Sunteți pe pagina 1din 2

EM1

Single Phase Multifunction Electricity Meter


Multi-Energy,MDI, Multi-Rate Tariff
SYED BHAIS (PVT) LTD.

EM1 Electricity meter is a high quality, high reliability, low cost Solid State kWh
meter platform that is easily adaptable to various Automated Meter Reading
(AMR) technologies.
The state of art engineering design made it possible to have a variety of features &
functionalities all on a singe board. The heart of meter is a high speed, high
resolution Digital Signal Processing engine integrated with a micro-controller
core and RTC to cover all metering requirements in compact space with high
degree of accuracy & reliability.

STANDARDS COMPLIANCE METERING FEATURES

• IEC 62052-11 • Accuracy Class 1.0 & 0.5 (Optional)


• Metering on Phase wire
• IEC 62053-21
• Optional simultaneous metering on both Phase & Neutral
• IEC 62053-23
wires with automatic selection of higher value for registration.
• IEC 62053-22 • Reactive Energy Measurement (kVArh)
• IEC 62053-61 • Apparent Energy Measurement (kVAh)
• Optional Single Wire Metering (also called Missing Neutral
PROGRAMMABLE Billing) with no voltage applied to meter terminals & anyone of
DEMAND
phase or Neutral current passing through meter (Current > 1A)
MEASUREMENTS
MULTIFUNCTION CAPABILITIES
• Selectable among Block or
Rolling demand measurement ⇓ Demand Metering
methods • Time of use (TOU) Metering
• Programmable demand
• Event Log
interval
• Optical Communication for Reading/ Programming
• Meter Errors, Cautions & Diagnostics display.
PROGRAMMABLE TOU
MEASUREMENTS • IEC 62056-21 compliant optical communication
• Windows GUI based software for downloading/ uploading
• Upto 4 programmable seasons Reading & Programming information.
• Upto 4 programmable Dates
Types
• Upto 4 programmable Rates
• Upto 100 programmable dates
for specific rate schedule The Infinity Bandwidth Company

9001
STANDARDS COMPLIANCE ·RANGE OF OPERATION

• IP54 compliant meter enclosure Cur rent r ange: 10A basic to 60 Amps Maximum
• Protective class II insulation Voltage r ange: 130V to 456V AC
Temper ature Range:: -40°C to +85°C
• Compliant to IEC standards of Humidity : 0 to 90% relative humidity non-condensing
Electro-magnetic compatibility UV exposure:: Casing and LCD designed for outdoor installation
even in direct sunlight
including
• IEC 61000-4-2
• IEC 61000-4-3 REAL TIME MEASUREMENTS
• IEC 61000-4-4
• IEC 61000-4-5 • Instantaneous Power (P) • Instantaneous Voltage (V)
• IEC 61000-4-6 • Instantaneous Current (I) • Instantaneous Power Factor (pf)
• CISPR 22
• Instantaneous Phase Angle (Φ) • Instantaneous Frequency
• Instantaneous Temperature
CONFIGURABLE DISPLAY DISPLAY
OPTIONS
• Large six digits for displaying quantities
Three Modes of Display (kWh, kVArh, V, I etc)
1) Normal Mode • Two small digits for Display Sequence number
2) Alternate Mode • Voltage indicator
3) Test Mode
• TOU Battery indicator (Blinking while LOW & ON when OFF)
• Alternate (ALT) and Test (TEST) mode indicators
• Programmable Test mode interval
• TOU rate indicators
• Programmable display scroll
• UV protected LCD design for longer life and reliability in outdoor meter
sequence
installation
• Programmable display item time • Display operation on Battery to facilitate reading during Power Outages.
(3 to 10 seconds)
• Disk Analog & Quadrant Indicators
SECURITY FEATURES OF SECURITY FEATURES
SOFTWARE
• Sealable Front Cover to block unauthorized access to meter pa
Three Levels of Security • S e a l a b le er mTi n a l B l o c k C o v e r
• Administrator • R a i n p r o o f b u t t eo snt s mf o rd eT a n d D i s p l a y s w i t c h
• Writer
• Reader ANTI-TEMPER FEATURES

EVENT LOGS FOR POSSIBLE • Simultaneous Meter ing on both Phase & Neutr al
TEMPER CONDITIONS 1 M e t erre c o r de ns egri e sd u et o c u r r e fnlto w i ni nge a c ho f P h a s & e N e u t rw a li r e s
a n d s t o r etsh e ms e p a r a t et ol yf a c i l i t ua t ei l i tsyt af f t o i n v e s t i gtaetm e pering
activities
• Phase Reversal/Negative energy 1 To t aAl c t i vEen egrya c c u m u l a t ipoenr fios r mu es di nhgi g h eo rft w oe n egri e bs a s e d
flow u p o anp r o g r a m m da ibffle er e n tcher e s h o l d
• Demand Reset • U n i - de icrt i o n a l M e t e r i n g
1 A n e g a t i v e f l o wg yo fw ei nl le ra l s o r e s u l t i n p o s i t i v e a c c u m u l a t i o n
• Test mode activation 1 Phase reversal is detected and Logged as event
• Programming mode activation • Sin gW l ei re M e t e r i n g
• Single wire metering start & 1 I f o n l yP h a s oe r N e u t r ac lu r r e ni st f l o w i nt gh r o u gmh e t e w r i t ho t h e w r ire
finish. d i s c o n n e cf rt oe dmm a i nas s w e l al s l o a ds i d em, e t ecr a ns t i lpl e r f o rmme t e r i n g
b a s e ud p o nN o m i n V a ol l t a gaen du n i t py o w efra c t.oTr h i sr e g i s t r a ct iaonnb e
• Meter Reading/Programming s t o r e sde p a r a t eo lr yi t c a n b e a d d e dt o To t a lE n egry R e g i s t be ar s e du p o n
activation. c u s t o ms ee rl e c t i So inn. g W l ei r eM e t e r i Rn ag n g e1 :. 0 A m p s ~ 6 0 A wm i t ph<s0 . 5 %
• Power Down/up a c c u r a. Ac yn e v e ni ts a l s ol o g g eodn S i n g lWei r eM e t e r i nMge. t earl s oD i s p l a y s
t h i cs o n d i t ai oscna u t i oo nnL C D .
PROGRAMMABLE
THRESHOLDS FOR EVENTS For more details please contact
SYED BHAIS (PVT) LIMITED
• Under voltage/overvoltage 200-FEROZEPUR ROAD, P.O.BOX 483
LAHORE-54600, PAKISTAN
• Over Current PHONES: (+92-42) 111-758-758, 7577901 & 7560198
• Demand overflow SYED BHAIS (PVT) LTD. Fax: (+92-42) 7588199 & 7596203
• Over temperature website: www.syedbhais.com
info@syedbhais.com