ELEKTRONIK

Frequency controller for vibratory feeders


REOVIB MFS 168
Cabinet mounted version (IP 20)

• Mains voltage compensation


• Suitable for 110 V and 240 V supplies
• Internal setpoint using display, external with potentiometer
• Enable input 24 VDC or contact
• Adjustable frequency range of 30...140 Hz
• Sinusoidal output current
• Automatic optimum frequency search
• Operation via LED display and keypad
• Start/Stop keys for the feeder in the touch panel
• Memory storage for user settings
• All settings can be made without opening the unit
• Also available with integrated track control and amplitude regulation
Frequency controller for vibratory feeders
REOVIB MFS 168

The REOVIB MFS 168 series of variable- Type Range REOVIB MFS 168
frequency regulators is specially Supply voltage: 110 V, 240 V, ±10 %, 50/60 Hz
designed for controlling vibratory Output frequency: 30...140 Hz; depending on type,
feeders. The units produce a highly other frequency ranges are possible
stable output frequency that is adjustable Output voltage: 0...95 V, 0...205 V
in 0.1 Hz increments. Manual “tuning” Output current: 3A 6A 8A
time of the mechanical feed system is Setpoint: Internal using display
significantly reduced. Thanks to the External with 0...+10 VDC,
sinusoidal output, the feeder runs quietly 0(4)…20 mA or
and ensures gentle product handling. potentiometer 10 kΩ
Settings are adjusted by using a touch
Enable signal: 24 VDC or contact
panel and an integrated digital display.
Status relay: Changeover contact 250 V, 1 A
The feed rate setpoint can be adjusted
externally in several ways, including the Track control: (optional) Internal power supply 24 VDC for
use of 0…10 V or 0(4)…20 mA signals. PNP sensor
One set of user parameters can be Amplitude regulation: sensor connection:
stored and recalled. Depending on the (optional) e.g. with type REOVIB SW 10
version, the unit is also available with Operating temperature: 0...+45 °C
integrated track control (backlog) and Protection class: IP 20
amplitude feedback regulation to ensure
load-independent feeder operation.
Electrical connections are made via
terminals in the front panel, and the unit
is designed for panel mounting in a
5
cabinet.
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9

+24V

+24V

+5V F I
31 32 33 34
31 32 33 34

+24V
P 0
D

SPEED
P P P
C
21
21 22
22
23
23
24
24

A1
25
25

A2
26
26

L
27
27

N
28
28

PE
29
29

PE

A B 12

Dimensions A B C D
[mm] [mm] [mm] [mm]
REOVIB MFS 168 3A 94 132 193 205
REOVIB MFS 168 6A 94 175 193 205
REOVIB MFS 168 8A 104 195 193 205

REO ELEKTRONIK AG
Brühler Strasse 100
D-42657 Solingen
Phone +49-(0) 212-88 04-0
Fax +49-(0) 212-88 04-188
www.reo.de
email: main@reo.de Subject to technical modifications without prior notice.

S-ar putea să vă placă și