheaza un rezumat al expunerii pacientului, de regula ca
ate tipuri de tomografe; principiile al- doza totals in mGy/cm.
Modalitatile de calcul dozimetric in CT sunt CDTI
goritmilor si kernel-urilor (filtrelor) de (Computed Tomography Dose Index), DLP (Dose-Length
reconstructie; dozimetria CT Product) si MSAD (Multiple Scan Average Dose). Acestea
sunt masurabile pe fantome speciale si sunt de asemenea
Adrian Santa raportate in cadrul fiecarei examinari. CDTI se exprima in
mGy iar DLP in mGy/cm, aceasta din urma reprezentand
Obtinerea unor imagini diagnostice de calitate obliga la doza pentru o examinare completa.
planificarea examinarii CT atat in ceea ce priveste acoperirea
volumului de scanat, cat si in ceea ce priveste modul de ad-
ministrare al contrastului. Pentru a reduce gradul de iradiere 12. Valoarea relativa si indicatiile exami-
al pacientului, aria de acoperire se stabileste astfel incat sa narii CT a diverselor organe si sisteme;
cuprinda doar organul vizat, fara iradieri inutile in afara
acestuia. De asemenea, planningul examinarii trebuie sa tina indicatiile de utilizare a substantelor de con-
cont de diverse caracteristici ale bolii presupuse. Protocoalele trast CT pentru diverse organe si sisteme
specifice sunt foarte multe si nu pot fi discutate in capitolul
de generalitati si fizica / instrumentatie, examinatorul trebu- Adrian Santa
ind sa cunoasca specificitatea tipului de examinare pe care
il efectueaza. Valoarea relativa si indicatiile examinarii CT au suferit
Doar ca exemplificare, evaluarea pulmonara in suspiciu- o dinamica permanenta in decursul deceniilor de la aparitia
nea de proces tumoral primar trebuie sa includa si vizuali- sistemelor CT si pana azi. Astfel, organe considerate candva
zarea suprarenalelor, cea mai frecventa statie de disemnare nediagnosticabile CT (tub digestiv, cord, coronare) sunt azi ru-
secundara in neoplasmul pulmonar si a carei prezenta schimba tina de fiecare zi. Totusi, exista indicatii majore ale examinarii
dramatic stadializarea. La fel, scanarea pentru suspiciunea de CT (traumatismul cranian cu suspiciune de hematom intracra-
neoplasm pancreatic obliga la timp de contrast arterial, foarte nian, hemoragiile cerebrale, evaluarea patologiei pulmonare
precoce, inainte ca structura sa capete acelasi grad de incar- - inaccesibila ecografic si slab evaluata prin IRM), dupa cum
care cu parenchimul adiacent. Scanarea unei mase hepatice sunt si organe sau patologii care sunt slab evaluate CT (pa-
cu contrast trebuie sa includa timp arterial, portal si tardiv, tologia in situ de rub digestiv, substanta alba cerebrala etc).
pentru a putea caracteriza structura patologica. Indicatia si non-indicatia examinarii CT este stabilita
In reconstructia imaginilor din datele brute, examinato- uneori de catre clinician, deseori insuficient informat, discutia
rul va folosi diverse algoritme existente in softul aparatului, cu radiologul fund obligatorie.
menite sa amplifice capacitatea diagnostica. Aceste algo- Decizia de administrare de contrast i.v. si chiar digestiv
ritme specifice sau filtre de semnal se numesc Kernel-uri este intotdeauna deciza radiologului, indicatia clinicianului
de convolutie si stabilesc relatia intre zgomotul de fond si neavand relevanta, nici diagnostica si nici legala. Contrasted
semnalul util, producand imagini mai contrastate (de exemplu i.v. este un adjuvant de diagnostic, pe care radiologul il poate
necesare pentru evaluarea urechii interne si medii) sau mai folosi sau nu, decizia fiind luata in timpul examinarii, tinand
,,moi", necesare evaluarii structurilor tisulare. cont de patologia presupusa, imaginile native si punand in
Dozimetria CT balanta beneficiul diagnostic versus dublarea gradului de
Utilizarea intensiva a radiatiei X in cadrul examinarii CT iradiere si riscul administrarii de contrast (cu potentialele sale
pune problema obtinerii maximului de date cu minimum de ira- reactii, unele letale). Responsabilitatea legala a administrarii
diere. In acest sens, la fel ca in radiologia conventional;!, exami- de contrast este exclusiv a radiologului. Modul si tipurile
narii e CT permit modificareamA si launele sisteme chiar si a kV. de administrare de contrast (protocoalele de contrast) vor fi
Aparatele moderne au incorporate sisteme de modulare a discutate separat la fiecare patologie relevanta in acest sens,
emisiei de tub in functie de datele obtinute in timpul efectuarii fiind prea multe si variate pentru a fi detaliate in capitolul de
topogramei, reducand miliamperajul acolo unde structurile fizica si instrumentatie.
Partea a 3-a

prm rezonanta magnetica (IRM)

Bibliografie
1. ## - Clinical Applications of Functional MRI - Neuroimaging Clinics, 24: (4), 2014
2. Bushberg JT, Seibert JA, Leidholdt Jr. EM, Boone JM - The Essential Physics of Medical Imaging, 3rd Ed. - Walters Kluwer, Lippincott
Williams & Wilkins, Philadelphia, 2011
3. Haaga JR, Dogra VS, Forsting M, Gilkeson RC, Ha HK, Sundaram M - CT and MRI of the Whole Body, 5th Ed. - Mosby Elsevier,
Philadelphia, 2009
4. Reimer P, Parizel PM, Meaney JFM, Stichnoth FA - Clinical MR Imaging. A Practical Aproach - Springer, New York, Heidelberg, 2010.
5. Barker PB, Bizzi A, De Stefano N, Gullapalli R, Lin DDM - Clinical MR Spectroscopy . Techniques and Applications - Cambridge
University Press, Cambridge, 2009
6. Gorenstein DC - Phosphorous-31 NMR: Principles and Applications - Academic Press, Elsevier, New York, 2012
7. van ZijlPCM, Rothman D - NMR studies of brain C-13-glucose uptake and metabolism - present status - Magn Reson Imag. 1995; 13:1213-11
Capitolul 1. Principii ale tehnologiilor imagistice 23

13. Bazele fizice ale IRM; formarea ima- xy. Aceasta revenire se numeste FID (free induction decay) si
necesita un timp variabil pentru revenire, dependent de tipul
ginii in IRM; principiile principalelor structurii (apa, muschi, alte tesuturi, grasime), unele revenind
secvente de puls (spin-eco si ecou de rapid, altele mai lent. Timpul necesar pentru ca 63% din masa
gradient) si a timpilor de relaxare; com- de protoni ai unei anumite structuri sa revina la valoare ma-
xima pe axa z este o constants de materie si se numeste Tl.
ponentele unui echipament IRM Valoarea Tl depinde atat de intensitatea campului magnetic,
Adrian Santa cat si de structura intrinseca a substantei.
Pe masura ce vectorul z creste, vectorul din planul xy
scade (suma vectoriala). Intervalul de timp necesar ca 63%
Imagistica de rezonanta magnetic! are la baza fenomene de din protonii unei anumite substance sa dispara din planul xy
fizica cuantica ce pot fi explicate corect doar prin aplicatii fizi- se numeste constanta T2, de asemenea dependents de inten-
co-matematice ce nu pot fi expuse pe scurt. Pentru o intelegere sitatea campului magnetic si de structura substantei. Scaderea
practica a fenomenelor, eel mai adesea sunt folosite modele T2 este mai rapida decat cresterea Tl datorita interactiunii
mecanice care incearca sa transpuna in intelegere fenomenele dintre protoni. cu defazarea lor in toate directiile planului xy,
cuantice. General vorbind, imagistica de rezonanta magnetica ,,in evantai". Pentru a putea fi masurata in planul xy, valoarea
este o spectroscopie de protoni. Protonii atomului de hidrogen vectorului trebuie ..reamplificata". Acest lucru se face prin
sunt alesi pentru ca reprezinta eel mai abundent element din aplicarea unui impuls de radiofrecventa ,,de 180 grade" care
corpul uman, fiind prezenti in moleculele de apa, apa alcatu- readuna vectorii defazati in planul xy spre un vector unic, cu
ind 70% din structura umana. Protonul este singura particula aparenta recrestere a valorii, ca un ecou al primei excitatii.
subatomica ce prezinta atat masa, cat si sarcina, electronul Timpul scurs intre excitatia la 90 grade si reaparitia ecoului se
avand masa neglijabila iar neutronul fiind electric neutru. numeste timp de ecou TE. Se pot efectua un numar succesiv
Protonii prezinta miscare de rotatie in jurul propriei axe, de refazari, fiecare cu ecoul sau, dar valoarea fiecarui ecou
spre dreapta sau spre stanga, miscare numita spin. Fiind o este mai mica decat a celui precedent, pana ecoul devine
particula in miscare, protonul incarcat electric genereaza in nemasurabil. In acel moment, intregul ciclu se poate repeta,
jurul sau un camp magnetic (orice sarcina electrica in miscare prin o noua excitatie la 90 grade urmata de o succesiune de
genereaza camp magnetic - principiul dinamului sau al moto- ecouri. Timpul scurs intre aceste doua excitatii de 90 grade
rului electric). Protonii din structurile biologice au axele de se numeste timp de repetitie TR.
spin asezate in toate directiile spatiului, aleator. TR cuprinde evident un numar de TE, TR fiind mai lung
Introducerea unui corp biologic intr-un magnet foarte decat TE de cateva ori. Atat TE cat si TR sunt variabile mo-
puternic, de peste 0,23 Tesla (T), de regula 1, 1.5,3 sau 7 T dificabile de catre examinator. Atunci cand valoarea lor este
obliga toti micii magneti reprezentati de protonii in miscare aleasa astfel incat TE si TR sa fie scurti, imaginea va fi con-
sa se alinieze de-a lungul campului magnetic al magnetului struita predominant pe baza constantelor Tl ale structurilor
puternic. Aceasta aliniere dureaza un interval scurt de timp, examinate, fiind numita,,secventaponderata Tl". DacaTE
la finalul caruia toti protonii sunt aliniati, structura examinata si TR sunt ambele lungi, imaginea obtinuta va fi generata
fiind magnetizata. preponderent pe baza constantei T2 a substantei, o astfel de
Pozitia in spatiu a vectorului protonului poate fi definita secventa numindu-se ,,secventaponderata T2".
prin cele trei axe carteziene, x,y si z. Axa z este cea a campului Stabilirea unui TR lung dar a unui TE scurt va genera o
magnetic principal, planul xy fiind perpendicular pe acesta. imagine care depinde esentialmente de densitatea de protoni
O structura magnetizata complet va avea vectorul oriental in a substantei, secventele fiind numite „secvente de densitate
totalitate (maxim ca valoare) pe axa z, astfel meat valoarea protonica - PD".
vectorului in planul xy va fi 0. Secventele clasice in ponderate Tl, T2 si PD se numesc
Se aplica o unda de radiofrecventa asupra structurii, secvente de spin, fiind generate in special de spinul protonilor.
calculata astfel ca protonii sa fie ,,dezechilibrati", inclinati Echipamentul de rezonanta magnetica este compus
la 90 grade fata de axa z, pana cand vectorul devine maxim din magnetul principal sub forma cilindrica sau ,,C" (la
in planul xy si nul pe axa z. Un asemenea impuls la 90 grade sistemele deschise), in care este introdus pacientul. In jurul
va aduce vectorul suma al tuturor protonilor complet in axul zonei examinate se aseaza o bobina de radiofrecventa, numita
xy. Daca impulsul de 90 grade inceteaza, protonii vor reveni de regula ,,antena". Rolul acesteia este de a emite pulsurile
treptat de-a lungul axei z si vor scadea ca valoare in planul de radiofrecventa necesare bascularii la 90 si 180 grade a
24 Radiologie imagistica medicala

protonilor (sau la alte unghiuri in secvente speciale - steady Semnalul cules sub forma de radiofrecvente nu poate fi
state - unghi Ernst), dar si pentru receptia semnalului emis folosit direct pentru producerea unei imagini, acest semnal
de protoni in cursul revenirii pe axa z, care este baza datelor fiind prelucrat matematic complex, sub forma transforma-
de formare a imaginii. rilor Fourier rapide. Acestea creaza in plan un spatiu numit
In acelasi timp, in interiorul magnetului exista cateva spatiu K, in care frecventele sunt distribuite din centru catre
bobine cu rol special, si anume bobinele de gradient (trei la periferie. Formarea imaginii este similara cu cea a imaginii
numar, in cele trei directii spatiale), acestea putand fi folosite foto, in care fiecare punct de pe suprafata lentilei participa
pentru obtinerea unor secvente speciale numite ,,secvente de la formarea imaginii finale. Spatiul K confine datele brute,
gradient", mult mai rapide decat cele de spin. care, transformate matematic, devin imaginea finala. Fiecare
Bobinele interne de la capetele tunelului magnetului au punct al spatiului K participa la toate sectiunile unei secvente,
directie opusa a circulatiei curentului, in sens orar, respectiv astfel incat orice artefact (de ex. de miscare a pacientului) se
antiorar. Datorita faptului ca reprezinta bobine prin care va propaga in toate sectiunile secventei.
circula curent, ele devin electromagneti, ce vor genera camp Daca impulsul initial este diferit 90 si de 180 grade, defa-
magnetic la capetele tunelului. Cele doua bobine produc zarea protonilor este mare, pana in partea opusa directiei axei
camp magnetic opus, care se anuleaza reciproc in centrul z a campului magnetic. Revenirea este mai lunga (secventele
tunelului, singurul loc in care valoarea campului magnetului de acest tip sunt mai lungi), insa utilitatea consta in faptul
este cea nominala, de ex de 1,5 T. Pe masura ce ne indepar- ca de la opozitia fata de directia z fiecare tip de substanta va
tam de centru, spre un capat valoarea T creste treptat, prin traversa la un moment dat planul xy, avand semnal nul in acest
adaugarea valorii bobinei la valoarea nominala. In partea moment. Daca culegerea de date se face EXACT in momentul
opusa, valoarea scade treptat sub valoarea nominala. Astfel, cand o anumita substanta (apa, grasime) este pe linia de 0,
in interiorul tunelului avem de fapt o ,,panta" de gradient, aceasta nu va genera semnal, putand fi scoasa (,,stearsa") din
valorile fiind diferite la fiecare centimetru. Acest lucru este imagine. Acest principiu sta la baza secventelor de inversi-
util pentru a putea selecta ,,felia de unde se face achizitia". une-recuperare (IR). Atunci cand apa este anulata aceste
Daca intensitatea campului ar fi constanta in intregul tunel, secvente se numesc generic secvente FLAIR (Fluid Atenuated
toti protonii excitati ar vibra in acelasi timp, ar emite semnal Inversion-Recovery) iar cand grasimea este atenuata sunt
in acelasi timp si nu am putea stabili localizarea sectiunii de numite STIR (Short Time Inversion Recovery).
interes din care provin semnalele.
Ecuatia Larmor, co=YB, unde co este frecventa de
rezonanta, Y constanta si B - intensitatea campului magnetic,
stabileste relatia intre rezonanta protonilor s.i intensitatea
14. Principiile de realizare si principalele
campului magnetic. De vreme ce B este diferit in diversele aplicatii diagnostice pentru secventele
puncte ale magnetului, la o anumita radiofrecventa emisa vor IRM conventional (T2, Tl, STIR,
rezona doar protonii de la o valoare fixa a B, realizand planul
feliei de sectiune, restul protonilor, aflati la alte valori de B ne- FLAIR, alte secvente de inversiime-recu-
rezonand, si deci neemitand radiofrecvente colectabile. Pentru perare, T2 star (T2*) si susceptibilitate);
obtinerea de felii succesive, se emite radiofrecventa diferita
pentru fiecare felie, cea corespunzatoare campului magnetic
aspectul tesuturilor, organelor si a proce-
din zona feliei de examinat. O succesiune de excitatii cores- selor patologice in aceste secvente
punzatoare unei succesiuni de intensitati de camp magnetic Adrian Santa
B duce la obtinerea unei succesiuni de sectiuni.
Daca toti protonii dintr-o ,,felie" ar fi identici in rezonanta,
s-ar putea stabili planul in care se afla, dar nu si pozitia in Tomografia computerizata, poate masura valori absolute
plan (sus, in stanga, dreapta etc). De aceea, pe langa codarea de densitate (de absorbtie a radiatiei X), putand caracteriza
in frecventa, se aplica si o codare in faza a protonilor, acestia densitometric structurile evidentiate pe baza unitatilor Houn-
fiind usor decalati in faza, incat locul lor sa fie detectat cu sfield. Acest lucru nu este posibil in rezonanta magnetica.
precizie si in plan. Acest lucru este realizat de bobinele de De aceea, caracterizarea unei substante ca fiind apa,
gradient, care defazeaza protonii intre ei in functie de pozitia grasime, os, sange etc. necesita evaluarea acestei structuri
lor fata de bobine. Astfel, structurile din volumul de felie exa- in mai multe tipuri de secvente, atat ponderate Tl, cat si T2,
minat pot fi asezate exact la locul lor in planul de sectiune. STIR sau FLAIR. Pentru o buna apreciere este obligatorie
Capitolul 1. Principii ale tehnologiilor imagistice

cunoasterea comportamentului general al diverselor structuri astfel incat hipersemnalul T2 sau PD sa fie general exclusiv
in aceste secvente. de catre edemul muscular sau osos.
Astfel, grasimea este in hipersemnal (alba) atat in Saturatia grasimii este regula si in examinarile cu contrast.
secventele Tl cat si T2, in timp ce apa este in hipersemnal Acestea se efectueaza intotdeauna in secvente ponderate Tl
T2 si hiposemnal Tl. Pentru a le diferentia, este nevoie ca datorita paucitatii structurilor patologice cu hipersemnal Tl
aceeasi structura sa fie vizualizata atat in Tl cat si in T2. De (melanina, sange vechi, calciferi fine). Astfel, doar substanta
asemenea, in secventele STIR, grasimea alba in Tl si T2 va de contrast captata va fi in hipersemnal, hipersemnalul T1 al
aparea in hiposemnal. La fel, apa va deveni hiposemnal in grasimii fiind inhibat prin secvente STIR sau secvente specia-
secventele FLAIR, ajutandu-ne la incadrarea structurala a le, cu saturatie spectrala (se emite un semnal preexaminare cu
elementelor din imagine si la identificarea caracterului aces- frecventa precisa ce satureaza grasimea, astfel incat aceasta
tora (fluid, lipidic etc). sa nu emita semnal).
Exista putine structuri care prezinta hipersemnal Tl. intre Un aspect aparte il constituie corticala osoasa si cal-
acestea fiind grasimea. melanina (retrohipofiza este hiper- cifierile dense. Lipsa apei la acest nivel duce implicit la
semnal Tl), unele calcifieri si sangele extravazat cronic. cu lipsa protonilor, astfel ca lipsa rezonatorilor duce la lipsa
transformare in methemoglobina. de semnal. Aceste structuri sunt complet negre in imaginile
Evolutia semnalului sangelui parcurge mai multe eta- 1RM, fara semnal. Spongioasa osoasa prezinta semnal dato-
pe, in functie de transformarea moleculelor ce contin fier rita continutului intertrabecular de maduva rosie, galbena si
din hemoglobins in oxihemoglobina, deoxihemoglobina, elemente figurate.
methemoglobina si in final hemosiderina. Fiind un element Secven|ele de opozitie de faza (In-Out of phase) sunt
paramagnetic, fierul se comporta diferit la RM in diferitele formate din perechi de secvente construite astfel incat primul
sale stadii de degradare. set sa genereze o imagine in care semnalul apei si al grasi-
In prima etapa de sangerare supraacuta. hemoglobina mii sa se sumeze (secventele in faza), in timp ce in setul al
prezinta in T1 semnal intermediar, atat central, cat si periferic. doilea (in opozi|ie de faza) cele doua sa se substraga. Daca
In T2, sangele proaspat prezinta hipersemnal, uneori cu halou cantitatea de apa si grasime este identica, semnalul structurii
in hipersemnal periferic (edemul adiacent) si hiposemnal se va anula. Astfel o asemenea structura va fi hipersemnal in
central, facand dificila identificare sa ca atare. secventele in faza si intens hiposemnal in opozitia de faza.
In faza urmatoare, acut-subacut precoce, semnalul in Aceste secvente se dovedesc utile in examinarea acelor
secventele Tl si T2 este asemanator, in izo-hiposemnal cu structuri care in mod fiziologic au cantitati similare de apa si
tesutul adiacent (cerebral, muscular). grasime intracelulara si in care elementul patologic disrupe
Faza cronica se prezinta in secventele T1 ca hipersemnal acest echilibru. Coloana vertebrala si suprarenalele benefi-
iar in secventele T2 ca hipersemnal cu fin halou periferic ciaza in special de aceste secvente, patologia vertebrala fiind
negru, datorat depunerii de hemosiderina. Tardiv, Tl devine evidentiata datorita inlocuirii structurii normale cu structuri
semnal intermediar, in timp ce T2 pastreaza hipersemnal si patologice (apa = edem, metastaze = tesut cu alte proportii de
halou hemosiderinic periferic negru. apa si grasime). Astfel, patologia inflamatorie sau tumorala va
Detectia produsilor de degradare hematica este mai usoara fi vizibila in secventele in opozitie de faza ca hipersemnal, in
in secventele de gradient (T2* sau in secventele de suscep- timp ce structurile vertebrale normale vor deveni hiposemnal
tibilitate magnetica - SWI), in care datorita proprietatilor prin contracararea reciproca a apei si a grasimii. in cazul
sale magnetice hemoglobina degradata se prezinta in intens suprarenalelor, adenoamele nesecretante prezinta dramatica
hiposemnal chiar si la cantitati mici, inlesnind detectia mi- scadere de semnal in opozitie de faza fata de secventele in
crohemoragiilor, a leziunilor traumatice axonale difuze sau faza (contin cantitate mare de lipid intracelular), in timp ce
a malformatiilor arterio-venoase mici. tumorile si determinarile secundare raman cu hipersemnal
Secventele FLAIR au utilitate majora in evaluarea pato- (nu au grasime care sa anuleze apa).
logiei substantei albe cerebrale, in aceste secvente fluidul in ceea ce priveste aspectul si comportamentul nenuma-
fiind atenuat (in hiposemnal), in timp ce glioza si ariile de ratelor procese patologice in secventele IRM, acesta va fi
demielinizare raman in hipersemnal, putand fi caracterizate detaliat la fiecare patologie in parte, fiind prea vast pentru
ca atare si deosebite de lacune ischemice, chiste sau spatii acest capitol.
Virchow-Robin dilatate.
Este util ca, in special in examinarea aparatului muscu-
lo-scheletal, sa se foloseasca secvente cu saturatia grasimii,
Radiologie imagistica medicald

15. Tehnologia secventelor de angioRM raman nemodificate intre cele doua faze, astfel incat pot fi
substrase, lasand doar semnal la nivel circulant si obtinandu-
(TOF si angioRM cu contrast); deosebiri- se o angiograma. Avantajul PC fata de TOF consta in faptul
le dintre TOF, contrast de faza si contrast ca PC reprezinta rezultatul substractiei a doua imagini codate
diferit, eliminand astfel unele artefacte ca cele generate in
intravenos in angiografia RM; avantajele
TOF de protonii cu traiect oblic.
si dezavantajele mediilor de contrast Atat TOF cat si PC pot fi prezentate ca sectiuni 2D sau
folosite in angiografia RM; avantajele si reconstruct!! MIP 3D. Este de dorit ca interpretarea patologiei
sa tina cont intotdeauna de imaginile 2D (sectiuni in plan)
dezavantajele angiografiei RM, compara- si sa nu se bazeze exclusiv pe cele 3D, frumoase, dar ce pot
tiv cu alte tehnici; principiile contrastului ascunde patologii de mici dimensiuni.
Angiografia cu contrast i.v. este similara cu angioCT,
RM dinamic injectarea de contrast fiind facuta rapid, pe injectomat,
Adrian Santa examinarea fiind corelata cu injectarea, iar secventele de
achizitie fiind rapide, pentru a surprinde contrastul in vase.
Evaluarea angiografica in RM poate fi efectuata prin mai Dezavantajele tin de complexitatea aparatului - secvente ul-
multe metode, unele care nu folosesc substante de contrast trarapide pentru a obtine arteriografii dar si de invazivitatea
(TOF - Time Of Flight) si Contrast de faza (PC - Phase si expunerea pacientului la accidente sau incidente legate de
Contrast), respectiv unele care, in mod similar computer- contrast. Avantajele sunt posibilitatea de obtinere de secvente
tomografiei, folosesc administrarea de contrast intravenos ,,cinematice" si de rezolutia mai buna, cu vizualizare de vase
si secvente rapide, ce surprind substanta de contrast la nivel mici si lipsa artefactelor de TOF la viteze lente de curgere.
vascular. In acelasi timp, existenta unor secvente Tl rapide, de
Secventele TOF, utilizate frecvent la evaluarea 12-18 secunde (Dixon) permite evaluarea dinamica a com-
vascularizatiei cerebrale si carotidiene (structuri care nu se portamentului de contrast postinjectare. Metoda consta in
misca semnificativ in timpul achizitiei de date), au ca princi- efectuarea unei secvente rapide Tl nativa, urmata de serii de
piu intervalul de timp dintre excitatie si culegerea semnalelor secvente succesive Tl postadministrarea de contrast pe injec-
de radiofrecventa. Prin faptul ca excitatiile sunt foarte scurte, tomat, coroborata cu pasajul contrastului prin vascularizatia
protonii stationari nu pot recupera magnetizarea (nu au timp), organului examinat. Modul de evaluare a maselor hepatice
negenerand semnal. Protonii in miscare prezinta saturatie este descris in capitolul VII (contrast digestiv). In acelasi
variabila, dar prezenta, generand semnal. Codarea acestora mod, orice structura patologica poate fi evaluata dinamic
si substractia structurilor imobile din jur permite obtinerea (mase mamare, hipofizare etc).
unei imagini ,,arteriografice" sau venografice, fara utilizare de In structurile biologice normale, incarcarea si spalarea
contrast. Avantajul este buna toleranta, lipsa invazivitatii, in contrastului din tesuturi se face cu incarcare progresiva
timp ce dezavantajele sunt legate de durata mare de achizitie lenta si spalare tardiva lenta. Structurile cariokinetice, prin
si de rezolutia mai scazuta la nivelul vaselor mici. Fluxul vascularizatia abundenta si de tip endotelial prezinta o incar-
lent poate face ca doar o parte din hematiile excitate sa fie care rapida (Wash-in) urmata de o spalare la fel de rapida
inlocuite, cu aparitia de semnal intermediar ce poate duce la (Wash-out).
confuzii diagnostice cu tromboze vasculare. Prin saturarea Softul de evaluare IRM cuprinde asa numitele curbe
unei directii fata de alta, se pot substrage semnalele prove- intensitate-timp, in care progresia intensitatii de incarcare
nind de la artere sau de la vene, obtinandu-se arteriografii se coreleaza cu durata evaluarii dinamice. Se considera ca
sau venografii. malignitatile au indeobste wash-in rapid si wash-out rapid
Contrastul defaza (PC) se bazeaza pe diferenta de defa- (curba cu panta rapid crescatoare si rapid descrescatoare), in
zare intre protonii circulanti si cei stationari. Se obtine prin comparatie cu tesutul indenin care prezinta curbe cu wash-in
utilizarea a doua secvente de gradient: una cu un gradient mai lent si cu crestere lenta si in timpii tardivi sau ramanere
de defazare care maximizeaza dispersia de faza datorata in platou constant. Astfel se pot diferentia cele doua entitati,
fluxului rapid al hematiilor. Se obtine astfel o imagine cu un aducand infonnatii suplimentare despre natura leziunilor.
hiposemnal intravascular net. A doua achizitie se face cu un
gradient de defazare a fluxului ce genereaza un hipersemnal
in vasele cu flux rapid. Toate celelalte structuri extravasculare
Capitolul 1. Principii ale tehnologiilor imagistice 27

16. Principiile imagisticii de difuzie si a permanent exista o components de hipersemnal determinate


de T2 al apei, si al hipercelularitatii.
imagisticii de difuzie tensoriala Cu cat b creste, semnalul apei scade, fenomen cunos-
Adrian Santa cut sub numele de T2 shine-through. Desi deranjant in
diagnosticul diferential intre apa si tesut dens celular, T2
shine through este util in stabilirea caracterului lichidian
Bazele imagisticii prin difuzie sunt legate de miscarea al structurii.
browniana. In diversele structuri ale corpului uman, mole- Pentru a elimina efectul T2 al apei, se folosesc coeficienti
culele de apa se pot misca diferit, in func|ie de structure care calculati care reduc sau elimina efectul T2; acestia sunt ADC
le gazduieste. Astfel, structurile cu celularitate laxa permit si ACL
miscari ample ale moleculelor de apa, in toate directiile ADC (Apparent Diffusion Coeficient) - coeficientul apa-
spatiului, miscare numita anizotropica (in toate directiile) si rent de difuzie. Acesta se calculeaza din minimum doua valori
nerestrictiva (grad mare de libertate). Structurile cu impache- diferite ale b (ex: b 50 si b 800), structurile restrictive avand
tare celulara densa limiteaza gradul de miscare a moleculelor hiposemnal in ADC in timp ce apa ramane in hipersemnal,
de apa, fara a le ordona Jntr-o directie, rezultand o miscare diferentiind cele doua entitati.
anizotropa, dar restrictionata (grad redus de miscare). Celu- AC1.(Exponential Coefficient sau Attenuation Coefficient)
lele Schwann ale axonilor orienteaza miscarea moleculelor este un calcul care elimina complet efectul T2 al apei. Struc-
de apa de-a lungul tractelor axonale, rezultand o miscare turile in hipersemnal ACI sunt restrictive si nu fluide.
restrictionata si izotropica, in directia axonilor. Utilitatea secventelor de difuzie rezida in caracterizarea
Secventele de difuzie exploateaza miscarea anizotropa catorva elemente care restrictioneaza miscarea apei.
(restrictionata sau nu), in timp ce secventele de difuzie ten- Infarctul cerebral acut, prin edemul citotoxic, este re-
soriala exploateaza miscarea izotropa. strictiv (edemul vasogen, nu!), permitand evaluarea ariei de
Secventele de difuzie = secvente T2, cu doua impulsuri afectare cerebrala in infarctul acut. Imaginile sunt pozitive
suplimentare de gradient, unul inainte si altul dupa o refazare la interval de cateva minute de la debutul ictusului, fiind
la 180 grade - gradienti sensibili la miscare. valoroase in diagnosticul precoce si, combinate cu perfuzia,
Codarea difuziei (Stejskall-Tanner) - cu cat moleculele permit diferen^ierea centrului infarctat (core) de periferia
de apa sunt mai imobile intre cele doua impulsuri de gradient ischemica dar reversibila (penumbra), permitand recuperare
senzitive de miscare, cu atat semnalul receptionat este mai de tesut cerebral.
puternic -moleculele de apa raman aproape nemi^cate, suma Tesuturile maligne cariokinetice, prin dezvoltarea aberan-
semnalului lor fiind inalta - restrictie marcata a miscarii apei. ta si rapida a celulelor, inghesuite in packing celular dens,
Daca moleculele de apa se misca rapid, pozi|ia initiala a mole- sunt de asemenea restrictive, permitand detectia tumorilor
culei excitate este luata de o alta molecula de apa, neexcitata, sau a determinarilor secundare, dar si evaluarea evolutiei
suma vectorilor fiind mai mica - molecula neexcitata nu aduce acestora sub tratament.
semnal - restrictie redusa a miscarii apei Este de remarcat ca un numar de organe prezinta restrictie
Ecuatii care guverneaza fenomenul de difuzie: crescuta in mod fiziologic, acest lucru trebuind cunoscut si
S; = SQ-e"bADC - (S; - intensitatea semnalului dupa gradient, diferentiat de patologie (testicul, parotida, splina, mucoasa
S0 - intensitatea semnalului inaintea gradientului, ADC - Ap- digestiva etc).
parent Diffusion Coefficient - Coeficient de difuzie aparenta Difuzia tensoriala exploateaza izotropia miscarii apei in
in directia ,,i", toate in acelasi voxel sistemul nervos de-a lungul axonilor. Codarea in culoare si
b - factor stabilit de catre examinator reconstructia tridimensionala permite obtinerea de imagini
b = g2G2d2(D-d/e) (b depinde de intensitatea gradientilor 3D ale fasciculelor de substanta alba (spino-talamic, spino-
- G si de timpul aplicarii gradientilor - d, g fiind constanta bulbar, de asociatie etc).
giromagnetica) In patologie, se urmareste efectul structurilor patologice
b = 0 este, de fapt, o imagine T2; asupra tractelor nervoase (deviere, infiltrare, intrerupere sau
cu cat valoarea b este mai mare, cu atat difuzia este respon- chiar lipsa), cu rol important in terapia chirurgicala, dar si
sabila de intensitatea semnalului, in detrimentul efectului T2. in diagnostic.
In mod teoretic, la valori mari ale b (b=800 sau 1000), Constatarea ca exista izotropie si de-a lungul fibrelor mio-
structurile care pastreaza hipersemnal sunt structurile re- cardice sau a structurilor tubulare renale duce la posibilitatea
strictive. In realitate, datorita valorii T2 mari a apei, de fapt obtinerii de imagini 3D a acestora prin tractografie.
28 Radiologie imagistica medicala

17. Principiile rezonantei magnetice 18. Principiile spectroscopiei RM


functionale (fMRI) prin folosirea con- utilizand 1H, 31P, 13C
trastului BOLD (dependent de nivelul de Adrian Santa
oxigen sanguin)
General vorbind, un aparat de rezonanta magnetica este
Adrian Santa un spectroscop. Imaginile IRM sunt rezultatul prelucrarii
matematice a unor informatii spectroscopice transformate in
Evaluarea functionala a sistemului nervos central are la imagine. In acelasi timp, un aparat de rezonanta magnetica
baza metabolismul oxigenului la nivelul celulei nervoase. poate analiza cantitatea diferitelor substante prezente in aria
Ca regula generala, grupurile de neuroni care ,,lucreaza" examinata, afisandu-le ca un grafic de varfuri (Peak) cores-.
impreuna consuma mai mult oxigen in starea activa decat in punzand diverselor substante prezente in acel esantion. Diver-
repaus. Modificarea cantitatii de oxigen in zonele activate se molecule abundent prezente in structurile corpului uman,
(prin stimuli senzoriali - imagini proiectate sau motorii - prin care prezinta numar atomic impar (1H, 31P si 13C), prezinta
efectuarea de catre pacient a unor anumite miscari) poate fi atat miscare de spin, cat si moment magnetic, constituindu-
detectata IRM. Originea modificarilor consta in faptul ca se in mici magneti ce pot fi analizati RM. Graficul spectral
starea magnetica a hemoglobinei difera in functie de tipul reprezinta intensitatea semnalelor RM versus intensitatea
de molecula (oxigenata sau nu). Modificarile in saturatia campului magnetic referite la un standard (TMS -tetrametil
de oxigen a hemoglobinei produc modificari ale semnalului silan) si exprimate in ppm (parts per million). Fiecare tip de
MR, asa numitul efect BOLD (Blood Oxygenation Level- atom sau molecula vibreaza la frecvente diferite. Fenomenul
Dependent). De fapt, fMRI nu masoara activitatea neuronala se numeste chemical shift (CS) si se defineste ca frecventa
in sine ci raspunsul la cresterea oxigenarii ariilor activate semnalului receptionat minus frecventa de referinta (TMS)
prin modificarea concentratiei de hemoglobina deoxigenata supra frecventa spectrografului si inmultit cu 106. Originea
(care la randul sau este dependents de fluxul cerebral (CBF- fenomenului de chemical shift rezida in gradul de ,,ecranare"
Cerebral Blood Flow), de volumul sanguin cerebral local a nucleului moleculei de catre electronii din jur, gradul de
(CBV - Cerebral Blood Volume) si de rata metabolica de ecranare este diferit pentru diferite tipuri de molecule, ducand
oxigen cerebral (CMRO2 - Cerebral Metabolic Rate of O2). la comportament magnetic diferit.
Zonele metabolic active necesita oxigen mai mult, mai multa Spectroscopia HI (protonica). Datorita abundentei de
glucoza si ,,spala" CO2 mai repede. protoni in corpul uman, spectroscopia de protoni este cea mai
Pentru a obtine un raspuns coerent la stimuli scurti si folosita. permitand evaluarea oricarei structuri ce contine pro-
pentru a-i compara cu starea de inactivitate, sunt necesare toni. In functie de modul de legare a protonilor in molecula,
secvente foarte rapide, de tipul ecourilor de gradient echo- respectiv de gradul de ecranare produs de electroni asupra
planare (EPI - Echo-Planar Imaging). nucleului atomic, valorile chemical shift ale moleculelor cu
Prin substractia aspectului in repaus si in activitate se pot continut protonic sunt diferite, astfel ca peak-urile lor vor fi
suprapune peste imaginile EPI anatomice ,,harti" de culoare situate la distante diferite pe graficul spectral, permitand atat
care evidentiaza zonele in care consumul de oxigen si glu- identificarea lor, cat si masurarea cantitatii lor in esantionul
coza a crescut. Aceste harti parametrice sunt comparate atat examinat.
cu statusul in repaus si in stimulare, cat si stanga-dreapta. In practica medicala, spectroscopia este utilizata pentru
permitand obtinerea de concluzii despre hiperactivitate sau a stabili cantitatea unor molecule anume in esantionul dat.
hipoactivitate la nivelul ariei cerebrale evaluate, respectiv Pozitia pe graficul spectral (in ppm) defineste TIPUL de
despre activari diferite de cele normale (alte zone cerebrale molecula, iar inaltimea peak-ului defineste CANTITATEA
decat cele fiziologice). acestei molecule. Plecand de la observatia ca exista raporturi
Este de mentionat ca examinarea fMRI este de lunga fixe intre diversi metaboliti la nivelul diverselor structuri
durata si ca este intens artefactata de miscarile capului paci- biologice, modificarea raportului intre ele sau absenta unora
entului, de temperatura ambianta din tunelul magnetului si care sunt in mod normal prezente respectiv aparitia unora care
de un numar de factori intrinseci, facand examinarea labo- nu ar trebui sa fie acolo, dau relatii valoroase despre tipul de
rioasa si foarte pretentioasa in ceea ce priveste conditiile de patologie examinata.
examinare. Astfel, in creierul uman, raportul intre Cholina (Cho) si
N-Acetil-Aspartat (NAA) este in favoarea NAA. Inversarea
Capitolul 1. Principii ale tehnologiilor imagistice 29

inaltimii peak-urilor in favoarea Cholinei, cu valori NAA sub Artefacte de hardware si aparat RM
cele de Cholina este specifics proceselor maligne. Aparitia - Artefact herring bone (apare pe o singura sectiune sau
unui Peak inalt dincolo de NAA este specifica prezentei de mai multe, ca o imagine de ,,os de peste" pe intreaga imagine).
Lactat, caracteristic necrozei celulare. Cauzat de discrepante in pulsurile RE, alimentare cu curent
La fel, tesutul normal prostatic contine un metabolit fluctuant sau descarcari electromagnetice ale bobinelor de
numit Citrat. Tumorile maligne prostatice nu contin citrat. gradient)
evidentierea lipsei acestuia intr-o zona suspecta a parenchi- - Margini Moire (suprapunere a unei parti a corpului pes-
mului prostatic este evocatoare pentru malignitate prostatica. te cealalta. cu aspect de banda dubla), cauzat de interference
Exista posibilitatea evaluarii graficului spectral intr-un in secventele de gradient datorate neomogenitatii campului
singur voxel plasat in zona lezionala (Single-Voxel Spectro- magnetic stg-dr.
scopy) sau posibilitatea asezarii unei ,,harti" de voxeli situati - Artefact zebra - benzi alternative alb-negru cauzate de
in acelasi plan, cu grafic analizat in fiecare voxel (Multi- varfuri in spatiul k.
Voxel Spectroscopy). SVS este utila pentru evaluare precisa - Artefact depunct central - imagine de punct hipersem-
(Ex peretele gadolinofil al unei mase cerebrale cu centru nal in centrul imaginii. cauzat de modificari ale curentului in
negadolinofil). in timp ce MVS este utila atunci cand trebuie receptor. Poate cauza confuzii cu patologie.
comparate arii situate simetric (prostata, creier etc). - Artefact zipp - imagine de banda in zig-zag unica
Spectroscopia 13C (carbon 13). Avand chemical shift sau multipla in toate imaginile unei serii, perpendicular pe
exprimat si 13C poate fi utilizat pentru identificarea prezentei directia de codare, cauzat de interferenta cu alte surse de
si cantitatii diverselor molecule in corpul uman. Deoarece radiofrecventa ce patrund in scanner prin usa deschisa sau alte
izotopul 13C este in cantitate mica in corpul uman, de regula probleme de hardware - atunci cand persista si cu us. a inchisa.
se administreaza pacientului glucoza cu 13C, putandu-se MR software
obtine astfel informatii in vivo despre metabolismul celular. In - Suprapunere de sectiuni (artefact cross-talk) - banda de
evaluarea cerebrala, spectroscopia 13C permite evaluarea mo- pierdere a semnalului de regula posterioara, cu suprapunere de
leculelor de glucoza si glicogen, metabolismul acestora, dar felii atunci cand achizitia acestora nu este paralela, in al doilea
si alte date legate de metabolismul oxigenului (prin evaluarea slack (grup) patrunzand protoni excitati din prima secventa.
glutamatului, malat-aspartat, turn-over al glutaminei), toate - Artefacte cross-excitation - reducere a semnalului
oferind date despre functionalitatea celulei nervoase cerebrale. intr-o zona datorita prezentei partiale de protoni excitati din
Spectroscopia 3IP. Metabolitii ce contin fosfor detectabili sec|iunile precedente - de aici obligativitatea de a avea spatiu
prin spectroscopia 3 IP, cum ar fi adenosin trifosfat (ATP), intre sectiuni - gap.
fosfocreatina (PCr), fosfat anorganic (Pi), fosfomonoesteri Miscarea pacientului sau a organelor sale interne
(PME), si fosofodiesteri (PDE), ofera informatii valoroase - artefact de miscare in directia de codare a fazei -
despre pH-ul intracelular, metabolismul energetic celular imagini imprecise, cu ecouri in jur si dedublari cauzate de
respectiv metabolismul fosfolipidic. miscarile pacientului, inghitire, respiratie sau peristaltica;
Aplicatiile uzuale se refera la patologica tumorala cere- artefact de intrare in sectiune - continut vascular
brala, unde rolul 31P nu este de a confirma tumora ci de a hipersemnal la inceputul unui vas, cu scadere progresiva in
diferentia intre variate tipuri de rumori, comportamentul spec- intensitate, general de spini nesaturati ce patrund in felie. Fo-
troscopic al diverselor malignitati cerebrale fiind diferit. losit pentru angiografia TOE, poate fi confundat in secventele
conventionale cu tromb intravascular.
Neomogenitati de tesut sau corpi strain!
19. Artefactele in examinarea IRM: - margine neagra - la limita intre apa si grasime sau
muschi si grasime, ca un contur negru. Cauzat de opozitia
descriere, cauze de faza intre apa si grasime prezente in acelasi pixel si este
Adrian Santa specifica in secventele de gradient.
- unghi magic - hipersemnal la nivelul unui tendon cu
Exista un mare numar de artefacte ce pot afecta exa- traiect curb in punctul in care acesta face un unghi de 54,74
minarea IRM, unele prezente in imagistica prin rezonanta grade fata de directia campului magnetic. Poate preta la
magnetica (IRM), altele prezente in spectroscopia prin confuzii cu tendinopatie.
rezonanta magnetica (MRS). Cauzele aparitiei de artefacte artefact de susceptibilitate magnetica - distorsionarea
sunt multiple, ele putand fi clasificate astfel: imaginii in jurul unei structuri cu neomogenitati magnetice
Radiologie imagistica tnedicala

marcate, de regula metalic - proteze, urme de foraj osos, - Ferromagnetic. Materiale ce contin cristale largi si soli-
clipuri etc. de cu electroni nepereche, ce prezinta "memorie" magnetica,
- artefact de shift chimic (Chemical Shift) - general de mentinand cu camp magnetic in jur dupa ce au fost expuse
difereritele intre frecventa de rezonanta a apei fata de grasime, la un camp magnetic din exterior. In aceasta categorie intra
apare in directia de codare in frecventa si apare ca doua ima- obiecte de fier, nichel, cobalt etc., toate acestea cauzand severe
gini ale aceluiasi organ, discret dezaxate - dedublate una fata distorsionari artefactuale ale campului magnetic.
de cealalta. Fenomenul este utilizat in spectroscopie RM Principii generale
Artefacte legate de transformari Fourier sau masurare Spre deosebire de radiologia conventionala si CT, in IRM
Nyquist substantele de contrast nu sunt direct vizibile dupa injectarea
- Artefact de trunchiere (Gibbs) - apare la interfata brus- lor intravenoasa si vehicularea lor in diversele organe. In
ca intre doua medii foarte diferite, sub forma de linii paralele schimb, contrastul este obtinut datorita capacitatii acestor
cu aria de interfata intre cele doua structuri, fund cauzat de substante de contrast de a scurta timpii de relaxare Tl si/sau
probleme ale transformarii Fourier in spatiul K. Poate fi T2 a nucleilor de hidrogen aflati in apropierea moleculelor de
combatut prin cresterea numarului de trepte de codare. substanta de contrast. Substantele care reduc timpul de rela-
- Artefact de umplere ,,0" - benzi oblice de intensitate xare Tl sunt substante PARAMAGNETICE. Ele vor genera
alternativa alb-negru, generate de lipsa de date in cursul hipersemnal Tl in imediata lor vecinatate. Substantele care
scanarii in anumite puncte ale spatiului K. reduc timpul de relaxare T2 sunt substante SUPERPARA-
- Artefact de Aliasing (de impachetare) - ,,taierea" margi- MAGNETICE, ele reducand relaxarea T2 si T2*.
nala a unei structuri cu reaparitia sa in zona opusa a imaginii Clasificare:
- impachetare. Cauzata de camp de examinare - FOV mai mic Exista doua mari grupe de substante de contrast:
decat zona examinata. - chelati de Gadolinium, care sunt paramagnetici si care au
ca principal efect generarea de hipersemnal in secventele Tl;
- particule de ferita, care sunt superparamagnetice, deter-
20. Indicatiile de folosire a substantelor minand scaderea semnalului T2 si T2* (SPIO - Small Particle
respectiv USPIO - UltraSmall Particle).
de contrast RM in studiul diverselor Chelatii de Gadolinium.
organe si sisteme; contraindicatiile ab- Considerate substante de contrast de uz general, acestea
sunt injectate i.v. si distribuite de torentul sanguin in toate
solute in IRM; modalitati de examinare structurile vasculare.
a pacientilor cu contraindicatii relative; In functie de fluxul sanguin si gradul de vascularizare,
notiuni de siguranta in relatie cu mediul de permeabilitatea si tipul vaselor structurilor examinate, se
ob|ine un contrast crescut, sub forma de hipersemnal Tl.
RM in ceea ce priveste pacientii si per- Evaluarea se face intotdeauna in secvente Tl, dupa o
sonalul medical prealabila evaluare in Tl fara contrast, pentru a putea face
diferenta. Exista putine structuri spontan cu hipersemnal Tl
Adrian Santa (melanina, grasimea, unele calcified si sangele vechi), iar hi-
persemnalul grasimii este de regula suprimat prin folosirea de
Pentru a intelege modul in care ac{ioneaza substantele secvente Tl pre si postcontrast cu saturatia grasimii (TIPS).
de contrast in IRM, este necesar de a cunoaste proprietatile, Modul de apreciere a modificarilor postcontrast este vari-
respectiv comportamentul diverselor substante in campul at, uneori fiind suficienta demonstrarea incarcarii cu contrast
magnetic. Comportamentul poate fi clasificat astfel: (ex: tumori osoase versus alte patologii osoase nevasculare
- Diamagnetic. Apa este considerata slab diamagnetica sau tumori cerebrale, metastaze etc). Alteori, este necesara
- Paramagnetic. Materiale sau structuri ce conpn numar aprecierea comportamenrului la contrast in diferite faze ale
impar de electroni, astfel concentrand local fortele magnetice tranzitului de contrast prin organe, evaluare numita contrast
si crescand astfel campul magnetic local (susceptibilitate dinamic.
magnetica crescuta). Indicatiile contrastului dinamic se refera la comportamen-
- Superparamagnetic. Materiale sau structuri ce con|in tul unor structuri in faza precoce (,,arteriala"), in faza tardiva
particule cu susceptibilitate magnetica mult mai mare decat (,,venoasa") sau in faza de echilibru, si mai tardiva. Metoda
cele paramagnetice. Aici intra microparticulele SPIO. este utila in evaluarea maselor pancreatice sau hepatice, di-
Capitolul 1. Principii ale tehnologiilor imagistice 31

versele tipuri de mase avand comportament diferit (vezi cap lor, clipurilor de colecistectomie sau protezelor ortopedice
VII- substante de contrast digestive). nu migreaza, nu se incalzesc si nu pfovoaca leziuni. Totusi,
Alteori, sunt necesare mai mult de trei achizitii (10 sau mai acestea produc artefacte de susceptibilitate locala, cu degra-
multe) efectuate in succesiune rapida. la final obtinandu-se darea calitatii imaginilor.
un grafic de intensitate-timp al incarcarii. Folosita frecvent in Pacientii claustrofobi si cei de varsta pediatrica mica pot
patologia tumorala mamara si hipofizara, metoda se bazeaza fi anesteziati atunci cand exista aparat de anestezie generala
pe diferenta intre modul de incarcare si spalare a tumorilor RM compatibil si apararura de monitorizare ATI RM corn-
benigne versus maligne. Structurile maligne prezinta incar- patibila.
care rapida si spalare rapida (Wash-in si Wash-out rapide), Contraindicatiile administrarii de contrast sunt similare
in timp ce Structurile normale si benigne au Wash-in lent, cu celor din radiologia conventionala si CT, legate de functia
Wash-out lent crescator sau in platou. renala, reactii alergice etc, cu remarca ca, desi mai rare,
O alta indicatie de contrast este cea vasculara, secventele reactiile la contrast pot fi prezente si in examinarea IRM
rapide permitand efectuarea de arteriografii sau venografii. cu contrast, chiar si formele grave, de soc anafilactic sau
chiar si in secvente cinematice, cu aspect de ,,timp real". afectare renala.
O proprietate a utilizarii contrasrului se refera la patologia In relatie cu mediulinconjurator, exista precautiuni care
cardiaca, unde ariile infarctate se incarca greu in faza arteriala sunt de retinut in cadrul unui aparat RM. Astfel, in camera
si se spala greu in faza tardiva, cu remanenta hipersemnalului scannerului nu se intra cu obiecte ferometalice (de la chei la
in zona infarctata mult dupa injectare (10-12 minute), asa- targi §i carucioare pentru transport pacient) acestea riscand
numitul Late-Enhancement (incarcare tarzie). sa nu mai poata fi detasate de magnet. Obiectele mici (chei,
Contrastul superparamagnetic monede, rame de ochelari) pot fi accelerate in tunelul mag-
Substantele bazate pe microparticule superparamagnetice netului, putand provoca rani, chiar grave.
(SPIO, USP1O - Resovist) actioneaza asupra relaxarii T2*, Aparatele electromagnetice (telefoane mobile, carduri de
motiv pentru care evaluarea postadministrarea acestora se credit si chiar ceasuri electronice sau mecanice) pot fi distrase
face in secvente T2. Ultraparticulele de fier sunt fagocitate si iremediabil de catre mediul magnetic intens al scannerului.
retinute in celulele Kupfer hepatice, in timp ce Structurile pa- Piercingurile metalice, fardurile si tatuajele contin pulberi
tologice lipsite de celule Kupfer nu vor retine aceste particule. metalice, putand genera de la artefacte la arsuri.
Evaluarea se face la 10-20 min dupa injectare. Datorita celu- Este necesara precautie in asezarea antenelor (niciodata
lelor Kupfer prezente in parenchimul hepatic, in secventele direct pe tegument) si de asemenea evitarea alcatuirii de
T2 parenchimul normal va avea o dramatica reducere de arcuri (picioare incrucisate, maini impreunate), acestea pu-
semnal. Pe acest fond de hiposemnal, leziunile ce nu contin tand genera arcuri termice, cu arsuri ale pacientului, uneori
celule Kupfer vor fi in hipersemnal, mai evidente. grave. Pacientul primeste o para de cauciuc legata la sis-
Actualmente, uzul substantelor SPIO si USPIO in pato- temul de alarma audio al aparatului, pe care acesta o poate
logia hepatica a pierdut teren in favoarea celor substantelor strange atunci cand simte fenomene neplacute, cu oprirea
cu tropism hepatocitar. examinarii.
Contraindicatii absolute si relative in IRM O alta problema de rise o reprezinta externalizarea azotului
Exista unele contraindicatii absolute pentru examinarea care raceste bobina magnetului sau a heliului din componenta
IRM. acelorasi sisteme de racire. Prin lipsa lor de miros, gust sau
Contraindicatiile absolute cuprind prezenta de PaceMa- culoare, ele pot genera sufocarea pacientului sau personalului
ker la pacient, acesti pacienti nefiind admis dincolo de linia cand se acumuleaza in incapere, existand senzori cu alarmare
de 0,1 T, existand rise de deces la acest pacienti daca sunt pentru aceste situatii. Heliul racit la aproape temperatura ,,0"
expusi la campul magnetic. absolut (-270 grade C), poate ingheta distructiv sau poate
La fel, implantul cochlear, clipurile metalice arteriale sunt rani prin explozia de volum brusca, de aceea aparatele au
contraindicatii absolute. sistem automat de evacuare fortata in atmosfera a acestor
Intre contraindicatiile relative intra alte proteze, materi- gaze (Quenching tube). Tubul de evacuare se instaleaza astfel
ale medicale implantate pacientilor si despre care nu exista incat sa nu deverseze heliu in locuri circulabile.
date precise de la producator ca sunt ,,MRI-safe", adica cu
siguranta in folosirea examinarii RM.
In timp, producatorii au adaptat materialele utilizate la
cerintele IRM, astfel incat majoritatea stenturilor, sterilete-
Radiologie imagistica medicala

21. Valoarea relativa si indicatiile date legate de prezenta in miocard a unor structuri patologice
(amiloid, fibroza, lipide - in bolile aritmogene ventriculare
examinarii RM pentru diverse organe drepte). Contrastul cu incarcare tardiva permite evaluarea
si sisteme ariilor infarctate, dar si zonele de miocard ischemiate sau
stuporate, permitand recuperarea de tesut miocardic. Statiile
Adrian Santa
grafice permit evaluari volumetrice, de volume cardiace,
fractii de ejectie etc, valoroase in diagnostic.
Valoarea si indicatiile IRM sunt vaste, si vor fi discutate Abdomen
la fiecare capitol in parte. Ca regula generala, exista domenii Secventele rapide, difuzia si administrarea de contrast
in care IRM este investigatia de electie, dupa cum exista si aduc IRM in primul plan al evaluarii parenchimelor intraab-
unele m care valoarea sa este redusa. domino-pelvine, in diferentierea tipurilor de mase parenchi-
Prin lipsa de invazivitate si de expunere a pacientului la matoase si in diagnosticul precoce. Prin imaginile anatomice
radiatii ionizante, IRM este o metoda cu grad de iatrogenie detaliate, patologia pelvina (imprecis evaluabila CT sau prin
foarte redus. Datorita multimodalitatii de abordare a leziunii ecografie transabdominala), IRM este metoda de electie in
(Tl, T2, FatSat, difuzie, spectroscopie etc), IRM necesita evaluarea aparatului genital feminin (malformatii, patologie
mult mai rar administrare de contrast, reducand si mai mult benigna si maligna etc). Spectroscopia permite evaluarea re-
riscurile asupra pacientului. Contraindicatiile putine fac de giunilor prostatice fara citrat, de regula maligne. Adenopatiile
asemenea metoda intens raspandita. pot fi evidentiate cu ajutorul sectiunilor morfologice, dar si a
Sistem nervos difuziei, permitand stadializarea bolilor maligne.
Evaluarea SNC si periferic aseaza IRM in prima linie Posibilitatea realizarii colangiografiei fara contrast si a
pentru evaluarea patologiei. Performanta maxima este in urografiei fara contrast ridica metoda la varful investigatiilor
evaluarea morfologica si patologica (tumori, malformatii), abdominale.
fiind de notat ca prin aportul difuziei si perfuziei, IRM poate Posibilitatea de a realiza enteroclisis deschide posibilitatea
detecta precis si rapid accidentele vasculare, la cateva minute de evaluarea intestinului, in special subtire, greu apreciabil
de la debutul ictusului, fiind valoroasa in recuperarea tesutului prin metodele imagistice conventional si de cele mai multe
cerebral ischemic dar inca reversibil (,,time is brain"). Exista ori ocult ca patologie in situ.
protocoale de 5-6 minute pentru evaluarea AVC, putandu- Coloana vertebrala
se lua decizii terapeutice rapide si pertinente. Patologia Patologia vertebrala, in special degenerativa discala si
malformativa si traumatica cu components hematica este maligna secundara sunt de asemenea apreciate eel mai bine
evidentiata rapid prin secventele T2* si de susceptibilitate prin IRM, in timp ce in patologia traumatica. in special fine
magnetica (SWI), evidentiind leziuni altfel oculte (MAV, ca- fracturi ale arcului neural vertebral raman apanajul CT.
vernoame mici, leziuni axonale difuze neevidentiabile altfel). Musculo-scheletal
Spectroscopia poate evalua caracterul malign al leziunilor Fie ca vorbim de patologia degenerativa, traumatica sau
tumorale incerte prin modificarea raportului Cho-NAA si de maligna, IRM este metoda de electie in evaluarea aparatu-
asemenea aparitia necrozei, prin aparitia Peak-ului de lactat. lui musculo-scheletal, net superioara oricaror alte metode,
IRM functionala poate da date despre activari patologice sau evidentiind edem osos, mase osoase dar mai ales tendoane.
lipsa de activitate in diverse zone cerebrale, utila in boli ca ligamente si cartilaje, greu evaluabile sau neapreciabile
epilepsia, Parkinson si altele. Evaluarea spectroscopica 1H. altfel.
3 IP si 13C permite obtinerea de date despre functionalitatea Oncologie
metabolica cerebrala. Difuzia corporeala a intregului corp (Whole Body Diffusi-
Valoare redusa o prezinta evaluarea hemoragiilor supraa- on) permite diagnosticul pozitiv si stadializarea malignitatilor,
cute si a hemoragiei subarahnoidiene, unde rolul CT ramane fiind apropiata ca valoare de PET. Combinata cu imaginile
dominant. morfologice si evaluarile izotopice (PET-MR) are cea mai
Torace mare performan|a in acest domeniu.
Evaluarea pulmonara ramane dificila si cu rezolutie scazu- Mamar
ta in IRM, parenchimul pulmonar fiind net mai bine evaluabil Desi inca in evaluare, IRM devine o metoda de mare
prin CT. In schimb, IRM permite evaluarea mediastinului, a performanta in evaluarea patologiei mamare, in special a celei
cordului (cu obtinere de date morfologice, dinamice-cinema- maligne, abordata multimodal (morfologic, difuzie, contrast
tografice), pentru evaluarea dinamicii miocardice, precum si dinamic cu mapping si curbe intensitate-timp), caracterizand
Capitolul I. Principii ale tehnologiilor imagistice 33

precis mase mici, de peste 5 mm si intregind tabloul patologic


cu evaluarea adenopatiilor satelite.
Angiologie
Evaluarea vaselor cerebrale cu metode neinvazive (fara
contrast) prin TOP sau PC permit diagnostice vasculare fara a
adauga riscul anafilaxiei sau al nefrotoxicitatii la examinarea
imagistica.
Evaluarea cu sau fara contrast a vaselor arteriale sau
venoase si reconstructive tridimensionale aduc metoda la
nivelul CT-Angio. Ramane inca dificila evaluarea corona-
riana, dar care avanseaza odata cu nolle progrese tehnice
in domeniu.
Partea a 4-a

Ecografia (ultrasonografia)

Bibliogrqfie
1. Dudea SM - Principii fizice - in: Badea R, Dudea SM, Mircea PA, Stamatian F - Tratat de Ultrasonogrqfie clinicd, Vol.1: principii,
abdomen, obstetricd si ginecologie Ed. Medicala, Bucuresti, 2011, pag. 11-38
2. Dudea SM - Elemente tehnice ale aparatelor de diagnostic Ultrasonogrqfie - in: Badea R, Dudea SM, Mircea PA, Stamatian F - Tratat
de Ultrasonogrqfie clinicd, Vol.1: principii, abdomen, obstetricd si ginecologie Ed. Medicala, Bucuresti, 2011, pag. 39-44
3. Dudea SM - Artefacte si surse de eroare in diagnosticul Ultrasonogrqfie - in: Badea R, Dudea SM, Mircea PA, Stamatian F - Tratat de
Ultrasonogrqfie clinicd, Vol.1: principii, abdomen, obstetricd si ginecologie Ed. Medicala, Bucuresti, 2011, pag. 78-89
4. Dudea S.M., Badea R.I. - Ultrasonogrqfie vasculard. Ed. A H-a - Ed. Medicala, Bucuresti, 2009
5. Dudea SM- Efectele biologice ale ultrasunetelor - in: Badea R, Dudea SM, Mircea PA, Stamatian F - Tratat de Ultrasonogrqfie clinicd,
Vol.1: principii, abdomen, obstetricd si ginecologie Ed. Medicala, Bucuresti, 2011, pag. 56-59
6. Botar-Jid Carolina, Dudea S - Fizica ultrasunetelor - in: Fodor Daniela - Aplicatii ale ecografiei musculoscheletale in reumatologie -
Ed. Medicala, Bucuresti, 2013
7. Dudea SM. - Ultrasonogrqfie. Notiuni introductive defizica, tehnica si metodologie de examinare - in: FodorDaniela - Ecografie clinicd
musculoscheletald, Ed. Medicala, Bucuresti, 2009
Capitolul 1. Principii ale tehnologiilor imagistice 37

22. Bazele fizice ale ecografiei: undele ul- cand acesta este supus unei deformari mecanice. Fenomenul
se produce si in sens invers: un cristal piezoelectric supus
trasonore (caracteristici descriptive, ve- unei diferente de potential va suferi o deformare mecanica.
locitate, intensitate); impedanta acustica Aceasta deformare genereaza ultrasunetele.
Frecventa nominala a unui transductor. O piesa data
si proprietatile tisulare care o determina; din ceramica sintetica piezoelectrica se caracterizeaza prin
frecventa de transmisie si calitatea imagi- frecventa de rezonanta, reprezentand frecventa US emise
nii; principiile fenomenului piezoelectric, in condhiile in care conversia energiei electrice in energie
acustica se realizeaza un randament maxim. Daca o piesa
frecventa de rezonanta a elementului ceramica avand frecventa de rezonanta de 3 MHz este supusa
piezoelectric unui impuls electric cu frecventa de 3 MHz, conversia ener-
giei electrice in energie acustica se va desfasura cu eficienta
Sorin M. Dudea
maxima, rezultand, in cea mai mare parte, US cu frecventa
de 3 MHz. Frecventa de rezonanta a unei piese ceramice de-
Definirea metodei pinde de grosimea ceramicii, deci este prestabilita in cursul
Ultrasonografia (sau ecografia) (US) reprezinta o clasa de fabricarii transductorului si are valoare fixa pentru fiecare tip
examinari medicale. preponderent imagistice. care utilizeaza de transductor in parte. La aplicarea impulsurilor electrice
ultrasunetele reflectate in corpul omenesc, drept vector al rezulta un spectru de frecvente ultrasonore, in care domina
informatiei medicale cele avand valoarea frecventei de rezonanta. Acest spectru de
Definitia sunetelor. Sunetul este o vibratie mecanica a frecvente poarta numele de largimea de banda a semnalului
materiei, transmisa sub forma de unde. ultrasonor. Frecventa dominanta in largimea de banda, si
Marimile ce caracterizeaza undele sonore sunt: care are utilitate maxima in generarea imaginii ultrasonore,
- Amplitudinea (A) reprezinta deplasarea maxima a par- poarta denumirea de frecventa nominala (de transmisie) a
ticulei intr-un sens sau altul fata de pozitia de echilibru. transductorului respectiv. Cu cat frecventa de transmisie
- Perioada (T) reprezinta timpul necesar particulei pentru este mai mare, cu atat rezolutia de detaliu este mai buna dar
a efectua o oscilatie completa si a reveni la pozitia initials penetratia este mai mica.
de echilibru.
- Lungimea de unda (X) reprezinta distanta parcursa de
unda sonora pe durata perioadei. 23. Principiile emisiei ultrasonice conti-
- Frecventa (F) reprezinta numarul de oscilatii complete
pe unitatea de timp (secunda). Unitatea de masura pentru
nue si pulsate; focalizarea si divergenta
frecventa este HERTZ (Hz). Ultrasunetele (US) sunt sunetele fasciculului ultrasonor; modurile A, B,
a caror frecventa depaseste limita superioara a domeniului su- TM; rezolutia spatiala si temporala a
netelor audibile, pentru om (18kHz). US utilizate de rutina in
diagnosticul ecografic au frecventa cuprinsa intre 3-13 MHz. imaginilor ecografice, implicatii in for-
- Vlteza (c) sunetului reprezinta distanta parcursa de unda marea imaginilor
in unitatea de timp si se mascara in metri / secunda.
Impedanta acustica (Z) reprezinta produsul dintre vite-
Sorin M. Dudea
za sunetului printr-un anumit mediu si densitatea mediului
respectiv. Unitatea de masura este N x s / m2 denumita rayl. Principiul fundamental de obtinere a informatiei
Impedantele acustice ale tesuturilor moi din corpul omenesc ultrasonograflce. Transductorul functioneaza alternativ ca
au valori foarte apropiate, in timp ce aerul si osul sunt ca- emitator si receptor de US, generand regulat impulsuri de
racterizate prin valori care se abat mult de la media pentru US cu durata de cca. 1 microsecunda si, apoi, receptionand
tesuturile moi. Valorile impedantei acustice au o importanta ecourile un timp bine defmit, dupa care ciclul emisie-receptie
mare in generarea ultrasunetelor reflectate. se reia (emisie USpulsatorie). Emisia de US are un caracter
Efectul piezoelectric. Ultrasunetele utilizate in diagnos- pulsator, intermitent. Ceramica piezoelectrica supusa unei
ticul ecografic sunt generate prin efectul piezoelectric. Acest diferente de potential emite un impuls scurt de US care, pe
efect consta din aparitia unei diferente de potential electric masura ce se propaga in mediul de transmisie, intalneste
intre cele doua suprafete ale unui cristal piezoelectric, atunci interfete. La nivelul fiecarei interfete, o parte din energia
Radiologie imagistica medicala

acustica se refleclS, generand ecourile, iar restul de energie organismului, in planul in care esle miscal transduclorul.
se propaga mai departe, spre o alta interfata. US reflectate Ecografia bidimensionala este modalitalea de diagnostic US
parcurg traseul invers fasciculului incident, lovesc ceramica eel mai frecvent utilizala in praclica medicala.
transductorului si genereaza impulsuri electrice, prin efect Modul M (modularea pozilie-limp, M sau TM Mode)
piezoelectric inversat. Ecoul corespunzator inlerfetei celei are ulililate in ecocardiografie, pentru studierea miscarilor
mai apropiate de transductor este receplionat primul iar apoi rapide ale struclurilor cardiace. In acesl mod de examinare,
sunt receptionate, pe rand, ecouri de la interfele din ce in ce linia de informalie prin spaliu esle menlinuta nemiscata,
mai indepartale. Ca atare, in urma emiterii unui singur impuls ecourile fiind, de asemenea, Iransformale in puncle slraluci-
de US sunt receptionate mai multe ecouri distanlate intre ele in toare. Fasciculul de US intersecleaza slructuri mobile (valve,
timp, datorita distantarii in spatiu a interfetelor care au general pereti cardiaci) care genereaza ecouri puternice, angrenate
aceste ecouri. Amplitudinea impulsului electric general de intr-o miscare ritmica de du-te-vino in susul si in josul liniei
ecou este direct proportionals cu intensitalea ecoului. de informatie. Prin derularea uniforma eleclronica pe ecran,
Una dinlre modalitatile de explorare Doppler folosesle se obtine o desfasurare in timp a miscarii slruclurilor cardi-
emisia continua a US, potrivita pentru analiza hemodinamica ace, sub forma unor curbe ondulale, rilmale. Ecograma in
dar inadecvata pentru obtinerea imaginilor. modul M are doua dimensiuni: pe verticals esle prezenlala
Fasciculul de US emis de o ceramica piezoelectrica are, miscarea in spaliu iar pe orizonlala limpul. Orice Iraseu oblic
in spatiu, doua zone cu geometrie diferitS: langa transductor are asociatS viteza (distanla parcursS de o structure intr-un
(zona apropiata) fasciculul esle cilindric iar la distanta de interval de timp).
transductor (zona indepartata) fasciculul este divergent, Rezolutia. Acest termen defmeste canlilalea de informalie
tronconic. Rezolutia de detaliu in sens lateral este cu alal oferilS de o meloda sau imagine. Cu cat informatia este mai
mai buna cu cat fasciculul este mai ingust. In zona apro- mulla, cu alal se afirma ca rezolutia este mai buna. In ecografie
piata rezolulia este mai buna decat in zona indepartata, de rezolutia poale fi privilS prin Irei perspective: de delaliu, de
divergenta. Penlru a obline un fascicul cat mai subtire, se conlrasl si lemporala.
recurge la focalizarea acestuia. Focalizarea poate fi fixa (prin Rezolutia de detaliu defmeste dislanla minima inlre doua
aplicarea unei concavitati lip lenlilS ceramicii piezoeleclrice) puncte separate din spatiu care apar separat pe imaginea
sau dinamica, controlabila de examinator (prin activare elec- ecografica. Cu cal dislanta intre cele douS puncte esle mai
Ironica diferenliala a elemenlelor ceramicii). Locul in care mica, cu alal se afirmS ca rezolutia este mai buna. Rezolutia de
fasciculul focalizat este eel mai ingust se numeste puncl focal, detaliu trebuie considerala separal in sens axial si lateral.
dislanla de la punct la transductor este distanla focala iar in Rezolutia axiala esle rezolutia mSsurala in sensul de pro-
jurul punctului focal exist! o zona focala in care fasciculul pagare al ultrasunelelor. Ea depinde de frecventa US precum
are grosime optima (minima). si de durata impulsului de US. Pentru o rezolutie axiala buna
Modalitati de Tnscriere a informatiei ecograflce. 1m- sunl necesare: frecvenla nominala mare a Iransduclorului si
pulsurile eleclrice corespunzatoare ecourilor receplionale pol impuls de US cal mai scurt.
fi afisale grafic in mai mulle moduri. Rezolutia laterala este rezolutia masuratS in sensul
Modul A (modularea amplitudinii, A-Mode) este repre- perpendicular pe directia de propagare a US. Ea depinde de
zentarea grafica a unei singure linii de informalie in spatiu. grosimea fasciculului US. Penlru o rezolutie laterals buna esle
Pe orizonlala esle reprezenlata amplitudinea ecourilor iar pe necesar un fascicul de US cal mai sublire. Acesl dezideral
verticals, profunzimea de la care provin acesle ecouri. se obtine prin focalizarea fasciculului de US (a se vedea mai
Modul B (modularea stralucirii, B-Mode) sta la baza sus). In zona focala rezolutia laterals este maxima. Focali-
obtinerii imaginii ecografice bidimensionale. Fiecare ecou al zarea electronics permite pozitionarea mai multor focare pe
unei linii de informalie ultrasonora este transformal electronic imagine, in acelasi limp.
intr-un punct luminos, avand stralucirea cu atal mai mare cu Rezolutia temporala se refera la capacilalea de a idenlifica
cal amplitudinea ecoului este mai mare. Prin miscarea trans- pozilia unei slrucluri in orice momenl si afisarea miscSrii unei
ductorului (manuala sau automala) se oblin mii de aslfel de slrucluri pe monitor sub forma unei succesiuni de imagini.
linii, alaturate, care genereaza imaginea ecografica bidimensi- Frecvenla mare de afisare a imaginilor pe monitor inseamna
onala, intrucal ampliludinea ecourilor pe fiecare linie in parte rezolulie temporals buna.
variaza in functie de caracteristicile tesuturilor inlalnile de AdSugarea unei noi zone focale pe imagine necesila
US. Imaginea ecografica in modul B reprezinla o tomograma generarea si delectarea unui fascicul de ultrasunele separal.
plana bidimensionala ultrasonora a unei regiuni limilale a Ulilizarea focarelor multiple, precum si cresterea profunzimii
Capitolul I. Principii ale tehnologiilor imagistice 39
de explorare, determina reducerea actualizSrii imaginilor si Inregistrarea variatiei FD in functie de timp reprezinta
implicit a rezolutiei temporale. Frecventa mare a imaginilor informati a fundamental a obtinutaprin examinarea Doppler.
(mai mult de 20 de imagini/secunda) este necesara pentru a In conditii optime de examinare, prin metoda Doppler se
detecta miscarile rapide sau pentru manoperele ecoghidate. inregistreaza in fapt variatia vitezei si a sensului fluxului
La o frecventa de afisare mai mica de 16 imagini/secunda sanguin in functie de timp.
calitatea informatiei bidimensionale este ameliorata (linii de in tehnica Doppler fasciculul de US trebuie sa descrie un
informatie ,,impachetate" dens) dar se degradeaza rezolutia unghi cat mai mic cu directia de curgere a fluxului in vasele
temporals, iar sub 10 imagini / secunda. aspectul filmului de sanguine pentru ca viteza fluxului sa poata fi calculata corect
pe ecran devine sacadat. Cresterea penetratiei, a numarului de din frecventa diferentiala. Unghiul de incidents trebuie sa fie
linii de informatie de pe o imagine individuals si a numarului mai mic de 60° pentru a se obtine valori reale, utile clinic, ale
de focare pe o imagine individuals duce la scaderea frecvenfei vitezei fluxului sanguin.
imaginilor si, implicit, a rezolufiei temporale. Informatiile obtinute prin metoda Doppler sunt inscrise
Pentru examinarea cu rezolutie mare sunt necesare: pe un grafic care reprezinta desfasurarea variatiei frecventei
frecventa mare a transductorului, focalizare fina cu focare diferentiale in functie de timp si care se numeste curba Dop-
multiple si frecventa mare a imaginilor. Aceste deziderate pler (traseul sau semnalul Doppler) Acest grafic reprezinta pe
pot fi obtinute usor pentru organele aflate la distantS mica verticals FD iar pe orizontala, timpul. Toate traseele oblice
de transductor (organele aflate imediat sub piele sau langa definesc modificarea vitezei in timp: crestere (acceleratie)
transductorul endocavitar). Organele aflate la distanta mare de sau scadere (decelerate).
transductor sunt examinate cu cea mai mare frecventa a trans- Informatiile fundamentale obtinute prin metoda
ductorului care permite examinarea organului respectiv. Doppler sunt: prezenta, sensul, viteza si caracterul fluxului
sanguin precum si estimarea numarului de hematii care con-
tribuie la generarea semnalului Doppler.
24. Efectul Doppler; definirea directiei Prezenta fluxului sanguin este tradusa de aparitia unei
de curgere si angularea fasciculului; emi- deflexiuni fata de linia timpului;
Sensul fluxului sanguin: apropierea de transductor este
sia Doppler pulsata si continua; analiza inscrisS, in mod conventional, deasupra liniei timpului (sem-
spectrului ultrasonor Doppler; Doppler nal pozitiv) iar indepSrtarea de transductor - dedesubtul liniei
timpului (semnal negativ);
color si power Viteza curentului sanguin poate fi aflatS pentru orice mo-
Sorin M. Dudea, Carolina Botar-Jid ment al revolutiei cardiace, daca se rezolva ecuatia Doppler,
respectiv dacS este introdusa corectia unghiului. In aceasta
Efectul Doppler situatie, pe verticala graficului curbei Doppler FD este inlo-
In corpul omenesc, reflectorul studiat cu ajutorul efectului cuita de catre viteza.
Doppler este fluxul sanguin in cord si vase, alcatuit din fisicuri Caracterul laminar sau turbulent al fluxului poate fi dedus
de hematii si caracterizat prin sens si vitezS de miscare. Ultra- din aspectul traseului Doppler cu reprezentare spectrala.
sonografia Doppler studiaza/recve«/a ecourilor. Variatia de Estimarea numarului de hematii care contribuie la ge-
frecventa saufrecventa diferentiala (FD) reprezinta diferenta neza semnalului Doppler poate fi facutS prin intermediul
dintre frecventa emisa de transductor (FE) si cea reflectata intensitatii (sau puterii) semnalului Doppler. Pe aceasta
de hematii si receptionata de transductor (FR). informatie se bazeaza tehnica Power Doppler.
Definirea directiei de curgere a fluxului Din informatiile primare prezentate mai sus pot fi deri-
In functie de sensul de deplasare al reflectorului, in vate informatii secundare cu mare valoare diagnostics, spre
conformitate cu efectul Doppler, pot fi intalnite urmatoarele exemplu: gradientul de presiune intre cei doi versanti ai unei
situatii: stenoze sau ai unui orificiu valvular; severitatea unei stenoze
- daca reflectorul este stationar: FR = FE; FD = 0 arteriale; debitul sanguin printr-un vas etc.
- daca reflectorul (fluxul sanguin) se apropie de trans- Modalitatile de examinare Doppler sunt: Doppler conti-
ductor: FR > FE; FD > 0 nuu, pulsat, color, power, power directional. De asemenea,
- daca reflectorul (fluxul sanguin) se indeparteaza de elastografia ultrasonora se bazeaza, la unele aparate, pe
transductor: FR < FE; FD < 0. efectul Doppler.
40 Radiologie imagistica medicala

Doppler continuu - emisia sunetelor si receptia ecourilor deschise, apropiate de alb. Metoda nu confine informatie
se face continuu. Metoda este lipsita de rezolutie spatiala si directionala privind fluxul. Avantajul metodei il reprezinta
dificil de asociat cu imagini dar poate masura viteze oricat sensibilitatea mare pentru fluxuri lente si lipsa artefactului
de mari ale fluxului. de ambiguitate a inscrierii informatiei.
Doppler pulsat - emisia si receptia sunetelor se supun In tehnica power Doppler directional sc pastreaza
ciclului puls-ecou, sunt discontinue, ritmice. Datorita acestei informatia directionala din Doppler color si sensibilitatea
particularita|i, metoda are rezolutie spatiala foarte buna, se aferenta metodei power.
poate analiza fluxul intr-o zona (volum) foarte limitata din
spatiu, denumita esantion Doppler (de volum). Metoda este
foarte usor asociata cu imaginile in timp real, se poate derula 25. Transductoare: descriere, recunoas-
simultan cu acestea (duplex - Doppler). Principala limitare
o constituie artefactul de ambiguitate a inscrierii informatiei tere, utilizare in relatie cu organul exa-
(aliasing): la viteze mari ale fluxului, inscrierea informatiei se minat; valoarea relativa a ecografiei
face pe ambii versanti ai liniei timpului, astfel meat masurarea
vitezei devine imposibila iar uneori nu se mai poate stabili
transcutanate fata de ecografia endolu-
nici macar direcfia de curgere a fluxului. menala; componentele unui echipament
Metoda Doppler pulsat este caracterizata prin reprezen- de diagnostic ecografic
tarea spectrala a semnalului, tradusa prin grosimea liniei
care inscrie traseul Doppler. Fluxul laminar, ordonat, este Sorin M. Dudea
caracterizat prin spectru ingust - linie subtire. Fluxul tur-
bulent, dezordonat (poststenotic sau in dilatari focale) este Transductoarele sunt i n s t a l a t i i care genereaza/
caracterizat prin spectru larg (linie groasa, umplerea spatiului receptioneaza ecouri. Transductorul este dispozitivul care
dintre linia timpului si anvelopa curbei Doppler). transforma o forma de energie in alta.
Doppler color este Doppler pulsat multiesantion. Intr-o re- Exista 4 clase de transductoare:
giune de interes, fiecare grup de pixeli devine esantion de volum. - liniare;
Pentru reprezentarea informatiei Doppler se folosesc culorile. - sectoriale:
Prezenta fluxului sanguin este tradusa de colorarea - monosonde;
imaginii; - combinate.
Sensul fluxului sanguin: apropierea de transductor este Transductoare liniare:
inscrisa, in mod conventional, cu rosu (semnal pozitiv) iar Caracteristici: - ultrasunetele sunt emise de pe o linie de
indepartarea de transductor - cu albastru (semnal negativ); cristale; ultrasunetele se propaga paralel intre ele; formatul
Viteza curentului sanguin este reprezentata de nuanja cu- imaginii este dreptunghiular.
lorii de baza (caracteristica pentru sens): viteze mici = nuante Clasificare dupa modul de generare al fasciculului de
inchise; viteze mari = nuante deschise, apropiate de alb. ultrasunete:
Caracterul laminar sau turbulent al fluxului este revelat a) transductoare elecrronice: cristale in linie ca niste
de puritatea culorii. Fluxul laminar are culoare pura (albastru ,,clape de pian'': activate in serie in mod electronic.
sau rosu). Fluxul turbulent este denotat prin adaugarea culorii b) transductoare mecanice: - piesa piezoelectrica este
verde la culoarea de baza (nuantele devin portocaliu. turcoaz unica si se misca asemeni unui ,,cartus de imprimanta";
sau aspect de mozaic). piesa emite/receptioneaza ultrasunetele; aproape ca nu se
Tehnica Doppler color are toate avantajele si dezavanta- mai utilizeaza azi.
jele, inclusiv artefactele, metodei Doppler pulsat. Principalul Transductoare sectoriale
atu al metodei il reprezinta rezolutia spatiala mare, cu ex- Exista doua tipuri de transductoare sectoriale: mecanice
plorarea simultana a unei sectiuni intregi prin corp. ceea ce si electronice.
reduce mult durata globala a examinarii Doppler. a) transductoare mecanice: - ultrasunetele se emit de pe o
Metoda power Doppler reprezinta puterea relativa a suprafata mica; ultrasunetele sunt emise divergent; ecourile se
semnalului Doppler, acolo unde este detectata frecventa receptioneaza convergent; imaginea rezultata este un sector
diferentiala, inscrisa pe o scala monocroma in care variaza de cere, transductorul in varful sectorului.
doar nuantele culorii. Semnalul slab este reprezentat prin Variante constructive:
nuante inchise iar eel mai puternic semnal, prin nuante - pendulante - un cristal efectueaza miscare de metronom;
Capitolul 1. Principii ale tehnologiilor imagistice 41

- rotative gia peretelui vezicii urinare, prostata); endoluminal (in tub


- cu o singura piesa: pentru aplicajii endocavitare digestiv); microtransductoare pentru cavitatea uterina, pentru
(cavitati naturale); transductoare ,,sectoriale perfec- trompe uterine; vezica urinara, uretere; vase sanguine.
te"; imaginea este un cere complet. transductorul este - intraoperator: transductoare cu suprafata mica; complet
plasat in centrul imaginii. sterilizabile; transductoare pentru uz laparoscopic.
- cu mai multe piese: piesele piezoelectrice sunt pla- Mai dificil de aplicat, necesita masuri de asepsie, ste-
sate sub forma de stea pe axul unui motor; imaginea rilizare, mai greu acceptate de pacient; ofera informatii cu
este un sector de cere; rezolutie mare despre organe greu accesibile.
b) transductoare electronice: - imaginea este tot un sector Elementele tehnice constructive ale aparatelor de
de cere; ecografie
Variante constructive: - Generatorul de puls - produce si moduleaza impulsul
- propriu-zis (phased-array): exista o suprafata relativ electric care va stimula ceramica piezoelectrica
mica pe care sunt plasate elementele piezoelectrice; elemen- - Generatorul de fascicul US - asigura focalizarea elec-
tele piezoelectrice sunt activate succesiv, numai ca diferenta tronica a impulsului
de activate in timp. este foarte mica (microsecunde); se - Transductorul - emite US explorator si receptioneaza
obtin o serie de fascicule divergente rezultate din activarea ecourile:
elementelor piezoelectrice. - Receptorul - este sediul unor amplificari si preprocesari
- convex: transductorul este unul ,,liniaf' ca si construcfie ale semnalului US, in special curba TGC
dar cu suprafata curba; imaginea rezultata este tot un sector - Memoria electronica - depoziteaza si prelucreaza
de cere; informatia primara, genereaza setul de informatii finale,
- anular: combinatie intre transductorul mecanic si transmise la monitor
transductorul electronic; constructiv este alcatuit dintr-o - Monitor TV - an§eaza informatia fmala.
serie de inele concentrice de materiale piezoelectrice antre- Orice aparat de ecografie are doua componente distincte:
nate in miscare de pendulare; emisia se face divergent (prin - consola - contine tastatura de comanda si control, com-
constructie); ansamblul penduleaza in fata unei ferestre de puterul si electronica aparatului si monitorul;
emisie; receptia se face convergent. - transductoarele.
Transductoare monosonde
- contin 1 cristal piezoelectric; se folosesc pentru: eco-
grafie in modul „"; examinarea Doppler continuu; ecografie 26. Obtinerea unei imagini ecografice op-
bidimensionala statica. Sunt practic abandonate astazi (cu time: criterii de recunoastere, modalitati
exceptia unor aplicatii vasculare).
Transductoare combinate de realizare; aspectul ecografie al orga-
- toate transductoarele de astazi au frecvente multiple si nelor normale si al principalelor entitati
functii multiple. Exista transductoare speciale pentru eco-
grafia tridimensionala.
patologice
Utilizare in relatie cu organul examinat Sorin M. Dudea
Transductoarele liniare sunt utilizate pentru explorarea
tesuturilor moi superficiale (san, tiroida, testicul, ganglion!, Criterii de recunoastere si modalitati de realizare ale
aparat locomotor). unei imagini ecografice optime:
Transductoarele sectoriale electronice (in special variante - orientarea spatiala corecta:
convex) sunt utilizate pentru explorarea abdomino-pelviana. - sus = transductorul, respectiv locul de aplicare al
Transductoarele sectoriale mecanice sau phased array au acestuia pe corp (anterior, lateral dreapta sau stanga,
utilizare in ecocardiografie. posterior);
Aplicarea transductoarelor - jos = punctul cardinal opus transductorului (posteri-
- externa: rapida, usor de acceptat de catre pacient, or, medial stanga sau dreapta, anterior - respectiv);
informatii limitate de catre interpunerea aerului sau osului; - stanga imaginii = dreapta pacientului (sectiuni trans-
rezolutie limitata pentru organele profunde. versale) sau cranial (sectiuni sagitale sau frontale);
- endocavitara: endorectal (pentru prostata); endovaginal - dreapta imaginii = stanga pacientului (sectiuni trans-
(pentru uter, col uterin, ovare); endovezical (pentru morfolo- versale) sau caudal (sectiuni sagitale sau frontale).
Radiologie imagistica medicala

- organul / leziunea tinta se afla in centrul imaginii; ocupa - difuz inomogena - apare ca si granularitate crescuta si
eel putin 2/3 din suprafata activa a imaginii; neuniforma a organului.
- este utilizat transductorul cu cea mai mare frecventa Atenuarea acustica. In mod natural, ecourile care provin
care permite explorarea organului respectiv; de langa transductor sunt puternice, celelalte sunt tot mai
- focarul / focarele sunt asezate in dreptul leziunii; slabe. Pentru a uniformiza ecourile, se foloseste curba TGC.
- curba TGC este setata astfel incat ecourile sa aiba in- Daca nu se reuseste uniformizarea imaginii prin reglarea cur-
tensitate uniforma pe intreaga adancime a imaginii; soarelor pentru TGC iar imaginea ramane mai hipoecogena
- contrastul si domeniul dinamic al ecourilor sunt setate la distanta de transductor, fenomenul poarta denumirea de
astfel incat sa ofere rezolutie de contrast maxima; atenuare acustica si, pentru ficat, este semn de suferinta.
- functiile auxiliare si de postprocesare (armonica, ne- Ampliftcarea (intarirea) acustica apare, eel mai adesea,
tezirea imaginii) sunt setate astfel incat sa confere calitate in spatele unor structuri lichidiene. Structurile aflate in
vizuala maxima imaginii spatele unei imagini transsonice apar mai stralucitoare pe
Aspectul ecograflc al organelor normale si al princi- imagine. Aceasta observatie atesta ca imaginea transsonica
palelor entitati patologice. este lichid.
Semiologie ecografica elementara. Deoarece informatia Umbra acustica +focar hiperecogen se traduce pe ima-
ecografica apare prin nuante de gri care reprezinta ecourile gine printr-o dunga neagra de lipsa de informatie ecografica.
unul in raport cu celalalt, nu exista o unitate de masura a Ultrasunetele sunt reflectate in totalitate de o structura ecoge-
ecogenitatii in cifre. Cel mai puternic ecou este alb, lipsa de na: focarul hiperecogen. Termenul corect este umbra acustica,
ecou apare in negru. pentru ca forma poate fi diferita de cea de con. Umbrele
Ecogenitate = calitatea unui tesut de a produce ecouri. acustice pot fi unice sau multiple (pot fi mai mici si alaturate).
Tesuturile care produc ecou = ecogene. Tesuturile care intarirea si umbra acustica poate fi observate NUMAI
nu produc ecou = transsonice (anecogene, negru). Aceste posterior de structura care le-a produs.
imagini pot fi date de lichid, sau apar in zone unde nu exista Scara normala a ecogenitatii structurilor parenchima-
interfete. toase in abdomen, de la eel mai ecogen la eel mai putin
Pentru abdomen - tesutul de referinta este FICATUL. ecogen:
Fata de ficat o structura poate fi hiperecogena (mai alba decat 1 - sinusul renal
ficatul), hipoecogena (mai neagra decat ficatul) sau izoeco- 2 - pancreas
gena (este la fel cu ficatul). 3 - ficat
Transsonic (anecogen) - lipsit de ecou. Aceste structuri 4 - splina
pot fi: 5 - corticala renala
- normale - structuri care contin lichid (vezica urinara, 6 - medulara renala
vezica biliara) Descrierea ecografica a unei structuri patologice:
- patologice - formatiuni care conjin lichid (chiste, 1.Natura si ecogenitatea: masa, formatiune, etc.
tumori) - Hiperecogen
Structurile anecogene patologice pot fi: - Hipoecogen
- pur transsonice - lichidiene perfect = perfect negre - Izoecogen
- cu lichid impur - gri foarte inchis (lichid ce seamana 2.Localizarea
cu o crema, are in interior sange sau puroi): 3.Numar:
- imagini mixte - in interiorul unei structuri predominant - unica
negre (lichidiene) exista si imagini ecogene. solide. - multiple (peste doua)
Ecostructura defineste totalitatea ecourilor retumate de 4. Forma: rotunda, ovala, sferica
catre un tesut parenchimatos, organizate intr-o structura co- S.Dimensiuni
erenta care permite identificarea unui organ. Exemplu: ficat, 6.Contur: net, bine delimitat, flu, invadant,
testicul, splina, tiroida - sunt imagini care apar ca un amestec 7. Structura:
de ,,sare si piper fin". Structura poate fi: - omogena
- omogena - exceptand vasele din interiorul lor. parenchi- - inomogena (mixta, cu continut impur, etc)
mele sunt uniforme, omogene; S.Raporturi anatomice
- franc inomogena - exista multiple imagini de alta natura 9. Starea functionala (daca se poate)
decat parenchimul; 10. Aspecte particulare
Capitolul 1. Principii ale tehnologiilor imagistice 43

27. Artefactele in ecografia in scara gri matate de lichid si jumatatea de alaturi este solida, aparatul
arata media ecogenitatii, adica nici lichid, nici solid ci gri
si ecografia Doppler: cauze, descriere, intermediar. Pentru a sti daca este volum partial sau nu: se
modalitati de eliminare. Efectele termice roteste transductorul si se obtine imaginea in alt plan. Orice
si mecanice ale ultrasunetelor in biologic; modificare patologica trebuie sa fie vizibila in doua planuri
ortogonale (si pe transversal si pe longitudinal).
fenomenul de cavitatie - Reverberajia - US intalnesc o interfata care reflecta toate
Sorin M. Dudea, Carolina Botar-Jid sunetele, acestea lovesc transductorul si se reflecta iar spre
interfata. La fiecare intoarcere sunetele produc cate un ecou.
Aparatul interpreteaza ca ecourile primite mai tarziu provin de
Artefact = surse de eroare. Artefact = aspecte neadevarate la o distanta mai mare. Pe imagine sunt inscrise ecouri liniare,
ce se vad pe imaginea ecografica. unele sub altele. la distante egale unele de altele. Eliminare:
Pot sa apara: se incearca sa se ocoleasca interfata cauzatoare.
- structuri ireale - Coada de cometa (varianta de reverberatie) - Undele
- structuri absente (falsa lipsa a imaginii) sunt prinse intre doua interfete foarte apropiate si are loc
- structuri neadecvate ca localizare, forma, structura miscarea de du-te-vino; vor aparea linii foarte apropiate una
Geneza: incalcarea premizelor de formare a imaginii US: de alta si pe masura ce distanta fata de transductor creste, ele
- propagarea in linie dreapta; se pierd in profunzime. Coada de cometa poate fi produsa
- distanta dintre obiecte este proportionala cu timpul doar de aer, metal sau cristal.
de receptie a ecoului; Pozifionare incorecta in sens lateral
- ecourile provin doar de la obiecte aflate in axa fas- - Falsa dedublare a unor organe. Acest artefact apare la
ciculului de ultrasunete; nivelul peretelui abdominal, produs de muschii drepti abdo-
- intensitatea ecoului este direct proportionala cu minali si linia alba. Un fascicul de US trece prin linia alba,
proprietatea de reflectare sau dispersie ultrasonora ajunge la aorta si se reflecta, duce la inscrierea aortei in pozitia
a obiectului examinat. corecta. Un alt fascicul se refracta de doua ori prin muschiul
Nu intotdeauna artefactele sunt inutile. Exista artefacte drept abdominal si ajunge tot la aorta. Ecoul se refracta in
care ajuta la diagnostic (umbra acustica + focar ecogen = cal- sens invers si ajunge la transductor. Aparatul interpreteaza ca
cifiere; imagine transsonica + amplificare acustica = chist). ecoul provine din linie dreapta si induce inscrierea pe imagine
Clasificarea artefactelor: a doua aorte. Acest artefact poate sa apara si la nivelul polului
- de propagare superior renal stang, datorita splinei, si induce imagine pse-
- de atenuare udotumorala. Eliminare: se schimba pozitia transductorului
- specifice Doppler sau a organului, prin respira|ie.
Artefacte de propagare - Lobii laterali. Cand sunetele cad oblic pe o interfata
Imagine neclara ecourile se reflecta de partea cealalta a perpendicularei si nu
- datorita rezolutiei axiale si laterale slabe; se mai intorc la transductor. Daca un alt cristal piezoelectric
- datorita zgomotului de fond. Eliminarea zgomotului de intercepteaza aceste ecouri, ele sunt inscrise pe imagine intr-o
fond: se face medierea mai multor imagini succesive pozitie nereala.
False imagini suplimentare Pozitionare incorecta in sens axial
- Fals sediment - poate aparea, spre exemplu, in vezica - Eroarea de viteza - daca viteza reala a US este > 1540
urinara aspect de sediment (zona gri), vezica nu este trans- m/s, datorita timpului de receptie mai scurt se inscrie pozitia
sonica. Acest aspect apare deoarece US intrate in vezica se organului mai aproape de transductor. La viteza < 1540 m/s,
reflecta succesiv pe pereti si se intersecteaza. Sunetele sunt organul este inscris mai departe de transductor.
in faza si produc efect de amplificare. Eliminarea falsului - Imaginea in oglinda (varianta de artefact de cale
sediment: se roteste pacientul. Daca sedimentul este real, se multipla). Cand sunetele intalnesc o interfata concava (dia-
va misca odata cu pacientul. Daca este artefact, va ramane fragma) care le reflecta in totalitate, ele se reflecta pana la o
pe loc. Se poate reduce curba TGC (se reduce amplitudinea alta structura, subdiafragmatica, iar ecoul parcurge calea in
undelor) —> unde mai slabe, nu se mai produc artefacte. sens invers. Aparatul interpreteaza ca ecoul provine, din linie
- Volumul partial - datorita faptului ca planul de US nu dreapta, de la o distanta mai mare (dincolo de diafragma).
este lipsit de grosime. Daca grosimea este ocupata pe ju- Va rezulta imagine in oglinda. Se poate vizualiza ficatul,
44 Radiologie imagistica medicala

porta, colecistul, rinichiul dincolo de diafragma. Eliminarea - miscarile pacientului sau ale vasului
imaginii in oglinda: se iau in considerare doar imaginile de - pozitia fasciculului de US fata de lumenul vasului
deasupra interfetei. Artefactele caracteristice tehnicii Doppler color
- Ambiguitatea localizarii in profunzime. Daca un ecou - lipsa culorii acolo unde exista flux
se intoarce la transductor dupa emisia unui nou impuls de US, - umbra acustica
el este inscris pe imagine mult mai aproape de transductor - atenuarea
decat interfata care 1-a produs. Recunoastere: la apasarea cu - refractia
transductorul, ecoul pastreazarelatie fixa cu acesta si variabila - unghi de abord de 900
cu restul anatomiei corpului. - reglarea incorecta a aparatului
Artefacte de atenuare - prezenta culorii acolo unde nu exista flux
Prea putine ecouri - ambiguitatea localizarii in profunzime
- Umbra acustica = prea putine ecouri. Umbra acustica - lobii laterali
poate sa provina de la interfata puternic ecogena - umbra - imaginea in oglinda
acustica adevarata - scintilatia acustica
- Umbra marginala - Poate sa apara umbra acustica si - artefactul de flash
fara interfata ecogena datorita difractiei US la marginea - zgomotele viscerale
unei interfere. - zgomotul tisular
Prea multe ecouri - falsa alocare a culorii
- Amplificare acustica = prea multe ecouri. Este de fapt - reprezentarea incorecta a vitezei si/sau sensului fluxului
lipsa de atenuare a US prin lichide. Amplificarea acustica de- - fenomenul de ambiguitate
ranjeaza deoarece mascheaza structurile din spatele structurii - reglarea inversata a culorilor
lichidiene. Eliminarea: se reduc ecourile din spatele masei - inversarea pozitiei transductorului
lichidiene, cu ajutorul TGC. - dependenta culorii de unghiul de abord al vasului
- Amplificarea focala - in dreptul focarului ecourile au - falsul aspect de flux bidirectional in vas
intotdeauna intensitate mai mare. Artefactele tehnicii power Doppler
Artefacte specifice tehnicii Doppler - de miscare
Artefacte caracteristice tehnicii Doppler spectral - falsa alocare a culorii
- cu exces de semnal Efecte biologice ale ultrasunetelor
- imaginea in oglinda a fluxului Ultrasunetele nu sunt lipsite de efecte biologice. Aceste
- zgomotele extrinseci efecte depind in principal de trei factori: intensitatea fluxu-
- amplificarea electrica lui de energie sonora, timpul de expunere la energia sonora
- interferentele electromagnetice incidents si frecventa US. Pe prezenta efectelor biologice se
- sensibilitatea prea mare a receptorului bazeaza utilizarea US in tratamentele reumatologice, in sto-
- semnalul armonic matologie (detartraj) si in chirurgie: litotritia extracorporeala
- cu minus de semnal prin unda de soc a calculilor si bisturiele cu US. Exista insa
- cuplarea inadecvata a transductorului diferente cantitative si calitative insemnate intre US cu actiune
- sensibilitatea prea mica a aparatului ..distructiva" si US folosite in scop diagnostic. Principalele
- filtrarea excesiva efecte biologice ale US, demonstrate experimental pe animale
- cu reprezentarea eronata a semnalului Doppler pot fi sintetizate dupa cum unneaza:
- fenomenul de ambiguitate (aliasing) Efectul biofizic de cavitatie poate imbraca doua aspecte:
- compresia afisarii traseului Doppler - cavitatia tranzitorie: sub influenta campului vibrant de
- stabilirea eronata a sensului de curgere a fluxului US, in lichidele biologice pot aparea mici bule cu gaz, care
- efectul unghiului de abord asupra calitatii semna- oscileaza in campul US si isi maresc progresiv dimensiunile.
lului La intensitati mari ale US, bulele pot colaba subit, ducand la
- efectele scalei vitezelor cresterile locale marcate de temperatura, urmate de descom-
- artefacte neasteptate produse de catre aparat punerea termica a apei si eliberarea de radical! liberi.
- interferenta de la vasele din vecinatate - cavitatia stabila: la intensitati moderate alefluxuluide
- compresiunea vasului US, bulele pulseaza permanent in campul sonor si pot produce
- factorii care afecteaza hemodinamica pacientului modificari ale structurilor celulare adiacente.
Capitolul 1. Principii ale tehnologiilor imagistice 45

Efectul termic: US produc incalzirea |esuturilor pe care 28. Valoarea relativa a examinarii eco-
le strabat, atat prin fenomenul de cavitatie cat si in urma
absorbtiei. grafice; indicatiile pentru diverse or-
Toate efectele biologice enumerate mai sus au fost gane si sisteme; indicatiile de utilizare
obtinute experimental prin expunerea animalelor la US cu
intensitati mai mari de !W/cm2 (uneori zeci de W/cm2),
a substantelor de contrast ecografic;
timp de minute, zeci de minute sau ore, frecventa US fiind tehnici ecografice speciale: armonici,
injur de 1MHz. tridimensional, elastografie
In cursul unei examinari ecografice obisnuite. transducto-
rul emite de cca. lOOOOdeori/secundaimpulsuridurand 1-1.5 Radii Ion Badea
microsecunde. In restul de 99,9% din timp se receptioneaza
ecourile. Ca atare. pe durata unei examinari ecografice. orga-
nismul uman este supus unei energii US incidente doar 0,1% I. Valoarea relativa a examinarii ecografice; indi-
din timp, ceea ce face ca. spre exemplu. pe parcursul unei catiile pentru diverse organe si sisteme
examinari ecografice care dureaza 30 minute, organismul sa II. Indicatiile de utilizare a substantelor de contrast
fie supus la energie US incidenta timp de doar 2 secunde. ecografic
Intensitatea acustica a ecografelor moderne nu depaseste
20 mW/cm2. Frecventa transductorului (deci a US emis) este III. Tehnici ecografice speciale: armonici, tridimen-
situata in jurul valorii de 3,5 MHz. Din aceste date cifrice sional, elastografie
rezulta diferentele cantitative si calitative mari intre US cu
efecte biologice nedorite si US utilizate in scop diagnostic.
Stadiul actual al cunoasterii nu a permis detectarea unor
efecte negative ale US utilizate in scop diagnostic asupra 28.1. Valoarea relativa a examinarii eco-
omului. Cu toate acestea, US nefiind lipsite de efecte bio-
logice, este recomandabila utilizarea prudenta a ecografiei
grafice; indicatiile pentru diverse organe
(principiul ALARA), mai ales in primul trimestru al sarcinii, si sisteme
deoarece inca nu exista date privind eventualele efecte cumu- Radii Ion Badea
lative ale expunerii la doze mici si repetate de US.

Examinarea ecografica este tributara unor principii teore-


tice si practice, care stau la baza diferitelor tipuri de echipa-
mente. Practica ecografiei trebuie sa tina cont de tot ceea ce
inseamna parti bune si parti rele ale metodei. O intelegere a
acestor aspecte permite realizarea unui gest medical de cali-
tate in interesul pacientului si al medicului practician.
Avantaje practice. Ecografia are avantaje si elemente de
atractivitate. Intre acestea:
- costul redus. Acesta se raporteaza la costul tehnicilor
sectionale evoluate (CT/RMN) in situatia in care furnizeaza
aceeasi informatie, cu aceeasi relevanta clinica. Explorarea
ecografica necesita o investitie minima sub aspectul aparaturii
folosite. Chiar la preturi mici, ecografele prezinta o rezolutie
foarte buna a imaginii astfel meat, adesea, pot substitui ex-
plorarea radiologica, indeosebi in ceea ce priveste organele
parenchimatoase.
- acuratetea foarte buna a imaginii. Aceasta este reflec-
tata in capacitatea de detectare a leziunilor. Acuratetea este
conditionata de diferenta de impedanta acustica dintre aces-
tea. Teoretic, un chist intr - un parenchim poate fi detectat de
46 Radiologie imagistica medicala

la dimensiuni de ordinul a 1-2 mm iar o tumora solida poate - caracterul ,,artefactogen" al procedurii. Ultrasunetele
sa apara distinct de la un diametru de 10 mm; penetreaza (si se reflecta) in mod diferit la nivelul diverselor
- caracteruldinamic (,,realtime"). Reprezinta potentialul structuri tisulare. In plus, aerul si structurile osoase impiedica
ecografiei de a reprezenta informatia concomitent cu achizitia obtinerea unei imagini ecografice de calitate. Exista numeroa-
acesteia. Ecografia pune in evidenta anatomia organelor se siruatii in care imaginea obtinuta contine informatii false
aflate in miscare (ex. cordul, intestinul, diafragmul in timpul (artefacte de imagine). In plus distantele mari care trebuiesc
respiratiei etc). Aceasta caracteristica este completata de strabatute precum si excesul de tesut adipos interactioneaza
evaluarea elasticitatii unui parenchim comprimat de mana cu imaginea ecografica care devine greu interpretabila si
examinatorului (elastografie). Informatiile obtinute sunt ambigua (fenomenul se numeste ,,atenuare").
unice in categoria procedurilor imagistice scotand in evidenta - caracterul subiectiv si operator dependent. Ecografia
caracterul clinic al procedurii. Capacitatea ecografiei de a este inalt dependents de calitatea examinarii, de performantele
vizualiza dinamica organelor (ex. cordul) permite evaluarea si nivelul de pregatire al examinatorului;
functiei unor organe vitale (cordul). - dependentd de rationamentul clinic. Ecograful este
- portabilitatea. Aparatele existente in etapa actuala sunt practic un « stetoscop vizual » si o prelungire a simturilor
miniaturizate si pot sa fie transportate cu usurinta. Ecografele medicului. Examenul fizic al pacientului in conditii de urgen|a
portabile pot sa faca parte din dotarea de baza a medicului este urmat de o electrocardiograma si de o ecografie a abdo-
de familie, alaturi de un electrocardiograf portabil si de un menului si aparatului cardiovascular. Diagnosticul ecografie
laborator pentru investigatiile esentiale; trebuie integral in contextul clinic al pacientului.
- lipsa de invazivitate si de iradiere. Ecografia folosind Indicatii generale. Examinarea ecografica este indicata
ultrasunete ca si vector de formare a imaginii, nu afecteaza in precizarea status-ului - normal sau patologic al organelor
starea de sanatate a pacientului, nu provoaca durere si nu lipsite de continut aerie, precum si in toate situatiile in care
este sangeranda. Metoda este utilizabila ori de cate ori este nu exista interpozitie de aer sau structuri osoase.
necesar, inclusiv pentru explorarea sarcinii. Este posibila Indicative sunt orientate inspre organele parenchimatoase
asadar reevaluarea periodica a pacientului pentru aprecierea (pentru evaluarea structurii si detectarea tumorilor), orga-
cursului bolii; nu prezinta restrictii in utilizare pentru femei nele tubulo - cavitare (pentru evaluarea continutului si/sau
insarcinate sau copii. motilitatii), vase centrale/periferice (pentru evaluarea fluxului
- educatia siformarea in ultrasonografie. Timpul necesar s.i lumenelor), structuri musculo - tegumentare (pentru evalu-
pentru asimilarea procedurii este relativ scurt iar intelegerea area starilor inflamatorii si posttraumatice). Afectiunile care
imaginilor este facila. Sunt necesare cunostinte destul de
pot fi evaluate ecografie sunt acute si cronice.
sumare de anatomic sectionala. Imaginea ecografica este
inteligibila, relativ usor de interpretat, avand aspectul unor
sectiuni anatomice prin corpul uman. Semiologia ecografica
Bibliografie
este simpla, folosind informatii calitative. Consistenja orga-
1. Hertzberg BS, K/ie\ver MA, Bowie JD et al. Physician training
nelor este reprezentata pe ecran sub forma de nuante de gri;
requirements in sonography: how many cases are needed for com-
- numarul mare de aplicatii clinice. Examinarea eco-
petence? AJR 2000: 174: 1221-1227
grafica se adreseaza unui mare numar de organe furnizand
informatii morfologice, functionale, vasculare.
- dirijarea manoperelor interventionale. Ecografia
este utila pentru dirijarea sau asistarea unor proceduri 28.11. Indicatiile de utilizare a substantelor
interventionale. In aceasta categoric intra punctii pentru de contrast ecografie
aspiratie celulara sau extragere de tesut, drenaje de abcese.
proceduri terapeutice cum ar fi injectarea de substante active Radu Ion Badea
sau ablatii cu radiofrecventa.
- interactiunea directa dintre examinator si patient. Particularitatile agentilor de contrast folositi in ultra-
Acesta este un element extrem de important pentru asimi- sonografie. Agentii de contrast (AC) folositi in ultrasonogra-
larea procedurii cu un examen clinic mai elaborat, de inalta fie sunt microbule de gaz stabilizate cu diametru foarte mic
calificare si performanta. (cca. 2-6 urn), invelite intr - o membrana rigida (albumina
Limitari principiale ale metodei ecografice. Ecografia denaturata) sau elastica (substante organice biocompatibile).
nu este o metoda perfecta si medicul examinator trebuie sa Cele mai frecvent utilizate gaze sunt sulfur-hexafluoridul,
tina cont de o serie de elemente. Intre acestea: perfluorocarbonul si azotul. Sulfur-hexafluoridul si per-
Capita III I i. Principii ale tehnologiilor imagistice 4'

fluorocarbonul au greutate moleculara mare si solubilitate adverse sau accidente, iar microbulele nu par sa fi strabatut
scazuta. Realizeaza concentratii ridicate de gaz in interiorul bariera placentara.
microbulelor raportat la sangele inconjurator si prezinta o sta-
bilitate buna In circulatie. Microbulele reflects ultrasunetele
realizand cresterea impedantei acustice cu cca. 20-25 dB. In Bibliografie
felul aceasta coloana de sange capata un aspect hiperecogen 1. ReddyNK, landed AM, Saftoiu A, Vilmann P, Bhutani MS. Con-
in cursul expunerii la ultrasunete cu indice mecanic scazut trast-enhanced endoscopic ultrasonography. World J Gastroenterol.
(0,10). Microbulele raman In circulatie circa 4-5 min. ceea 2011:17:42-48
ce corespunde mai multor cicluri cardiace. AC nu penetrea- 2. Quaia E. Microbubble ultrasound contrast agents: an update.
za in interstitii avand o distribute strict intravasculara. Se EurRadiol. 2007; 17:1995-2008
administreaza i.v., fie ,,in bolus" (de preferat) fie In perfuzie 3. Correas JM, Bridal L, LesavreA etal. Ultrasound contrast agents:
properties, principles of action, tolerance, and artifacts. EurRadiol
lenta. Administrarea rapida este eficienta pentru ca realizeaza 2001:11:1316-1328
o concentrate ridicata sanguina, dar acuratetea imaginii poate 4. Zhou YJ, Man-Li Yuan, RuiLi, Li-PingZhu, andZhao-Hui Chen.
fi afectata de artefactele care rezulta uneori. Perfuzia lenta Real-Time Placenta! Perfusion on Contrast-Enhanced Ultrasound
asigura o concentratie moderata dar cu aspect ,,in platou" ceea and Paramedic Imaging Analysis in Rats at Different Gestation Time
ce permite evidentierea unui plus de detalii. Gazul se elimina and Different Portions of Placenta. PLoS One. 2013;8(4):e58986
pe cale respiratorie dupa cca. 15 minute de la administrare. 5. Lymberg B. Diagnosis and staging of colonic tumors by con-
iar invelisul, In functie de natura lui. se metabolizeaza hepatic ventional abdominal sonographv as compared with hid- rocolonic
sau se filtreaza renal. O parte a AC se poate fixa In sinusoidele sonography. NEnglJMed 1992:327:65-69
sau sistemul reticulo - histiocitar din ficat sau splina ceea ce
duce la aparitia timpului ,,tisular" al explorarii. Microbulele
gazoase sunt bine tolerate de organism, doar In cazuri foarte 28.111. Tehnici ecografice speciale:
rare fiind semnalate reactii alergice de intensitate scazuta. armonici, tridimensional, elastografie
O particularitate a agentilor de contrast gazosi o constituie
faptul ca pot sa fie administrati si pe cale orala sau anorectala, Radii Ion Badea
prin diluare in apa. Administrarea orala combinata cu exa-
minarea in ,,modul contrast" permite o mai buna vizualizare Armonici. Explorarea ecografica folosind ecouri cu
a lumenului digestiv. frecvente diferite de cele ale fasciculului incident se numeste eco-
Indicatii. Examinarea ecografica cu contrast (CEUS grafie ,,armonica". Avantajele utilizarii ecourilor armonice sunt:
= contrast enhanced ultrasonography) este indicata pentru - a. rezolufie superioara ecourilor fundamentale, prin
evaluarea patului circulator capilar (in scopul detectarii ano- faptul ca au o frecventa inalta;
maliilor circulatorii congenitale sau dobandite, ex. inflamatii, - b. capacitatea de a fi discriminate de ecourile funda-
shunturi arterio - venoase, ischemii, necroze, angiogeneza mentale cu ajutorul unor echipamente speciale, permitand
neoplazica) si pentru evaluarea permeabilitatii lumenului astfel vizualizarea exclusive a unor detalii, ex.: ecografia cu
vascular la nivelul arterelor sau venelor. contrast i.v. (CEUS).
Principalele aplicatii clinice ale CEUS sunt: caracteri- Armonicile sunt utilizate in vizualizarea tisulara (THI =
zarea tumorilor (cu precadere hepatice dar si la nivelul altor ,,tissue harmonic imaging") sau in vizualizarea curgerilor san-
organe), aprecierea eficientei terapiei tumorilor, identificarea guine (CEUS = ,,contrast enhanced ultrasonography"). THI
necrozelor de parenchim, evaluarea anevrismelor, detectarea are aplicatii pentru vizualizarea structurilor tisulare profunde
extravazarilor sanguine In seroase, dirijarea unor proceduri (ex. pacienti cu obezitate pronuntata). CEUS este folosita in
interventionale. Agentii de contrast pot sa fie utilizati si evaluarea patului circulator capilar si a trunchiurilor vasculare
pentru evaluarea lumenului digestiv sau al cailor urinare prin mari/medii in situatii normale si patologice.
instilare pe cai naturale. Explorarea ecografica tridimensionala (3D/4D).
Contraindicatii. Restrictii in administrare. Adminis- Este o procedure ultrasonografica evoluata, folosita curent
trarea e contraindicata la pacientii cu boli cardiace severe, in obstetrica. In ultimii ani a cunoscut o serie de aplicatii
dar nu exista riscuri la pacientii cu insuficienta renala sau la non -obstetricale, inclusiv cardiace. Metoda se bazeaza pe
cei cu hipersensibilitate la iod. Nu este acceptata adminis- obtinerea concomitenta a doua planuri sectionale dispuse
trarea la copii sau la femei In timpul sarcinii si alaptarii, desi perpendicular si, aproape instantaneu, o reconstruire a celui
studiile desfasurate pe animale gestante nu au aratat reactii de-al treilea plan, denumit coronal, dispus perpendicular pe
Radiologie imagisticd medicala

celelalte doua. Un echipament care permite realizarea celor timp real care necesita o compresiune intermitenta, de mica
trei planuri sectionale are capacitatea de a ,,construi" intr - un amplitudine, in scopul obtinerii unei imagini valide. Deoarece
timp ulterior (examinarea 3D ,,conventionala") sau concomi- procedura este operator dependenta echipamentele prezinta
tent (explorarea 4D sau ,,real time 3D") un volum (denumit pe ecran un indicator de calitate care trebuie atins pentru
„ voxel") prin ,,pozitionarea" in spatiu a tuturor elementelor ca investigatia sa fie considerata corecta. Elastografia color
reflectante identificate. Aspectul este acela de structura poate fi interpretata doar dupa obtinerea unei harti de culoare
spatiala foarte apropiata ca imagine de ceea ce este organul valide calitativ si stabile, constante din punct de vedere al
explorat in realitate. Avantajul tehnicii 3D/4D este acela de alocarii culorilor. Astfel pentru > 80% din imaginile obtinute,
a putea ,,manipula" volumul reconstruit atat prin retire cat si echipamentul trebuie sa aloce aceeasi culoare, in mod con-
prin proceduri speciale de substractie de imagine pentra extra- stant. Ulterior, formatiunea tumorala se poate caracteriza si
gerea de trasaturi caracteristice. Examinarea 3D/4D este utila semicantitativ prin strain ratio (SR), care, este raportul de
pentru recunoasterea anomaliilor fetale si pentru identificarea elasticitate dintre doua tesuturi alese prin fixarea manuala a
mai precisa a sexului fetal. Exista aplicatii ale metodei 3D/4D ROI: unul cu elasticitate cunoscuta iar celalalt cu elasticitate
in oncologie, pentru calcularea exacta a volumului tumoral, necunoscuta, nedeterminata. Elastografia color si-a demon-
precum si in toate situatiile in care o regiune de interes este strat aplicabilitatea si utilitatea in multiple domenii clinice,
inconjurata de lichid ceea ce permite un contrast foarte bun in primul rand oncologia.
al imaginii, de ex. tumori intravezicale sau mase intrachisti-
ce. Ecografia 3D/4D este utila pentru precizarea distributiei
spatiale a unor structuri vasculare sau a topografiei tumorilor Bibliografie
hepatice care au contrast suficient de mare fata de parenchi- 1. Bums PN, Powers JE, Hope Simpson D, UhlendorfV, Fritzsch T.
mul hepatic. Examinarea 4D a cordului permite vizualizarea Harmonic imaging: principles and preliminary results. Angiology
concomitenta a jeturilor sanguine intracardiace normale sau 1996:47:63-73
patologice. Desi are la baza o tehnologie complexa, ecografia 2. Dietrich CF. 3D Abdominal Sonography. Electromedica 69
3D/4D nu aduce beneficii in ce priveste rezolutia imaginii dar (2001) no. 1, 23-29
permite o mai buna intelegere a raporturilor spatiale dintre 3. Bomber J et al. EFSUMB guidelines and recommendations on
diferitele structuri anatomice. the clinical use of ultrasound elastography. Part 1: Basic principles
Elastografla. Odata cu aparitia elastografiei, ecografia and technology. Ultraschall Med 2013;34:169-184
4. Havre RF, Waage JR, Gilja OH, Odegaard S, Nesje LB. Real-
a devenit o ,,prelungire" a simtului clinic, intarand si con-
Time Elastographv: Strain Ratio Measurements Are Influenced by
firmand diagnosticul final. In functie de echipament si de the Position of the Reference Area. Ultraschall Med 2011; Jim 10,
modul de masurare a elasticitatii tisulare. elastografia este doi: 10.1055/S-0031-1273247
de doua tipuri: tehnica color (SE = strain elastography) si 5. Cosgrove D, Piscaglia F, BamberJet al. EFSUMB Guidelines and
elastografia bazata pe unde de forfecare (elastografia ARFI Recommendations on the Clinical Use of Ultrasound Elastography.
si elastografia ,,shear wave" - SWE). Elastografia ARFI si Part 2: Clinical Applications. Ultraschall Med - Eur J Ultrasound.
SWE sunt metode cantitative, avand aplicatii clinice pentru 2013;34(03):238-53
evaluarea fibrozei hepatice, in primul rand, dar si al altor
organe. Elastografia color in timp real (ES) este cea mai
accesibila dintre toate tipurile de elastografie, fiind o metoda
calitativa, care reprezinta rigiditatea tisulara pe harp de culoa-
re. In functie de transductor. echipament si zona examinata.
pentru achizitionarea unei imagini valide, poate fi necesara
o compresiune externa intermitenta asupra transductorului.
Tesuturile, in functie de elasticitate, sunt reprezentate pe o
scara de culori de la rosu la albastru. Acest tip de elastografie
permite compararea rigiditatii unor structuri tisulare aflate
in contact sau apropiate (variatia tensiunilor tisulare sau rata
de compresibilitate - ,,strain ratio" - SR). Pentru calcularea
cat mai corecta a SR, este important ca cele doua regiuni
de interes (ROI) sa fie la o distanta similara de transductor,
apreciata pe verticala. Elastografia color este o metoda in
Partea a 5-a

Substantele de contrast

Bibliografie
1. Bush WH, Bettmann MA. Update on metformin (Glucophage®) therapy and the risk of lactic acidosis: change in FDA-approved package
insert. ACR Bulletin 1998:54:15
2. ** - Manual on Contrast Media, Edition 7.0, American College of Radiology - 2010:33-35
3. Younathan CM, Kaude JV, Cook MD, Shaw GS, Peterson JC. Dialysis is not indicated immediately after administration of nonionic
contrast agents in patients with end-stage renal disease treated by maintenance dialysis. AJR Am JRoentgenol 1994:163:969-71
4. Marcos SK, Thomsen HS, Webb JAW, and members of the Contrast Media Safety Committee of the European Society ofUrogenital
Radiology (ESUR). Dialysis and Contrast Media. Eur Radial 2002:12:3026-3030
I Capitolul 1. Principii ale tehnologiilor imagistice 51

29. Notiuni despre structure moleculara etatea de a fi transsonica), sunt molecule mucopolizaharidice
(MPZ) structurate ca o membrana injurul unormici cantitati
si farmacologia substantelor de contrast; de gaz. Aceste mici bule gazoase cu perete MPZ sunt puse in
clasificarea substantelor de contrast radi- vibratie elastica (se contracts si se destind sub influenta unui
ologice, de RM si ecografie; concentratiile ultrasunet puternic), generand turbulen|a la nivelul vaselor
in care sunt prezente. Astfel, ecoul ultrasonor receptionat de
si dozele substantelor de contrast intra- la nivelul structurilor vasculare va fi amplificat pozitiv dar si
venoase; alegerea celui mai bun mediu de diferentiat in functie de gradul de vascularitate.
Rezonanta magnetica foloseste de asemenea substante
contrast si folosirea optimala a acestuia de contrast digestive, sub forma de apa in suspensie cu diverse
in relatie cu tehnica imagistica aleasa si structuri chimice care ii reduc absorbtia (manitol, PEG). Con-
problemele clinice ale pacientului. trastul intravenos folosit in IRM se bazeaza pe continutul unui
metal cu proprietati paramagnetice (de regula Gadolinium,
Adrian Santa mai rar Mangan sau Fier), care modifica dramatic timpul de
relaxare a structurilor cu vase active in care contrastul este
Termenul generic de ,,substanta de contrast" se refera la vehiculat. Exista si substante de contrast hepatospecifice,
utilizarea in imagistica medicala a unor medii sau substante fie Tl (gadolinium in molecule liposolubile) fie T2 (SPIO,
ce modifica aspectul imagistic al structurilor pacientului, fiind USPIO), utile in evaluarea parenchimului hepatic (a se vedea
astfel un adjuvant de diagnostic. Exista substante de contrast subiectul 165).
naturals, substante de contrast cu administrate digestiva Prin variabilitatea lor, substantele de contrast utilizate in
(antero - orala sau retrograda - anala). necesare evaluarii imagistica medicala nu pot fi discutate intr-un singur grup,
lumenului digestiv, substante de contrast intravasculare (ce ele necesitand discutie separata.
se injecteaza intravenos sau intraarterial), fiind vehiculate de Administrarea de contrast si in special cea intravasculara
torentul sanguin si generand astfel fie imagini ale lumenului trebuie sa respecte reguli precise. Dozele sunt specificate de
vascular (arteriografii, flebografii), fie ale organelor sau producator §i nu trebuie depasite, existand riscuri legate de
structurilor patologice cu vascularizatie activa. efecte secundare, in special renale.
Substantele de contrast cu administrare intravenoasa pot Concentratiile sunt specificate de producator. Acolo unde
fi specifice metodelor radiologice (radiologie conventionala, exista concentratii diferite pentru acelasi tip de mediu de con-
vasculara sau CT), respectiv metodelor neradiologice (eco- trast (ex contrast i.v. cu continut de Iod la 180 mgl/mm, 240
grafie si IRM). Exista si contrast injectat direct in caile biliare mgl/ml, 300mgl/ml, 350 mgl/ml si 400mgl/ml), trebuie tinut
sau in sacul meningeal rahidian, respectiv retrograd in vezica cont atat de obUnerea unui contrast cat mai mare (necesitand
urinara si caile urinare extrarenale (cistografie retrograda), doza de iod crescuta), cat si de vascozitatea substantei (care
mai rar folosite astazi. creste cu cresterea concentratiei de iod).
Structura chimica a mediilor de contrast variaza in Alegerea substantei de contrast este apanajul medicu-
functie de tip si utilizare. Daca radiologia conventionala lui radiolog si nu poate fi hotarata si nici sugerata de alte
foloseste metale grele (Bariu sau lod) pentru contrastul specialitati medicale. Responsabilitatile medicale si medico-
digestiv, substantele de contrast injectabile pentru metodele legale ce decurg din utilizarea substantelor de contrast sunt
ce utilizeaza radiatia X (urografie, CT, angiografie) vor avea de asemenea apanajul exclusiv al radiologului.
in compozitie ioni de metale grele (lod), legate de molecule Prin specificitatea lor, substantele de contrast trebuie
organice care asigura anumite proprietati, printre care cele alese adecvat metodei (CT, US, IRM) si tipului de examinare
legate de ionicitate si de osmolaritate. Ideal, contrastul cu iod preconizat. De asemenea, dinamica examinarii postcontrast
utilizat intravenos in radiologie ar trebui sa fie non-ionic (sa nu trebuie adaptata tipului de rezultat dorit, radiologul trebuind
prezinte sarcina) si izo-osmolar (sa aibe aceeasi osmolaritate sa cunoasca exact timpii de evaluare postcontrast (arteriala,
cu plasma sanguina). Exista substante ionice si hiperosmolare portala si tardiva de exemplu in cazul parenchimului hepatic).
(aproape scoase din uzul medical actual), substante non-ioni- Exista o multitudine de probleme legate de pacient care
ce si hiperosmolare (cele mai utilizate azi) si substante non- necesita atentie si trebuie cunoscute de catre medicul ra-
ionicesi izoosmolare (inca foarte scumpe pentru uzul curent). diolog, fiind necesara documentarea din datele pacientului
Substantele de contrast folosite in ultrasonografie, pe inainte de administrarea de contrast. Alergia la iod sau alergia
langa cele luminale (de cele mai multe ori apa, ce are propri- incrucisata la alte substante medicamentoase poate constitui
52 Radiologie imagistica medicala

contraindicatie. Tot contraindicatii sau atentie deosebita o conectata prin tubulatura specifics la branula intravenoasa
necesitS pacientii cu tireotoxicoza, diabeticii pe tratament cu a pacientului, injectarea facandu-se la comanda manipula-
Metformin, mielomul multiplu, pacientii cu insuficienta rena- torului, dupS stabilirea volumului injectat (ml) si a ratei de
la (inaintea administrarii de contrast este necesara obtinerea injectare (ml/sec). Majoritatea tomografelor moderne si a
valorilor actuale de uree si creatininS ale pacientilor), gravi- aparatelor de IRM permit injectarea initials a unei cantitati
dele si mamele care alapteazS. mici de contrast, detectarea ei si corelarea intre intensitatea de
contrast la un moment dat intr-un vas ales de cStre examinator
(ex: aorta ascendents) si declansarea concomitentS a injectSrii
30. Fundamentele bolusului de contrast restului de contrast si inceperea examinSrii. Urmarirea de
catre softul tomografului sau al aparatului IRM a cresterii
si a ratei constante de administrare; fi- contrastului in acest ROI (Region Of Interest) stabilit de
ziologia excretiei renale a substantei de examinator si declansarea automatS a injectSrii si scanSrii se
contrast; curbele de incarcare in compar- numesc variat de la producator la producator (Bolus tracking,
Care Bolus etc). Astfel se asigurS timpii de examinare, corelati
timentele renale dupa administrarea de cu fiziologia vasculara efectivS a pacientului (ce depinde de
contrast intravenos frecventa cardiaca, debitul cardiac ventricular stang si alte
elemente vasculare).
Adrian Santa Majoritatea mjectoarelor folosite in imagistica prezinta
doua suporturi, pentru doua seringi (cap dual) ce permit injec-
Pentru a obtine un contrast adecvat, substanta de contrast tarea fie a doua cantitSti succesive de contrast, fie injectarea
trebuie injectata in cantitate, concentratie si rata adecvata. unui volum de ser fiziologic imediat ce injectarea bolusului
In functie de scopul urmSrit, cantitatea de contrast poate s-a incheiat, asigurand astfel un bolus de contrast mai com-
varia, concentratia acesteia de asemenea. Volumul este si pact, cu reducerea dispersiei contrastului. Volumul si rata de
el variabil, unele organe (in special sistemul nervos central, administrare este specifics examinSrilor s.i trebuie cunoscutS
care prin bariera hemato-encefalica retine contrastul mai mult pentru fiecare tip de examinare si chiar pentru tipul de pato-
timp in circulatia parenchimatoasa) necesitand cantitati mai logie urmarit (ex: studiul tumorilor pancreatice necesita timp
mici decat altele. arterial precoce, unele tumori fiind violent incarcate doar in
Este intotdeauna obligatoriu ca volumul de contrast sa acest timp arterial, ulterior parenchimul adiacent prezentand
fie administrat compact, intr-un volum numit ,,bolus" care incarcare similara, cu ,,disparitia" tumorii).
reprezinta o cantitate compacts de contrast ce se deplaseaza Substantele de contrast radiologice intravenoase si cele
prin vasele pacientului inainte de a fi diluata si disipata in generale IRM sunt excretate renal.
torentul sanguin. Asigurarea bolusului de contrast este o Pasajul substantei de contrast de la nivelul pStrunderii in
necesitate atat pentru un contrast evident, cat mai ales pentru rinichi prin artera renala si panS la eliminarea in caile urina-
a putea face evaluari dinamice in timp, necesare studiului re urmeaza o succesiune de tranzitie prin compartimentele
comportamentului diverselor organe sau structuri patologi- functionale renale, respectiv de colectare finals, succesiunea
ce fata de contrast si in timp. Astfel se pot alcatui curbe de avand o desfasurare in timp de regula simetrica stanga-dreapta.
intensitate-timp a incarcarii cu contrast, specifice diverselor Substantele de contrast folosite astSzi sunt excretate renal,
tipuri de patologie. Ca regula generals, structurile carioki- componenta lor de secretare fiind neglijabila. Trecerea la
netice, neoformatoare, prin vascularizafia lor abundentS de nivel glomerular din sange in sistemul de filtrare renalS este
tip endotelial, vor fi rapid si accentuat incarcate de bolusul dependents de un numSr de factori intre care osmolaritatea,
de contrast si de asemenea contrastul va fi rapid ,,spSlaf. O vascozitatea sau sarcina electrics a substantelor de contrast,
asemenea curbs cu wash-in si wash-out rapid este caracte- dar si dimensiunile moleculare etc. Rata de filtrare glomerula-
ristica malignitatii. Structurile benigne prezinta incarcare ra renalS este de asemenea esentiala. Concentratia de contrast
progresiva mai lentS in faza initials, cu mentinerea incarcarii joaca un rol important in examinarea imagistica.
lente in faza tardiva. TranzituI prin compartimentele renale. Imediat dupS
Asigurarea unui bolus constant de contrast se realizeaza injectare, concentratia de contrast intravascular este mare,
prin injectarea i.v. cu ajutorului unui dispozitiv numit injector urmand ca apoi sa scadS prin echilibrul intre cantitatea de
sau injectomat, compus dintr-un dispozitiv tip seringa auto- contrast si plasma ce se atinge in timp. In perioada de maximS
mata in care se incarcS substanta de contrast. Aceasta este concentratie, filtrarea glomerulara a contrastului este si ea ma-
Capitolul 1. Pnncipii ale tehnologiilor imagistice 53
xima, generand prezenta de contrast renal la nivel cortical in reprezinta molecule complexe organice care au atasat un
primele faze postinjectare. Imaginea de parenchim renal astfel numar variabil de atomi de Iod, unele monomerice, altele
obtinuta poarta numele de nefrograma, aducand atat indicatii polimerice. Prin lipsa incarcaturii electrice, aceste molecule
despre starea morfologica a corticalei (defectele de incarcare reprezinta un rise mult mai scazut pentru nefropatie indusa
evidentiind arii de corticala nefunctionala - infarct renal sau dar si pentru reactii de tip anafilactoid.
inlocuita de alt proces patologic - chist, tumora, abces), dar In functie de osmolaritatea lor fata de plasma sanguina,
si despre functia de excrete a acesteia (intarzieri uni- sau Substantele de contrast non-ionice pot fi hiperosmolare sau
bilaterale ale excretiei sau chiar lipsa totala a acesteia - rinichi izoosmolare.
mut urologic). Acest proces dureaza de regula 1-2 minute. Cele mai uzitate astazi in diagnosticul medico-imagistic
Trecerea substantei de contrast in sistemul colector (dupa prin metodele ce utilizeaza radiatia X sunt Substantele de
2-3-5 minute de la injectare) duce la incarcarea cu contrast contrast non-ionice hiperosmolare. Exista un numar de pro-
a sistemului calicial si ulterior a bazinetului. ureterelor si a ducatori de asemenea substante, ele fiind oferite in volume
vezicii urinare (la 15-25 min). Examinarea seriata succesiv si concentratii variate, de la flacoane de 10 ml la flacoane de
la intervale diferite de timp trebuie sa surprinda atat faza 200ml. concentratiile variind intre 180 mgl/ml si 400 mgl/
nefrografica, cat si cea tardiva, de colectare. Principiul este ml. Dozele administrate pacientilor depind atat de organul
valabil atat in urografia intravenoasa (in dramatica reducere examinat, cat si de concentratia de iod, existand indicatiile
de utilizare), cat si in Uro-CT. Avantajul Uro-CT rezida in producatorului. Ca exemplu, pentru examinarea CT crani-
obtinerea in acelasi timp de date functionale (nefrograma si ana sunt necesari 50 ml de contrast 300mgl/ml, pentru cea
urograma), dar si in evaluarea perfuziei strucrurilor patologice abdominala 100-120 ml, cantitati mai mari fiind necesare in
si a regiunilor extrarenale (organe abdominale, retroperito- evaluari angiografice sau de perfuzie.
neu), neexplorabile prin urografie. Doza unei Uro-CT poate Substantele de contrast non-ionice izoosmolare sunt cele
fi mai mica decat a unei urografii cu radiografie reno-uretero- mai reduse ca rise de reactii secundare, insa pretul lor este
vezicala simpla si 4-5 clisee postcontrast! in continuare mult mai mare decat al celor hiperosmolare.
Izoosmolaritatea reduce efectul toxic al contrastului asupra
celulelor si tubilor renali, reducand riscul de nefrotoxicitate
sau de nefropatie indusa cu contrast, aceste substante fiind
31. Principiile fiziologice, proprietatile utilizate la pacientii cu patologie a functiei renale, dar de
fizice, efectele adverse (biologice, toxice, asemenea sub controlul creatininei si ureei.
anafilactoide) ale substantelor de contrast Reactii la contrast
Substantele de contrast pot genera reactii biologice, reactii
radioimagistice ionice si non-ionice, ul- toxice si reactii anafilactoide. Desi mai reduse ca in cazul
trasonografice si a celor folosite in IRM substantelor radioimagistice cu continut de iod, si Substantele
de contrast utilizate in IRM (chelati de Gadolinium) pot pro-
Adrian Santa
voca astfel de reactii. Particular^ pentru mediile de contrast
IRM este fibroza sistemica nefrogena (apare la pacientii cu
Substantele de contrast radio-imagistice cu continut disfunctie renala).
de iod. Reactiile generate de contrastul administrat intravenos pot
Substantele de contrast cu Iod si cu incarcatura electrica fi usoare, medii si grave. De asemenea exista reactii imediate
se numesc substante de contrast ionice. Reprezinta primele (declansate la cateva minute postinjectare) si reactii tardive,
substante folosite pe scara larga in special in urografie, avand de regula mai putin grave in sensul amenintarii vietii.
azi doar interes istoric, nemaifiind folosite in practica medica- Senzatia de incalzire pe care unii pacienti o percep la
la moderna datorita unui nivel de rise mai inalt, legat atat de injectare nu este considerata reactie la contrast, fiind un
hiperosmolaritatea lor, cat si de faptul ca reprezinta molecule fenomen comun, fara urmari.
incarcate electric. Reactiile potential generate de acestea, pe Reactiile usoare se manifesta prin rash cutanat, prurit,
langa nefrotoxicitate cu necroza tubulara, nefropatie indusa aparitia de papule cu reversibilitate in timp scurt
prin contrast, sunt cele de tip anafilactoid, (usoare, medii si Reactiile medii pot implica edem facial sau glotic, anxi-
grave), cu rise de deces rapid prin soc anafilactic. etate extrema, dificultati respiratorii.
O a doua generatie de substante de contrast cu iod este Reactiile grave sunt reprezentate de socul anafilac-
reprezentata de Substantele de contrast non-ionice. Ele tic. Este de remarcat ca socul anafilactic este o reactie
54 Radiologie imagistica medicala

autointretinuta, care, prin mecanism histaminic, se propaga 32. Nefrotoxicitatea substantelor de con-
de la sine odata ce a fost initiata. In acest sens, declansarea
sa nu este dependenta de cantitatea de contrast administrata, trast; factor! de rise pentru nefrotoxicita-
putandu-se declansa si la cantitati mici, folosite pentru tes- te si identificarea pacientilor; metode de
tare. De aceea, testarea cutanata sau intradermica la contrast
prezinta aceleasi riscuri de declansare a socului. Este cruciala
reducere a riscului de nefrotoxicitate la
anamneza pacientului, pacientii cu istoric de reacfii la iod sau contrast; precautiile la pacientii diabetici
la alte medicamente, respectiv alimente, fund pacienti cu rise tratati cu Metformin care necesita admi-
(exista reactii incrucisate la diverse componente chimice),
si este de evitat administrarea de contrast. Ori de cate ori se nistrarea de contrast iv; fibroza sistemica
poate, acesti pacienti vor fi examinati ecografic cu contrast, nefrogena: definitie, aspecte clinice si
contrastul folosit in ecografie fiind Hpsit de reactiile generate
de iod sau chiar Gadolinium.
factori de rise; utilizarea contrastului cu
Un serviciu de imagistica trebuie sa aiba in dotare trusa Gadolinium la pacientii cu rise
de prim-ajutor antisoc, constand in atropina, adrenalina, Adrian Santa
hemisuccinat de hidrocortizon, cortizoni cu actiune rapida,
plasma expander! dar si laringoscop si sonde de intubatie de
dimensiuni diferite. Nefrotoxicitatea indusa de substantele de contrast repre-
Ca regula obligatorie, substanta de contrast se injecteaza zinta o forma iatrogena de insuficienta renala acuta. Pacientii
pe canula flexibila (branula, fiexula). care se pastreaza i.v. prezinta modificari ale creatininei serice sau modificari de
pana dupa terminarea examinarii, chiar si mai mult daca clearance al creatininei de obicei intre 1 si 5 zile postadmi-
nistrare de contrast.
pacientul este internal. Aceasta conduita asigura pastrarea
Mecanismul de producere al nefrotoxicitatii postadmi-
abordului venos pentru tratament, stiut fiind faptul ca socul
nistrare de contrast i.v. nu este in intregime cunoscut si nici
anafilactic se insoteste de plegie vasculara periferica. cu
prevalenta acesteia, fiind multe cazuri ce nu se raporteaza,
cvasiimposibilitatea abordarii venoase percutanate prin
pacientii revenind la valori normale fara tratament de dializa
punctie venoasa.
sau chiar fara orice tratament. Se considera ca la baza feno-
In lipsa tratamentului rapid si energic (care implica dese-
menului sta obstructia tubulara prin precipitare de oxalati,
ori anestezist-reanimator), decesul prin soc anafilactic poate
urati sau proteine, insa exista cercetatori care nu considera
surveni chiar si in mai putin de 5 minute.
real acest mecanism, considerand ca se produce un grad de
Pe langa reactiile alergice, substantele de contrast se uti-
ischemie la nivel medular renal, indusa direct de substanta de
lizeaza cu precautiune sau de loc la pacienti cu tireotoxicoza,
contrast. Aceasta provoaca natriureza si cresterea necesaru-
boli grave hepatice, insuficienta renala (vezi capitolul urma- lui de oxigen local, concretizata prin aparitia vasodilatatiei,
tor), pacienti cu tratamente medicamentoase ce contraindica a eliminarii de prostaglandine si acid nitric. Pacientii cu
administrarea de contrast dar si la pacienti cu boli hemato- rise crescut nu raspund corespunzator, generand in schimb
logice care pot elibera proteine ce impieteaza filtrarea renala vasoconstrictie intensa si de lunga durata, cu aparitia ischemiei.
(proteinuria Bence-Jones din mielomul multiplu). Principalele riscuri pentru producerea nefrotoxicitatii in-
duse prin contrast sunt cele legate de pacientii cu insuficienta
renala, deshidratare, insuficienta cardiaca.
Pentru evitarea aparitiei nefrotoxicitatii, selectia
pacientilor trebuie sa fie riguroasa si la fel pregatirea aces-
tora. Astfel, pacientii sunt hidratati atat inaintea, cat si dupa
examinarea cu contrast i.v., chiar prin perfuzie intravenoasa
daca e nevoie, de 1 ml/kgcorp/ora timp de 12 ore. Unii autori
sugereaza si folosirea in perfuzia salina a unor mici cantitati
de Manitol, Furosemid sau Felodipina. Este obligatoriu, in
special in examinarile in care cantitatea si rata de contrast
sunt mari (angioCT), dar regula se poate aplica tuturor
pacientilor, ca inaintea examinarii cu contrast sa se verifice
valorile de uree §i in special de creatinina serica, ce nu tre-
Capitolul I. Principii ale tehnologiilor imagistice 55

buie sa depaseasca 1,5 mg/dl. Alti autori sugereaza ca limita


valoarea de 1,8 mg/dl.
Dializa postadministrare de contrast este utila, dar exista
si riscuri legate de aceasta, unii autori sugerand ca este mai
utila dializa inaintea procedurii decat dupa aceasta.
Pacientii diabetic! care sunt sub tratament cu Metfor-
min (Glucophage) prezinta rise crescut la administrarea de
contrast i.v. Motivul este excretia renala a Metforminului,
nefropatia indusa prin contrast determinand la acesti pacienti
acumularea de Metformin la nivel renal si precipitarea aces-
teia, asociata cu lactacidoza.
La acesti pacienti, tratamentul oral cu Metformin va fi
intrerupt pentru 48 ore DUPA administrarea de contrast
(ghidurile actuale nu solicita intreruperea tratamentului INA-
INTEA) examinarii cu contrast. Valorile de creatinina serica si
clearance vor fi monitorizate in primele 5 zile postcontrast.
Fibroza sistemica nefrogena
Fibroza sistemica nefrogena este o stare patologica rara
dar grava, produsa de administrarea de contrast la unii pacienti
cu insuficienta renala, in special la pacienti de varsta medie,
dar si la copii sau varstnici.
Boala se manifesta prin fibroze tegumentare sau ale altor
regiuni si tesuturi, fiind o boala sistemica, generalizata.
Pacientii considerati ,,de rise" sunt in general pacienti cu
insuficienta renala cronica supusi dializei si care au o rata de
filtrare glomerulara mai mica de 30, la care se administreaza
substante de contrast ce contin Gadolinium.
FDA (Food and Drug Administration - USA) considera
ca pacienti de rise persoanele peste 60 ani, pacienti cu isto-
ric de patologie renala inclusiv tumorala, istoric familial de
insuficienta renala, diabet insulino- dependent, hipertensiune
arteriala ce necesita tratament. mielom multiplu, transplant
de organ, boala hepatica grava. Conform FDA, doar acest
grup necesita evaluarea functiei renale inaintea administrarii
de contrast cu gadolinium. Se recomanda calculul eGFR,
obtinut din valorile creatininei serice si date ale pacientului
(varsta, rasa, sex si masa musculara) - exista tabele de calcul.
Pacientii cu eGFR sub 30 sunt considerati de mare rise, cei cu
valori intre 30-60 de rise scazut, cei cu valori peste 60 sunt
considerati cu rise neglijabil.
Pentru evitarea aparitiei bolii, pacientii de rise vor fi
exclusi de la administrare de contrast in cursul examinarii
IRM; daca acest lucru nu este posibil, se vor folosi substante
de contrast cu rise redus. FDA si ACR considera ca Gadodia-
mide, Gadopentate dimeglumine si Gadoversetamide prezinta
rise mai mare decat Gadobenat dimeglumin sau Gadoteriol.
Pacientii cu dializa de rutina isi vor continua sedintele
de dializa, in timp ce aceia care nu sunt dializati nu nece-
sita dializare postcontrast, aceasta nefiind o garantie pentru
neaparitia bolii.
Partea a 6-a

Informatica imagistica

Blbliografle
1. Dougherty G - Medical Image Processing - Techniques and Applications - Springer Science & Business Media, 2011
2. Bankman IN - Handbook of Medical Image Processing and Analysis, 2nd. Ed - Elsevier, Academic Press, Burlington, 2009
3. Suetens P - Fundamentals of Medical Imaging - 2nd Ed - Cambridge University Press, Cambridge, 2009
Capitolul 1. Principii ale tehnologiilor imagistice 59

33. Infrastructura informaticii ima- densitati), reconstruct!! in alte planuri, tridimensionale sau
cinematice.
gistice: sisteme PACS, RAS si datele Rolul unui sistem PACS, pe langa pastrarea datelor, este
electronice ale pacientului; standardele de a permite accesarea de la distanta a imaginilor (chiar §i prin
informatice (DICOM, HL7 si IHE); me- net, prin protocoale securizate VPN) atat pentru radiolog, cat
si pentru alte categorii de medici clinicieni. De asemenea, prin
tode e-learning (invatamant electronic); includerea tuturor datelor pacientului, permite compararea
aspecte relevante ale teleradiologiei si rapida si in acelasi timp, a unor examinari mai vechi, pentru
a stabili evolutia bolii in timp.
telemedicinei; notiunea de raportare IHE (Integrating the Healthcare Enterprise) este o
structurata organizatie non-profit ce sponsorizeaza initiative ale industriei
pentru imbunatatirea modului de schimb informational a da-
Adrian Santa telor medicale. IHE a creat si opereaza un proces prin care in-
teroperabilitatea sistemelor IT medicale pot fi imbunatatite.
DICOM (Digital Imaging and Communications in HL7 (Health Level 7) se refera la un set de standarde
Medicine) reprezinta formatul de imagine standard pentru Internationale pentru transferul informational al datelor clini-
manipularea, stocarea si transmiterea de imagini digitale. ce si administrative in sistemele informationale ale spitalelor
Formatul include definitiaformatuluifisierului de imagine si (HIS. RIS). Standardul HL7 permite comunicarea intre diver-
protocolulde comunicare. Protocolul de comunicare reprezin- sele calculatoare ale unei instirutii medicale, grupand datele
ta o aplicatie de protocol ce foloseste TCP/IP pentru comu- unui singur pacient, atat medicale, cat si contabile (note de
nicarea intre sisteme. Fisierele tip DICOM pot fi transferate plata, fisa de cheltuieli etc).
intre sisteme capabile sa citeasca protocol DICOM. HIS (Hospital Information System) reprezinta o retea
Protocolul DICOM este proprietatea NEMA (National intre computerele unei institutii, deseori functionand pe
Electrical Manufacturers Association), care detine patentul baza standardelor HL7 sau similare, integrand toate datele
pentru format si care a impus acest format ca standardul medicale si administrative ale spitalului. Poate include si
universal pentru imagistica. Formatul DICOM3, eel utilizat atasarea de fisiere DICOM, dar si informatii administrative
actualmente, mai este cunoscut ca PS3 sau ISO standard complexe legate de pacient.
12052:2006 RIS (Radiology Information System) reprezinta o baza
Rolul formatului este de a integra scanere (CT sau RM, de date computerizata folosita de departamentele de radio-
PET etc.) cu servere, statii de postprocesare, imprimante logie pentru depozitarea, manipularea, distribuirea datelor
si sisteme de retea produse de multiple companii, fiind un imagistice ale pacientului. Permite urmarirea, planificarea,
,,limbaj" unic si comun de imagine. raportarea datelor pacientului. legate de imaginile examinarii
Un fisier DICOM este mai mult decat o simpla imagine radiologice a acestuia. RIS este complementar sistemului HIS,
in harta de biti, diferind de formate grafice (jpg, bmp, tiff, fiind esential pentru stabilirea unui flux de lucru al pacientului
png) prin faptul ca include date de identitate ale pacientului, radiologic. Are proprietati de interogare si extragere (querry-
respectiv date legate de fiecare pixel din imagine permitand retrieve) prin care datele stocate sunt aduse pe un monitor.
prelucrare ulterioara a imaginii (modificare de fereastra, E-learning este un tennen generic ce se refera la posi-
largime de fereastra, masuratori de densitate, date ce permit bilitatea educatiei medicale (implicit si radiologice) prin in-
reconstructii in alte planuri sau tridimensionale. termediul internetului. E-learning (sau eLearning) reprezinta
Imaginile in format DICOM pot fi integrate in PACS utilizarea de media electronica si tehnologii informationale
(Picture Archiving and Communication Systems). si de comunicatie (ICT - Informational and Communication
Sistemele PACS contin doua elemente constructive: Technologies) in educatie. E-learning (in mod general) in-
serverul de date si statia de lucru. Serverul de date confine clude toate formele de tehnologie educationala in educatie
toate datele legate de pacient in format DICOM iar statia de si invatare. E-learning este sinonim cu multimedia learning,
lucru este de regula multipla, astfel incat datele pacientului technology-enhanced learning (TEL), computer-based
pot fi vizualizate in mai multe locuri din acelasi server. Statia instruction (CBI), computer-based training (CBT), com-
de lucru poate fi un viewer simplu de imagini, dupa cum puter-assisted instruction sau computer-aided instruction
poate fi mult mai complexa, avand veleitatile unei statii de (CAI), internet-based training (IBT), web-based training
postprocesare, permitand masuratori (distante, volume, arii, (WBT), online education, virtual education, virtual learning
Radiologie imagistica medicala

environments (VLB) (de asemenea cunoscute ca platforme 34. Principiile elementare ale procesarii si
e-learning), m-learning, si colaborarea educationala digitals.
Aceste denumiri alternative pun accentul pe cate un aspect postprocesarii de semnal; principiile sis-
particular, pe components sau metoda de transmitere. temelor liniare (convolutie, transformari
Formele de platforma e-learning includ CD-uri cu cur-
suri, cursuri video pe internet sau documente educationale
Fourier, Nyquist, restaurare de imagine
accesabile prin internet. si deconvolutie)
Telemedicina - teleradiologia reprezintS modalitatea Adrian Santa
de a exarm'na imagini radiologice de la distanta si de a
elabora rezultate ce pot fi retrimise la originea imaginilor,
locul efectiv de examinare. Metoda a fost dezvoltata initial Exists douS etape de prelucrare a datelor brute rezultate
in tSrile nordice, unde populajia redusa numeric in anumite din achizitie: procesarea si postprocesarea.
arealuri nu justifies mentinerea permanenta a unui radiolog, Procesarea este efectuatS de catre softul scannerului,
in aceste locuri izolate fund montat un aparat de imagisticS care transforms datele electrice de la senzori in imagini de
(radiologie sau de alt tip), respectiv un tehnician medical care regula in planul de achizitie. Aceste imagini pot avea aspecte
sa efectueze examinarea. Imaginile in format DICOM sunt diferite, ele fiind ,,filtrate" initial prin asa-numitele filtre de
trimise la spitale mai mari, unde sunt evaluate de radiolog si convolutie si kerneluri, care due la obtinerea de imagini cu
se elaboreazS un rezultat radiologie. accentuarea unor structuri (os, tesut moale, aer etc). Ele sunt
In evolutie, teleradiologia a ajuns sa fie folosita pentru a cuprinse in protocolul de scanare, pot fi modificate a priori,
doua opinie, pentru opinia unui specialist de nivel inalt intr-un meat rezultatul de imagine este intotdeauna acelasi pentru
anume domeniu sau chiar ca o metoda comerciala de obtinere acelasi tip de examinare.
de remuneratii pentru serviciul de examinare a imaginilor. Ulterior, din aceste date, examinatorul poate obtine ima-
Raportarea structurata se referS la problema legata de gini cu altS grosime de felie sau cu alte filtre de convolutie,
elaborarea rezultatului radiologie, stocarea si evaluarea ulteri- reconstruct^ care fac parte din postprocesarea de semnal.
oara a acestuia. Deseori, rezultatul are forma unui text simplu, Toate aceste date sunt exportate in statia graficS de lucru,
descriptiv, stocat impreunS cu datele de imagine. Reevaluarea unde examinatorul poate aduce noi modificSri imaginilor (a
acestuia necesita citirea intregului text si extragerea datelor se vedea subiectul 35).
relevante din acesta, variabilitatea individuals a fiecSrui Metodele de obtinere a imaginii in procesare si post-
raportor (medic radiolog) jucand un rol major in modul cum procesare sunt complexe, bazate pe prelucrSri matematice
este descrisa leziunea. Pentru eliminarea acestor particularitati (transformari Fourier rapide, limita Nyquist) pe care softul
individuale, exists notiunea de raportare structurata. In cadrul masinii le face farS interventia efectivS a examinatorului.
acesteia, informatia este standardizata, prezentatS organizat si Modul in care au loc aceste transformari si intelegerea lor
intotdeauna in acelasi mod, urmSrind invariabil la fel datele amSnuntitS necesitS cunostinte avansate de matematicS si nu
relevante (dimensiuni, forma, localizare etc), facand mult fac de regula obiectul instruirii medicale.
mai usoarS comparatia in evolutie. Un alt avantaj al raportarii Convolutia si deconvolutia sunt procese reciproce,
strucrurate se referS la timpul scurt necesar pentru elaborarea folosite in procesarea semnalului. ReprezintS prelucrSri
rezultatului, de regula sub formS de bifare sau adSugare de matematice care codeaza si reformeazS imaginea prin apli-
valori cifrice la un tabel de raportare. carea de algoritmi matematici complecsi (transformarea
Fourier este una dintre acestea). Rolul acestora este de a
obtine o imagine inteligibila pentru ochiul uman, cu corectii
de deformare optica, in acelasi timp pastrand coordonatele
spatiale ale elementelor achizitionate, astfel meat imaginea
sS prezinte o reciprocitate cat mai acurata cu realitatea bio-
losjica examinatS.
Capitolul 1. Principii ale tehnologiilor imagislice 61

35. Metode de analiza si procesare a ima- galben pentru cele cu wash-in mai lent si albastru pentru cele
cu wash-in foarte lent, astfel incat contrastul de culoare sa
ginii (reconstruct!! si analiza 2D si 3D, evidentieze ariile cu fluxul cu dinamica cea mai rapida (de
fuziune de imagine, realitate virtuala, regula maligne sau patologice), facandu-1 mai vizibil.
realitate augmentata, analiza functionala Alte posibilitati de prelucrare sunt cele de reformatare a
imaginilor in alte planuri decat eel de achizitie. Daca grosimea
si diagnostic asistat de calculator); prin- feliei are adancime egala cu dimensiunile in plan ale punctului
cipiile afisarii imaginii; calitatea imaginii de imagine (pixel), unitatea de volum (voxel) devine un cub.
Asemenea imagini se numesc imagini cu voxel izotropic (are
(zgomot, contrast, rezolutie si amplificare aceeasi dimensiune in toate planurile). Daca sectiunile au
de zgomot in timpul procesarii); princi- fost achizitionate in plan transversal, din asemenea ,,felii"
piile cuantificarii (Imagistica cantitativa izotropice se pot reconstrui imagini in plan coronal, sagital,
oblic. toate cu aceeasi rezolutie ca imaginile axiale primare.
- ROI, curbe de activitate in timp si ana- Aceste imagini poarta denumirea de MPR (MultiPlanar Re-
liza factoriala); principiile de procesare formatting). Reconstructive pot urmari un ax vascular sau
o anumita structura anatomica (coloana vertebrala, artere
a imaginii (detectarea marginilor, detec- coronare etc) obtinandu-se reformatari curbiliniare, un fel
tori, netezire, segmentare, reconstructie, de planiglob al imaginii curbe desfasurat in plan, ce permita
evaluarea precisa a aspectului anatomic
fuziune, inregistrare si afisare) De asemenea, in evaluarile cu contrast i.v, se pot ex-
Adrian Santa trage doar acele structuri care au densitatea contrastului
intravascular, cu ,,stergerea" celorlalte structuri din imagine
Imaginile medicale in format-masina (Raw data) sunt de si prelucrarea tridimensionala, obtinandu-se imagini de tip
regula exportate din aparatul de examinare in statii grafice angiografic, tridimensionale, ce pot fi rotite in jurul oricarui
de lucru, unde se petrece de fapt evaluarea de catre radiolog. ax pentru o mai buna analiza a lor. Se pot pastra in imagine
Pe langa procesarea primara facuta de catre electronica apa- doar structurile dense (MIP - Maximum Intensity projections)
ratului de examinare, medicul are la dispozitie numeroase sau cele mai putin dense (mlP - Minimum intensity projecti-
modalitati de imbunatatire si transformare a imaginilor pentru ons), obtinandu-se aspect tridimensional vascular cu contrast,
a obtine cat mai multe date medicale. Aceasta prelucrare a scheletal sau respectiv a tesutului pulmonar, a tubului digestiv
datelor primare se numeste postprocesare. cu continut aerie. Toate aceste noi imagini ce reproduc rea-
Modalitatile de postprocesare sunt foarte multe si foarte litatea tridimensionala a pacientului fac parte din categoria
complexe. Cele mai simple includ posibilitatea masurarii de de imagini numite Realitate Virtuala (VR- Virtual Reality).
dimensiuni, circumferinte, arii si volume. Datele DICOM Postprocesarea poate suprapune imagini provenite de la
contin informatii ce permit modificari de ferestre si nivel de aparate diferite daca coordonatele de imagine sunt identice.
fereastra ce sunt utile pentru vizualizarea mai buna a diferi- Astfel, imaginile de CT sau IRM pot fi suprapuse cu imagini
telor structuri (os, plaman, tesut solid in CT, efect de lupa si de medicina nucleara sau PET, proces numit fuziune de
accentuare de contrast in radiologie si mamografie etc.), dar si imagine. Aceasta permite localizarea anatomica a ariilor de
masuratori de densitate intr-un singur pixel sau prin definirea captare a radiotrasorilor, pentru un diagnostic de organ precis.
unei suprafete de interes (ROI-Region of Interest), in care se Statiile grafice cu programe dedicate pot urmari automat
pot face automat calcule de densitate medie, deviatie standard, anumite vase pe baza unor modele de comparatie existente
densitate maxima si minima in regiune si chiar histograme in memoria calculatorului, separand de exemplu coronarele
cu distributia densitatilor. si etichetandu-le automat ca descendenta anterioara, circum-
La utilizarea contrastului dinamic, aceeasi regiune ana- flexa si coronara dreapta, pentru a usura si grabi prelucrarea
tomica este ,,suprapusa" in cele cateva achizitii postcontrast, de imagine, segmentarea si etichetarea fiind laborioase in
examinatorul putand sa isi stabileasca regiune de interes in mod manual. Chiar daca softul face segmentare si etichetare
care se poate calcula graficul Incarcarii si spalarii de contrast automata, examinatorul poate interveni, corectand erorile de
in timp (curbe wash-in wash-out). Se pot obtine mape de co- aparat (redenumire, resegmentare sau aducerea in imagine a
dare in culoare a diferitelor arii in functie de comportamentul unor portiuni de imagine - de exemplu lumen vascular pe care
dinamic la contrast, ex: rosu pentru ariile cu wash-in rapid, softul le-a considerat gresit ca structura osoasa - densitatea
Radiologie imagistica medicaia

contrastului in vas si a corticalei osoase este uneori foarte


apropiata, pretand la eroare de sistem).
In mod automat sau manual, softul poate imbunatatii
imaginile prin efecte de iluminare sau de netezire a conturu-
rilor, facand perceptia cat mai buna (realitate augmentata),
imaginile cu ,,umbre" asemanatoare cu realitatea purtand
denumirea de SSR (Surface Shading Reformatting).
Toate imaginile obtinute prin postprocesare pot fi stocate
in format DICOM impreuna cu celelalte imagini native ale pa-
cientului, pot fi tiparite sau transmise in PACS, RIS, HIS.
Partea a 7-a

Notiuni de imagistica moleculara


Capitolul I . Principii ale tehnologiilor imagistice 65

36. Principiile de baza ale biologiei si este viu. Cand o celula stem se divide, fiecare noua celula
rezultata are potentialul fie de a ramane o celula stem, fie sa
biochimiei celulare: activitatea ADN si devina un alt tip de celula cu o functie mult mai specializata
ARN, metabolism, apoptoza si hipoxie; cum ar fi celula musculara, celula sanguina sau celula ner-
elemente despre migratia si diferentierea voasa. Datorita acestor calitati unice de regenerare, celulele
stem ofera posibilitati noi de tratament pentru diverse boli
celulelor stem. Principii elementare ale cum ar fi diabetul sau bolile cardiace.
metodelor de imagistica moleculara (PET, Hipoxia celulara reprezinta un deficit in cantitatea de
oxigen care ajunge in tesuturile vii. Cand utilizarea oxige-
microPET, microSPECT) si de imagistica nului de catre celule este compromisa procesele biologice
optica (fluorescenta, bioluminiscenta) se altereaza. Din acest punct de vedere, nivelul de oxigenare
tumorala este strans legal de agresivitatea tumorala. Astfel
Gabriel Andries s-a dovedit ca hipoxia joaca un rol major in progresia tu-
morala in procese cum ar fi: angiogeneza tumorala, rata de
Definitie: Imagistica moleculara este definita ca masura- mitoza celulara, metastazarea sau rezistenta la chimioterapie
rea si caracterizarea proceselor biologice la nivel celular si si radioterapie.
molecular utilizand diverse tehnici imagistice. AND, ARN si genomul uman. Intreaga informatie
Domeniul imagisticii moleculare este multidisciplinar genetica necesara formarii si sustinerii vietii este continuta
derivand din diverse specialitati: biologie moleculara, bi- in molecula de ADN (acidul dezoxiribonucleic). Acizii nu-
ochimie, fiziologie, fizica, inginerie, genetica, matematica, cleici sunt substance chimice macromoleculare cu grad inalt
chimie, farmacologie, imunologie si medicina. de polimerizare, formate prin inlantuirea unor molecule de
Pentru intelegerea modificarilor ce se produc la nivel nucleotide. Nucleotidele reprezinta unitatea monomerica a
celular si molecular este necesara cunoasterea notiunilor de acizilor nucleici si sunt compuse din: o baza azotata hetero-
baza ale biologiei si biochimiei celulare: ciclica, o pentoza si un radical fosforic. Ordinea acestor baze
Metabolism celular. Metabolismul celular reprezinta un reprezinta instructiunile inscrise in ADN sau codul genetic.
set de reactii chimice care apar in organismele vii cu scopul Ordinea bazelor azotate din secventa ADN formeaza genele
de a mentine viata. Metabolismul celular implica secvente care transmit celulelor cum sa produca proteinele.
complexe de reactii biochimice controlate cunoscute ca si me- - bazele azotate purinice - din structura acizilor nucleici
canisme sau cai metabolice. Aceste procese permit organis- sunt adenina (A) si guanina (G);
mului sa creasca si sa se reproduca, sa-si mentina structurile - bazele azotate pirimidinice - sunt reprezentate de timi-
si sa raspunda agresiunilor mediului inconjurator. na (T), citozina (C) pentru ADN si citozina (C), uracil (U)
Apoptoza este definita ca mecanismul de moarte celu- pentru ARN.
lara ce apare dupa ce celula a suferit suficiente deteriorari. Lanturi de aceste baze se asociaza intre ele (adenina si
Apare in cursul dezvoltarii si imbatranirii celulare si este timina, citozina si guanina) pentru a forma o structura care
considerata o components vitala a turnoverului celular, a seamana cu o scara. Acidul dezoxiribonucleic are o struc-
dezvoltarii celulare si a sistemului imun. Apare ca un me- tura de dublu helix. ,,Scara" este alcatuita din doua lanturi
canism de aparare, ca si o reactie imuna sau cand celulele organice elastice ce sunt conectate prin ,,treptele" realizate
sunt afectate de boli sau agenti toxici. Apoptoza patologica de legaturile de hidrogen. Intreaga scara este compactata
reprezinta un factor ce este intalnit in multe afectiuni cum ar in jurul altor proteine (implicate in mentinerea structurii si
fi: bolile neurodegenerative, afectiunile ischemice cardiace, reglarea expresiei genice) formand un cromozom. Colectiv,
boli autoimune sau diverse tipuri de cancer. Capacitatea de cele 23 de perechi de cromozomi dintr-o celula umana poarta
a modula moartea sau viata celulara este recunoscuta pentru denumirea de genom uman.
imensul potentialul terapeutic. Duplicarea moleculei de ADN este posibila prin ,,desface-
Celulele stem reprezinta un tip de celule ce au potentialul rea" secventei ,,de-a lungul" ei (se dezintegreaza ,,treptele")
de a se dezvolta in multiple tipuri celulare diferite in orga- prin actiunea unor proteine si o noua molecula este sintetizata
nism in perioada embrionara si de-a lungul cresterii. In plus, prin utilizarea ADN ca matrita. Aceasta noua molecula, ARN,
celulele stem servesc in multe tesuturi ca si un sistem intern actioneaza ca un sablon pentru produsele finale: proteine.
de reparare, acestea putandu-se diviza in esenta fara limite Sunt estimate cca. 80.000 de proteine care pot indeplini toate
pentru a mlocui celulele distruse atata timp cat organismul functiile de viata in interiorul si in afara celulei.
66 Radiologie imagistica tnedicala

Variatiile in ADN care predispun la boli pot exista de la ce contin un radioizotop emitator de pozitroni este administrat
nastere (defecte genetice) sau pot fi dobandite pe parcursul subiectului.
vietii (mutatii). Desi ADN-ul se va copia si va efectua sinteza - Pozitronul este emis defiecareagent imagistic de legare
proteinelor de nenumarate ori, greseli ocazionale in replicarea numai odata; acest pozitron parcurge o scurta distanta dupa
ADN-ului sau deteriorarea ADN-ului pot sa apara. In cazuri care interactioneaza cu un electron din tesuturile inconjura-
rare, echipamentul celular nu poate repara sau organismul toare, are loc un proces de anihilare din care rezulta productia
este incapabil de a elimina aceste greseli, si, ca urmare, a doua radiatii gamma fiecare cu o energie de 511 Kev, emise
boala apare - de exemplu, cancer. Cunoasterea secventei in doua directii opuse (la 180°).
genomului uman permite identificarea si intelegerea functiei - Dupa detectia radiatiilor gamma de catre detectorii
genelor umane. PET, localizarea procesului de anihilare este calculata pe
Prin cunoasterea secventei genomului uman, se pot dez- baza acumularii de multiple evenimente.
volta terapii specifice (proiectare rafionala de medicamente), - Semnalele electrice rezultate sunt convertite intr-o
care vizeaza proteine specifice (de exemplu, inhibited de sinograma care este apoi reconstruita intr-o imagine tomo-
proteaza, agonisti ai receptorului) sau va exista posibilitatea grafica.
de a manipula genele direct prin transferarea de gene noi sau Aceste imagini reflecta distributia agentului imagistic in
gene lipsa (terapie genica). corpul subiectului, deci ofera informatii despre procesele bi-
Elementele cheie necesare Imagisticii Moleculare sunt: ochimice pentru care agentul radioactiv a fost special marcat.
1) Probe imagistice cu specificitate crescuta si afini- - PET necesita existenta unui ciclotron pentru a produce
tate ridicata pentru tintele moleculare si transport radionuclizi cu timp scurt de injmnatatire cum ar fi: 18F
biologic acceptabil; (tl/2 = 109.8 min), 64Cu (tl/2 = 12.7 h), sau 11C (t 1/2 = 20.3
2) identificarea tintelor potrivite; min), 13N (tl/2 = 10 min), si 15O (tl/2 = 2.04 min)
3) strategii de amplificare adecvate; - scanerele Micro-PET au o rezolutie spatiala de -1-2 mm
4) sisteme imagistice sensibile si rapide cu rezolutie si o sensibilitate de ~ 10'" -10"12 mol/L
ridicata. - micro-PET poate fi utilizat pentru investigarea meca-
Numarul si densitatea semnalelor moleculare depind de nismelor fiziopatologice si moleculare in diverse boli utili-
tehnica imagistica utilizata si de procesul biologic ce este zand diversi agenti imagistici marcati radioactiv pe modele
investigat. animale
Pentru Imagistica Moleculara sunt utilizate in prezent - mai mult micro-PET poate fi folosit pentru evaluarea
cinci tehnici: (a) PET, (b) SPECT, (c) MRI, (d) Imagistica a noi agenti imagistici marcati cu radionuclizi emitatori de
optica si (e) ultrasonografia. pozitroni, eficacitatea unor noi terapii precum si biodistributia
PET si SPECT sunt tehnici imagistice moleculare ce unor noi medicamente pe modele animale
utilizeaza radionuclizi, fund capabile de a evalua modificarile Principii de baza ale micro-SPECT (Single Photon
biochimice si niveluri ale tintelor moleculare in subiectele Emission Tomography)
vii. Ambele tehnici nu au limite de penetratie si permit vizu- Tehnica SPECT utilizeaza radionuclizi cum ar fi 99mTc
alizarea proceselor/tintelor moleculare la nivelul intregului (tl/2 = 6 h), 1231 (tl/2 = 13.3 h), si lllln (tl/2 = 2.8 zile),
organism cu o mare sensibilitate. care se dezintegreaza prin emisia unei singure radiatii gamma
Imagistica Moleculara ce utilizeaza tinte marcate radio- cu energii diferite. Deoarece radionuclizii utilizati in SPECT
activ necesita de regula urmatoarele etape principale: difera de cei utilizati in PET, aparatura de detectie utilizata
- gasirea unor molecule care pot marca specific receptori este diferita (unul sau doi detectori care inregistreaza multiple
celulari solubili sau imobili, denumite liganzi; ..proiectii" care apoi sunt reconstruite)
- atasarea radioizotopilor care emit fotoni fara modifica- Schematic principiile de baza ale micro-SPECT pot fi
rea proprietatilor de legare biologice ale moleculelor |inta; si ilustrate dupa cum urmeaza:
- injectarea si obtinerea de imagini in vivo utilizand - Un agent imagistic SPECT marcat (conjinand un
aparate cu rezolutie si sensibilitate foarte inalte. radioizotop emitator gamma) este administrat subiectului
Principii de baza ale micro-PET iar radiatiile gamma sunt detectate cu ajutorul unei gamma
Schematic principiile de baza ale micro-PET pot fi ilus- camere (care se roteste in jurul subiectului)
trate dupa cum urmeaza: - Radiatiile gamma detectate sunt apoi reconstruite in
- In primul rand, un agent imagistic de legare (molecule imagini tomografice, oferind informatii despre localizarea
mici, peptide, proteine modificate, aptameri, nanoparticule) si distributia agentului imagistic in subiect
Capitolul !. Principii ale tehnologiilor imagistice 67
Dispozitivele micro -SPECT de ultima generatie permit In situ, fenomenul de fluorescenta este stimulat prin uti-
obtinerea de imagini cu o rezolupe spatiala mai mica de 1 mm. lizarea unei surse externe de excitare cu lumina vizibila cu
Principii de baza ale Imagisticii Optice lungimea de unda corespunzatoare.
Imagistica moleculara optica se bazeaza pe detectia Absorbtia la 489 nm produce fluorescenta iar la 508 nm
fotonilor vizibili si infrarosii dupa ce au fost transmisi catre fara administrarea nici unui agent exogen— produsul clonat
tesuturi biologice. Imaginile obtinute sunt rezultatul emisiei cu gena GFP induce fluorescenta.
de fotoni, a reflexiei, a absorbtiei, a imprastierii si a schim- Aspectele intensitatii emisiei de fotoni fluorescenti pot fi
barii de faza. captate prin tehnici digitale si apoi afisate Tntr-o scala gri sau
Avantajele Imagisticii Optice: sunt neinvazive, achizitia si color, indicand distributia sau activitatea proteinei.
observarea imaginilor in timp real, usor de efectuat, sunt ief- Imagistica prin fluorescenta este utila in evaluarea expre-
tine si cu minime efecte toxice asupra sistemelor biologice. siei genelor. monitorizarea interactiunilor proteina-proteina
Deoarece nivelele de energie ale atomilor care emit fotoni si in urmarirea populatiilor de proteine.
optici si infrarosii sunt foarte scazute, de la -1 la ~10eV,
penetrarea in adancime a tesuturilor este foarte redusa (eel
mult cativa cm). Bibliografie
Din aceasta cauza, tehnicile de Imagistica Optica sunt utile 1. James ML , Gambhir SS - A Molecular Imaging Primer: Moda-
numai pentru evaluarea geometriilor subtiri si au fost utilizate lities, Imaging Agents, and Applications. - Physiological Reviews
frecvent pentru masuratori in vitro sau pentru determinari 2012 Vol. 92, no. 2, 897-965
imagistice de suprafata in vivo pe animale mici. 2. Massoud TF, Gambhir SS - Molecular imaging in living subjects:
Principalele tehnici de Imagistica Optica sunt reprezentate seeing fundamental biological processes in a new light - Genes Dev.
de bioluminescenta si fluorescenta. 2003:17:545-580
Imagistica prin Bioluminescenta
Foloseste emisia de fotoni produsa biologic. Tehnica
foloseste luciferaza produsa de licurici, o enzima care este res- 37. Principiile contrastului tintit; notiuni
ponsabila de producerea luminii galben-verzui emisa de licurici.
Gena luciferazei, ex vivo, este clonata si introdusa in
privind substantele de diagnostic molecu-
ADN-ul unor celule specifice, care apoi sunt introduse in lar; tinte pentru Imagistica moleculara;
subiectul de studiu. trasori uzuali in Imagistica moleculara
Cu ajutorul unei surse biochimice de energie si a oxi-
genului, luciferaza produce o reactie de catalizare care are Gabriel Andries
ca rezultat generarea de fotoni de emisie galbeni spre verde
(aprox.500 nm). Un agent de imagistica moleculara este format din trei
Dispozitivele imagistice pentru bioluminiscenta sunt componente: o componenta chimica care asigura specificitate
disponibile pentru probe de dimensiuni mici. pentru o anumita tinta de interes; o componenta care va pro-
Imagistica Optica prin Bioluminiscenta este utilizata pen- duce un semnal ce poate fi detectat cu ajutorul unei tehnici
tru evaluarea expresiei genice, monitorizarea interactiunilor de imagistica; un linker.
proteina-proteina, urmarirea celulelor canceroase precum si Scopul principal al unui agent de imagistica moleculara
imagini de corp intreg ale animalelor mici. este de a interoga si de a raporta cu privire la un obiectiv
Imagistica prin Fluorescenta specific (sau obiectiv) de interes in timpul unui studiu de
Cel mai frecvent utilizat agent optic fluorofor este Proteina imagistica moleculara.
fluorescenta verde (GFP). Tehnica presupune utilizarea unor In majoritatea strategiilor de Imagistica Moleculara
dispozitive ce contin o serie de detectori (charge-coupled de- agentii imagistici trebuie introdusi in corpul subiectului
tector - CCD) care pot achizitiona si procesa imagini obtinute (injectare in sistemul circulator).
de la tesuturi intens autofluorescente. Tintele moleculare sunt reprezentate de: receptori celulari,
Imagistica GFP s-a dezvoltat dupa descoperirea si izolarea transportori sau enzime, proteine sau ARN.
acestei proteine fluorescente produse de catre meduze. In mod ideal, un agent de imagistica moleculara ar trebui
Gena producatoare de GFP este inserata intr-o constructie sa aiba urmatoarele caracteristici: raportul bun de fixare spe-
genetica ce este apoi incorporate in ADN-ul celulei ce ur- cifica, selectivitate mare de legare pentru procesul biochimic/
meaza sa fie studiata. substratul de interes, farmacocinetica adecvata, stabilitate
68 Radiologie imagislicd medicala

in vivo excelenta (metabolismul nu ar trebui sa afecteze [18F] fluorothymidine ([18F] FLT), un radioligand specific
negativ fixarea specifica), un profil de siguran^a bun (lipsa PET utilizat pentru a vizualiza activitatea timidinkinaza 1
de toxicitate la subiect), potential pentru translate clinica, ca o masura de proliferare celulara. Izotopii PET, cum ar fi
timp si cost de sinteza rezonabil, amplificarea semnalului si 11C si 18F sunt considerati a fi unii dintre cei mai potriviti
capabilitati de multiplexare. candidati pentru etichetarea lor ca molecule mici, datorita
Tipuri curente de agent! imagistici disponibili dimensiunii lor reduse (un atom).
Exista numeroase categorii de agenti de imagistica mole- b. Peptide
culara inclusiv molecule mici, peptide, aptameri, anticorpi cu - Peptidele pot fi sunt usor modificate, avand dimensiuni
greutate moleculara mare, fragmente de proteine modificate destul de mici (pana lal 5 aminoacizi), si sunt eliminate rapid.
genetic si diferite nanoparticule. Fiecare tip de agent se in- Peptidele au numeroase avantaje cum ar fi selectivitatea si
cadreaza intr-un interval de marime diferita si astfel poseda specificitatea superioara si de asemenea, flexibilitatea lor in
diferite proprietati farmacocinetice si de legare. ceea ce priveste modificarile chimice care pot fi tolerate fara
La fiecare clasa in parte exista agenti imagistici care pot fi a modifica proprietatile de legare sau cinetica.
folositi pentru ,,imagistica directa" iar altii pentru ,,imagistica Agenti imagistici peptidici pot fi folositi pentru a vizua-
indirecta". liza o serie de tinte, inclusiv integrine, metaloproteinazelor
Imagistica directa implica utilizarea unui agent care matriceale, caspazele, receptorii pentru somatostatina.
este oriental spre o tinta moleculara specifica, cum ar fi un c. Aptameri
receptor, transporter, sau enzima [de exemplu, [11C]-WAY Aptamerii potfi definiti ca oligonucleotide ADN sau ARN
100635 se leaga direct la receptorul serotonina-2A (5HT-2A), cu un singur fir care se leaga de site-ul lor tinta cu un grad
care este utilizat pentru imagistica acestui site]. ridicat de specificitate si selectivitate. Aptamerii sunt utilizati
Imagistica indirecta este un sistem mai generalizat care de curand in analize de laborator in vitro inlocuind anticorpii.
poate fi utilizat pentru a obtine imagini a mai multor procese In domeniul terapeutic, aptamerii au inceput sa fie utilizati din
biologice diferite, cu aceeasi tehnica de baza. 2004, pentru tratamentul degenerescentei maculare.
Agentii de imagistica moleculara pot fi, de asemenea, d. Anticorpi si proteine modificate genetic
clasificati ca agenti ,,activabili" sau ,,de semnalizare con- Anticorpii monoclonali (mAbs), cunoscuti sub numele
tinua". de imunoglobuline, sunt proteine in forma de Y, extrem
Agenti de imagistica activabili (de asemenea cunoscuti de specializate si cu dimensiuni foarte mici (-150 proteine
ca ,,probe inteligente") elibereaza semnal numai cand kDa). Spre deosebire de molecule mici si peptide, mAbs nu
interactioneaza sau se leaga de tinta. Un exemplu de agent se limiteaza la interactiunea cu site-rile de legare sau zonele
imagistic activabil este reprezentat de un agent optic care active, ci pot lega moleculele de adeziune, markeri de acti-
emite semnal fluorescent numai dupa scindarea enzimatica vare, antigene si receptori.
de cathepsin cistein proteaza. Pe de alta parte, agentii care In prezent, exista peste 20 de agenti terapeutici cu anti-
emit continuu produc constant un semnal (de exemplu, toti corpi monoclonali aprobati de FDA si mai mult de 8 anticorpi
agentii marcati radioactiv). monoclonali radiomarcati aprobati pentru imagistica molecu-
Principalele clase de agenti imagistici sunt: lara SPECT. Primul agent Acm aprobat imagistica moleculara
a. Moleculele mici a fost [11 Un] pendetidesatumomab (OncoScint) in 1992). In
- Dimensiunile mici ale acestor entitafi chimice (de obicei 1996 ambele [99mTc] arcitumomab (CEA Scan) si [Him]
< 500 Da) inseamna ca pot accesa si produce imagini pentru pendetidependetide (PROSTASCINT) au fost aprobate,
o gama larga de tinte moleculare (inclusiv intracelulara si urinate de [ 111 In] ibritumomabtiuxetan (Zevalin) in 2002 si
obiective SNC). [1311] tositumomab (Bexxar) in anul 2003.
- Exista doua tipuri principale de molecule mici utilizate e. Nanoparticule
ca agenti imagistici moleculari: Nanoparticulele sunt in curs de dezvoltare ca un nou set
1) molecule care se leaga de receptori specifici, transpor- interesant de agenti imagistici, ce pot fi directionate atat activ
tatori sau canale de ioni, de exemplu, [11C] PK11195 este un cat si pasiv. Au dimensiuni de ordinul a ~ 10-1 OOnm si nu mai
radioligand PETcare se leaga la receptorul periferic al benzo- mare de 1000 nm. In general vorbind, nanoparticulele sunt
diazepinelor (PBR) si este utilizat pentru a vizualiza microglia mai mari decat multe proteine si molecule mici, dar ele sunt
sau inflamatii neuronale in numeroase boli cerebrale. mai mici decat celulele.
2) molecule care permit imagistica metabolismului / a Datorita numarului mare de fragmente atasate la suprafata
activitatii enzimatice /transport, de exemplu, 3'-deoxi-3'- nanoparticulelor, acestea au o sansa mai mare de legare la
Capitolul 1. Principii ale tehnologiilor imagistice 69

tinta. Fiind capabile sa transporte o sarcina utila terapeutic sau nanomoli) de radiotrasor in pacient, acesta se distribuie
nanoparticulele au potenfialul de a reduce efectele secundare in diversele organe si sisteme.
nedorite ale multor terapii (de exemplu, chimioterapice), ca PET-CT: Integrarea unui PET cu un CT intr-o singura
molecule de droguri pot fi livrate la zonele bolnave intr-o unitate (PET-CT) a devenit recent o importanta tehnica
maniera site-specifica. imagistica in practica clinica. Sistemul integral PET-CT s-a
1. Nanotuburi de carbon cu un singur perete (SWNTs) dovedit a fi mult mai sensibil si mai precis in localizarea si
sunt compuse dintr-o foaie grafen tubular. Dimensiunile caracterizarea diverselor leziuni comparativ cu PET sau CT
acestor particule cilindrice de carbon variaza si sunt usor de singure. PET-CT este un exemplu de imagistica hibrida.
controlat, dar pentm aplicatii biomedicale sunt in general Principiul fizic al imagisticii PET
de ordinul a cativa nanometri in diametru si cateva sute de - Agentii radioactivi utilizati in tehnica PET sunt produsi
nanometri in lungime. in ciclotron prin bombardarea elementelor stabile cu pro-
2. Nanoparticule de aur (AuNPs) toni. deuteroni sau nuclei de heliu. Izotopii rezultaji contin
Doua tipuri comune de AuNP sunt utilizate ca agenji de un exces de protoni care se vor dezintegra prin emisie de
formare a imaginii: AuNPs sferice si nanoparticule de aur. In pozitroni.
functie de marimea lor, compozitie si pregatire, AuNPs poate - Este posibil sa fie produsi o multitudine de radioizo-
fi utilizat cu o gama de modalitati de imagistica, inclusiv topi emitatori de pozitroni, principala lor caracteristica fiind
RMN, CT, radionuclizi si tehnici optice. timpul de injumatatire scurt: 18-Fluor (TVi = 110 minute),
3. Nanoparticule de oxid de fier superparamagnetic 11-Carbon (T'/i = 20minute), 68-Galiu (T'/2 = 68min) etc.
(SPIOs). Nanoparticulele de oxid de fier superparamagnetic - Cu ajutorul izotopilor emitatori de pozitroni se mar-
(SPIOs) sunt proiectate special pentru studii de imagistica cu cheaza radioactiv diverse substarturi fiziologice (cea mai
ajutorul 1RM. Ele sunt constitute dintr-un miez de oxid de cunoscuta fiind marcarea cul8-F a Glucozei 18F-FDG).
fier (magnetit) acoperit cu un material cu matrice hidrofila. - Pozitronul emis de atomul radioactiv al radiotrasorului,
Ele produc contrast prin perturbarea campului magnetic local parcurge o distanta scurta prin tesuturi (1-2 mm) dupa care,
in care sunt plasate. la intalnirea cu un electron din vecinatate are loc o ,,reactie
Nanoparticulele (SPIOs) pot fi utilizate in imagistica re- de anihilare" insotita de emisia a doua radiatii gamma (fotoni
ceptorilorcelulari cumarfi Cy5.5-spio-clorotoxina specifica cu energia de 511 Kev) care sunt propagate la un unghi de
pentru matricea imagistica a metaloproteinazei 2, sau anti- 180° una fata de cealalta.
HER2-afflbody-conjugat-SPIOs pentru detectarea HER-2 Achizitia si reconstructia imaginilor PET
care exprima celulele canceroase. - Achizitia imaginilor PET se bazeaza pe detectia ,,in
coincidenta" (simultana) a celor doi fotoni gamma.
- Un scanner PET este format dintr-o multitudine de
Bibliografie detectori dispusi pe mai multe randuri de inele circulare
I.James ML, Gambhir SS.- A Molecular Imaging Primer: Moda- pozitionate in jurul pacientului. Pe durata examinarii sunt
lities, Imaging Agents, and Applications - Physiological Reviews, colectate milioane de ,,detectii in coincidenta" ceea ce ofera
2012:2:897-965 informatii despre distributia radiotrasorului in organism.
2. Massoud TF, Gambhir SS- .Molecular imaging in living subjects: - Achizitia imaginilor se realizeaza in mod 3D. Aceasta
seeingfundamental biological processes in a new light - Genes Dev. presupune ,,liniile de raspuns" (LOR) care sunt localizate in
2003;17:545-580 planuri oblice. Achizitia 3D are o probabilitate de detectie
mare, sensibilitatea fiind crescuta datorita utilizarii unor
cristale de scintilatie din materiale superioare (germaniu.
38. Principiul, analiza si procesarea bismuth sau lutetium). Acestea au o capacitate de detectie
imaginilor PET crescuta avand un ,,timp mort" scurt.
- In achizitia imaginilor sistemele PET si PET-CT poseda
Gabriel Andries metode software sofisticate utilizate pentru corectia atenuarii
si a ,,imprastierii" (scattering).
Definitie: PET (Tomografia cu emisie de pozitroni) este - Tehnica PET detecteaza evenimentele ,,in coincidenta"
o tehnica imagistica tomografica care permite evaluarea acestea fiind stocate intr-o sinograma. Sinograma contine
cantitativa noninvaziva a distributiei unui trasor radioactiv proiectiile tuturor unghiurilor de distribute a radioactivitatii
in vivo. Dupa administrarea unei cantitati foarte mici (pico in pacient.
70 Radiologie imagistica medicala

- Reconstructia imaginilor presupune utilizarea unor


algoritmi matematici analitici (filter back-projection-FBP)
sau a unor metode de reconstructie iterative (Ordered subset
expectation maximisation-OSEM)
Principii de baza in explorarea PET cu [18]F-fluoro-
deoxyglucose (FDG):
- Una din caracteristicile biochimice a celulelor tumorale
este o rata crescuta a consumului de glucoza datorita unui
numar crescut de transportori proteici ai glucozei (Glut-1 si
Glut-2). Aceasta rata mare a glicolizei in celulele maligne fa-
ciliteaza detectia utilizand imaginile PET FDG. Captarea FDG
in celulele maligne depinde de: integritatea vasculara,rata de
mitoza celulara si hipoxia celulara. Tesuturile necrotice sau
fibrozate au un nivel redus al acumularii FDG.
Valoarea standardizata a captdrii (standardized uptake
value - SUV): este utilizata pentru a determina daca o leziune
are o captare crescuta de 18FDG. SUV normalizeaza canti-
tatea acumulata de FDG intr-o regiune de interes (ROI) (in
mCi/ml) la doza totals administrata si la greutatea pacientului
(in mCi/kg). Un nivel persistent sau crescut al acumularii
FDG intr-o leziune (SUV > 2.5) pe imaginile tardive este un
indicator al malignitatii.

Bibliografie
1. BailevDL, TownsendDW. ValkPE, Maisey MN - Positron Emis-
sion Tomography. Basic Science - Springer. London, 2005

S-ar putea să vă placă și