Sunteți pe pagina 1din 6

EMC Navisphere Analyzer

Installation Guide
P/N 069001182
REV A04

May 14, 2004

This document contains important installation information. Read this


document completely before installing the Navisphere® Analyzer
software on a CX-Series storage system.

For information on installing Analyzer on an FC4700 storage system, refer to the


Version 6.6.0 entry for the Navisphere Analyzer 6.X Installation Guide on the EMC
Powerlink website. For information on how to access this site, see Finding
Current Information on page 5.

Major topics are


◆ Analyzer Software.................................................................................2
◆ Navisphere Analyzer CDs ...................................................................3
◆ Installation ..............................................................................................4
◆ Documentation CD ...............................................................................5
◆ Finding Current Information...............................................................5

1
Analyzer Software

Analyzer Software
Analyzer software consists of a storage-system provider and a user
interface (UI) for managing the Analyzer functionality, including the
archives, and a command line interface (CLI) for managing the
archives.

Analyzer Provider To use Analyzer with a CX-Series storage system, the Analyzer
provider must be enabled on the storage system. The provider is
enabled when the Analyzer Enabler, which is part of the Analyzer kit,
is installed on the storage system. If you ordered Analyzer with a
new CX-Series storage system, you or your service provider installs
the Analyzer Enabler during storage-system initialization.

Once the provider is enabled, it stays enabled even if you upgrade the
FLARE™ Operating Environment software on the storage system.

Analyzer UI The Analyzer UI requires the Management UI, which is part of


Navisphere Manager. For you to use these UIs, they must be enabled
on the storage system at which you will point your browser. Prior to
shipment, both UIs are enabled on CX300, CX500, and CX700 storage
systems, but not enabled, on CX200, CX400, and CX600 storage
systems. Both UIs are enabled on a CX400 or CX600 storage system
when the Manager Enabler, which is part of the Manager kit, is
installed on the storage system. If you ordered Manager with a new
CX200, CX400, or CX600 storage system, the Manager Enabler can be
installed during storage-system initialization.

Once the UIs are enabled, they stay enabled even if you upgrade the FLARE
Operating Environment software on the storage system.

Analyzer CLI Analyzer CLI is part of the Navisphere CLI, which ships with the
Navisphere Host Agent kits.

2 EMC Navisphere Analyzer Installation Guide


Navisphere Analyzer CDs

Navisphere Analyzer CDs


The table below lists the software required for installing Analyzer.
The Analyzer CDs ship with the Analyzer kit and the Manager CD
with the Manager Enabler ships with the Manager kit.

CD Title and Part Numbera Files on CDb Installed On

EMC Analyzer Enabler v01.xx.5.yyy .ena File Storage system


PN 053-001-226 • AnalyzerEnabler_01.xx.5.yyy.ena

EMC Navisphere Analyzer Accessories v02.xx .exe File for Optional Windows Host Microsoft Windows Server™
P/N 053-001-227 • Windows_AnalyzerProvider_6.w.x.y.z.exe 2003, Windows® 2000,
Windows XP, or Windows
Note: This executable is optional and should be NT® server
installed only if you have storage systems
without the Storage Management Server
software installed; you want to manage these
systems using Navisphere Manager; and you
want to analyze the performance of these
storage systems with Analyzer.
This file also requires that the following files from
the Navisphere Manager Accessories v02.xx CD
(P/N 053-001-223) be installed on the host:
• Windows_ManagementServer_6.w.x.y.z.exe
• Windows_UIs_6.w.x.y.z.exe
Files installed as part of the Windows server
installation are protected by ACLs (under NTFS).
ACLs are not supported on FAT file systems, so
the files that normally would be protected under
NTFS are not protected.

Navisphere Manager Enabler v01.xx.5.yyy .ena File Storage system


P/N 053-001-224 • NavisphereManagerEnabler_01.xx.5.yyy.ena
a. In the CD title, x and y are numbers that vary depending on your version.
b. In the filenames, w, x, y, and z are numbers that vary depending on your version.

EMC Navisphere Analyzer Installation Guide 3


Installation

Installation
IMPORTANT - When you install new software on a storage system,
do not remove or reboot an SP while installation is in progress. Doing
so may leave the storage system in a transient state where it cannot be
restarted. Wait for the entire upgrade process to complete and
automatically reboot the SPs.

Installation Prerequisites
EMC Navisphere® Manager must be enabled on the SPs in at least
one storage system in the Navisphere domain containing the storage
systems that will participate in the same mirror. (For information on
Navisphere domains, see the EMC Navisphere Security Administrator’s
Guide on the documentation CD.)

Prior to shipment, Manager is enabled on CX300, CX500, and CX700 storage


systems, but not enabled on CX200, CX400, and CX600 storage systems.
Manager is enabled on these systems when the Manager Enabler is
installed.The Manager Enabler can be installed on CX200, CX400, and CX600
storage systems at the same time as the Analyzer Enabler. Once Manager is
enabled, it stays enabled even if you upgrade the FLARE™ Operating
Environment on the storage system.

To Install .ena Files on a Storage System


To install one or more .ena files on a storage system, follow the
procedure in the software installation section of the EMC Navisphere
Manager Administrator’s Guide (P/N 069001125). See the table on
page 3 for a list of .ena files.

4 EMC Navisphere Analyzer Installation Guide


Documentation CD

To Install Optional .exe Files on a Windows Server (Portal)


If you want to use a Windows PC or server as a portal in your
Navisphere domain, you must install the Windows Management
Server and Windows UI executables on the portal. These executables
are provided on the Navisphere Manager Accessories CD (see the table
on page 3). If you want to use Analyzer to monitor the performance
of storage systems managed by the portal, you must also install the
Analyzer provider executable on the portal. This executable is on the
EMC Navisphere Analyzer Accessories CD.
To install these executables, follow the instructions in the
InstallShield Wizard and select the Manager UI, the Analyzer UI, and
the UIs for any other software installed on storage systems in the
same domain as the Windows server. Once you have installed these
executables, refer to the EMC Navisphere Manager Installation Sheet
(P/N 069001172) for instructions on initializing security and setting
the Management Server settings for the server.

Documentation CD
In addition to this document, the following document is available on
the EMC CX-Series Hardware and Software Documentation CD
(P/N 053-001-228), which ships with the storage system:
EMC Navisphere Analyzer Administrator’s Guide (P/N 069001158)

Finding Current Information


The most up-to-date information about Analyzer, including release
notes, is posted on the EMC Powerlink website. We recommend that
you download the latest information before you use Analyzer. If you
purchased this product from an EMC reseller and you cannot access
Powerlink, the latest product information should be available from
your reseller.
To access EMC Powerlink, use the following link:
http://powerlink.emc.com
After you log in, select Support > Document Library.
You can view these documents with a PDF viewer, such as the latest
version of Adobe Acrobat Reader. You can download a free copy of
this reader from http://www.adobe.com/products/acrobat/.

EMC Navisphere Analyzer Installation Guide 5


Finding Current Information

Copyright © 2002 - 2004 EMC Corporation. All Rights Reserved.


EMC believes the information in this publication is accurate as of its publication date. The information is subject to
change without notice.
THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." EMC CORPORATION MAKES NO
REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS
PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
Use, copying, and distribution of any EMC software described in this publication requires an applicable software
license.
Trademark Information
EMC2, EMC, CLARiiON, Navisphere, and PowerPath are registered trademarks and Access Logix, FLARE, MirrorView, SAN Copy, and SnapView are
trademarks of EMC Corporation.
All other trademarks mentioned herein are the property of their respective owners.

6 EMC Navisphere Analyzer Installation Guide