The ABIOCOR

-Total Artificial Heart System

PRESENTED BY:-
G.V.NAGENDRA KUMAR B.SIVA KUMAR
III B.Tech, ECE III B.Tech, ECE
E-mail:g.v.n.kumar143@gmail.com Email:kumar.siva953@gmail.com

ELECTRONICS AND COMMUNICATIONS ENGINEERING

SREE VIDYANIKETHAN ENGINEERING COLLEGE,TIRUPATI.


Abstract:
There are many people suffering with heart problems and heart
failure problems. The one and only remedy for them is heart
transplantation and VAD systems. Our paper presents an artificial
heart system which is called ABIOCOR which overcomes the defects
in the above two mentioned methods. The abiocor system consists of a
set of internal and external components. The internal components
consist of a thoracic unit and internal TET along with implanted
controller and battery. The external components consist of external
TET, console PCE, PCE battery bag etc., each part has its own use
and made the ABIOCOR work properly. In this paper we presented
it’s design and the components present in it and the importance of
each component
.-----------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------
------------------------------------------------------

1. Introduction: amount of donor hearts in


The AbioCor relation to the
Total Artificial Heart System is amount of
designed to give patients with patients in
heart failure an option other than need of a
heart transplant and Ventricular donor heart is
Assist Device (VAD). VAD minuscule.
Systems are intended for patients Heart patients
with a failing left ventricle; the looking to
VAD is implanted and replaces have a VAD
the ventricle by acting as a pump. implant may
Heart Patients hoping to extend find that the
their life expectancy by having a system is not yet so safe or
heart transplant may not be able dependable because the materials
to realize their hope because the

2
used for it have, in the past, run the similarity in inflows and
the risk of causing a stroke. Due outflows, the thoracic unit is very
to the lack of reliable options different from a natural heart
heart patients have, researchers because it is made of plastic and
have been trying to come up with titanium and it is not full of veins
a new method to aid these as a natural heart is. The external
patients. The most recent success and internal TETs are almost
has been the AbioCor Total identical in their design, they
Artificial Heart System. The both have a round top and a long
AbioCor System acts as a natural thin end (similar to the shape of a
heart and allows the patient to be lollipop); however, the external
free of too many restrictions; the TET is covered with silicone.
patient is allowed to be mobile, The rest of the AbioCor System’s
and is also allowed to return components have geometric
many of the activities he designs (mostly rectangular) and
participated in before undergoing are not extravagant in their
heart failure. The AbioCor is also appearance. For example, the
designed to increase the life implanted controller and the
expectancy of the heart patient by implanted battery appear very
at least two times (Factmonster). similar; they are both cased in
2. Design: titanium, they both are covered in
The components the solid color of titanium, and
of the AbioCor system are simple they both have the same shape.
in design; that is, the components The console and the PCE control
are not decorated, nor are they
coated with materials that are not
necessary. The thoracic unit has
a similar physical appearance to
the appearance of a natural heart.
This is because it contains
inflows and outflows; aside from

3
module are generally boxes with artery, another to the left atrium
no artistic designs or variety in and another to the right atrium.
color. The
3. Internal Components: thoracic unit contains two
3.1. Thoracic Unit hydraulic motors; one keeps the
(Artificial Heart):
blood pumping from each
The thoracic
ventricle (blood pump), and the
unit weighs slightly more than
other operates the motion of the
two pounds (0.9 kg) and is about
four heart valves. The pumping
the same size and shape of a
from these hydraulic motors is
natural heart. It is made of
caused by an oscillating pusher
titanium, and Angioflex, a
plate that squeezes sacs that then
polyurethane plastic. The
emit blood to the lungs and to the
thoracic unit is implanted in the
rest of the body (Total Artificial
chest, where a natural heart
Hearts (TAH)). Additionally, the
would be located, and connects to
unit has a left and a right blood
the right and left atria, the aorta,
pump. Each blood pump has an
and the pulmonary artery. In
inflow opening and an outflow
order for blood to enter and exit
opening. When the blood moves
from the unit, grafts must be
to the right blood pump the blood
sewed onto the right and left
is pumped
atria, the aorta, and pulmonary
out through the outflow opening
artery of the patient. They must
and is led to the lungs. When the
also be sewed onto the thoracic
blood moves into the left blood
unit’s four heart valves. These
opening it will be led to the rest
grafts then allow for the two
of the body.
arteries and the two atria to each
be snapped onto the graft of one 3.2. Implanted
Transcutaneous Energy
of the heart valves. Conclusively,
Transmission (TET):
one valve will be snapped onto
the aorta, another valve will be
snapped onto the pulmonary

4
The the
implanted TET is an electric coil
abdomen of the patient’s body. It
that provides all of the AbioCor
is secured in a titanium case and
System’s internal devices with
connects to all internal
electrical energy. It is connected
components (the implanted TET,
to the thoracic unit, the implanted
the artificial heart, and the
controller, and the implanted
implanted battery), meaning that
battery. The implanted TET is
it also receives energy from the
located on the upper-left area of
implanted TET. The job of the
the chest (opposite of the
implanted controller is to oversee
artificial heart). In order to fit the
the internal components of the
patient’s insides properly, it has
AbioCor System, to
the capability of adjusting its
communicate with the AbioCor
shape. Because the implanted
Console or the Patient-Carried
TET provides the AbioCor
Electronics (PCE), and to control
System with energy without
the blood flow output of the
having to run wires in and out of
artificial heart. In order to
the patient’s body, it may also be
monitor all internal components
referred to as a wireless power
and communicate with external
transfer system. In order to
components, the implanted
provide internal devices with
controller exchanges information
energy without the use of an
with the console or the PCE
external power connection, the
(whether the implanted controller
implanted TET converts energy
exchanges information with the
from radio waves, sent to it by an
console or the PCE depends on
external TET, to electrical
which of these two power sources
energy.
the patient is using), if a problem
3.3. Implanted Controller:
The is detected by either of the two
implanted controller is a small external power sources, the
automatic computer located in patient is immediately notified.

5
The implanted controller is also components are be the artificial
able to manage the artificial heart and the implanted
heart’s cardiac output rate to controller). The battery is
make sure that the artificial heat constantly being recharged by an
generates the necessary blood external battery pack that
flow. The cardiac output rate is transfers power to the internal
the “amount of blood that flows components of the Abercorn
through the heart, expressed in System through the external and
liters per minute. Due to internal TETs. If the patient were
monitoring of blood outflow, the to separate himself from the
incoming blood flow is external TET and battery pack
guaranteed to match the outgoing (such as to take a shower), the
blood flow. Aside from working implanted battery would provide
automatically, the implanted the internal system of the
controller can also be supervised AbioCor with energy for 30 - 40
by a clinician. minutes (Leung, Benedict). The
3.4. Implanted Battery: battery itself can last for about a
The year before it would need to bed
implanted battery is placed in the replaced. In order to replace it,
abdomen, opposite from the the patient would be required to
implanted controller, and is receive minor surgery.
implanted when the implanted
4. External
controller and the artificial heart Components:
are placed in the patient’s body. 4.1.External
Transcutaneous Energy
Just like the implanted controller,
Transmission (TET):
the implanted battery is kept in a The
titanium case, it receives energy external TET is placed directly
from the external TET, and is over the location of the internal
connected to all other internal TET to transfer energy through
components (in the case of the the skin (the external TET is
implanted battery, these internal placed over the skin, while the

6
internal TET is placed under the radio waves (Shiba, Kenji). The
skin, inside the patient’s body). It amount of this energy is enough
is connected to the console or the to penetrate the skin and to be
Patient-Carried Electronics received by the internal TET.
(PCE) and is in the form of a 4.2.Console:
silicone ring. The external TET The console

provides the internal TET with is a small computer containing a

energy from either the PCE keyboard and screen that is used

control module or the AbioCor to provide power to the external

console. Both of these act as TET and the internal TET and is

power supplies so what also used to communicate with

determines which will be used is the implanted controller. To

the location of the patient. If the provide power to both TETs, the
console is plugged into an
electrical outlet. The internal
TET is then able to transmit
energy by being plugged into
the back of the console. In order
to communicate with the
implanted controller, the
console uses wireless
patient is stationary and is near a
technology; it consists of an
power outlet, his source for
antenna that sends commands to
energy may be the console; if the
the implanted controller and then
patient is mobile and has no
receives information regarding
intentions of remaining in the
the internal components’ status.
same location for a long period of
If something goes wrong within
time, he may use the PCE as a
the internal system, the console
power source. The several Watts
immediately notifies the patient
of energy received from the
by setting off an alarm sound or
external TET are transmitted to
alarm lights (Abiomed). In case
the internal TET in the form of

7
of a power outage, the console mobile) and two pairs of
also consists of a backup battery batteries.
that will keep the system 4.4.PCE Battery Bag:
powered for 35 – 40 minutes The PCE

(Abiomed). Battery Bag weighs about 10


pounds and may be carried by
4.3. Patient-Carried
Electronics: using an attached shoulder strap
The patient using (Abiomed). The inside of the bag
the AbioCor System is not forced contains a battery
to stay in bed hooked up to compartment that holds four
the system’s console; he is batteries, and plastic
also given the option to move cardholders. The outside of
around and not have to the bag contains pockets
depend on a power outlet to used to carry the PCE
power the system’s control module and any
components. If the patient extra objects the patient may
chooses to be mobile he may want to place in them.
use the Patient-Carried
4.5.PCE Batteries:
Electronics (PCE) by plugging Each pair
the external TET into the PCE’s of PCE Batteries supplies the
control module. The PCE serves AbioCor’s internal system with
as a portable power supply, and is power for about one hour
placed in a shoulder bag called (Abiomed). Since the battery bag
the PCE Battery Bag. The battery can carry two pairs of PCE
bag stores a control module (this batteries, the internal system may
module takes the place of the be supplied with power for about
console when the patient is two hours if the patient uses only
the two pairs stored in
the battery bag. The
batteries used for the
PCE package differ
from common store-

8
bought batteries, the PCE form of radio waves. By
batteries are especially made to converting the energy from the
power the AbioCor system. power source, the external TET is
Additionally, since the PCE able to transfer energy to the
batteries don’t last very long, internal TET. The control
they must be changed several module, like the console, also
times a day and the patient must monitors the status of all of the
be aware of the amount of
batteries he will be needing so he
can take extra batteries (aside
from those located in the battery
bag) if necessary. AbioCor System’s internal
4.6.PCE Control Module: components by communicating
The PCE with the implanted controller
control module is to be placed in through wireless technology. If a
one of the pockets, located on the problem occurs within one of the
outer part of the PCE battery bag, internal devices, the control
where it is connected to the module immediately notifies the
batteries by a battery cable and is patient.
also connected to the external
5. Function:
TET. Instead of being connected To maintain
to the batteries, the control operation, the AbioCor System
module may also be connected to must first have a source of
any source of Alternating Current power; depending on whether or
(AC) Power by using an AC not the patient is mobile, this
Power Adapter. Once connected power source will either be the
to a power source (batteries or console or the PCE control
AC Power), the control module module. Both power sources
converts the energy from the cause the AbioCor System to
power source into perform the same function and to
electromagnetic energy in the do so in a similar way. The only

9
difference between the two simultaneously as a natural heart
sources is that the console would.
receives its energy from a power Besides
outlet and is stationed in one controlling the artificial heart’s
place and the PCE control cardiac output rate, the implanted
module receives its energy from a controller also oversees the
battery pack carried in the PCE performance of all internal
battery bag and is portable. From components to make sure that
the power source, energy will everything is working properly.
travel through the external TET The information gathered by the
in the form of radio waves. These controller’s supervising is sent to
radio waves will penetrate the the AbioCor System’s power
patient’s skin and enter the source (the console or the PCE
implanted TET, which will then control module) using wireless
convert the radio waves into technology. If the power source
electrical energy. This electrical detects a problem, the patient is
energy will travel to the notified by an alarm light or an
implanted battery where it will alarm sound. Otherwise, if no
remain to keep the battery problems are detected the
charged. The energy stored in AbioCor System follows a cyclic
the battery will be used by the function and continues to operate.
implanted controller to monitor 6. Conclusion:
the thoracic unit’s (artificial The

heart) cardiac output rate. This AbioCor System consists of a set

energy supplied to the artificial of internal components and

heart keeps the blood flowing external components. The

into the heart and out into the internal components are those

body. The heart will take turns in located inside the patient’s body;

sending blood to the lungs and to they are the thoracic unit

the rest of the body because it (artificial heart), the internal

cannot send blood to both areas Transcutaneous Energy

10
Transmission (TET), the to convert this energy into usable
implanted controller, and the energy for all internal
implanted battery. The external components and to transport that
components are those located energy from the patient’s exterior
outside of the patient’s body; to the patient’s interior. Once the
these are the external energy has reached the patient’s
Transcutaneous Energy interior, it is used to maintain the
Transmission (TET), the console, implanted battery charged and to
the Patient-Carried Electronics provide power for the artificial
(PCE), the PCE battery bag, the heart and for the implanted
PCE batteries, and the PCE controller. All of these
control module. The PCE control components keep the artificial
module and the console both heart pumping blood and keep
serve to provide the whole sending that blood throughout the
system with energy. The internal patient’s body.
and external TETs work together

7.References:

Abiomed. Product Details.


<http://www.abiomed.com/products/heart_replacement/product_de
tails.cfm>

Bonsor, Kevin. How Artificial Hearts Work.


<http://science.howstuffworks.com/artificial-heart.htm>

Brain, Marshall. How Hydraulic Machines Work.


<http://science.howstuffworks.com/hydraulic.htm>

Cho, B.H., Gyu Bum Joun. “An energy transmission system for an
artificial heart using leakage inductance compensation of
transcutaneous transformer”. IEEE. Nov. 1998
< http://ieeexplore.ieee.org/xpl/abs_free.jsp?arNumber=728328>

Factmonster. heart, artificial.


<http://www.factmonster.com/ce6/sci/A0823119.html>